• 제목/요약/키워드: heating temperature and time

검색결과 1,375건 처리시간 0.026초

Effects of Heating Temperature and Time on the Mechanical Properties of Heat-Treated Woods

  • Won, Kyung-Rok;Hong, Nam-Euy;Park, Han-Min;Moon, Sun-Ok;Byeon, Hee-Seop
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권2호
    • /
    • pp.168-176
    • /
    • 2015
  • This study was performed to investigate the effects of heat treatment the on mechanical properties of two species of wood under different heating conditions including at $180^{\circ}C$ for 12 h and 24 h, and at $210^{\circ}C$ for 3 h and 6 h. Two species of wood, Pinus densiflora and Larix kaempferi, were exposed to different heat treatments to assess the effects on the volume change, bending properties in static and dynamic mode and compressive strength. The results showed heat treatment caused significant changes in mechanical properties such as the static and dynamic moduli of elasticity ($MOE_d$ and $MOE_s$), and the modulus of rupture (MOR). The volume of the wood after heat treatment decreased as the heating temperature and time were increased. The bending strength performance of the wood after heat treatment decreased as the heating temperature and time were increased. The effect of heat treatment at a high temperature on the bending MOR was greater in both species than that for a long time. However, the compressive strengths of all the heat-treated samples were higher than the control sample. Furthermore, highly significant correlations between $MOE_d$ and MOR, and $MOE_s$ and MOR were found for all heating conditions.

지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구 (Comparative Study on Performance of Wet-type and Dry-type Floor Heating Systems Using Geothermal Heat Pump)

  • 이병두;이세진;이대우;오성해;남우동
    • 신재생에너지
    • /
    • 제5권4호
    • /
    • pp.60-65
    • /
    • 2009
  • The present study was conducted for a comparative evaluation of wet and dry floor heating systems using geothermal heat pump. We circulated hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.9^{\circ}C$ for wet type and $32.7^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. As a result, in case of floor heating system using low temperature circulation water, dry type was more practicable for stable floor heating than wet type in terms of floor temperature and access time to indoor set temperature.

  • PDF

고온을 받은 고강도 콘크리트의 역학적 특성에 관한 실험적 연구 (An Experimental Study on the Mechanical Behavior of High-Strength Concretes Subjected to High Temperature)

  • 양근혁;홍성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.25-28
    • /
    • 2005
  • The experimental results on the mechanical behavior of high-strength concretes subjected to high temperature were presented. Main variables were heating temperature, heating continuance time, and cooling condition. The compressive strength properties of high strength concrete(HSC) varied differently with temperature than those of normal strength concrete(NSC). HSC had higher rates of strength loss than NSC in the temperature range of between $20^{circ}C$ and $400^{circ}C$. Especially, HSC exploded in $400^{circ}C$ of high temperature.

  • PDF

광발열소재와 버블시트를 조합한 양생시트가 모르타르의 표면온도 이력에 미치는 영향 (Effect of Curing Sheet Conbined with Bubble Sheet and Heat generating Materias under Light Source on Surface Temperature of Cement Mortar)

  • 김수호;후윈야오;백성진;한준희;김종;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.160-161
    • /
    • 2022
  • This study is to investigate the temperature history over time of the cement mortar to confirm the bubble sheet insulation effect using the heat generat sheet. As a result of the experiment, it was confirmed that the heating effect was 6℃ higher on average than other types of sheets when the heating sheet is attached on the bottom of the double layered bubble sheet. For future research, it is planned to verify the heating performance by using the heating sheet under the same environmental conditions as the heating performance will be verified.

  • PDF

전열을 이용한 금형가열코어의 제작 및 이를 이용한 성형품의 제조와 평가 (Fabrication of electrical heating mold core and evaluation of injection-molded parts by various mold heating methods)

  • 김동학;류지원;손영곤
    • 한국산학기술학회논문지
    • /
    • 제7권4호
    • /
    • pp.738-742
    • /
    • 2006
  • 본 연구에서는 전열을 이용한 금형가열 장치를 설계 및 제작하였다. 서로 다른 가열원을 가진 세 가지 방법으로 제작을 하여 시간에 따른 온도 프로파일을 조사함으로써 그 성능을 평가하였고, 이를 이용하여 사출성형품을 제조하여 수축률, 밀도, 표면 거칠기, Weld line등을 측정하여 실용적인 적용 가능성을 조사 하였다. 가열시간($130^{\circ}C$ 도달시간 14초) 및 사이틀 타임(55초)은 실용화가 가능한 수준으로 나타났다. 일반 사출성형방식으로 성형한 제품과 비교했을 때 수축률은 전열을 이용한 가열방식으로 사출한 성형품이 5.1% 감소하였고, 밀도는 2.66% 증가하였다. 표면 거칠기는 3배 이상 향상 되었고, 일반 사출에서 나타나던 Weld line은 전열가열방식에서는 나타나지 않았다.

