• Title/Summary/Keyword: heat protection

Search Result 583, Processing Time 0.029 seconds

The Real Fire Test in Bedroom for the Performance Based Fire Design (성능기반 화재안전설계를 위한 침실 공간에서의 실화재 실험)

  • Kim, Hyung-Jun;Kwon, In-Kyu;Kweon, Oh-Sang;Kim, Heung-Youl;Chae, Seung-Un
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.32-37
    • /
    • 2013
  • For The performance based fire design of the buildings, the fire characteristic such as proceeding and scale of the fire should be figured out but, there is lack of relevant information because of different conditions and difficulties of mock-up test like type of division space, ventilation condition, etc, in buildings. Therefore, in the study, a heal release rate etc, the engineering characteristic data value on the fire is proposed by mock-up fire test for division space in buildings. The mock-up fire test is carried out in a bedroom with 2.4 (L) ${\times}$ 3.6 (W) ${\times}$ 2.4 (H) m model. Initial ignition was started from trash box and the test was carried out for 30 min. As a result of the fire test, flame was broken to outside within 7 min and 50 s after starting the test and the maximum heat release rate was measured as 3,810.6 kW at 9 min and 34 s.

Review of effect on Okchun-hwan for Diabetes Mellitus (당뇨병에 대한 옥천환(玉泉丸)의 효과에 관한 고찰)

  • Kim, Bum Joon;Bae, Go Eun;Choi, Jin Yong;Cho, Jae Hyun;Park, Hye Lim;Hong, Mi Na;Kwon, Jung Nam;Kim, So Yeon;Yun, Young Ju;Lee, In;Choi, Jun Yong;Han, Chang Woo;Hong, Jin Woo;Park, Seong Ha
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.31 no.1
    • /
    • pp.20-24
    • /
    • 2017
  • The aim of this study is to investigate the effect of Okchun-hwan on Diabetes Mellitus. We searched articles from Oasis and Chinese Academic Journals(CAJ) online databases. Searching keywords were '玉泉丸', '옥천환'. Among the articles published from January 2000 to September 2016, The 79 articles were found. After review the title, abstract and original, The five articles were selected finally to rule out a completely different prescriptions and an animal test articles. Okchun-hwan is effective in improving the symptoms(dry mouth and throat, fatigue, eat easy to hunger, shortness of breath, sweating, palpitation, cardiac heat, insomnia, and tongue)of a patient with deficiency of both qi and yin diagnosis(氣陰兩虛證) on Diabetes Mellitus, as well as act on protection of endothelial cells and regulation of insulin sensitivity, insulin resistance that cause the diabetic chronic vascular complications.

Fire Simulation for Vent Flow and Temperature in Engine Room of Small Ship: Effects of Ceiling Duct Location and Side Vent Size (소형선박 기관실의 개구부 유동 및 온도에 대한 화재시뮬레이션: 천장 통풍통 위치 및 측면 개구부 크기 영향)

  • Jeong, Lee-Gyu;Lee, Chi Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.5
    • /
    • pp.454-465
    • /
    • 2020
  • Fire simulations were performed using the Fire Dynamics Simulator (FDS) software to examine the vent flow and temperature in the engine room of a small ship. A diesel fire with a heat release rate of 10 kW was targeted, and the effects of the ceiling duct location, side vent existence and nonexistence, and side vent size were investigated. The existence or nonexistence of the side vent and its size considerably affected the smoke behavior, mass flow rate through the vent, and temperature. When the side vent was not installed or was small, the smoke layer reached the floor in the engine room. In addition, as the side vent size increased, the mass flow rate through the vent increased with decreasing temperature value. However, the effects of the ceiling duct location on the smoke behavior, mass flow rate through the vent, and temperature seemed to be relatively minor compared to those of the side vent size. Therefore, to improve the fire safety of the engine room in a small ship, the side vent size is considered to be a more important design factor than the ceiling duct location.

