• Title/Summary/Keyword: heating characteristics

Search Result 2,432, Processing Time 0.023 seconds

Practical Issues on In Situ Heating Experiments in Transmission Electron Microscope (투과전자현미경 내 직접 가열 실험에서의 실험적 문제들)

  • Kim, Young-Min;Kim, Jin-Gyu;Kim, Yang-Soo;Oh, Sang Ho;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • v.38 no.4
    • /
    • pp.383-386
    • /
    • 2008
  • In performing in situ heating transmission electron microscopy (TEM) for materials characterizations, arising concerns such as specimen drifts and unintentional Cu contamination are discussed. In particular, we analysed the thermal and mechanical characteristics of in situ heating holders to estimate thermal drift phenomena. From the experimental results, we suggest an empirical model to describe the thermal drift behavior so that we can design an effective plan for in situ heating experiment. Practical approaches to minimize several hindrances arisen from the experiment are proposed. We believe that our experimental recommendations will be useful for a microscopist fascinated with the powerful potential of in situ heating TEM.

A Study on the Temperature-Diffusion Analysis of Induction Heating Jar (Induction Heating Jar의 온도분포 해석에 관한 연구)

  • Lee, Sang-Ho;Oh, Hong-Seok;Lee, Bong-Seob;Lee, Young-Mee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.79-82
    • /
    • 2002
  • Induction heating is widely used in today's industry, in operations such as metal hardening, preheating for forging operations, melting or cooking. In this paper, it was presented the magneto-thermal analysis of an induction heating jar(IH-JAR) with the material value of the stainless and the aluminum for efficient design. The magnetic field intensity inside the axisymmetric shaped cooker was analyzed using three-dimensional axisymmetric finite element method(FEM) and the effectual heat source was obtained by ohmic losses from eddy currents induced in the jar. The heat was calculated using the heat source and heating equation. Also, it was represented the temperature characteristics of the IH-JAR according to time and relative permeability in stainless parts and in aluminum parts.

  • PDF

A Study on the Fatigue Characteristics at the Weldment by Spot Heating (Spot Heating에 의한 용접부 피로 특성에 관한 연구)

  • Park, Yun-Gi;Kim, Hyeon-Su;Sin, Sang-Beom;Kim, Gyeong-Gyu
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.60-62
    • /
    • 2005
  • The purpose of this study is to evaluate the effect of spot heating on the fatigue strength at the weldment. To do this, the transitional behavior of residual stress at the weld toe induced by spot heating was identified using FEA and experiment. The amount and distribution of residual stress at the weld toe strongly depends on the locations of spot heating. Based on the results, the proper spot heating condition was established. The fatigue strength of the spot-heated specimen increases compared with as-welded specimen.

  • PDF

Design and Analysis of Induction Heating Roll (유도가열 히팅롤의 설계와 해석)

  • Jang, S.M.;Yang, H.S.;Seo, J.H.;Lee, S.H.;Park, H.C.;Park, C.I.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.263-265
    • /
    • 1998
  • This paper presents a design and Analysis of Induction Heating Roll. Heating roll is one of the induction heating's application, widespread for print, pulp, fiber industry, and so forth. In this paper, at first, treated that heating roll's characteristics equation, design method of heating roll, and then design roll. The second, analysis designed roll using FEM.

  • PDF

Effects of Vertical Meteorological Changes on Heating and Cooling Loads of Super Tall Buildings

  • Song, Doosam;Kim, Yang Su
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.2
    • /
    • pp.81-85
    • /
    • 2012
  • Vertical meteorological conditions encountered by super tall buildings, such as wind speed, temperature and humidity, vary due to their height. Therefore, it is necessary to consider these environmental changes to properly estimate the heating and cooling loads, and to minimize the energy demands for HVAC in super tall buildings. This paper aims to analyze how vertical meteorological changes affect heating and cooling loads of super tall buildings by using numerical simulation. A radiosonde, which observes atmospheric parameters of upper air such as wind speed, wind direction, temperature, relative humidity and pressure, was used to provide weather data for the building load simulation. A hypothetical super tall building was used for the simulation to provide quantified characteristics of the heating and cooling loads, comparing the lower, middle and upper parts of the building. The effect of weather data on the heating and cooling loads in super tall building was also discussed.

Effects of Storage Temperatures and Heating Methods on the Textural characteristics of Wheat Flour Gels and Loaf Bread (저장 온도 및 가열 방법이 밀가루겔 및 식빵의 조직 특성에 미치는 영향)

  • 고하영;윤계순
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.28 no.3
    • /
    • pp.566-571
    • /
    • 1999
  • Effects of storage temperature at 18oC and 5oC for 9 days and heating conditions on textural char acteristics in strong wheat flour gels were investigated using a Instron after microwave (2450MHz, 700W). Heating condition did not affect the texture property in the wheat flour gels, but the frozen storage was very effective to prevent the hardening of the samples. Hardness, adhesiveness, and gumminess in the wheat flour gels decreased in increasing moisture content from 45% to 55%, but there was little change in cohesiveness. The storage at room temperature for 2 hours resulted in increased hardness in the heated wheat flour gels. PE wrap package of the wheat flour gels prevented weight loss by 3~6% and hardening effectively. Sugar, or sugar and shotening resulted in increased hardness in loaf bread. The hardness and weight loss in loaf breads were markedly changed by the heating time with microwave. The most critical time point was around 4 minutes following the heating.

