• Title/Summary/Keyword: heat storage rate

Search Result 319, Processing Time 0.023 seconds

Analysis for DME FPSO Storage Tank and Experimental Study on the DME Evaporation Rate by Rolling Motion of Ship (DME FPSO선박의 탱크해석 및 Rolling 유동에 따른 증발 실험연구)

  • Yun, Sangkook;Cho, Wonjun;Baek, Youngsoon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.8
    • /
    • pp.1010-1015
    • /
    • 2012
  • DME(Dimethyl ether) is the one of the massive energy sources synthesized from natural gas. KOGAS has already developed the commercial-scale production plant of DME and has been doing to obtain overseas resources to meet the domestic needs. This paper presents the DME storage tank design criteria by stress and strain analysis, and the experimental study on the evaporation phenomena of DME by thermal intake and physical rolling movement of DME FPSO or cargo vessel, because the various moving motions along with heat intake cause the evaporation of low temperature liquid. The experimental result shows that the evaporation rate was increased with larger rolling degree and higher liquid level. The rolling motion leads to evaporate about 20% increase with 15 degree rolling based on the evaporation quantity without rolling.

Early-age thermal analysis and strain monitoring of massive concrete structures

  • Geng, Yan;Li, Xiongyan;Xue, Suduo;Li, Jinguang;Song, Yanjie
    • Computers and Concrete
    • /
    • v.21 no.3
    • /
    • pp.279-289
    • /
    • 2018
  • Hydration heat and thermal induced cracking have always been a fatal problem for massive concrete structures. In order to study a massive reinforced concrete wall of a storage tank for liquefied natural gas (LNG) during its construction, two mock-ups of $0.8m{\times}0.8m{\times}0.8m$ without and with metal corrugated pipes were designed based on the actual wall construction plan. Temperature distribution and strain development of both mock-ups were measured and compared inside and on the surface of them. Meanwhile, time-dependent thermal and mechanical properties of the concrete were tested standardly and introduced into the finite-element (FE) software with a proposed hydration degree model. According to the comparison results, the FE simulation of temperature field agreed well with the measured data. Besides, the maximum temperature rise was slightly higher and the shrinkage was generally larger in the mock-up without pipes, indicating that corrugated pipes could reduce concrete temperature and decrease shrinkage of surrounding concrete. In addition, the cooling rate decreased approximately linearly with the reduction of heat transfer coefficient h, implying that a target cooling curve can be achieved by calculating a desired coefficient h. Moreover, the maximum cooling rate did not necessarily decrease with the extension of demoulding time. It is better to remove the formwork at least after 116 hours after concrete casting, which promises lower risk of thermal cracking of early-age concrete.

Effects of Mild Heat Treatment on Microorganisms, Respiratory Characteristics and Firmness of Fuji Apple (중온 열수 처리가 사과의 표면 미생물, 호흡특성 및 경도에 미치는 영향)

  • Seo, Ja-Young;Kim, En-Jeong;Hong, Seok-In;Yu, Sung-Hun;Kim, Dong-Man
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.1
    • /
    • pp.47-51
    • /
    • 2006
  • Microorganisms involved in decaying Fuji apples during storage were investigated. Seven pathogens were isolated from the rotted fruits. Penicillium spp. was derived from 65-75% of decayed apples with P. expansum being dominant species. Effects of mild heat treatment on microbial reduction, respiration, and texture characteristics in Fuji apples were examined through hot water dipping at $40-65^{\circ}C$ for varied timε periods. Initial counts of total microorganisms and moulds in fresh fruits s showed 4.75 and 4.66 log CFU/g in a stem, as well as 5.35 and 4.32 log CFU/g in a calyx, respectively. The heat treatment at $40^{\circ}C$ for 180 min significantly reduced the population of total microorganisms and moulds in the fruits. Respiration rate of the apple fruits increased immediately after heat treatment and then returned to the normal level during storage. The rates of ethylene production in the fruits treated at $40-50^{\circ}C$ were maintained lower than that of the untreated control. The fruits treated at $40^{\circ}C$ showed slightly greater flesh firmness than the other apple samples during storage.