A Study on the Fire Prevention Activities and Suppression Measures of Utility-Pipe Conduit (지하공동구 화재예방활동 및 진압대책에 관한 연구)

  • Lee, Jung-Il
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.4
    • /
    • pp.63-68
    • /
    • 2010
  • Utility-Pipe Conduit is, Housing and city effectively accommodate what they absolutely need power, communications, gas, pipeline, water supply, drainage, energy facilities etc, according to expansion of urban infrastructure are derived, several ways to solve problems in, collection facilities in place are maintained and managed facility. If Utility-Pipe Conduit is damaged, as well as national security, because their impact on society as a whole, by introducing large vulnerability in the fire prevention activities and suppression measures and disaster for our situation by introducing measures, comprehensive analysis of the fire risk, it shall establish fire prevention activities and suppression through analysis of Utility-Pipe Conduit design, institutional issues, the problem of fire protection facilities, fire spread phenomenon etc. Because of Utility-Pipe Conduit is an enclosed place, so incomplete combustion due to lack of oxygen supply that there are problem such dark smoke, carbon monoxide etc, toxic combustion products and heat generation and visual impairment is an issue difficult to enter. As well as fire prevention activities, the fire In light of the particularity of the under ground than above ground fire, so this phenomenon is weak fire fighting that fire to become effective fire fighting tactics, basically it is necessary difficulty softening, non-burn softening and prevent combustion expansion of the cable is installed on the Utility-Pipe Conduit, having to considering the specificity of the response command system and relevant organizations to establish an on-site, Structural identification and other information gathering required to record of Response agencies, keep air conditioning system 24 hours and strengthening Virtual Total Training of Response agen

Comparison of Gene Expression in Larval Fat Body of Helicoverpa assulta in Different Temperature Conditions (온도변화에 따른 담배나방 유충 지방체의 유전자 발현 비교 분석)

  • Cha, Wook Hyun;Kim, Kwang Ho;Lee, Dae-Weon
    • Korean journal of applied entomology
    • /
    • v.57 no.3
    • /
    • pp.165-175
    • /
    • 2018
  • Insects are known to live at wide range of temperature, but can not survive when they are exposed to over $40^{\circ}C$ or below supercooling point. The larvae of Helicoverpa assulta have been reared at high ($35^{\circ}C$), low (3 to $10^{\circ}C$), and room temperature ($25^{\circ}C$; control). To identify stress-related genes, the transcriptomes of fat body have been analyzed. Genes such as cuticular proteins, fatty acyl ${\Delta}9$ desaturase and glycerol 3 phosphate dehydrogenase were up-regulated whereas chitin synthase, catalase, and UDP-glycosyltransferase were down-regulated at low temperature. Superoxide dismutase, metallothionein 2, phosphoenolpyruvate carboxykinase and trehalose transporter have been up-regulated at high temperature. In addition, expressions of heat shock protein and glutathione peroxidase were increased at high temperature, but decreased at low temperature. These temperature-specific expressed genes can be available as markers for climate change of insect pests.

The Memory of War : from War Damages to Natural Disaster -The Evacuation Image Portrayed in Korean War Painting (전쟁의 기억: 전재에서 자연재해로 - 6.25전쟁기 회화 작품에 나타난 피난 이미지)

