• 제목/요약/키워드: heat pump system

검색결과 1,120건 처리시간 0.025초

유압 블리드-오프 회로의 특성 재검토 및 실험적 동특성 모델링 (Reexamination and Derivation of Empirical Dynamic Model for a Hydraulic Bleed-Off Circuit)

  • 정헌술;이광헌;김형의
    • 대한기계학회논문집A
    • /
    • 제26권8호
    • /
    • pp.1552-1564
    • /
    • 2002
  • Meter-in, meter-out and bleed-off circuits are widely utilized in order to adjust the speed of a hydraulic actuator by using a flow control valve and in order to regulate the pressure of a hydraulic volume by using a simple on-off valve. In these circuits, a relief valve serves either to maintain constant system pressure or to protect the system from over-pressure loading. The relief valve of a bleed-off circuit is the second case frequently undergoing on-off action during operation. It makes the analysis of the pressure control characteristics of the circuit highly difficult. In this paper, steady-state flow rate, pressure, heat loss and efficiency of the three circuits are reexamined and basic experiments far obtaining the characteristics of a pump and relief valve are conducted. Finally, simple empirical first-order dynamic models of decreasing and increasing pressure were separately proposed and verified by comparison with experiment. As the result, the basis for the theoretical analysis of the pressure control characteristics of a bleed-off circuit using a simple on-off valve is established.

몰입형 인터페이스를 위한 햅틱 마우스 (A Haptic Mouse for an Immersive Interface)

  • 김다혜;조성만;김상연
    • 한국멀티미디어학회논문지
    • /
    • 제14권9호
    • /
    • pp.1210-1220
    • /
    • 2011
  • 본 논문에서는 PC 상의 가상환경과 사용자간의 몰입형 상호작용 인터페이스로서 햅틱 마우스 시스템을 제안한다. 제안하는 햅틱 마우스는 진동감각 및 온열감을 제공하여 몰입감을 높인다. 진동 모듈은 편심모터와 솔레노이드 액추에이터로 구성하였으며 온열감 모듈은 작은 필름형태의 온도 센서와 펠티어 효과기반의 열 펌프를 이용하여 구축한다. 본 햅틱 마우스 시스템의 효용성을 보이기 위해 레이싱 게임 어플리케이션을 제작한 후 이를 사용하여 실험을 수행한다. 실험 결과로부터 제안하는 햅틱 마우스가 가상환경에서 몰입감을 증가시키며 가상환경과 사용자간의 효과적인 인터페이스로 사용될 수 있음을 증명한다.

원전 급수펌프 구동용 터빈 제어시스템 개발 (A Development of Digital Control System for FWPT In Nuclear Power Plant)

  • 최인규;정창기;김병철;김종안;우주희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.1885-1886
    • /
    • 2006
  • The thermal energy from nuclear fission is transferred to the steam generator which is a kind of a large heat exchanger. After the feedwater is injected into the steam generator and absorbs the thermal energy, it is converted into the steam. This steam goes into the turbine. The balance between the generated energy and the consumed energy is required for the nuclear power plant to be stable. For the purpose of which, the feed water, a parameter for energy transfer, should be controlled in stability. Usually, the nuclear power plants are operated in base load in the view of power system for the stability of fission system. Therefore, though there will be almost no unbalance, there can be some instability from unbalance in case of startup/shutdown or disturbance. In this case, the controllability of feedwater pump is very important for the quick recover of stability.

  • PDF

파사드 일체형 자연순환 태양열온수기 유동해석 (Flow Analysis of Facade Integrated Solar Water Heater with Natural Circulation)

  • 백남춘;이왕제;임희원;신우철
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.167-172
    • /
    • 2016
  • Purpose: The solar water heater with natural circulation has been used for several decades in the world as it is automatically operated without a pump and controller and is easy to maintain and repair. After the subsidy was offered from 2012, the solar water heater with natural circulation is becoming increasingly popular in Korea. Recently, the development of a wall-integrated solar water heater, which improves the applicability of buildings and prevents the overheating in the summer, is being developed. On the other hand, the design and performance evaluation data of solar water heaters are very inadequate, and analysis of heat and flow is required to develop a new type of solar water heater. Method: Therefore, in this study, we proposed a new simplified system analysis model that reflects heat and pressure loss from the test results of KS B ISO 9806-1 (Solar collector test method), assuming that the collector is a simple pipe system, the validity of which was verified through experiments. Result: As a result, first, the RMSE of the system circulation flow rate and the average temperature of the inlet and outlet of the collector according to the experimental results and the simulation are 0.05563 and 0.88530, respectively, which are very consistent. Secondly, the mass flow rate is increased linearly with the increase of the solar radiation, and the mass flow rate is 0.0104 ~ 0.0180kg/s in the range of $200{\sim}380W/m^2$ of solar irradiance. Compared with the test flow rate 0.0764kg / s of the test collector, it showed a level of less than 20%.

