• Title/Summary/Keyword: harmonic structure

Search Result 584, Processing Time 0.027 seconds

Equivalent Viscous Damping Ratio of a Friction Damper Installed in a SDOF Building (단자유도 건물에 설치된 마찰감쇠기의 등가점성감쇠비)

  • Seong, Ji-Young;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.2
    • /
    • pp.199-208
    • /
    • 2010
  • A friction damper installed at a building shows nonlinear behavior since its stick and slip states are occurred repeatedly depending on the amplitude of external loadings to dissipate input energy. Friction damping is existed for the building with a friction damper. In additionally viscous one is inherently included. Therefore, the building installed in such combined damping is quite involved to find the analytical solution. In this study, first, displacement and acceleration characteristics are identified based on the exact solution for a single-degree-freedom building with a friction damper having both friction and viscous damping. Second, in free vibration, the equivalent viscous damping ratio is obtained by the energy dissipation. Third, numerical analysis is carried out to find response configuration with various friction force ratios. Fourth, corresponding equivalent viscous damping ratio is derived with the finding that the response reaches into steady-state for both friction and viscous damped structure. It is deduced using balance of input external energy and output dissipation energy for steady-state response. Finally, the equivalent viscous damping ratios of free or harmonic vibration are verified through nonlinear analysis.

Design of High-Power and High-Efficiency Broadband Amplifier Using 1:4 Transmission Line Transformer (1:4 전송 선로 트랜스포머를 이용한 고출력 고효율 광대역 전력 증폭기의 설계)

  • Kim, Kyung-Won;Seo, Min-Cheol;Cho, Jae-Yong;Yoo, Sung-Cheol;Kim, Min-Su;Kim, Hyung-Cheol;Oh, Jun-Hee;Sim, Jae-Woo;Yang, Youn-Goo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.2
    • /
    • pp.121-128
    • /
    • 2010
  • This paper presents a design of a 100 W high-efficiency power amplifier, whose operational frequency band expands from 30 to 512 MHz, using negative feedback network, push-pull structure, broadband RF choke, and transmission line transformer for balun configuration. The push-pull amplifier has been tuned for higher output power using a shunt capacitor as a matching component at its load especially for high-frequency region. The implemented power amplifier exhibited a very flat power gain of $18.34{\pm}0.9\;dB$ throughout the operating frequency band and very high power-added efficiency(PAE) of greater than 40% at an output power of 100 W. It also showed second- and third-harmonic distortion levels of below -34 dBc and -12 dBc, respectively, through the entire operating frequency band.

Low-Pass Filter with Wide Stop-Band Characteristics Using Controllable Transmission Zeros (제어 가능한 전송 영점을 이용한 광대역 차단 특성을 갖는 저역 통과 필터)

  • Lee, Geon-Cheon;Kim, Yu-Seon;Kim, Kyung-Keun;Lee, Tae-Sung;Na, Hyeon-Sik;Lim, Yeong-Seog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.8
    • /
    • pp.887-894
    • /
    • 2007
  • In this paper, design and fabrication of the LPF with controllable four transmission zeros using electric coupling and added open stub is presented. Pass-band of the LPF is GSM band, and two transmission zeros are generated by the electric coupling at the WiBro and S-DMB band, And the other two transmission zeros are generated by the open stub at the upper frequencies. Harmonic frequency of the stop-band is suppressed by the realization of the filter using quasi-lumped element with small parasitic values. $C_M$, which is the electric coupling element of the equivalent circuit, is realized by the distance control between the open stubs of the filter structure. The fabricated LPF used teflon substrate with relative permittivity of 2.6. And it has a size of $38{\times}20{\times}0.79 mm^3$, which is including a feed line. The measured 3 dB cut-off frequency is 1.55 GHz, and locations of the transmission zeros are 2.20, 2.43, 4.11 and 6.84 GHz, respectively.

