• Title/Summary/Keyword: harmonic reduction.

Search Result 426, Processing Time 0.025 seconds

A Study on the series Active Power Filter for Harmonic Reduction of 3-Phase 3-Wire System (3상 3선식 시스템의 고조파 저감을 위한 직렬형 능동전력필터에 관한 연구)

  • 한윤석
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.735-738
    • /
    • 2000
  • In this paper we propose a series active power filter and a simple calculation method acquiring the reference voltage. A series active power filter is suitable to suppress harmonics produced by voltage type harmonic source such as a diode rectifier with filter capacitor on the DC side The proposed series active power filter system is applied to 3-phase 3-wire power system including the voltage type harmonic source. Experimental result obtained from a laboratory model are shown to verify the viability and effectiveness of the proposed system.

  • PDF

A study of Single-phase Voltage Source PWM Converter for High Power Factor (고역률 제어를 위한 단산 전압원 PWM 컨버터에 관한 연구)

  • 류성식;손진근;정을기;김형원;전희종
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.362-365
    • /
    • 1999
  • In this paper, the method of reducing harmonics and correcting of power factor in single PWM converter associated with diode rectifier and boos converter is studied. The ac-dc converter in which the harmonic distortion in the input current is reduced using a third harmonic injected PWM is proposed. A lower switching power loss and easy configuration o control circuit are obtained by adopting discontinuous current mode. Simulation and experimental results of ac-dc converter with 5[KHz] switching frequency are presented and correction of power factor and reduction of total harmonic distortion was established.

  • PDF

High Speed Induction Motor Driving for using AM PWM (AM PWM을 이용한 고속 유도 전동기 구동)

  • 김민태;최재동;김영호;성세진;전칠환
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.380-383
    • /
    • 1998
  • Amplitude Modulation PWM Technique which has characteristics such as the switching loss and Harmonic distortion reduction is compared in this paper. And also Harmonic components only carrier frequencies. And as it is showed Harmonic components only carrier frequencies via simulation results. Am-pwm is applied to the inverter system of High-speed induction motor.

  • PDF

Adaptive Harmonic Control for DC Input Voltage Fluctuation of PWM Inverter (PWM인버터의 DC입력전달 맥동에 대한 고조파 적응제어)

  • 이윤종;임남혁
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.11
    • /
    • pp.896-904
    • /
    • 1989
  • PWM techniques which eliminate and reduce harmonics of output voltage in PWM Inverter driving System with fluctuating input volotage are described. First, harmonic factors are analyzed from harmonic equation of general PWM waveform and by examination of control possiblity of each factor, controllable factor is selected. Applying controllable factor to NPWM, PWM techniques using reference wave and carrier wave modulation are introduced. Actually, by the experiment applied with this strategy, the reduction of harmonics of output voltage is confirmed.

  • PDF

MRSF-PWM Method for Acoustic Noise Reduction of Traction Motor Drive Systems (견인전동기 구동시스템의 소음 저감을 위한 MRSF-PWM 방식)

  • 홍순찬;서영민
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.262-271
    • /
    • 2002
  • In PWM inverters used in traction motor drive systems, the switching frequency is restricted by their large power capacity and thus the electromagnetic acoustic noise is generated. To reduce such an audible noise, the new MRSF-PWM(Modified Random Switching Frequency PWM) method is proposed. In the Proposed MRSF-PWM method, both triangular wave and sawtooth wave are used together as carrier waves for harmonic diffusion and reference wave is generated by injecting 3rd harmonic into the stone wave to expand the linear control region of output voltages. To verify the validity of the proposed MRSF-PWM method, computer simulations are carried out. And the results show that the MRSF-PWM method is more excellent than other RPWM methods in the aspects of both linearity and harmonic diffusion md more effective than SPWM(Sinusoidal PWM) method for the reduction of an audible noise.

