• Title/Summary/Keyword: heat release

Search Result 1,076, Processing Time 0.021 seconds

Combustion Characteristics Analysis of a Non-class 1E Cable for Nuclear Power Plants according to Aging Period (경년열화 기간에 따른 원자력발전소용 비안전등급 케이블의 연소특성 분석)

  • Kim, Min Ho;Lee, Seok Hui;Lee, Min Chul;Lee, Sang Kyu;Lee, Ju Eun
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.5
    • /
    • pp.22-29
    • /
    • 2020
  • In this study, combustion and smoke release characteristics of a non-class 1E cable for nuclear power plants were investigated according to aging period. The aging was reproduced through an accelerated aging method for interval of 10 years :10, 20, 30 and 40 year, which was applied the Arrhenius equation. The cable was subjected to accelerated aging. In order to understand combustion and smoke release characteristics, the cone calorimeter test was performed according to the standard code of KS F ISO 5660-1. Heat release rate, mass loss rate, average rate of heat emission and smoke production rate were examined through cone calorimeter test. Fire performance index, fire growth index and smoke factor were derived from test results for the comparison of quantitative fire risk. When comparing the fire performance index and the fire growth index, the early fire risk tends to decrease as aging progresses, which might be attributed from the fact that the volatile substances of cables were evaporated. However, when comparing the heat release rate, average rate of heat emission and mass loss rate, which represent the mid and late periods of the fire risk, the values of accelerated aging cables were much higher than those of non-aged cable, which signifies the unstable formation of the char layer resulted in the change in the performance of flame retardants. In addition, the results from the smoke characteristics show that the accelerated aging cables were lager than the non-aged cables in terms of overall fire risk. These results can be used as baseline data when assessing fire risk of cables and establishing fire safety code for nuclear power plants.

The Relationship between Flash Point and Fire Properties of Flammable Liquids (가연성 액체의 인화점과 화재특성치와의 관계)

  • Song, Young-Ho;Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.2 s.35
    • /
    • pp.10-14
    • /
    • 2007
  • Flash point is one of the major physical properties used to evaluate fire hazards of the combustible liquids. Properties showing relative fire hazards of the combustible liquids are heat release rate(HRR), peak heat release rate(PHRR), time to ignition(TTI), mass loss rate, and yield of $CO/CO_2$. The relationships between flash points and fire properties of the combustible liquids were examined in this study. For this study, mass loss rate and time to ignition were measured to calculate fire properties of the combustible liquids. The results showed that good correlations could be found between flash point and time to ignition, time to peak heat release rate, and the propensity to flashover. From a presented results, the parameters can be used to evaluate relative hazards of the combustible liquids on fire.

  • PDF

A Study on the Wigner Energy Release Characteristics of Irradiated Graphite of KRR-2 (연구로 2호기 중성자 조사 흑연의 Wigner 에너지 방출 특성 연구)

  • Jeong Gyeong-Hwan;Yun Sei-Hun;Lee Dong-Gyu;Jung Chong-Hun;Lee Keun-Woo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.3
    • /
    • pp.209-216
    • /
    • 2006
  • Characteristics of heat release process, while the Wigner energy was drawn off the graphite during DSC(Differential Scanning Calorimenter) measurement as an example of annealing process which is one of release methods of Wigner energy that is contained in the irradiated graphite, was studied. Linear temperature rise method in DSC operation was selected to estimate the total Wigner energy content and the heat release rate of each graphite samples, which were located in several positions in the thermal column in KRR-2 research reactor. As an annealing process in DSC operation Wigner energy of the irradiated graphite samples were totally released by heat supplying to the graphite from room temperature to $500^{\circ}C$, in DSC. Characteristics of Wigner energy release from the graphite sample was well correlated with the various activation energy model of the kinetic equation.

  • PDF

The Characteristics of Combustion for Living Leaves in Quercus variabilis with Monthly Seasonal Variations (굴참나무 생엽의 월별 연소특성에 관한 연구)

  • Park, Young-Ju;Oh, Jin-Youl;Lee, Si-Young;Lee, Hae-Pyeong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.85-90
    • /
    • 2010
  • In this study, we have examined the monthly combustion characteristics of Quercus variabilis, a representing Quercus Spp. in Korea, using its living leaves over the period of from June to October. As a result, we were able to identify that their moisture content was about 114%~155%. The leaves of Quercus variabilis collected in October showed the lowest moisture content and nonflaming ignition temperature. The leaves of July showed the fastest flaming ignition time of 27s while those from September showed the longest persistence of flame with 105s, and also showed the highest total heat release amount. There was a noticeable difference in each month of the above period regarding total heat release amount and total smoke release amount with a gradual increase from June to October. The maximum smoke density was a bit higher in October leaves but there was no significant monthly difference. In addition, July leaves were shown to reach the maximum value in the shortest time of 795s.

A Study on the Release Characteristics of VOCs from Heat Recovery Ventilation System (폐열회수형 환기장치의 휘발성유기화함물 배출 특성에 관한 연구)

  • Kwak, Kyung-Min;Bai, Cheol-Ho;Kim, Jee-Yong;Chu, Euy-Sung
    • Clean Technology
    • /
    • v.13 no.4
    • /
    • pp.281-286
    • /
    • 2007
  • VOCs from the heat recovery ventilation system (total heat exchanger) are measured in this study. Two different types of element (L and M type) from heat recovery ventilating system are tested to study the intial release characteristics of VOCs under KS cooling and heating standard conditions. VOCs are measured for the various flow rates and different operating times. Considering errors in the test method and the measuring instrument, the tested heat recovery ventilating systems was found to release 6 major VOCs, such as acetic acid, 2-butanone (MEK), 2-(methylthio )ethylamine, toluene, styrene, and x-acids (Ion 57). The concentrations of released VOCs are not quite much affected by operating conditions. The results show much larger VOCs concentrations in the cooling mode than in the heating mode, due to the high operating temperatures.

