• 제목/요약/키워드: heating condition

검색결과 1,304건 처리시간 0.027초

국부 근접 난방 모듈을 이용한 전기차 탑승자의 열쾌적성에 대한 실험적 연구 (Experimental study on Thermal Comfort of Electric Vehicle Occupants Using Local Proximity Heating Module)

  • 이채열 ;임종한;이재욱;박상희
    • 한국산업융합학회 논문집
    • /
    • 제27권3호
    • /
    • pp.655-663
    • /
    • 2024
  • In order to meet the technological demand for indoor heating systems that ensure winter thermal comfort during the transition from internal combustion engines to electrification, a localized proximity heating module using surface heating elements was developed. The operational performance of heating module was tested in the low temperature chamber. The experiment conditions were varied by changing the chamber temperature (-10, 0℃), the air flow rate (6.2, 6.0, 4.2m3/h), the heater power (100, 80, 60, 40W). Thermal comfort model was confirmed using the CBE Thermal Comfort Tool applying ASHRAE standard 55. Under -10℃ condition, thermal comfort was satisfied at 23.4, 23.2℃ at power of 100W and air flow rate 6.0, 4.6m3/h. Under 0℃ condition, at power of 80W, air flow rate 6.2, 6.0m3/h, and at power of 60W, air flow rate 4.6m3/h showed results of 25.7, 26.1, 23.0℃, respectively, satisfying thermal comfort. This study analyzed the operating performance of the local proximity heating module in the low temperature chamber and applied thermal comfort model to prove applicability of local proximity heating module using surface heating elements and how to utilize the thermal comfort model.

가열조건에 따른 링형 구속 콘크리트의 폭렬특성 (Spalling Properties of Ring-Type Restrained Concrete by Heating Conditions)

  • 황의철;김규용;이상규;손민재;백재욱;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.155-156
    • /
    • 2018
  • In this study, surface spalling and explosive spalling of ring-type ultra-high strength concrete under rapid heating and slow heating were investigated. In rapid heating, the internal temperature difference of the concrete is large, so that continuous surface spalling occurs. However, in slow heating, the difference in the internal temperature of the concrete is small, resulting in explosive spalling at a time. Since the heating condition has a great influence on the internal temperature of the concrete, it is necessary to consider the spalling of the concrete under various heating conditions.

  • PDF

바닥난방용 자동온도조절기의 난방방식에 따른 에너지성능 해석용 프로그램에 관한 연구 (Energy Performance Analysis Program with Heating methods of Automatic Thermostatic Valves in Floor Radiant Heating System)

  • 안병천;송재엽;이태원;김용기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.381-386
    • /
    • 2008
  • In this study, the energy characteristic of automatic thermostatic valves according to each heating method in floor radiant heating system were researched by computer simulation. For the analysis of unsteady heat transfer phenomena in household, the method of using electrical equivalent R-C circuit is applied, and radiation heat transfer between panel, ceiling and walls in household is calculated by enclosure analysis method. The parametric study on heating method, valve's control method, outdoor air condition, supply heating water temperature, supply flow rate are performed to compare energy characteristic, respectively.

  • PDF

태양열 시설원예 난방시스템 장기실증 성능분석 연구 (Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy)

  • 이상남;강용혁;유창균;김진수
    • 신재생에너지
    • /
    • 제1권2호
    • /
    • pp.53-59
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a green-house culture facility for reducing healing cost, Increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex In Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely Investigated by changing the control condition based on the temperature difference which Is the most important operating parameter For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, It is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

외경 36mm 강관의 관대관 마찰용접 특성과 공정 변수 최적화 (Mechanical Property and Process Variables Optimization of Tube-to-Tube Friction Welding for Steel Pipe with 36 mm External Diameter)

  • 공유식;박영환
    • 동력기계공학회지
    • /
    • 제18권2호
    • /
    • pp.50-56
    • /
    • 2014
  • Friction welding is a very useful joining process to weld metals which have axially symmetric cross section. In this paper, for the friction welding with tube-to-tube shape, the feasibility of industry application was determined using analyzing mechanical properties of weld and optimized welding variables was suggested. In order to accomplish this object, rotating speed, friction heating pressure, and friction heating time were selected as the major process variables and the experiment was performed in three levels of each parameter. Weld characteristic was investigated in terms of weld shape and metal loss, and 7mm of metal loss was regarded as the optimal metal loss. By tensile test, tensile strength and yielding strength was measured and fracture was occurred at base metal. In order to optimize the welding condition, fitness function was defined with respect to metal loss and yielding strength and the fitness values for each welding condition could be calculated in experimental range. Consequently, we set the optimal welding condition as the point which had maximum value of fitness function. As the result of this paper the optimal welding variables could be suggested as rotating speed was 1300 rpm, friction heating pressure was 15 MPa, and friction heating time was 10 sec.

오징어 연제품의 물성 개선을 위한 탄력증강제 및 용매처리 효과 (Effect of Heating Condition, Additives and Solvents on Rheology of Squid Meat Paste Products)

