• Title/Summary/Keyword: head size

Search Result 1,245, Processing Time 0.026 seconds

Tumor Interstitial Fluid Pressure in Patients with Head and Neck Cancer (두경부 악성 종양 조직내 간질액 압력)

  • Cho Moon-June;Kim Jae-Sung;Lee In-Tae;Kim Jun-Sang;Jang Ji-Young;Kim Ki-Hwan
    • Korean Journal of Head & Neck Oncology
    • /
    • v.16 no.1
    • /
    • pp.9-13
    • /
    • 2000
  • Objectives: To determine the tumor interstitial fluid pressure(TIFP) in patients with head and neck cancerand predict radiotherapy outcome.Materials and Methods: In 12 biopsy proven primary head and neck cancer patients with accessible by direct inspection and palpation, and of sufficient thickness(>1cm) to permit accurate needle placement, we measured TIFP at cervical lymph node before and during radiotherapy using a modified wick-in-needle technique. Tumor size was measured clinically and radiologically. Results: The mean preradiotherapy TIFP was 23.4mmHg. Preradiotherapy TIFP had significant relationship with tumor size(p=0.0009). Preradiotherapy TIFP was not different between complete response group and partial or less response group(p=0.114). Radiotherapy outcome was not different between group with above and group with below average TIFP(p=0.09). Conclusion: The mean TIFP was elevated with 23.4mmHg before radiation therapy. Preradiotherapy TIFP had significant relationship with tumor size. It is not definitive that TIFP could be prognostic indicator of radiation response.

  • PDF

Study on the Sizing System of Head Gears (모자업체의 유형별 치수체계에 관한 연구)

  • Lee, Jin-Hee;Do, Wol-Hee
    • Korean Journal of Human Ecology
    • /
    • v.12 no.4
    • /
    • pp.571-578
    • /
    • 2003
  • The purpose of this research was to provide basic information for enhancing sizing suitability in terms of the need for appropriate fit in head gear. The method for this research was to survey about sizing system of head gear, basic measure part, repair service. The subject of this study were 15 head gear companies. The results of this research were as follows : 1. In the sex target analysis according to company type, most of fashion brand companies were producing woman's head gear. In case of the company to produce man's head gear, sizes appeared variously. On the other hand, the sports brand companies were producing unisex head gear and safety helmet companies were producing man's one. 2. The number of size of head gear manufacturing companies were under 3 sizing system. This means that the sizing system of current head gear manufacturing company isn't various. 3. While the measuring part using currently in the company was head girth, one to be considered necessary for manufacturing of head gear except the head girth was head height.

  • PDF

Clinical Manifestations of Papillary Thyroid Carcinoma Recurred as Distant Metastases (원격 전이로 재발한 갑상선 유두암에 대한 임상적 고찰)

  • Kim, Nam Young;Kim, Kyoung Hun;Park, Sung Ho;Lee, Guk Haeng;Lee, Byeong Cheol;Lee, Myung-Chul;Choi, Ik Joon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.31 no.2
    • /
    • pp.11-15
    • /
    • 2015
  • Background and Objectives: This study aimed to analyze the features of patients with papillary thyroid carcinoma (PTC) recurred as distant metastases (DM). Materials and Method: We retrospectively reviewed and analyzed clinical records of 63 patients who were treated for PTC recurred as DM between 2000 and 2006. Univariate and multivariate analyses of various clinical factors were performed. Results: Male patients were 12, and female patients were 51. The 5- and 10-year survival rates for PTC recurred as DM were 85% and 73%, respectively. Size of tumor, multiplicity of tumor, lateral neck node metastasis, and RAI ablation therapy with other treatments such as surgery were associated with survival rate (p < 0.005) in univariate analysis. The lateral neck node metastasis[p =0.039, hazard ratio=2.2(95% CI. 1.18~3.24)] and multiple organ DM[p =0.041, hazard ratio=2.18(95% CI. 1.03~2.89)] were related to the survival in multivariate analysis. Conclusion: PTC recurred as DM is uncommon (2.2%). The size of tumor, the multiplicity of tumor, lateral neck node metastasis and RAI ablation therapy with other treatments for DM were revealed as associated factors for the survival. Evaluation of DM should be considered in patients with PTC during long-term follow-up.