  • PDF

Analysis on the Effects of the Heat Loss Coefficient on the Operation Time of Sprinkler in Compartment Fire (구획 화재에서 스프링클러 열 손실계수 변화에 따른 작동 시간 분석)

  • You, Woo Jun
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.34-39
    • /
    • 2018
  • In this study, the experiment conditions for the variation of heat release rate in compartment space were constructed to analyze the effects of fire spread and the operation time of sprinkler in accordance with the heat loss of the sprinkler's heat element. The compartment composed of fire board (width = 0.3 m, height = 0.5 m, length = 3.0 m), are manufactured to measure the temperature distributions in the inner space, the mass loss rate and heat release rate during the experiment of N-heptane pool fire test. Also, the operation time of sprinkler is analyzed with the installation of sprinkler and C-factor using Fire Dynamics Simulator Ver.6 under the experiment conditions. The results show that the operation time of sprinkler, which has RTI $100(m{\cdot}s)^{0.5}$ operating temperature $70^{\circ}C$, is 30 s~60 s for C-factor = 0 and 1, 62 s~92 s for C-factor = 3, and 120 s over for C-factor = 5, respectively.

Evaluation of Heat Release Performance of Swaged- and Extruded-type Heat Sink Used in Industrial Inverter (산업용 인버터에 사용되는 압입식 및 압출식 히트싱크의 방열 성능 평가)

  • Kim, Jung Hyun;Ku, Min Ye;Lee, Gyo Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.523-528
    • /
    • 2013
  • In this experiment, we investigated the performance of two types of heat sink, swaged- and extruded-type, used in the inverter of industrial electricity generator. The swaged-type heat sink has 62 fins, and the extruded-type has 38 fins having the same dimension as that of the swaged-type. But the extruded-type heat sink maintains the same heat transfer area by the laterally waved surface which has 1 mm in radius. As a result, the swaged- and extruded-type heat sinks released 70.7% and 63.8% of the heat incoming to the heat sink, respectively. The other incoming heat were naturally convected and radiated to the ambient. In spite of 40% decrease in number of fins, the heat release performance of the extruded-type heat sink was lowered only 6.9% than that of the swaged-type. We believe that, this shows the increment of effective heat transfer area by the laterally waved surface of fins and the better heat transfer property of the extruded-type heat sink.

A Comparison of the Immediate Effects of Alternate Methods to Medication in Lowering the Blood Pressure in Prehypertensive Patients

  • Moon, Hyun-Ju;Cho, Sung-Hak
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.3
    • /
    • pp.201-204
    • /
    • 2016
  • Purpose: The purpose of this study was to compare the immediate effects of alternative treatment methods in lowering the blood pressure and pulse of prehypertensive patients. Methods: A total of 48 prehypertensive patients were randomly divided into 4 groups of 12 patients and each group received a different intervention. The control group was made to rest, the heat pack (HP) group received heat pack treatment, the ultrasound (US) group received an ultrasound massage, and the myofascial release (MFR) group received myofascial release. The blood pressure and pulse rate were measured before and after intervention. Results: Following intervention, the patients of the MFR group showed a decrease in systolic pressure, diastolic pressure, and pulse rate. Although blood pressure was similar in all groups, a significant decrease in pulse rate was seen in the MFR group compared to others. Conclusion: The application of MFR was shown to be an effective method for lowering the blood pressure and pulse rate in prehypertensive patients.

방열기판 전극형성 기술 동향

  • Kim, Dan-Bi;Kim, Ji-Won;Eom, Nu-Si-A;Im, Jae-Hong
    • Ceramist
    • /
    • v.21 no.2
    • /
    • pp.83-88
    • /
    • 2018
  • There is close relation between the heat generation and the performance of electronic device. The durability and efficiency of the device are degraded due to heat generation. It is necessary to release the generated heat from an electronic device. Based on demands of the printed circuit board (PCB) manufacturing, the robust and reliable plating technique of PCB is necessary. In this study, we review various methods for improving the heat sink property. These methods were considered to enhance the adhesion between ceramic substrate as heat sink and metal layer as electrode.

A Study on the Shape Design of a Radiator Panel for Effective Heat Release (효율적인 열 방출을 하기 위한 방열판의 형상 설계에 관한 연구)

  • Han, Moonsik;Cho, Jaeung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.5
    • /
    • pp.25-30
    • /
    • 2016
  • This study investigates the heat transfer due to a change in the shape of a radiator panel inside a computer. As with models of radiator panels, models have the same surface areas. As the gap between heat transfer surfaces in model 1 becomes wider than those in model 2, the heat transfer at model 1 becomes smoother than that of model 2. By comparing the cooling processes between models 1 and 2 with respect to natural convection, a maximum temperature of $47.432^{\circ}C$ at model 1 becomes lower than that of model 2, at $49.821^{\circ}C$. Within the radiator panel, model 1 has been shown to be more effective than model 2. Accordingly, these results can be effectively applied to the shape design of radiator panels to imbue them with smoother and faster heat transfer through the finite element method.