• Title/Summary/Keyword: heat and mass balance

Search Result 122, Processing Time 0.021 seconds

A Study on Design Characteristics of Yeosu Circulating Fluidized Bed Boiler (여수화력 순환유동상 보일러의 설계특성 고찰)

  • Kim, Jae-Sung;Lee, Jong-Min;Kim, Dong-Won;Kim, Tae-Hyun;Choi, Sang-Min
    • Journal of the Korean Society of Combustion
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • 340 MWe circulating fluidized bed (CFB) boiler in Yeosu power station is under construction. The circulating fluidized bed boiler in the Yeosu power plant has a number of differences from other domestic boilers in terms of scale and design. Evaluation of design parameters of the Yeosu CFB boiler should be required because the direct application of existing technology is limited. In this study, design characteristics of the Yeosu CFB boiler was summarized. And thermogravimetric analysis was conducted with comparing other rank coals. Watersteam side heat absorption, flue gas temperature and heat transfer coefficient were calculated by heat and mass balance. Design parameters for the Yeosu CFB boiler were discussed along with typical value in the CFB design range.

UNTEADY HEAT FLOW AND TEMPERATURE VARIATION IN HUMAN SST REGIONS

  • Sanyal, D.C.;Maji, N.K.
    • Journal of applied mathematics & informatics
    • /
    • v.9 no.2
    • /
    • pp.731-744
    • /
    • 2002
  • The temperature distribution in human skin and subdermal tissue layer is presented using bioheat transfer equation. The body temperature is determined by the balance between heat produced and heat lost by our body. The time-dependent solutions have been found to be affected by the metabolic heat generation rate, blood mass flow, the rate of evaporation of perspiration and also by the atmospheric temperature. The analytic solutions for different layers have been calculated numerically and are also shown graphically.

Thermodynamic Energy Balance Analysis of Underground Lined Rock Caverns (LRC) for Compressed Air Energy Storage (CAES) (복공식 지하 압축공기에너지 저장공동의 열역학적 에너지수지 분석)

  • Kim, Hyung-Mok;Park, Do-Hyun;Ryu, Dong-Woo;Choi, Byung-Hee;Song, Won-Kyong
    • Tunnel and Underground Space
    • /
    • v.21 no.4
    • /
    • pp.297-306
    • /
    • 2011
  • In this paper, we performed thermodynamic energy balance analysis of the underground lined rock cavern for compressed air energy storage (CAES) using the results of multi-phase heat flow analysis to simulate complex groundwater-compressed air flow around the cavern as well as heat transfer to concrete linings and surrounding rock mass. Our energy balance analysis demonstrated that the energy loss for a daily compression and decompression cycle predominantly depends on the energy loss by heat conduction to the concrete linings and surrounding rock mass for a sufficiently air-tight system with low permeability of the concrete linings. Overall energy efficiency of the underground lined rock caverns for CAES was sensitive to air injection temperature, and the energy loss by heat conduction can be minimized by keeping the air injection temperature closer to the ambient temperature of the surroundings. In such a case, almost all the heat loss during compression phase was gained back in a subsequent decompression phase. Meanwhile, the influence of heat conductivity of the concrete linings to energy efficiency was negligible.

Efficient Energy Management for Pyro-processing of Solids - (1) Heat & Mass Balance and Evaluation (고체 고온공정에서 효율적 에너지 관리 - (1) 공정 열정산 및 평가 방법)

  • Ha, Daeseung;Choi, Sangmin
    • Journal of the Korean Society of Combustion
    • /
    • v.21 no.1
    • /
    • pp.18-30
    • /
    • 2016
  • Pyro-process of solids is the way to heat solid materials under high temperature. In this processing, energy efficient use is one of the main concerns due to its high energy consumption of bulk materials. To calculate the energy use of processes, heat & mass balance in simplified 0-dimensional model was performed. Energy calculation by this simplified model can lead to confusion due to simplification. Thus, it is necessary to understand considerations of energy analysis. In this study, cement manufacturing as a very common example of pyro-processing of solids, was introduced for explaining considerations of energy analysis for energy efficient use.

A Study on the Heat and Mass Balance of Smelting Reduction Process for Manganese Nodules (망간단괴 용융환원 제련공정의 물질 및 열수지 모델링)

  • Cho, Moon Kyung;Park, Kyung Ho;Min, Dong Joon
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.5
    • /
    • pp.304-310
    • /
    • 2009
  • Recently, manganese nodule has been focused on alternative resources because of its high grade of noble metallic elements such as Co, Ni, and Cu etc. From the viewpoint of an optimization the operating variables for energy efficiency of smelting reduction process, thermodynamic model for smelting reduction process of Manganese nodule was developed by using energy and material balance concept. This model provided that specific consumption of pure oxygen and coke was strongly depended on post combustion ratio (PCR) and heat transfer efficiency (HTE). The dressing and dehydrating process of low grade manganese can be proposed an essential process to minimize the specific energy consumption with decreasing slag volume. The effect of electricity coal base smelting reduction process was also discussed from the energy optimizing point of view.