1kW급 유기랭킨사이클용 스크롤 팽창기의 성능 특성에 관한 실험적 연구 (Experimental Study on the Performance Characteristics of a Scroll Expander for 1kW-class Organic Rankine Cycle)

  • 김도균;윤은구;윤상열;김경천
    • 한국가스학회지
    • /
    • 제19권4호
    • /
    • pp.41-48
    • /
    • 2015
  • 스크롤 팽창기의 성능특성은 유기랭킨사이클 (ORC) 시스템의 성능에 가장 중요한 변수이다. 본 연구에서는 1kW급 ORC 시스템을 구성하여 다양한 작동 조건에서 스크롤 팽창기의 성능특성을 파악하였다. ORC 시스템은 증발기, 스크롤 팽창기, 응축기, 작동유체펌프로 구성되어 있으며, 작동유체로 R245fa를 사용하였다. 고온수 온도는 50kW급 전기히터에 의해 $80^{\circ}C$에서 $115^{\circ}C$까지 제어되었다. 스크롤 팽창기의 최대 등엔트로피 효율은 77%로 측정되었고, ORC 시스템의 축동력은 열원의 온도 조건 및 팽창기의 회전속도에 따라 0.5kW에서 1.8kW까지 측정되었다.

HVAC 상실사고시 울진원전 3/4 호기의 보조급수펌프 격실 온동상승 평가 (Heat-up Calculation for the Auxiliary Feed Water Pump Room at Ulchin Units 3 and 4 for Loss of HVAC Accidents)

  • 윤철;박진희;황미정;한상훈
    • 대한기계학회논문집B
    • /
    • 제36권5호
    • /
    • pp.553-562
    • /
    • 2012
  • 난방, 환기 및 공기조절(HVAC) 기능이 상실된 사고의 경우, 보조급수를 위한 모터-구동 펌프격실의 온도상승을 전산유체역학 분석을 통해 평가하였다. 닫힌 펌프격실의 과도 계산결과, 8 시간 동안 공간-평균된 공기온도는 $60^{\circ}C$ 정도의 상승이 예상된다. 외기 온도 및 외부 온도는 이전 계산결과로부터 초기 $35^{\circ}C$에서 시작하여 서서히 증가한다고 가정하였다. 격실 문이 사고발생 후 약 2, 4, 그리고 6시간 경과 시점에서 열릴 경우, 체적-평균 격실 내가 온도는 약 $4^{\circ}C$의 즉각적인 하강이 나타나며 이후 서서히 온도가 상승하는 장기 거동을 보인다. 전산유체역학을 적용한 현재의 상세 해석결과는 이전의 집중(lumped) 모델을 사용한 보수적인 계산결과에 비해 낮은 격실온도 상승률을 예측한다.

설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009)

  • 한화택;이대영;김서영;최종민;백용규;권영철
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

국내 지면온도의 시공간적 변화 분석 (Analyzing Spatial and Temporal Variation of Ground Surface Temperature in Korea)

  • 구민호;송윤호;이준학
    • 자원환경지질
    • /
    • 제39권3호
    • /
    • pp.255-268
    • /
    • 2006
  • 58개 기상관측소에서 최근 22년간(1981-2002) 측정된 기상 자료를 이용하여 국내의 기온(SAT) 및 지면온도(GST)의 시공간적 변동 경향을 분석하였다. 먼저 관측 자료로부터 각 관측소의 평균기온(MSAT)과 평균지면온도(MGST)를 계산하였으며, 다중선형회귀분석을 통해 MSAT와 MGST를 예측할 수 있는 회귀식을 산정하였다. 회귀모형의 회귀변수는 관측소의 위도 및 고도이다. 회귀모형의 추정치와 실제 관측값의 결정계수($R^2$)는 각각 0,92와 0.94로 나타나 모형의 예측 정확성이 매우 높은 것으로 분석되었다. MGST는 지열펌프 시스템 설계의 주요 입력 변수이므로 최근 지열에너지자원 활용 분야에서 매우 중요하게 다루어지는 변수이다. 따라서 제시된 회귀모형은 신뢰할만한 관측 자료가 없는 지역에서 MGST를 추정하는데 매우 유용하게 이용될 수 있을 것으로 예상된다. SAT 자료에 대한 선헝회귀분석을 통해 지구온난화 및 도시화에 기인한 기온 상승의 장기 추세 변동성을 탐색하였다. 1개 관측소를 제외한 57개 관측소에서 $0.005{\sim}0.088^{\circ}C/yr$ 범위의 기온증가율을 가지는 추세 변동이 확인되었다. 또한 GST에 영향을 미치는 기상요소로서 일사량, 지구복사, 강수량 및 적설량 자료를 분석하였다. GST는 주로 SAT 및 일사량에 의하여 결정되지만 강수 및 증발에 의한 토양의 열용량 변화, 적설에 의한 대기와 지표면 차단, 지구복사에 영향을 줄 수 있는 대기의 조건 변화 등이 복합적인 변동 요인으로 작용하는 것으로 나타났다.