  • PDF

Analysis of surface-hardening Induction heating (파열물의 표면 열처리를 위한 유도가열의 특성해석)

  • Jang, S.M.;Yoon, I.K.;Lee, S.H.;Ryu, D.W.;Choi, P.I.;Lee, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.287-289
    • /
    • 2000
  • Induction heating is utilized in a large and ever-increasing number of application. The most prominent of these are billet heating heat treating, metals joining, and metal melting. In these day, heating roll, a kind of induction heating, is widely used in curing of coatings and fiber industry. In this paper, at first, treated that heating roll's characteristics equation. The second, analysis of magnetic flux and eddy currents distribution using FEM.

  • PDF

Viscosity Characteristics of Waste Cooking Oil with Ultrasonic Energy Irradiation

  • Kim, Tae Han;Han, Jung Keun
    • Journal of Biosystems Engineering
    • /
    • v.37 no.6
    • /
    • pp.429-433
    • /
    • 2012
  • Purpose: While rapeseed oil, soy bean oil, palm oil and waste cooking oil are being used for biodiesel, the viscosity of them should be lowered for fuel. The most widely used method of decreasing the viscosity of vegetable oil is to convert the vegetable oil into fatty acid methyl ester but is too expensive. This experiment uses ultrasonic energy, instead of converting the vegetable oil into fatty acid methyl ester, to lower the viscosity of the waste cooking oil. Methods: For irradiation treatment, the sample in a beaker was irradiated with ultrasonic energy and the viscosity and temperature were measured with a viscometer. For heating treatment, the sample in a beaker was heated and the viscosity and temperature were measured with a viscometer. Kinematic viscosity was calculated by dividing absolute viscosity with density. Results: The kinematic viscosity of waste cooking oil and cooking oil are up to ten times as high as that of light oil at room temperature. However, the difference of two types of oil decreased by four times as the temperature increased over $83^{\circ}C$. When the viscosity by the treatment of ultrasonic energy irradiation was compared to one by the heating treatment to the waste cooking oil, the viscosity by the treatment of ultrasonic energy irradiation was lower by maximum of 22% and minimum of 12%, than one by the heating treatment. Conclusions: Ultrasonic energy irradiation lowered the viscosity more than the heating treatment did, and ultrasonic energy irradiation has an enormous effect on fuel reforming.

Energy Consumption Characteristics and Evaluation of Thermal Insulation Performance in Accordance with Built Year of Apartment Complex (공동주택의 준공연도에 따른 단열성능 평가 및 에너지소비 특성에 관한 연구)

  • Choi, Doo Sung;Lee, Myung Eun;Chun, Hung Chan
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.79-86
    • /
    • 2014
  • Studies have shown that the thermal performance of buildings changes depending on the year of construction completion. It leads to increased energy consumption of buildings and significant financial burden on users. Thus, this study has calculated the thermal insulation performance of 86 apartments quantitatively, using temperature difference ratio and sensible heat flux. Also, energy consumption characteristics depending on the year of construction completion and thermal insulation performance were analyzed by comparatively analyzing the results of insulation performance evaluation and heating costs. The analysis results are as follows. As for thermal insulation performance, it was around 70% lower in the apartments completed before 1985, compared to apartments completed after 2010. As for heating costs, the apartments with the highest heating cost incurred 1.5 higher heating cost than the apartment with the lowest heating cost. In terms of the insulation performance evaluation, the difference was 2.5-fold.

Performance Characteristics of a CO2 Cooling and Water Heating System with a Twin-rotary Compressor (트윈로터리 압축기 적용 냉방 및 급탕 겸용 이산화탄소 시스템의 성능특성에 관한 연구)

  • Cho, Hong-Hyun;Lee, Ho-Sung;Baek, Chang-Hyun;Kim, Yong-Chan;Cho, Sung-Wook
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.230-237
    • /
    • 2008
  • The objective of this paper is to investigate the performance characteristics of a $CO_2$ cooling and water heating system using a twin-rotary compressor with the compression volume ratio of 0.6. The cooling performances of the $CO_2$ heat pump were measured and analyzed with the variations of charge amount, EEV opening, and compressor frequency. In addition, the performance of the combined system including cooling and water heating was also measured and analyzed by varying inlet temperature of the EEV. As a result, the optimal normalized charge and cooling COP in the cooling mode were 0.307 and 2.06, respectively. The application of the water heating into the $CO_2$ heat pump improved the cooling performance over 78% and decreased the EEV inlet temperature by $8^{\circ}C$, which can increase system reliability.