Effects of 3 mg·kg-1 Caffeine Ingestion during Exercise on Fluid-Electrolyte Balance and Tympanic temperature changes in the Heat (고온 환경에서 3 mg·kg-1의 카페인 섭취가 운동 시 체액, 전해질 균형 및 외이온의 변화에 미치는 영향)

  • Kim, Tae-Wook;Park, Bong-Sup
    • Korean Journal of Exercise Nutrition
    • /
    • v.13 no.1
    • /
    • pp.75-81
    • /
    • 2009
  • This study aims to find out the effect of ingestion of 3 mg·kg-1 caffeine on fluid-electrolyte balance and Tty change during exercise under heat environment of 30~32℃ (40-50% humidity). Five trained males who routinely trained for approximately 60 min·d-1, 3-6 d·wk-1 (age; 28.20±3.56yrs, height; 174.56±5.46 cm, body mass; 76.13±9.02 kg, body fat(%); 14.24±3.99, VO2max; 54.00±4.30 mL·kg-1·min-1, exercise career; 4.20±1.95yrs) performed 40min of treadmill running in heat chamber. The study was a double-blind, randomized, crossover design. Body mass change following exercise was higher for the PLAC (Placebo) and CAFF (Caffeine) in comparison to the CON (Control), there was no significant difference between the CAFF, PLAC, CON (p= .997). The Usg not significant differences (p= .731) and Osmurine not significant differences between the CAFF, PLAC, CON (p= .901). There also were not significant between the CAFF, PLAC, CON for [Na+]urine and [K+]urine (p= .928, p= .469). In the case of Tty, although the increase rate of Tty was the highest for the CAFF on exercise early, exercise the second half in comparison to the CON and PLAC, there was not significant interaction effect between the CAFF, PLAC, and CON of Tty (p= .067), In conclusion, it was confirmed that the 3 mg·kg-1 caffeine ingestion prior to exercising in heat environment does not impart negative effect on body fluid, electrolyte balance and changes in Tty.

Study on the Multi-Zone Furnace Analysis Method for Power Plant Boiler (발전용 보일러에 대한 다중영역분할 화로해석 기법의 활용성 연구)

  • Baek, SeHyun;kim, Donggyu;Lee, Jang Ho
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.427-432
    • /
    • 2020
  • In this study, a multi-zone furnace analysis method that couples a 1D energy and mass balance calculation with a 3D radiative heat transfer calculation is tested in order to verify its reliability. The calculated results for a domestic 500 MW capacity coal-fired boiler furnace were compared with the design data of the boiler manufacturer and CFD analysis, and a good agreement was achieved. Although this calculation method is less sophisticated than the CFD furnace analysis, it has an advantage in terms of calculation time while being able to provide the furnace behavior according to the fuel characteristics and operational variable changes. Therefore, it is expected to be useful for boiler operation diagnosis and daily fuel/operation planning.

Study on the Anthropometric and Body Composition Indices for Prediction of Cold and Heat Pattern

  • Mun, Sujeong;Park, Kihyun;Lee, Siwoo
    • The Journal of Korean Medicine
    • /
    • v.42 no.4
    • /
    • pp.185-196
    • /
    • 2021
  • Objectives: Many symptoms of cold and heat patterns are related to the thermoregulation of the body. Thus, we aimed to study the association of cold and heat patterns with anthropometry/body composition. Methods: The cold and heat patterns of 2000 individuals aged 30-55 years were evaluated using a self-administered questionnaire. Results: Among the anthropometric and body composition variables, body mass index (-0.37, 0.39) and fat mass index (-0.35, 0.38) had the highest correlation coefficients with the cold and heat pattern scores after adjustment for age and sex in the cold-heat group, while the correlation coefficients were relatively lower in the non-cold-heat group. In the cold-heat group, the most parsimonious model for the cold pattern with the variables selected by the best subset method and Lasso included sex, body mass index, waist-hip ratio, and extracellular water/total body water (adjusted R2 = 0.324), and the model for heat pattern additionally included age (adjusted R2 = 0.292). Conclusions: The variables related to obesity and water balance were the most useful for predicting cold and heat patterns. Further studies are required to improve the performance of prediction models.

Energy and Mass Balance of Snowpack - Rapid snowmelt during Fohn events in the Takada plain -

  • ;Shinichi Takami
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.32 no.E
    • /
    • pp.88-94
    • /
    • 1990
  • Several models physically based to predict the evolution of the snowpack have been proposed. Validity of these models for hourly estimation is, however, questionable, since they have been tested only on a daily basis. A computational model to predict the amount of snowpack on an hourly basis in terms of snowload from a set of meterological measurements was developed and investigated the rapid snowmelt conditions during Fohn events in the Takada plain.

  • PDF

A Study on the Characteristics of Evaporative Heat Transfer for Carbon Dioxide in a Horizontal Tube (수평원관 내 이산화탄소의 증발열전달 특성 연구)

  • Cho, E.S.;Yoon, S.H.;Kim, M.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.104-107
    • /
    • 2000
  • Evaporative heat transfer characteristics of carbon dioxide has been investigated. Experiment has been carried out for seamless stainless steel tube with outer diameter of 9.55 mm and inner diameter of 7.75 mm. Direct heating method is used for supplying heat to the refrigerant was uniformly heated by electric current which was applied to the tube wall. The saturation temperature of refrigerant is calculated from the measured saturation pressure by using an equation of state. Inner wall temperature was calculated from measured outer wall temperature, accounting for heat generation in the tube and heat conduction through the tube wall. Mass Quality of refrigerant was calculated by considering energy balance in the preheater and the test section. Heat fluxes were set at 12, 16, 20, 23, and $27kW/m^2$, mass fluxes were controlled at 212, 318, 424, and $530 kg/m^2s$, and saturation temperature of refrigerant were adjusted at 0, 3.4, 6.7 and $10.5^{\circ}C$. From this study, heat transfer coefficients of carbon dioxide have been provided with respect to quality for several mass fluxes, heat fluxes. Finally, the experimental results in this study are compared with the correaltion by Gungor and Winterton(1987).

  • PDF