• 제목/요약/키워드: heating mortar

검색결과 81건 처리시간 0.023초

발포유리 혼합기포 콘크리트의 바닥충격음 차단성능 영향에 관한 연구 (The Effect of Aerated Concrete containing Foam Glass Aggregate on the Floor Impact Sound Insulation)

  • 윤창연;정정호;김명준
    • 한국소음진동공학회논문집
    • /
    • 제23권5호
    • /
    • pp.414-422
    • /
    • 2013
  • As structure-borne sound, the floor impact sound is one of the serious noises in residential building. Most of heating system applied to the typical Korean residential building is floor heating system which is called ondol. The ondol usually consists of finishing material, mortar with heating coil, light-weight aerated concrete and reinforced concrete. This study focused on the isolation of heavy-weight impact sound and modification of mortar and light-weight aerated concrete. Specifically the glass foam aggregate was added on light-weight aerated concrete. Also, water-cement ratio and amount of cement on mortar were revised. The sound pressure level of heavy-weight impact was measured in reverberation chamber using both bang-machine and impact ball. The size of specimen was 1 m by 1 m. Substitution ratio of glass foam aggregate on light-weight aerated concrete shows relationship with heavy-weight impact sound pressure level. In addition, heavy-weight impact sound pressure level was decreased with increment of water-cement ratio and amount of cement on mortar.

반복전기공급에 따른 발열모르타르의 발열 특성 (Heat generation characteristics of the heating mortar according to repeated electricity supply)

  • 김영민;임창민;권현우;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.170-171
    • /
    • 2022
  • In recent years, due to the occurrence of traffic accidents caused by black ice in winter, the number of personal injuries is increasing rapidly. Black ice is a phenomenon that occurs like a thin layer of ice on the road surface. Accordingly, many developments of heat-generating concrete are being developed to remove ice by increasing the temperature by supplying constant electricity to places where black ice is likely to occur. These heating elements are being developed by mixing a conductive material represented by carbon nanotubes with concrete. However, research up to now has been focused on efficient temperature rise and derivation of the optimum mixing ratio, and the evaluation of maintaining heat generation performance during continuous repetition is insufficient. Therefore, in this study, a heating test specimen was manufactured and 50V power was repeatedly supplied to evaluate the heating characteristics.

  • PDF

난방을 위한 바닥용 건조 시멘트 모르타르의 혼합수량비 변화에 따른 품질 특성 (Quality of Dry Cement Mortar for Floor Heating Depending on Water-to-Dry Mortar Rutio)

  • 박상준;황인성;이건철;김종
    • 한국건축시공학회지
    • /
    • 제21권3호
    • /
    • pp.181-188
    • /
    • 2021
  • 본 연구는 바닥 난방을 위한 바닥용 건조 시멘트 모르타르의 현장 혼합수량비(W/DM) 변화에 따른 각종 품질특성을 검토한 것이다. 연구결과, 바닥용 건조 시멘트 모르타르의 현장 시공은 현장에서 혼합하는 혼합수량의 증가에 따라 플로가 증가하고, 단위용적질량이 감소하는 일반적인 경향이며, 압축강도 및 건조수축 길이변화율은 혼합수량의 변동에 따라 바닥용 DM의 품질에 크게 영향을 미치기 때문에 적정 W/DM의 관리가 바닥용 DM의 시공 품질 확보에 있어서 매우 중요하다. 따라서, 바닥용 DM의 현장 시공시 작업자의 작업성만을 고려한 과도한 현장 W/DM 증가는 과도한 블리딩 및 재료분리 등으로 인해 바닥용 DM의 경화 후 품질저하를 초래할 수 있으므로 주의가 필요하다. 이상으로, 본 연구 범위의 실험결과를 종합하면, 현장 시공 시 바닥용 DM의 품질확보를 위한 현장 품질관리 기준으로는 W/DM 약 20%가 바람직한 것으로 판단되고, 이를 바탕으로 현장 여건에 따라 적정 혼합수량이 관리될 수 있다면 바닥용 DM의 양호한 품질확보가 가능할 것으로 판단된다.

온돌 바닥용 경량기포콘크리트의 흡수특성 (The Absorption Characteristics of Foamed Concrete for On-dol)

  • 이도헌;전명훈;임정수;정민철;김경덕;민승의
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.225-230
    • /
    • 2001
  • Cast-in-place foamed concrete is a high porous material placed as base the layer of mortar screeds in the panel heating system, so the quality of mortar is affected by it. Therefore, this study is aims to investigate how the absorption characteristics of foamed concrete influences on mortar screeds according to the foamed ratio-62%, 67% and 72%- and the surface treatments of foamed concrete-water and acrylic emulsion primer spray, etc. The result of this study shows that water-spray in the surface of foamed concrete has a good effects to reduce mortar cracking.

