• 제목/요약/키워드: heat of hydration heat

검색결과 712건 처리시간 0.023초

고형 폐기물 소각재를 이용한 alinite 시멘트의 합성 (Synthesis of Alinite Cement Using Combustion Ash of Solid Wastes)

  • 강현주;홍성수;임계규;오희갑;김정석;민경소
    • 한국세라믹학회지
    • /
    • 제37권8호
    • /
    • pp.768-773
    • /
    • 2000
  • Alnite clinker, which is based on CaO-SiO2-CaCl2 system, was synthesized by recycling Cl-containing waste, and its hydraulic properties were onvestigated. Alinite coinkers with two different chemical compositions were burned for 10∼30 minutes in the range of temperature, 1350∼1450$^{\circ}C$. The microstructures of those clinkers were characterized by powder X-ray diiffracuion analysis, optical microscope, and scanning electronic microscope and heat of hydration of alinite cements which was measured in order to investigate hydraulic properties. X-ray analysis shwoed that f-CaO in both clinkers with different compositions significantly was decreased with transforming C2S(belite) to C3S(alite). From the results of microscopy and scanning electron microscopy(SEM), crystal of synthesized alite(C3S) was larger and better crystallinity than that of ordinary portland cement.

  • PDF

고로슬래그 시멘트의 초기강도 발현에 있어서 수산화칼슘의 영향 (An Effect of $Ca(OH)_2$ on Development of an Early Age Strength of GGBFS Cement)

  • 이제방;김재신;소승영;소양섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.64-69
    • /
    • 1999
  • Slags are by-products of the metallurgical industry. The most important slag from the standpoint of the quantity used as building material is iron blastfurnace slag. Slags are either crystalline stable solid used as aggregates or glassy material used as hydraulic binder. Slag cements are low heat of hydration cements. Slags react more slowly with than portland cement but they can be activated chemically. Activatiors can be either alkaline activators such as soda, lime, sodium carbonate, sodium silicate or sulphate activators such as calcium sulphate or phosphogypsum. So, in this study slaked lime was used as an activator that the compressive strength of this modified cement(M1 type) is high range in early age. And initial setting time of M1 type cement was shorter than conventional cements.

  • PDF

개선된 미소면 모델을 적용한 매스콘크리트 기초슬래브의 초기균열거동 해석 (Early Age Cracking Analysis of Massive Concrete Base Slab with Enhanced Microplane Model)

  • 이윤;김진근;우상균;송영철;이성태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.458-461
    • /
    • 2006
  • Early age cracking of concrete is a widespread and complicated problem, and diverse applications in practical engineering have focused on this issue. Since massive concrete base slab composes the infrastructure of other concrete structures such as pier, concrete dam, and high rise buildings, early age cracking of that is considered as a crucial problem. In this study, finite element analysis (FEA) implemented with the age-dependent microplane model was performed. For a massive concrete base slab, cracking initiation and propagation, and deformation variation were investigated with concrete age. In massive concrete slab, autogenous shrinkage increases the risk of early age cracking and it reduces reinforcement effect on control of early age cracking. Gradual crack occurrence is experienced from exterior surface towards interior of the slab in case of combined hydration heat and autogenous shrinkage. FEA implemented with enhanced microplane model successfully simulates the typical cracking patterns due to edge restraint in concrete base slab.

  • PDF

고온이력이 콘크리트의 강도발현에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effects of High temperature Hysteresis on Concrete Strength Development)

  • 김학영;민홍준;장형준;공민호;안무영;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.433-436
    • /
    • 2006
  • This study is basic experiment for estimating influence of strength by curing temperature of concrete's heat of hydration and estimate relationship of compressive strength development by initial curing temperature factor, and then asume temperature factor which influence compressive strength development and for showing basic document of quality control. According to the result of managerial test pieces by the curing temperature factor high-curing temperature shows high strength on 3 day compare with low curing-temperature, shows higher strength than the piece of high curing temperature.

  • PDF

CFRD 차수벽콘크리트에서의 섬유보강효과에 관한 실험적 연구 (An Experimental Study on the Effect if Fiber Reinforced on CFRD Face Slab Concrere)

  • 최세진;임정열;김완영;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.122-125
    • /
    • 2000
  • CFRD (Concrete Faced Rockfill Dam) face slab concrete has a much capability to occur crack due to drying shrinkage, hydration heat and bas compaction etc. Because of crack of concrete induce structural problem and decrease durability of concrete, it is need to reduce crack of concrete. This is an experimental study to analyze the effect of fiber reinforced on CFRD face slab concrete. for this purpose, it was investigated and analyzed the engineering properties of plain concrete and polypropylene fiber reinforced concrete (PFRC) according to test result ; the test include slump, air content, compressive strength, tensile strength, drying shrinkage and permeability etc. As the results, it was found permeability and drying shrinkage of PFRC less than that of plain concrete.