Frequency Analysis and Reduction of Electronic Noise in ESS (ESS의 전자 잡음 주파수 분석 및 제거)

  • Ahn, Bong Man;Han, Byoung Sung;Han, Un Ki;Lee, Young Kwan;An, Hyun Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.6
    • /
    • pp.568-575
    • /
    • 2022
  • This paper is a study on frequency analysis and electronic noise reduction of energy storage system (ESS). We acquired 4 necessary data for about 2 minutes and 4 seconds using a sampling frequency of 10,000 Hz in ESS. Fast Fourier transform (FFT) was used for electronic noise analysis from the acquired data. As a result, it was confirmed that DC component, fundamental wave, second and higher harmonic component exist. For the attenuation of harmonics, low-pass filter (LPF) was applied. We confirmed that an attenuation of approximately 59.3% appears from the second harmonic. The presence of many harmonic components in the data of the ESS was expected to occur due to the insufficiency of optimization among the modules inside the ESS. Therefore, we propose that a national certification system for ESS should be introduced to settle down the issue properly.

A Harmonic Suppressed Design of Size Reduced Ring-Hybrid Using Folded Line Structure (소형화 및 고조파 특성이 개선된 접힌 구조의 링-하이브리드의 설계)

  • Lee Hong-Seop;Lee Chul-Heui;Hwang Hee-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.9 s.112
    • /
    • pp.845-851
    • /
    • 2006
  • Folded lines are applied to design a compact microstrip ring hybrid. Using the proposed structure we achieve both significant size reduction and good harmonic suppression with the same results of conventional ring hybrid at 2.41 GHz. Including the third harmonic frequency, up to 11 GHz band harmonics are suppressed to -20 dB. The size of the proposed ring-hybrid is reduced to one forth of the conventional ring hybrid. The measured frequency responses agree well with simulated ones.

New Generalized PWM Schemes for Multilevel Inverters Providing Zero Common-Mode Voltage and Low Current Distortion

  • Nguyen, Nho-Van;Nguyen, Tam-Khanh Tu
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.907-921
    • /
    • 2019
  • This paper presents two advanced hybrid pulse-width modulation (PWM) strategies for multilevel inverters (MLIs) that provide both common-mode voltage (CMV) elimination and current ripple reduction. The first PWM utilizes sequences that apply one switching state at the double ends of a half-carrier cycle. The second PWM combines the advantages of the former and an existing four-state PWM. Analyses of the harmonic characteristics of the two groups of switching sequences based on a general switching voltage model are carried out, and algorithms to optimize the current ripple are proposed. These methods are simple and can be implemented online for general n-level inverters. Using a three-level NPC inverter and a five-level CHB inverter, good performances in terms of the root mean square current ripple are obtained with the proposed PWM schemes as indicated through improved harmonic distortion factors when compared to existing schemes in almost the entire region of the modulation index. This also leads to a significant reduction in the current total harmonic distortion. Simulation and experimental results are provided to verify the effectiveness of the proposed PWM methods.

Winding Method of Transformer for Zero-Sequence and Negative-Sequence Harmonic Elimination (영상분 및 역상분 고조파 제거를 위한 변압기 결선방식)

  • Kim, Tae-Hoon;Park, Jun-Yeal
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.896-902
    • /
    • 2014
  • As the various kinds of load who generate higher harmonics increases according as the power electronics technology develops, harmonic treatment standard is proposed by IEEE and IEC. Because establishment of harmonic reduction device is required for existent installment to satisfy harmonic treatment standard, the problem of investment charge and installation space increasing may be occurred. In order to solve these problems, a novel transformer connection method using principles of PCT and ZED is suggested.

Analysis of Impedance Performance for Condenser by Harmonic Current Source (고조파 전류원에 의한 콘덴서 임피던스 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.57-64
    • /
    • 2011
  • Most of the user has been used linear load and non-linear load. The former is usually inductive load which is needed power factor compensation, the latter is power conversion system device. Actually two kinds of load is used together in the customer application. Generally capacitor is used for power-factor compensation of inductive load and reduction harmonics of non linear load with reactor. Non-linear load generates harmonic current for its energy conversion process. If harmonic current pass along the low impedance side of distribution system, the magnification of voltage and current is appeared by the series and parallel resonance. As a result, condenser has received a bitter electrical stress by the harmonic component. In this paper, we analyzed that how resonance is changed by the 5-th harmonic current pattern and proposed an alternative plan for non-magnification.