Design of the Hybrid Optical Pickup Actuator by Numerical Simulation of Heat Transfer (열전달 수치해석에 의한 하이브리드 광픽업 액추에이터의 설계)

  • Shin, Su-Ho;Lee, Jin-Won;Cheong, Young-Min;Kim, Kwang
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.798-800
    • /
    • 2003
  • Recently, in optical storage device technical trends, the size of optical drive is slimmer to adopt notebook computer and the power of actuator is higher to achieve the high transfer rate. However, these trends of optical disc drives tend to increase the temperature of the actuator part, it causes some problems on the performance of optical parts - the resonance frequency of the actuator is down to lower band and the objective lens, coil and magnet are easily damaged. In this study, to overcome these thermal problems, the numerical simulations of heat transfer were performed. As the result of simulations, the thermal characteristic of the hybrid actuator is better than the previous design. And, it shows the good dynamic performance in experiment.

  • PDF

Evaluation of Long-term Performance of Metal Seal Through Accelerated Test (가속화 시험을 통한 금속 밀봉재 장기성능 평가)

  • Choi, Woo-seok;Lim, Jongmin;Yang, Yun-young;Cho, Sang Soon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.237-245
    • /
    • 2020
  • Metal seals are the main components that establish the containment boundary in bolted casks, which store spent nuclear fuel. These seals are degraded by heat and radiation. In addition, creep occurs when the seals are exposed to intense heat for an extended period. This creep results in the stress relaxation of the seals, which consequently impairs the seal integrity. The stress relaxation can reduce the sealing performance of the metal seal, which can further cause leakage in the storage cask. Moreover, the reduction of bolt tension leads to sealing performance degradation. In this study, the results of high-temperature-accelerated tests were obtained to evaluate the containment integrity of metal seals and the decrease in bolt tension. During the tests, the leakage rate, bolt strain, and ambient temperature of the metal seals were measured and analyzed. The metal seals were found to maintain containment integrity for 50 years of storage. The validity of the acceleration test was also investigated.

Characteristic of the Formation and Adhesion of Ice on a Cooling Surface by a Stirring Aqueous Solution

  • Kang, Chae-Dong;Seung, Hyun;Hong, Hi-Ki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.3
    • /
    • pp.110-117
    • /
    • 2006
  • Ice adhesion or cohesion leads to the decrease of the performance of ice making system, especially to dynamic type ice thermal storage system (DISS) which mainly forms ice from the flow of an aqueous solution. The ice adhesion is influenced by various parameters associated with operating or geometric condition. In this study, the influence on an adhesion of ice to the characteristic of cooling surface and to composition of an aqueous solution was fundamentally observed by using batch type cooling device,. a beaker. Three patterns of solution in each beaker were cooled with brine. Moreover, the characteristic of cooling surface on each beaker was distinguished to coating materials. Stirring power as a degree of the ice adhesion was measured. The stirring power to cooling heat transfer rate in each beaker was compared. As a result, the lowest stirring power of 8.9 W with non-adhesion of ice, was shown in the case of the aqueous solution of EG(4) + PG(1.5) + 1,6HD(1.5). in PE coating beaker.

A study on the Application Effect of Friction Stir Processing for Enhanced Pitting Corrosion Resistance of Stainless Steel Welds in Chloride Environment (염화물 환경에서 스테인리스강 용접부의 공식저항성 향상을 위한 마찰교반공정 적용효과에 관한 연구)

  • Jong Moon Ha;Deog Nam Shim;Seung Hyun Kim
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.19 no.2
    • /
    • pp.84-92
    • /
    • 2023
  • As temporary storage facilities for spent nuclear fuels in domestic nuclear power plants are expected to be saturated, external intermediate storage facilities would be required in the future. Spent nuclear fuels are stored in metal canisters and then placed in a dry environment within concrete or metal casing for operation. In the United States, the dry storage method for spent nuclear fuels has been operated for an extended period. Based on the corrosion experiences of dry storage canisters in chloride environments, numerous studies have been conducted to reduce corrosion in welds. With the construction of intermediate storage facilities in Korea for spent nuclear fuels expected near coastal areas adjacent to nuclear power plants, there is a need for research on the corrosion occurrence of welds and mitigation methods for canisters in chloride environments. In this paper, we measured and compared the residual stresses in the Heat-Affected Zones (HAZ) after electron beam welding (EBW) and gas tungsten arc welding (GTAW) processes for candidate materials such as 304L, 316L, and duplex stainless steel(DSS). We investigated the possibility of microstructure control through the application of surface modification processes using friction stir processing (FSP). Corrosion tests on each welded specimen revealed a higher corrosion rate in EBW welds compared to GTAW. Furthermore, it was confirmed that corrosion resistance improved due to phase refinement and redistribution of precipitates when FSP was applied.