  • PDF

초고강도 ($\acute{f}_{C91}$= 950kg/$\textrm{cm}^2$) P.C Bearing Plate 개발에 관한 연구 (A Study on the Development of a Ultra-Strength Precast Concrete Bearing Concrete Bearing Plate)

  • 소현창;정병욱;김재우;문성규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.643-648
    • /
    • 1997
  • P.C Bearing Plate method, corresponding to the existing steel plate build-up method, is developed by the very first in domestic and is applied to the foundation in the HYUNDAI building at Kang-Nam. P. C Bearing Plate produced in ourself P.C plant can stand against vertical load of 7,000ton obtaining allowable force of soil. It is possible to minmize cost expediting, do site assembling and omit unnecessary excavation work by plant prefabrication of foundation member. The purpose of this paper is to study the optimum mixing design of Ultra-high strength concrete ($\acute{f}_{C91}$= 950kg/$\textrm{cm}^2$), crack control through measuring the heat of hydration, mock up test for the optimum curing method. As mentioned above, developing the Ultra-high strength Precast Concrete Bearing Plate set up successfully in the site foundation work of the HYUNDAI Building at Kang-Nam.

  • PDF

초기 고온이력을 받은 시멘트 모르타르의 강도 특성에 관한 실험적 연구 (An Experimental Study on the Characteristics of Strength in Mortar under High Temperature conditions in an Early Age)

  • 김영주;김한식;공민호;김제섭;이영도;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.517-520
    • /
    • 2005
  • This study is basic experiment for estimating influence of strength by curing temperature of concrete's heat of hydration and estimate relationship of compressive strength development by initial curing temperature factor, and then asume temperature factor which influence compressive strength development and for showing basic document of quality control. According to the result of cement mortar by the curing temperature factor high-curing temperature shows high strength on 3 day compare with low curing-temperature, shows higher strength than the piece of high curing temperature.

  • PDF

모르터 압축강도 특성에 영향을 미치는 고온이력에 관한 실험적 연구 (An Experimental Study on the Characteristics of Strength in Mortar under High Temperature conditions in an Early Age)

  • 김영주;공민호;송인명;양동일;백민수;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.703-706
    • /
    • 2004
  • This study is basic experiment for estimating influence of strength by curing temperature of concrete's heat of hydration and estimate relationship of compressive strength development by initial curing temperature factor, and then asume temperature factor which influence compressive strength development and for showing basic document of quality control. According to the result of cement mortar by the curing temperature factor high-curing temperature shows high strength on 3 day compare with low curing-temperature, shows higher strength than the piece of high curing temperature.

  • PDF

고황산염 시멘트를 활용한 저탄소 친환경 콘크리트 개발 (Development of low-carbon eco-friendly concrete using super-sulfated cement)

  • 기전도;이상현;김영선;전현수;석원균;양완희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.199-200
    • /
    • 2023
  • Eco-friendly concrete contains only 5% of cement yet achieves equal or greater strength compared to conventional concrete, reducing salt-attack impact and hydration heat by more than 30% and ensuring higher construction quality for underground structures. Furthermore, eco-friendly concrete can reduce up to 90% of carbon dioxide emissions compared to traditional concrete, enabling a reduction of approximately 6,000 tons of carbon emissions for 1,000 of apartment units construction. This is equivalent to planting around 42,000 trees

  • PDF

고품질 매스콘크리트 시공을 위한 배합설계 및 온도균열제어 시스템에 관한 연구 (A Study on the Mix Design and the Control System of Thermal Crack for High Quality Mass Concrete)

  • 김선구;이상수;원철;박상준;김동석
    • 한국건축시공학회지
    • /
    • 제1권2호
    • /
    • pp.174-178
    • /
    • 2001
  • This study was performed to control the thermal crack of the mat footing slab in the multi-purposed buildings. In this study, we executed the mixing design of concrete to satisfy the workability and the quality according to the site conditions. And, we evaluated quantitatively about the possibility of thermal crack by using hydration heat analysis system. Finally, we proposed the optimal mixing conditions, curing methods and curing period which all factors are considered. As a result, the optimal mixing conditions were : W/B 41%, unit binder 375kgf/$\textrm{m}^3$, FA replacement ratio 20%. Lowest thermal stress was 22.0kgf/$\textrm{cm}^2$ and at that time thermal crack index was over 1.5, when the coefficient of thermal conductivity was lowest among the curing conditions. And, the total curing time was estimated at 6.7 days according to curing steps.

  • PDF