• 제목/요약/키워드: harmonic performance.

검색결과 838건 처리시간 0.033초

직류 부하에 대한 3상 복합형 전력 필터 설계 (A Design of Three-phase Hybrid Power Filter System for DC Loads)

  • 조동길
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 춘계학술대회논문집 - 한국공작기계학회
    • /
    • pp.379-384
    • /
    • 2000
  • The reactive and harmonic current components of dc loads can be compensated by the three-phase hybrid power filter (HPF) system. After compensation, the resulting current has sinusoidal and in-phase components with the source voltage. The HPF system is constructed by an active filter and passive filters. The passive filter reduce the 5th and 7th harmonic of the load current. The active filter compensates the remainder of the load current. Using the HPF system, a low cost harmonic compensator can be made. Performance of the HPF system is verified through simulation,

  • PDF

A Study on High Current Rectifier Systems with Mitigated Time-Varying Magnetic Field Generation

  • 김창우;서용석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.232-233
    • /
    • 2010
  • This paper investigates occupational exposure to time-varying magnetic field generation in high power rectifier systems. Two different kinds of high power rectifier systems of 25kA are modeled and analyzed. The performance is compared and evaluated on the basis of exposure guidelines from ICNIRP. In order to focus on the qualitative effect of rectifier operation, the mechanical structure of current carrying conductors is simplified as infinite long bus-bar model and low frequency harmonic contents up to 65kHz are considered. Thyristor rectifier generates a significant amount of low frequency magnetic field harmonic contents both at ac and dc side of rectifier infringing the limit from ICNIRP. The multilevel rectifier-IGCT type has almost negligible field generation from ac input side and smaller harmonic contents in dc load side complying with ICNIRP guideline. This remarkable advantage of multilevel rectifier-IGCT type can lead to very simple site layout design for installation and cost-effective compliance to guideline of occupational exposure against magnetic field.

  • PDF

A Multiband Shunt Hybrid Active Filter with Sensorless Control

  • Kumar S, Surendra;Sensarma, Partha Sarathi
    • Journal of Power Electronics
    • /
    • 제8권4호
    • /
    • pp.317-324
    • /
    • 2008
  • This paper proposes a Multiband Shunt Hybrid Active Filter (SHAF) with sensorless control. A plant is modeled in the discrete- time domain and a controller is designed using the Pole shifting law in the polynomial domain. This control approach is very useful for filtering the load harmonics with reduced sensor counts where a low cost solution like SHAF is required. Multiple Synchronous Reference Frames (MSRF) and low pass filters are used to measure the $5^{th}$ and $7^{th}$ harmonic components separately from the load and filter currents. Individual current controllers are designed for the $5^{th}$ and $7^{th}$ harmonic currents. Control is realized in the stationary, three-phase (abc) reference frame. Performance of the controller is validated through simulation, using realistic plant and controller models, as well as experimentally on a full-scale distribution system.

A Novel Hybrid Active Power Filter with a High-Voltage Rank

  • Li, Yan;Li, Gang
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.719-728
    • /
    • 2013
  • A novel hybrid active power filter (NHAPF) that can be adopted in high-voltage systems is proposed in this paper. The topological structure and filtering principle of the compensating system is provided and analyzed, respectively. Different controlling strategies are also presented to select the suitable strategy for the compensation system. Based on the selected strategy, the harmonic suppression function is used to analyze the influence of system parameters on the compensating system with MATLAB. Moreover, parameters in the injection branch are designed and analyzed. The performance of the proposed NHAPF in harmonic suppression and reactive power compensation is simulated with PSim. Thereafter, the overall control method is proposed. Simulation analysis and real experiments show that the proposed NHAPF exhibits good harmonic suppression and reactive power compensation. The proposed compensated system is based on the three-phase four-switch inverter, which is inexpensive, and the control method is verified for validity and effectiveness.

전류 고조파와 불평형 전원 전압 보상을 위한 직렬형 능동전력필터에 관한 연구 (A Study on the Series Active Power Filter for Harmonic Reduction and Unbalanced Source Voltage Compensation)

  • 오재훈;한윤석;김영석;원충연;최세완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.191-194
    • /
    • 2001
  • In this paper, we propose a series active power filter control method to compensate current harmonics and unbalanced source voltage. The system is composed of series active power filter and shunt passive filer that are tuned 5th and 7th harmonics. In this conventional system, series active power filter complements drawbacks of the shunt passive filter, namely improves harmonic compensation characteristics, and compensates unbalanced source voltage. In the proposed algorithm, compensation voltage for harmonic reduction is calculated by performance function, and compensation voltage for unbalanced source voltage is calculated in based on a synchronous reference frame. So, ultimate compensation voltage is sum of those two compensation voltages. By computer simulation, we verify the excellency of proposed method.