  • PDF

공동주택 바닥용 시멘트 모르타르의 복합강화법 변화에 따른 열전도 특성 (Properties of Thermal Conductivity of Cement Mortar for Apartment Housing Floor Using Combined Strengthening Method)

  • 윤길봉;전충근;정성철;윤기원;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.243-248
    • /
    • 2001
  • The objective of this study is to investigate the thermal conductivity of cement mortar for apartment housing floor using expansive admixture, copper fiber, cower lathe, hollowed aluminum plate. According to test results, temperature at point (a) located above heating pipe does not show significant variation with age, and temperature at (b), which is located at the finishing surface above heating pipe, and temperature at (c), which is located at center surface between heating pipe has remarkable change. Temperature distribution sat (b) are in order for, structure containing copper fiber>plain structure>structure containing hollowed aluminum plate>structure containing expansive admixture. Temperature distribution, shows high tendency in order for, structure containing copper fiber>structure containing copper lathe>structure containing hollowed aluminum plate>plain structure>structure containing expansive admixture. (a) estimation of temperature distribution is determined with the variation of temperature between (b) point and (c) point during 60 minutes heating.

  • PDF

이중금속융출형 온돌판넬을 이용한 바닥온수난방시스템의 난방성능과 에너지소비량에 관한 실험적 연구 (Experimental Study on Consumption of Energy and Heating Efficiency in Floor Water Heating System on Using Ondol Panel of Double Metal Rendering)

  • 배대권;김진봉;김환성
    • 한국산학기술학회논문지
    • /
    • 제13권12호
    • /
    • pp.6167-6175
    • /
    • 2012
  • 본 연구는 개발된 온돌판넬을 이용한 바닥난방공법의 품질검증을 위한 실험적 연구이다. 이를 위해 현행기술인 표준바닥구조에 의한 난방시스템과 본 개발기술의 난방성능을 측정비교 하였다. 그 결과, 온수온도 $45^{\circ}C$, 8시간 공급시 개발기술의 몰탈표면부 온도는 $49.4^{\circ}C$, 배관사이 중앙부는 $44.1^{\circ}C$, 공기층은 $25.3^{\circ}C$로 나타났다. 반면, 현행기술의 몰탈표면부는 $46.2^{\circ}C$, 배관사이 중앙부는 $37.7^{\circ}C$, 공기층은 $24.7^{\circ}C$로 나타났다. 한편, 온수온도 $45^{\circ}C$일 때 개발기술의 누적 에너지소비량은 4,646 kcal, 현행기술은 4,814 kcal로써 개발기술이 기존 기술보다 적게 나타났다.

An Experimental Study on the Thermal Performance of Cement Mortar with Granulated PCM

  • Jeong, You-Gun;Park, Ki-Bong;Lee, Han-Seung
    • 한국건축시공학회지
    • /
    • 제12권5호
    • /
    • pp.548-557
    • /
    • 2012
  • In this study the thermal performance of G-PCM replaced for find aggregate in mortar specimens was evaluated using TG-DTA. As a result, it was found that when solid changed into liquid, it absorbed heat, and when liquid changed into solid, it radiated heat. In addition, the fluidity and the compressive strength of mortar with G-PCM can be applied to the floor mortar and a wall finish material. Also the higher the replacement ratio, the larger the latent heat capacity. It was found that the mortar with G-PCM slowed the increase and decrease of temperature. Thus, the duration of pleasant indoor temperature is extended by the floor and wall mortar with G-PCM. In conclusion, G-PCM is expected to reduce the heating energy consumption.

가열온도별 습식방식 폐슬러지를 활용한 모르타르의 특성에 관한 연구 (A Study on the Properties of Mortar using Wet-type Waste Sludge according to Heating Temperature)