  • PDF

마이크로웨이브와 고온발열체를 이용한 연속식 공정의 유류오염토양 처리에 관한 연구 (A Study on Treatment of a Contaminated Soil by Oil using Continuous System of High Temperature Heating Element and Microwave)

  • 하상안;유미영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제17권1호
    • /
    • pp.8-12
    • /
    • 2012
  • This study is maintains the condition of high temperature (above $600^{\circ}C$) within a short time using on microwave and high temperature heating elements. And removal characteristics according to changes in soil moisture, microwave power and temperature through the decomposition of the contaminated soil by oil. The difficulty resolvability material was sort of lubricating oil having long carbocyclic (C18-C50) and TPH removal rate reached 85.2% at 6 kW and $700^{\circ}C$ and thus the contaminant was removed 1,788 mg/kg within a process time of 40 minutes. In the case of light oil, gasoline contaminated soil, the removal amount showed 567 mg/kg and the treatment rate reached 98.4% at 6 kW, $500^{\circ}C$ and 20 minute. In the case of non-resolvability reached TPH concentrations on 2,000 mg/kg of worrisome level of soil contamination in the 3 zones at 6 kW, $700^{\circ}C$ and 30 minute. At the time, showed up processing costs 8,173 won per ton.

감 추출물로 염색한 레이온직물의 열처리에 의한 발색효과 (Effect of Heating Process on Color Values of Rayon Fabrics Dyed with Persimmon Extract)

  • 김옥수;장정대
    • 한국의류산업학회지
    • /
    • 제11권6호
    • /
    • pp.961-967
    • /
    • 2009
  • In order to examine the availability of heat treatment for color developing in persimmon dyeing, the rayon fabrics dyed with persimmon extract from unripe persimmon which was used after stock and fermentation. Dyed fabrics were heated at various temperature and time by contacting press heat and drying heat. Color developing results were influenced by the difference of heating method. Press heating method is more available than drying heat method. Effect of temperature and time on ${\Delta}Ea^*b^*$ and color values of dyed rayon fabrics was considerable. Considering the practical aspect, The temperature around $140{\sim}160^{\circ}C$ and the time no longer 40 minutes can be reach the region of the full color developing by press heating process. It was very shortened than any other method(drying air heat, xenon radiation, sunlight). The dyed rayon fabrics with heat treatment have darker and deeper red-yellow color than which by sunlight and xenon radiation.

Equivalent Point Method의 일반적 이용을 위한 연구 (Study on the Generalization of the Equivalent Point Method for Thermal Evaluation)

  • 임종환
    • 한국식품과학회지
    • /
    • 제22권5호
    • /
    • pp.575-581
    • /
    • 1990
  • 일정한 열처리 공정에 대해 Equivalent point가 존재함을 이상적인 두가지의 직접가열곡선 즉, $120^{\circ}C$에서 10분간 $135^{\circ}C$에서 10초간의 등온가열 곡선을 이용하여 예시하였다. 이러한 조건하에서 Arrhe nius model을 적용한 경우 임의의 Ea-값을 사용하여 G-값을 결정하고 Bigelow model을 적용한 경우, 임의의 z-값을 사용하여 F-값을 결정하였다. 이들 값을 사용하여 Equivalent time과 Equivalent Temperature를 두가지 방법 즉, 직교좌표법과 회기분석법에 의해 결정하였다. 이들 두 방법에 의해 결정된 Equivalent Point는 서로 일치하였으며 각각의 값은 초기에 가정했던 직접가열곡선의 가열시간 및 온도와 일치하였다.

  • PDF

Microwave 조사에 의한 Salmonella enteritidis, Salmonella typhimurium 과 E. coli의 불활성에 관한 연구 (Thermal Inactivation of Salmonella enteritidis, Salmonella typhimurium and E. coli O111 in Liquid Cultures During Microwave Radiation)

  • 이조윤;이강욱;배형철;김종우
    • 한국축산식품학회지
    • /
    • 제18권3호
    • /
    • pp.269-275
    • /
    • 1998
  • The purpose of this study was to determine the thermal inactivation of Salmonella enteritidis, Salmonella typhimurium and E. coli O111 in liquid cultures treated with microwave energy. Furthermore, this study was to introduce new methodologies for studying nonthermal microwave effects on microorganisms, using controlled microwave energy and specially designed apparatuses. For the automatic temperature control during microwave heating, the real time data acquisition and computation system is designed with BASIC routine. The automatic temperature control system used in the experiments perform relatively stable control at the experiment temperature of 45, 50, 55 60$^{\circ}C$ and 65$^{\circ}C$ for 30 minutes. The effects of microwave heating on liquid cultures was compared with that of conventional heating, still reduces effectively the number of pathogenic bacteria in liquid cultures. While no particular differences between microwave heating and conventional heating was observed in the activation of E. coli at 45$^{\circ}C$ test, the activation of Sal. enteritidis and Sal. typhimurium was slightly reduced during the microwave treatments.

  • PDF

비선형 슬라이딩 면을 이용한 온수난방 순환펌프 시스템의 온도 제어 (Temperature control for a hot water heating circulating pump system using a nonlinear sliding surface)

  • 안병천;장효환
    • 제어로봇시스템학회논문지
    • /
    • 제3권2호
    • /
    • pp.162-168
    • /
    • 1997
  • Digital variable structure controller(DVSC) is implemented to control the temperature for the hot water heating circulating pump control system. For the DVSC, a control algorithm is suggested, which using a nonlinear sliding surface and a PID sliding surface outside and inside of steady state error boundary layer, respectively. Smith predictor algorithm is used for the compensation of long dead time. The DVSC of the suggested algorithm yields improved control performance compared with the one of existing algorithm. The system responses with the suggested DVSC shows good responses without overshoot and steady state error inspite of heating load change. By decreasing sampling time, dead time and rise time are increasing, and system output noise by flow dynamics is amplified.

  • PDF