지열냉난방시스템 수직형 지중열교환기 그라우트의 열적 특성에 관한 연구 (A Study on Thermal Conductivity Properties of Ground Heat Exchangers for GSHP systems)

  • 백성권;전중규;안형준
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.546-549
    • /
    • 2007
  • 지열 냉난방 시스템의 설계는 냉난방 공간의 크기에 따라 필요한 부하를 계산하여 설계하게된 다. 설계 부하를 충분히 소화할 수 있는 지열교환기의 길이와 보어홀의 깊이 및 개수는 지반의 열적 특성에 크게 좌우된다. 열전도율이 큰 지반일수록 지열교환기 내의 열 흡수 및 소산이 효과적으로 이루어져 지열교환기의 길이도 상대적으로 짧아질 수 있다. 즉, 효율적이고 정확한 설계를 하기 위해서는 지반, 암반 및 지중열교환기의 물리적 특성에 따른 열적 특성을 설계자는 미리 숙지하여야 한다. 현재 국내에서 수직 밀폐형 지중열교환기의 그라우트로 벤토나이트를 가장 많이 사용하고 있으나, 해외의 경우 지중 조건에 따라 시멘트 또는 벤토나이트를 적절히 선택하여 시공하고 있다. 이는 벤토나이트의 특성상 적용 조건이 제약을 받기 때문이며, 특히 지하수가 존재하지 않을 경우 사용이 사실상 불가능하다. 국내에서 이에 대한 충분한 연구는 아직 이루어지지 않았으며, 시멘트 그라우트를 사용하기 위한 물리적, 열적 특성에 대한 연구가 필요한 시점이라 판단하여 본 연구를 수행하였다. 시멘트 그라우트의 경우 수화반응이 일어나는 초기의 건조수축을 최소화하는 배합비로 물성을 구성하였으며, 벤토나이트는 일반 현장 시공 비율을 사용하였다. 열전도율은 첫째 실내 시험으로 시멘트 그라우트에 대한 열판시험법과 벤토나이트 그라우트에 대한 탐침시험법으로 수행하여 구하였으며, 두 번째 방법인 현장 시공으로 직접 현장열응답시험을 수행하여 그라우트 간의 열적 특성을 비교하였다. 또한 기존 시멘트그라우트의 열적 특성을 개량한 코오롱건설에서 개발한 시멘트 그라우트에 대한 열적 거동도 기존 타 그라우트의 열적 거동과 비교하였으며, 개발 제품의 성능이 상당히 우수함을 알 수 있었다.

  • PDF

여러 가지 종류의 태양열 집열기 작동성능 비교 분석 연구 (The study on the comparison of the operation performance of different type of solar collectors)

  • 김휘동;백남춘;이진국;주문창
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.64.2-64.2
    • /
    • 2010
  • The objective of this study is to make a comparative study of the operation performance of different type of solar collectors. A flat-plate collector, a single-glazed evacuated collector and a double-glazed evacuated collector are used in this study. These 3 type of collectors are connected in series in the order of a flat-plate collector, a single-glazed evacuated collector and a double-glazed evacuated collector. This experimental facility is a kind of a solar system with a controller, a heat exchanger, a storage tank and a circulation pump. Each collector has a different collection area(flat-plate collector-$6.00m^2$ total area/$5.61m^2$ aperture area, double-glazed evacuated collector-$6.04m^2$ total area/$4.92m^2$ aperture area, single-glazed evacuated collector-$7.65m^2$ total area/$5.61m^2$ aperture area) and its performance characteristic respectively. The experiments have been demonstrated at around $70^{\circ}C$ operating temperature(flat-plate collector inlet temperature). The thermal collecting efficiencies of each collector are obtained under the different insolation and operation condition as a result.

  • PDF