Determination and Analysis Sea Surface Topography for Unification Vertical Datum in East-Asia Area (동아시아지역 수직기준 통일을 위한 해면지형 결정 및 분석)

  • Huang, He;Yun, Hong-Sic;Lee, Dong-Ha
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.3
    • /
    • pp.207-217
    • /
    • 2008
  • The SSTop (Sea Surface Topography) provides an estimate of the large scale structure of the deviations between the geoid height and the mean sea surface in terms of a normalized surface spherical harmonic series. The SSTop is the key information which has been used to determine the shape of earth, geoid, current and tide etc. Also, the SSTop is a basic source for the unification of vertical datums at the different height systems which were established according to the their respective purposes. In order to unify the vertical datum around the East-Asian (E-A) region (covers the area: $20^{\circ}-45^{\circ}N$ and $110^{\circ}-140^{\circ}E$), we estimated the value of SSTop in the E-A region using the predicted values of mean sea surface (from KMSS04) and geoid height (from EGM96 and EIGEN-GL04C) and analyzed to aspect of SSTop at 5 tidal stations (InCheon, JeJu, QingDao, Aburatsubo, KeeLung) with the estimated values of each station previously. The result from this study indicates that the SSTop in the E-A region is relatively stable except for the area around the Japanese and Ryukyu deep, and also shows that the distribution of values of SSTop is ranged from 40 to 60 cm at tidal stations except InCheon station.

Evaluation of Quantitative Image Quality using Frequency and Parameters in the Ultrasound Image (초음파영상에서 주파수와 파라미터를 이용한 정량적 영상평가)

  • Kim, Changsoo;Kang, Se Sik;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.247-253
    • /
    • 2016
  • Ultrasound devices diagnose many disease, which is widely used, can not be standardized quantitative evaluated in order to evaluate sonography image of quality. Therefore, in this papers, aims to get correct image in order to accurate diagnosis by figuring out the appropriate parameter based on each target by measuring distortion which results in the analyzation of the sensitivity of SNR and the histogram of signal by manipulating parameter of 8 mm target in ATS-539 multipurpose phantom. Equipment using Acuson sequoia 512, convex probe and utilizes multi-objective phantom. experiment method is that first you put the phantom on the flat and acquire 85 sheets of image, changing frequency(2,3,4 MHz, harmonic 3, 4, 4.5 MHz), Focus(2, 4, 6 unit), and Dynamic Range(58, 68, 78, 88, 98) for a 8 mm structure. through the Image J program. The sensitivity angle of 8mm target through Image J program is gauged by each separate target SNR and the distorted angle subtract and measure Histogram of background from Histogram of signal and take top 40% from the given result value above. According to parameter variation we found out proper parameter by acquiring SNR of sensitivity and distortion data for aspect of transition. The more this findings have Focus, the lower distortion value and at 4 MHz frequency this result have high SNR and low distortion value. Dynamic Range got an appropriate image on 88 and 98. It is considered on the basis of the experimental data, the probability of disease diagnosis will get higher.

Second Order Nonlinear Optical Polyimides Containing Organic Chromophores with an Oxadiazole Segment (옥사디아졸 결합의 유기 발색단이 도입된 이차비선형 광학 이미드 고분자)

  • Do, Jung Yun;Kim, Bong Gun;Kwon, Ji-Yun
    • Applied Chemistry for Engineering
    • /
    • v.18 no.1
    • /
    • pp.77-83
    • /
    • 2007
  • It is essential that second order nonlinear optical materials have low optical propagation losses in the wavelengths of second harmonic generation for practical applications in waveguides. Three dipolar chromophores substituted with nitro, cyano, and alkyl sulfone as an electron withdrawing group were prepared. The UV-Vis absorption spectra of the cyano and alkylsulfone chromophores showed a blue-shift compared to the nitro chromophore. The introduction of oxadiazole segment in the chromophore structure led to similar spectral shift. The blue-shift can produce low optical loses at second harmonics. The chromophores were successfully attached to a polyimide, yielding side chain polymers. The nonlinear optical property of the prepared optical polymers was determined by measuring electro-optic coefficient at 1.55 mm. The polymers exhibited high glass transition temperature of over $185^{\circ}C$ and thermal stability to $300^{\circ}C$ through differential scanning calorimeter analysis and thermal gravimetric analysis.

Design of In-Wheel Motor for Automobiles Using Parameter Map (파라미터 맵을 이용한 차량용 인휠 전동기의 설계)

  • Kim, Hae-Joong;Lee, Choong-Sung;Hong, Jung-Pyo
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.3
    • /
    • pp.92-100
    • /
    • 2015
  • Electric Vehicle (EV) can be categorized by the driving method into in-wheel and in-line types. In-wheel type EV does not have transmission shaft, differential gear and other parts that are used in conventional cars, which simplifies and lightens the structure resulting in higher efficiency. In this paper, design method for in-wheel motor for automobiles using Parameter Map is proposed, and motor with continuous power of 5 kW is designed, built and its performance is verified. To decide the capacity of the in-wheel motor that meets the automobile's requirement, Vehicle Dynamic Simulation considering the total mass of vehicle, gear efficiency, effective radius of tire, slope ratio and others is performed. Through this step, the motor's capacity is decided and initial design to determine the motor shape and size is performed. Next, the motor parameters that meet the requirement is determined using parametric design that uses parametric map. After the motor parameters are decided using parametric map, optimal design to improve THD of back EMF, cogging torque, torque ripple and other factors is performed. The final design was built, and performance analysis and verification of the proposed method is conducted by performing load test.