  • 배태진;김해섭;최옥수
    • 한국식품영양학회지
    • /
    • 제16권2호
    • /
    • pp.130-137
    • /
    • 2003
  • The squid had not been utilized for gel products because of its lower gel forming ability. The objectives of this study were as followed; 1) the optimum heating condition on squid meat paste products and 2) the optimum added level for jelly strength of squid meat paste products. Optimum heating conditions of squid meat kamaboko were as followed; setting(pre-heating) at 15$^{\circ}C$ or 55$^{\circ}C$ for 2 hours and heating at 9$0^{\circ}C$ for 60 minutes. The additives examined were as follows; 20mM EDTA, 10mM PMSF, 5 $\mu$mol/100g TGase, 0.2% potassium bromate, 2% collagen, 2% sucrose ester of stearic acid and 1% egg shell powder. The effects of additives on jelly strength were observed as follow, in descending order; 10mM of PMSF>5 $\mu$mo1/100g of TGase>0.2% of potassium bromate>20mM of EDTA. But sucrose ester of stearic acid and 1% egg shell powder were no effect. The solvents examined were as follows; n-amyl alcohol, n-butyl alcohol, n-hexyl alcohol, ethyl alcohol, ethylene glycol, propylene glycol and glycerin glycol. It showed that high jelly strength as 787gㆍcm for 3% of n-butyl alcohol and 749gㆍcm for 3% of n-amyl alcohol. To adding 5% of n-butyl alcohol and n-amyl alcohol, gave the highest jelly strength and water holding capacity(WHC). Effect of alcohol on jelly strength appeared higher value at added 5% of n-butyl alcohol than n-amyl alcohol, and flying squid product was higher than jumbo squid product.

BES 기법을 이용한 자연환기식 육계사의 난방에너지 분석 (Analysis of Heating Load of a Naturally Ventilated Broiler House using BES Simulation)

  • 홍세운;이인복;홍희기;서일환;황현섭;;유재인;권경석;하태환;김기성
    • 한국농공학회논문집
    • /
    • 제50권1호
    • /
    • pp.39-47
    • /
    • 2008
  • Most of the broiler houses in Korea have experienced problems on controlling the environmental conditions such as suitability, stability and uniformity of rearing condition inside the broiler house. It is very critical which if not properly controlled, would cause serious stress on the chickens. It is therefore urgent to develop optimum designs of naturally ventilated broiler house which is appropriate to the four seasons of Korea. Field experiment for this matter is very difficult to conduct due to the unpredictable and uncontrollable weather condition. In this study, the heating load of a naturally ventilated broiler house was calculated using TRANSYS 15 BES program while internal climate and thermal condition were computed using Fluent 6.2. The computed resulted of the conventional ventilation system (A) and upgraded ventilation system (B) (Seo et al, 2007) were compared with each other for cold season. The results of the Building Energy Simulation(BES) indicated that the system B, the upgraded ventilation system made 8% lower total heating load and 47% lower at only the broiler zone compared to the conventional broiler house. Considering the entire broiler house, the existence of middle ceiling made the heating energy 11% lower required than without middle ceiling. Accordingly, the system B with middle ceiling was found to save heating energy by 20% in average. This study showed that the BES program can be a very powerful to effectively compute the energy loads of agricultural building while the energy load is very close related to ventilation efficiency.

냉난방도일을 이용한 우리나라 주요도시의 도시승온화현상 특성분석 (Analysis of Urban Warming Phenomenon using Degree days in Major Korean Cities)

  • 김해동;박명희;송경숙
    • 한국환경과학회지
    • /
    • 제13권3호
    • /
    • pp.189-196
    • /
    • 2004
  • Characteristics of urban wanning phenomenon were studied using degree days for three big cities(Seoul, Busan, Daegu) adjacent to airport. Time variation of the cooling and heating degree days was analyzed using the daily mean air temperature data measured at the six meteorological observatory for long-term periods(25~43years). The results for the big cities are as followings: 1) It was found that the heating degree days trended to decrease from year to year. 2) The cooling degree days were nearly unchanged during the same analysis periods. 3) The number of days calling for air-heating also tended to decrease as time passes. 4) Those of air-cooling were nearly unchanged during the same time. It suggests that the change of air-heating condition owing to urbanization came in evidence in the winter season, but that of air-cooling condition was slight in the summer season. On the other hand, the long-term trends of degree days were very small in airport areas except for Kimhae airport. Hence, the gaps of degree days between big cities and rural airport areas are increasing.

태양열 온수 및 난방 일체형 복합시스템의 성능예측 (Performance Prediction of a Hot Water Supply and Panel Heating System with Solar Energy)

  • 한유리;박윤철
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.11-17
    • /
    • 2012
  • In this study, a simulation program was developed with heat transfer model in the thermal storage tank for a solar collector and burner combined heating and hot water supply system. Analysis was conducted with variation of operating condition and schedule to analyze performance of a hot water supply and panel heating system with a solar collector and burner combined thermal storage tank. The simulation program is divided two sections. One part is calculation of temperature variation of water which flows through the panel in the floor for heating of the residential house during 24 hours, and the other part is heat transfer calculation for the reaction time to get desired water temperature in the thermal storage tank. As results, light oil consumption and system performance during operation period were analyzed with variation of climate condition and with or without solar collector. Most of the case, oil could be saved about from 24 to 41% with installing the solar collector. The performance of the system is more dependent on radiation time of the solar collector rather than the intensity of the solar radiation which was adopted for the climate analysis.

전기장판의 화재위험성 실험연구 (An Experimental Study on the Fire Hazard of Electric Heating Pad)

  • 이복영;박찬호;박상태;홍성호;유현종
    • 한국화재소방학회논문지
    • /
    • 제20권3호
    • /
    • pp.113-117
    • /
    • 2006
  • 본 연구는 가정용 전열제품인 전기장판에 대한 화재실험과 난연성실험을 통하여 화재위험성을 분석하였다. 화재실험은 정상조건에서 정격전압을 인가하는 경우와 온도조절기 고장시 정격전압이 인가되는 경우를 모델링하였다. 난연성실험은 UL 94의 수직 연소시험방법을 이용하여 전기장판의 난연성능을 평가하였다. 실험에 사용된 전기장판의 종류는 전기매트, 전기요, 비닐장판이다. 실험결과 온도조절기가 고장난 상태에서 정격전압이 인가되는 경우 화재위험성이 높은 것으로 나타났으며 전기장판의 재질은 난연성이 없는 것으로 나타났다.