  • Cho, Eun-jung
    • The Journal of Art Theory & Practice
    • /
    • no.13
    • /
    • pp.7-33
    • /
    • 2012
  • The memory of the Korean War is about the time period when people lived toughly during evacuation, due to being exposed to the natural climate such as intense cold or heat without any protection, leaving their comfortable home and living in temporary built shelters which were barely enough to avoid the wind. 'Death is concealed and only the figures of evacuation for survival were expressed, just as how the government ordered. Since the experience of the battlefield is personal and fragmentary, that is broken into pieces, it does not have compatibility. As war is a distorted experience that cannot be placed in a big picture, it is not possible to take a view of the war's big picture. Having this individualized experience as a common collective memory is an issue and it is the will that people tries to pursue. The reason why the evacuees from north to south, and as well as from the south to further south were all able to be adopted as the theme of artworks due to the military action that emptied the occupied territories of the North Korean Army under the forced removal command. In such situations, the natural state of the 'snow' was like a symbol of the 1.4 Recession. The group of people who were thrown into the intense cold displaced the war damage of loosing their base livelihood, and symbolized the obedient citizens who faithfully follow their government's command. The figure of advocating anti-communism is projected as a figure of a refugee during cold winter-time and it contains ones past which he or she obeyed its own country's commands. Evacuation, especially the evacuation during the winter is a visual device that can confirm these kinds of country's command. The consequences were same for the artists as well. Therefore, the situation being communal could be found due to the individual experiences during war are ideological. The image of the refuge shown in the picture played the role of strengthening the consciousness of defecting to South Korea into the meaning of the 'Finding Freedom.' I would like to express that the reason of them leave their home during the harsh winter is in order to avoid the oppression of the Communist Party. The evacuation that people went through was not to 'Finding Freedom', but 'To Survive'. Later, this evacuation has been imprinted as a behavior of choosing free Republic of Korea, which was an ideological issue. Anti-communism was the rule of survival in South Korea society, and people have the tendency to remember what they want to remember. As it is not the people who possesses an incident, but the memory that possesses ones, people cover their memory with disguised plots in order to forget the violence and to live a different prologue. They share the incident of violence as a hurtful memory. The tragedy of the Korean War was the result of Ideology and being in between the powerful nations' rights, but the violence during the war has been depicted as a natural disaster, which was the evacuation in heavy snow.

  • PDF

Assessment of Immune Quality and Pathogen Contamination of Colostrums Collected from Colostrum Banks in Korea (초유은행에서 수거한 초유의 병원체 오염과 면역수준의 평가)

  • Kim, Won-Il;Park, Sang-Yul;Kim, Sang-Jin;Cho, Yong-Il;Hur, Tai-Young;Kim, Nam-Soo
    • Journal of Veterinary Clinics
    • /
    • v.30 no.4
    • /
    • pp.223-229
    • /
    • 2013
  • Because colostrum is considered to be the sole source of passively acquired maternal antibodies for calves, newborn calves must consume colostrum to gain disease resistance during their early years of life. Storage of surplus colostrum from dairy cows right after calving and feeding newborn calves in deficiency of colostrum to assure adequate uptake of IgG for protection of the calf has been a common practice in the bovine production. In the current study, 35 colostrums were randomly collected from 3 colostrum banks located in different regions of Korea and monitored for general bacterial contamination and major bovine pathogens. Immunoglobulin concentrations and BVDV-specific antibodies were also determined to evaluate the immune quality of the colostrums. Moderate to severe bacterial contamination (up to 72,000,000 CFU/ml) was observed in most of the colostrums collected from colostrum banks. General immune quality of the colostrums was under the satisfactory level since most of the colostrums contained less than 50 g/L of IgG, which is the minimum concentration for good quality colostrums. Therefore, colostrum for colostrum bank should be collected at the first 2-3 post-partum milkings according to proper harvesting and handling procedures to guarantee the safety and quality of colostrum. In addition, it was recommended that colostrum should be heat-treated before frozen and stored in the bank because pasteurization at $63^{\circ}C$ for 30 min was very effective reducing the risk of disease transmission without causing significant degradation of immunoglobulins.