  • 강석표;조구영;이준;김창오
    • 한국건설순환자원학회논문집
    • /
    • 제6권1호
    • /
    • pp.111-119
    • /
    • 2011
  • 근래 도시 재개발사업 및 사회기반 시설의 확충 등으로 건설현장에서는 막대한 양의 건설폐기물이 발생량은 매년 증가되는 추세에 있다. 이와 같은 건설폐기물의 처리는 국가, 사회적으로 이슈로 부각되고 있으며, 이중 폐콘크리트의 중간처리 과정에서 발생되는 폐슬러지는 현재까지 유효활용되지 못하고 대부분 폐기 또는 매립되고 있는 실정이다. 따라서 본 연구에서는 건설폐기물 중간처리시설 중 습식방식에 의한 순환골재 생산시 필연적으로 부산되는 폐슬러지를 시멘트 복합체용 사용재료(바인더, 충진재 등)로 활용하기 위한 방안을 모색하기 위하여 순환미분말의 가열온도, 혼입조건, 적용용도별에 따른 모르타르의 물리, 역학적 특성을 검토하였다. 연구결과 모든 가열온도 조건에서 순환미분말의 주성분은 $SiO_2$와 CaO인 것으로 나타났으며, 여기에서 유의할 점은 순환미분말의 CaO 함량은 종래 일반적으로 활용되는 보통 포틀랜드 시멘트에 비하여 작은 함량을 나타냈다. 그리고 건조 및 가열온도 조건별에 따른 모르타르의 유동특성은 가열온도가 증가함에 따라 감소되는 결과를 나타냈고 압축강도 및 기공특성의 경우는 $600^{\circ}C$에서 가장 우수한 특성을 나타냈다. 따라서 건설폐기물 중간처리시설에서 발생되는 순환미분말의 재수화성 부여를 위한 유효 온도조건은 $600^{\circ}C$인 것으로 확인되었다.

  • PDF

균열저감형 바닥마감전용 모르터의 건조수축특성 연구 (A Study on the Dry-Shrinkage Properties For Floor Mortar With Crack-Reducing)

  • 이종렬;이웅종;채재홍;박경상;김기수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.175-180
    • /
    • 1999
  • The heating system of korea apartment house is called Ondol. The surface finishing mortar of this floor system typically used the cement based mortar, where the surface finishing mortar easily appears the crack. To order to crack control, the cement that added expansive additive used to reducing dry-shrinkage. For the surface finishing mortar, the types of shrinkage is known as plastic shrinkage, dry-shrinkage and autogenous This experimental study is to investigate the difference on dry-shrinkage of the cement that added expansive additives and OPC. The test method is varied the ration of water/cement (W/C) and the ratio of sand/cement(S/C). For OPC, The increase of the ratio of S/C is reduced dry-shirnkage but for the cement that added expansive additives, the increase of the ratio of S/C is augmented dry-shrinkage For OPC, The increase of the ratio of W/C is augmented dry-shrinkage but for the cement that added expensive, the increased of the ratio of W/C is reduced dry-shrinkage.

  • PDF

Heavy-impact sound insulation performance according to the changes of dry flooring structure in wall structure

  • Cho, Jongwoo;Lee, Hyun-Soo;Park, Moonseo;Lim, Hohwan;Kim, Jagon
    • 국제학술발표논문집
    • /
    • The 7th International Conference on Construction Engineering and Project Management Summit Forum on Sustainable Construction and Management
    • /
    • pp.89-98
    • /
    • 2017
  • The floor heating method generally uses a wet construction method including the installation of resilient material, lightweight foam concrete, heating piping, and finishing mortar. Such a wet construction method not only delays other internal finishing processes during curing period for two mortar pouring process, but also has a disadvantage that it is difficult to replace the floor heating layer when it deteriorated because it is integrated with the frame. Dry floor heating construction method can be a good alternative in that it can solve these defects. Conversely, when it applied to the wall structure that is vulnerable to the interlayer noise compared with the column-beam structure, the question about the heavy-impact sound(HIS) insulation performance is raised. Therefore, conventional dry floor heating method is hard to apply to the wall structure apartments. Therefore, for the purpose to improve the applicability of dry floor heating method in wall structure apartments, this study investigated the change of floor impact sound, especially HIS insulation performance which is one of the required performance for the floor structure. This study tried to examine whether the change of heavy-impact sound pressure level(SPL) shows a tendency at the significant level according to the shape and mass of the floor structure. Through filed experiments on wall structure apartment, this study confirmed that the form of the raised floor shows better HIS insulation performance than the fully-supported form. In addition, it was also confirmed that the HIS insulation performance increases with the mass on the upper part. Moreover, this study found the fact that a mass of about 30 kg/m2 or more should be placed on the upper structure to reduce the heavy-impact SPL according to the bang machine measuring method. Although this study has a limit due to insufficient experiment samples, if the accuracy of this study is increased, it will contribute to the diffusion of dry floor heating by setting the HIS insulation performance target and designing the dry floor heating structure that meets the target.

  • PDF