The Properties of Concrete with Lightweight Aggregate Impregnated by Phase Change Material (상변화물질 함침 경량골재를 사용한 콘크리트의 특성)

  • Kim, Se-Hwan;Jeon, Hyun-Kyu;Hwang, In-Dong;Seo, Chee-Ho;Kim, Sang-Heon
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.3
    • /
    • pp.331-338
    • /
    • 2013
  • Under the paradigm of sustainable green growth at the national level, various researches and applications for energy saving in the construction field has been attempted. As a part of energy saving efforts, lightweight concrete was investigated for thermal insulation concrete with phase change material (PCM) which has high heat storage capacity. As a part of energy saving efforts, thermal insulation concrete was investigated and evaluated with lightweight aggregate impregnated by PCM which has high heat storage capacity. As a result, it is found that concrete with lightweight aggregate impregnated by PCM is effective to prevent its quality deterioration by reducing water absorption rate of lightweight aggregate. In addition, it has shown that concretes using lightweight aggregate and impregnated lightweight aggregate improve heat insulation property 33% and 40~43% compared with using normal aggregate, respectively. It is that the lightweight aggregate concrete with impregnated lightweight aggregate has 12~14% lower thermal conductivity than unimpregnated.

Effects of Heat Pretreatment on the Quality under Storage of Fresh Ginger Rhizomes (저장 전 열처리가 생강의 이화학적 및 관능적 특성에 미치는 영향)

  • Chung, Hun-Sik;Lee, Hyeon-Jeong;Seong, Jong-Hwan;Moon, Kwang-Deog
    • Food Science and Preservation
    • /
    • v.16 no.5
    • /
    • pp.623-628
    • /
    • 2009
  • Fresh ginger rhizomes were heat-treated for 10 min, 30 min, or 60 min using hot air ($40^{\circ}C$, $50^{\circ}C$, or $60^{\circ}C$), and stored in low-density polyethylene (0.04 mm thickness) bags for 2 months at $12{\pm}1^{\circ}C$. We studied the effects of heat pretreatment on changes in gas levels after packaging, and quality characteristics of the rhizomes. Oxygen and carbon dioxide levels progressively fell and rose, respectively, as the temperature of heat treatment rose and the duration of such treatment was extended. The sprouting rate of ginger rhizomes treated at $40^{\circ}C$ was higher than that of other samples. Rotting, softening, and increasing pH of rhizomes were accelerated by treatment at higher temperature for a longer time. Weight loss and soluble solid levels were not affected by heat treatment. Sensory qualities such as appearance, odor, and overall acceptability of rhizomes fell with treatment at a higher temperature for a longer time. These results suggest that heat pretreatment has a detrimental effect on the quality of fresh ginger rhizomes.

Life cycle cost analysis and smart operation mode of ground source heat pump system

  • Yoon, Seok;Lee, Seung-Rae
    • Smart Structures and Systems
    • /
    • v.16 no.4
    • /
    • pp.743-758
    • /
    • 2015
  • This paper presents an advanced life cycle cost (LCC) analysis of a ground source heat pump (GSHP) system and suggests a smart operation mode with a thermal performance test (TPT) and an energy pile system constructed on the site of the Incheon International Airport (IIA). First, an economic analysis of the GSHP system was conducted for the second passenger terminal of the IIA considering actual influencing factors such as government support and the residual value of the equipment. The analysis results showed that the economic efficiency of the GSHP system could be increased owing to several influential factors. Second, a multiple regression analysis was conducted using different independent variables in order to analyze the influence indices with regard to the LCC results. Every independent index, in this case the initial construction cost, lifespan of the equipment, discount rate and the amount of price inflation can affect the LCC results. Third, a GSHP system using an energy pile was installed on the site of the construction laboratory institute of the IIA. TPTs of W-shape and spiral-coil-type GHEs were conducted in continuous and intermittent operation modes, respectively, prior to system operation of the energy pile. A cooling GSHP system in the energy pile was operated in both the continuous and intermittent modes, and the LCC was calculated. Furthermore, the smart operation mode and LCC were analyzed considering the application of a thermal storage tank.