Improving the Corrosion Resistance of Cold-Rolled Carbon Steel by Treatment with a Hybrid Organic/Inorganic Coating Solution (유/무기 하이브리드 코팅액에 의한 냉간압연강판의 내식특성)

  • Kim, Jung-Ryang;Choi, Chang-Min;Nam, Ki-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.4
    • /
    • pp.405-412
    • /
    • 2012
  • In the past, a very popular way to reduce the corrosion rate of zinc was the use of chemical conversion layers based on $Cr^{+6}$. However, the use of chromium salts is now restricted because of environmental protection legislation. Previous research investigated the optimum corrosion resistance of galvanized steel treated with an organic/inorganic solution containing Si. The result showed that the optimum corrosion resistance occurred by heat treatment of $190^{\circ}C$ in 5 min. In this study, one organic and three hybrid organic/inorganic coating solutions were applied to cold-rolled (CR) carbon steel. The coatings were then evaluated for corrosion resistance under a salt spray test. The coating solutions examined in this study consisted of urethane-only, urethane-Si, urethane-Si-Ti, and urethane-Si-Ti-epoxy. The results of the 7 h salt spray test showed that the urethane-Si-Ti and urethane-Si-Ti-epoxy coating solutions had superior corrosion resistance on CR steel.

Assessment of the Combustion Diffusion Pattern and Fire Risk of a Water Purifier Damaged by a General Fire (일반화염에 의해 소손된 정수기의 연소 확산 패턴 및 화재위험성 평가)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.35-39
    • /
    • 2012
  • This paper analyzes the combustion diffusion pattern when a water purifier is artificially ignited outside and inside in order to provide data to examine the cause of fire of a water purifier damaged by fire. The analysis result of the combustion diffusion pattern of a water purifier shows that the combustion diffused at a higher speed when it was ignited inside the purifier than when ignited outside. It took approximately 360 seconds for the water purifier to be half-burned when ignited on the outside, and approximately 180 seconds when ignited from inside. That is, it is thought that the internal combustion speed is higher because the internal ignition causes the generated heat to be accumulated and radiated instantly. It was observed that the water purifier damaged by fire caused by external ignition showed a uniform carbonization pattern and the carbide burned down at the bottom were gradually deposited. The water purifier damaged by internal ignition showed a relatively clear boundary of carbonized surface, which formed a V-pattern. The difference in the combustion patterns presents an objective base from which to determine where the fire started. By the time the purifier was half-burned by fire, the built-in fuse had not melted and the power supply protection device did not operate. In addition, as was found in the case of the fuse damaged by a general fire, carbonization occurred at the metal holder, and it is thought that this fact may be used as a basis from which to determine the cause of a fire.

Effects of NaCl/H3PO4 Flame Retardant Treatment on Lyocell Fiber for Thermal Stability and Anti-oxidation Properties (NaCl/H3PO4 내염화 처리가 라이오셀 섬유의 열 안정 및 내산화 특성에 미치는 영향)

  • Kim, Eun Ae;Bai, Byong Chol;Jeon, Young-Pyo;Lee, Chul Wee;Lee, Young-Seak;In, Se Jin;Im, Ji Sun
    • Applied Chemistry for Engineering
    • /
    • v.25 no.4
    • /
    • pp.418-424
    • /
    • 2014
  • The improved thermal stability and anti-oxidation properties of Lyocell fiber were studied based on flame retardant treatment by using NaCl/$H_3PO_4$ solution. The optimized conditions of flame retardant treatment were studied on various maxing ratio of NaCl and $H_3PO_4$ and the mechanism was proposed through experimental results of thermal stability anti-oxidation. The IPDT (integral procedural decomposition temperature), LOI (limited oxygen index) and $E_a$ (activation energy) increased 23, 30 and 24% respectively via flame retardant treatment. It is noted that thermal stability and anti-oxidation improved based on char and carbon layer formation by dehydrogenation and dissociation of C-C bond resulting the hindrance of oxygen and heat energy into polymer resin. The optimized conditions for efficient flame retardant property of Lyocell fiber were provided using NaCl/$H_3PO_4$ solution and the mechanism was also studied based on experimental results such as IDT (initial decomposition temperature), IPDT, LOI and $E_a$.