  • PDF

Study of the standardization of toothbrush and analysis of some university students using a toothbrush (일부 대학생의 사용잇솔 분석과 잇솔규격에 관한 연구)

  • Kim, Seol-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.5109-5115
    • /
    • 2014
  • The aim of this study was to develop a standard toothbrush to determine the changes the dental arch form. Toothbrushes were collected from university students Items, such as the toothbrush head size, shape of head, numbers of tuft, neck size, neck angle, and handle size, were measured. the full mouth study models from the participants were In conclusion, the size of the head of the toothbrush for adults needs to be less than the 25mm and less than 11mm in the longitudinal and transverse directions, respectively. The choice of toothbrush is important for controlling oral hygiene and professional education on the selection of the appropriate toothbrush is needed.

A 3-dimensional Printed Molding Technique for the Management of Humeral Head Osteomyelitis

  • Moon, Young Lae;dev Bhardwaj, Harvinder;Kim, Boseon;Ryu, Kang Hyeon
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.1
    • /
    • pp.46-48
    • /
    • 2017
  • There are many methods of making cement spacer in patients who require a two-staged operation for humeral head osteomyelitis. However, limitation of motion after the first surgery-due to inadequate size and insufficient intra-articular space for second surgery-remain to be an issue. To mitigate this issue, we made a cement spacer with the same size and shape of the patient humeral head. Four patients with humeral head osteomyelitis were enrolled in this study. To make the cement spacer, we used the Mimics program, and designed the molding box by a reverse engineering technique. We evaluated the range of motion and pain using a Constant score. The mean abduction was $50^{\circ}$($40^{\circ}-60^{\circ}$), forward flexion was $50^{\circ}$ ($30^{\circ}-70^{\circ}$), and average Constant score was 47.75 (44-52). Three-dimensional printed molding technique is one of the effective methods for humeral head osteomyelitis allowing for daily activities prior to the second surgery.

The Analysis of Drop-On-Demand Characteristic of Electrostatic Field Induced Inkjet Head System with Carbon Nano Tube (CNT) Ink (정전기장 유도된 잉크젯 프린터 헤드를 이용한 탄소나노튜브 잉크의 Drop-On-Demand 특성 연구)

  • Choi, J.Y.;Kim, Y.J.;Son, S.U.;Kim, Y.M.;Byun, D.Y.;Ko, H.S.;Lee, S.H.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1445-1449
    • /
    • 2007
  • This paper presents the DOD (Drop-On-Demand) characteristic using the electrostatic field induced inkjet printing system. In order to achieve the DOD characteristic of electrostatic field induced inkjet printing, applied the bias voltage of 1.4 kV and the pulse voltage of $2.0\;kV\;{\sim}\;2.7\;kV$ using high voltage pulse generator. Electrostatic field induced droplet ejection is directly observed using a high-speed camera and for investigated DOD characteristic, CNT ink used. The electrostatic field induced inkjet head system has DOD characteristic using pulse generator which can be applied pulse voltage. The bias voltage has a good condition which form meniscus and has micro dripping mode for small size micro droplet. Also, the droplet size decreases with increasing the applied pulse voltage. This paper shows DOD characteristic at electrostatic field induced inkjet head system, Therefore. electrostatic DOD inkjet head system will be applied industrial area comparing conventional electrostatic inkjet head system.

Modeling HRTFs for Customization (맞춤형 머리전달함수 구현을 위한 모델링 기법)