Three key factors for successful esthetic anterior implant restoration (성공적인 전치부 심미 임플란트를 위한 3가지 요소)

  • Lim, Pil
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.35-49
    • /
    • 2016
  • With the increasing demand for aesthetic implant dentistry, the importance of implant restoration is emphasized not only in the functional aspect but also in the aesthetic aspect. The aesthetic restoration of dental implants in the anterior maxilla is a challenge for clinicians because it requires proper harmony in three following conditions; reconstruction of hard tissue, soft tissue, and aesthetic prosthesis. The soft tissue aesthetics are dependent upon the condition of the supporting hard tissue because the osseous structure provides a framework for the development of a healthy and aesthetic soft tissue interface. Therefore, the augmentation of hard tissue is a first step and especially, optimal 3-dimensional position of implant is the most important factor in aesthetic implant restoration. The management of soft tissue is a second step, and the final step is a restoration of harmonic prosthesis using provisional restoration with proper emergence profile. This clinical report describes the procedure of bone augmentation in labial dehiscence defect, Vascularized Interpositional Periosteal-Connective Tissue (VIP-CT) flap for aesthetic anterior soft tissue, and the importance of provisional restoration and impression taking stage with customized impression coping.

Fabrication and Characterization of Wavelength Conversion Device with Periodically Poled Ridge-type Waveguide in MgO:LiNbO3 (주기적으로 분극 반전된 MgO:LiNbO3를 이용한 리지형 광도파로 파장가변 소자 제작 및 특성)

  • Lee, H.M.;Yang, W.S.;Kim, W.K.;Lee, H.Y.;Jeong, W.J.;Kwon, S.W.;Koo, K.H.;Song, M.G.
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.3
    • /
    • pp.199-207
    • /
    • 2008
  • Wavelength converting devices with a ridge-type waveguide in periodically poled $MgO:LiNbO_3$ are made and characterized. The experimental results are compared with theoretical analysis on the effects of waveguide dimension and duty ratio of the periodically poled structure. To show the relationship of the conversion efficiency to those factors, a new measurement system is configured. That experimental results show that the center wavelength, normalized conversion efficiency and full width half maximum of the conversion efficiency curve are 1067.45 nm, 90.7%/$Wcm^2$ and 0.17 nm, respectively. Also, the estimated results of the duty period and full width half maximum of the conversion efficiency from theoretical calculations agreed well with experimental results with the errors of 0.016 ${\mu}m$ and 0.01 nm.

Velocity Distribution Measurements in Mach 2.0 Supersonic Nozzle using Two-Color PIV Method (Two Color PIV 기법을 이용한 마하 2.0 초음속 노즐의 속도분포 측정)

  • 안규복;임성규;윤영빈
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.4
    • /
    • pp.18-25
    • /
    • 2000
  • A two-color particle image velocimetry (PIV) has been developed for measuring two dimensional velocity flowfields and applied to a Mach 2.0 supersonic nozzle. This technique is similar to a single-color PIV technique except that two different color laser beams are used to solve the directional ambiguity problem. A green-color laser sheet (532 nm: 2nd harmonic beam of YAG laser) and a red-color laser sheet (619 nm: output beam from YAG pumped Dye laser using Rhodamine 640) are employed to illuminate the seeded particles. A high resolution (3060${\times}$2036) digital color CCD camera is used to record the particle positions. This system eliminates the photographic-film processing time and subsequent digitization time as well as the complexities associated with conventional image shifting techniques for solving directional ambiguity problem. The two-color PIV also has the advantage that velocity distributions in high speed flowfields can be measured simply and accurately by varying the time interval between two different laser beams due to its high signal-to-noise ratio and thereby less requirement of panicle pair numbers for a velocity vector in one interrogation spot. The velocity distribution in the Mach 2.0 supersonic nozzle has been measured and the over-expanded shock cell structure can be predicted by the strain rate field. These results are compared and analyzed with the schlieren photograph for the velocity distributions and shock location.

  • PDF