  • Shin, Ki-H.;Park, Young-Jin;Park, Yoon-Shik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.641-644
    • /
    • 2005
  • This study reveals some recent attempt in modeling empirically obtained B&K HATS (Head and Torso Simulator) HRTFs (Head Related Transfer Functions) to Isolate parameters that stimulate lateral and elevation perception. Localization using non-individual HRTFs often yields poor performance in synthesizing virtual sound sources when applied to a group of individuals due to differences in size and shape of head, pinnae, and torso. For realization of both effective and efficient virtual audio it is necessary to develop a method to tailor a given set of non-individual HRTFs to fit each listener without measuring his/her HRTF set. Pole-zero modeling is applied to fit HRIRs (Head Related Impulse Responses) and modeling criterions for determining suitable number of parameters are suggested for efficient modeling. Horizontal HRTFs are modeled as minimum-phase transfer functions with appropriate ITDs (Interaural Time Delay) obtained from RTF (Ray Tracing Formula) to better fit the size of listener's head for usage in simple virtualizer algorithms without complex regularization processes. Result of modeling HRTFs in the median plane is shown and parameters responsible for elevation perception are isolated which can be referred to in the future study of developing customizable HRTFs.

  • PDF

Construction and characterization of the bacteriophage P4 derivatives whose genome size suitable for packaging into a P2sir3-sized head (P2 sir3-sized head에 packaging 되기 용이한 크기의 박테리오파지 P4 유도체 조성과 정성 연구)

  • Kim, Kyoung-Jin
    • Korean Journal of Microbiology
    • /
    • v.51 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • The term "P2 sir-associated helper inefficiency" has been used to define the inefficient helper capability of P2 sir mutants for their satellite bacteriophage P4. The aim of this study was to investigate the factors overcoming P2 sir-associated helper inefficiency. At first, we verified whether the P2 cos region containing P4 sid71 cosP2 could overcome P2 sir-associated helper inefficiency with P2 sir3. The result was that P4 sid71 cosP2 could not overcome P2 sir-associated helper inefficiency with P2 sir3. Instead of cos region of P2, the size of the DNA packaged into a $P2_{sir}$-sized head seems to be important for overcoming P2 sir-associated helper inefficiency. In the present work, three kinds of P4 derivatives with packaged DNA sizes between those of P4 ost1 and P4 ost2, were constructed through DNA manipulation. In one P4 derivative, P4 sid71 delRI::apr, the size of the packaged DNA was identified with a CsCl buoyant equilibrium density gradient experiment. According to the burst sizes of the P4 derivatives, they could overcome P2 sir3-associated helper inefficiency. The size of the P4 derivative DNA suitable for packaging into a $P2_{sir3}$-sized head was 28-29 kb.

A Development of TIER-LII Sensor Head Design for Diesel Soot Size Measurement (디젤 soot의 크기 측정을 위한 TIER-LII 센서헤드 설계기술 개발)

  • Seo, Dong-Kyu;Kim, Deok-Jin;Chung, Jea-Woo;Yoon, Yeo-Seong;Lee, Chun-Beom
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.215-220
    • /
    • 2004
  • The TIER-LII system was established and evaluated using carbon black for diesel particulate size measurement. It contains a new designed sensor head which makes it easier to be measured. Through LII signal analysis of some parameters, we can understand that there were few correlations observed in effect of temperature, shield gas flow rate, and mixture flow rate.. However, an amount of difference was observed in different size of particulates.

  • PDF

Comparison between a spherical head model and a prolate spheroidal head model used in HRTF customization (맞춤형 머리전달함수에 사용될 수 있는 장구 회전타원체 형상 머리모델과 구형 머리모델 간의 비교)

  • Jo, Hyun;Park, Young-Jin;Park, Youn-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1009-1013
    • /
    • 2007
  • To do a HRTF customization, researchers used a spherical head model for modeling the head block of structural modeling of HRTF, which is the one of the technique for HRTF customization, because of its simplicity. In this paper, an analytic spheroidal HRTF caused by an incident point source will be introduced. Using proposed spheroidal HRTF, near-field HRTF customization can be applicable through a structural modeling of HRTF. To see the necessity of sheroidal head model, comparison of two analytic solutions, which are classical spherical HRTF and proposed spheroidal HRTF, will be shown. On the view point of ITD, optimal head model which matches with the measured ITD of KEMAR HRTF can be obtained. ITD results show that there are only slight differences between spherical and spheroidal head model. Magnitude comparison is made by constructing head model using measured head size. Although magnitude comparison is not studied between optimal models, the results of 24 of 36 subjects are shown that spheroidal head model matches notch frequency pattern of measured HRTF better than those of spherical one, where the sound source is at contralateral position.