  • PDF

능동전력필터기능을 갖는 UPS에 관한 연구 (A Study on UPS with Active Power Filter Function)

  • 박인석;이정준;성낙규;오봉환;김성남;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2178-2180
    • /
    • 1998
  • Recently, for increasing consumed power and informational society, confidence of power supply is demanded. Beside, owing to most of these loads are nonlonear, utility line is polluted by these components, therefore, it is demanded compensation of harmonic current. In times past, special order of harmonic current is only compensated by passive filter, but active power filter can compensate whole harmonic current. Therefore, this paper propose uninterruptable power supply(UPS) with performance of active power filter.

  • PDF

독립형 마이크로그리드에서 비선형 부하에 대한 고품질 전압제어 (Effective Voltage Quality Control under Nonlinear Loads in Islanded Microgrid)

  • ;이홍희
    • 전력전자학회논문지
    • /
    • 제21권6호
    • /
    • pp.465-472
    • /
    • 2016
  • A nonlinear load causes harmonic distortion and hampers the performance of other loads or distributed generation (DG) sources connected to the point of common coupling (PCC). This study proposes a new control strategy to reduce harmonic components, such as fifth and seventh harmonics, at the PCC under nonlinear loads in islanded microgrids, which comprise more than two DG sources. The proposed control scheme enables the DG source to share the power commanded by the control center as well as to compensate for the voltage harmonics at the PCC. The reference current is estimated from the voltage harmonics and injecting power; thus, the control scheme is implemented without any additional hardware devices. The simulation and experimental results are presented to verify the effectiveness of the proposed control method.

유리수차 조화 모드잠김 광섬유 링레이저로부터 발생된 교차 위상 RZ(return-to-zero) 신호의 분산 제어 전송 (Dispersion tolerant transmission of the return-to-zero signal with alternate-phase generated from a rational harmonic mode-locked ring laser)

  • 조현정;황종규;김백현;백종현
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.203-204
    • /
    • 2006
  • We present and demonstrate a novel method of alternate-phase return-to-zero (RZ) signal generation and pulse-amplitude equalization simultaneously in a rational harmonic mode-locked fiber ring laser, using a dual-drive Mach-Zehnder (MZ) modulator. By adjusting the voltages applied to both arms of the modulator, the rational harmonic mode-locked pulse trains are equalized in their amplitudes. In addition to that, the amplitude-equalized pulse trains multiplying the repetition rate at ${\sim}10\;GHz$ have alternate $\pi$ phase difference between adjacent pulses. The alternate-phase RZ signal generated by the proposed method enhances transmission performance through the single-mode fiber (SMF) links without dispersion compensation.

  • PDF

A Single-Phase Unified Power Quality Conditioner with a Frequency-Adaptive Repetitive Controller

  • Phan, Dang-Minh;Lee, Hong-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.790-799
    • /
    • 2018
  • This paper proposes a single-phase unified power quality conditioner (S-UPQC) for maintaining power quality issues in a microgrid. The S-UPQC can compensate the voltage and current harmonics, voltage sag, and swell as a dynamic voltage restorer (DVR), regardless of variations in the grid frequency. Odd harmonics are treated as even-order harmonics in a rotating frame to implement the harmonic compensators with only one repetitive controller (RC) without any harmonic extractor. The dynamic performance is improved and the delay time is reduced in the RC. The S-UPQC control scheme is designed to maintain accurate and stable operation under deviations of the grid frequency by using the Lagrange interpolation-based finite-impulse-response (LIFIR) filter approximation method. The proposed control schemes were validated through a simulation and experiment.

Voltage Source Inverter Drive Using Error-compensated Pulse Width Modulation

  • Chen, Keng-Yuan;Hu, Jwu-Sheng;Lin, Jau-Nan
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.388-397
    • /
    • 2016
  • An error-compensated pulse width modulator (ECPWM) is proposed to improve the baseband harmonic performance and the switching loss of voltage source inverters (VSIs). Selecting between harmonic distortion and switching loss is a design tradeoff in the conventional space vector pulse width modulation. In this work, an accumulated difference in produced and desired phase voltages is considered to adjust the reference signal. This mechanism can compensate for the voltage error in the previous carrier period. With error compensation every half-carrier period, the proposed ECPWM allows one-half reduction in carrier frequency without scarifying baseband harmonic distortion. The proposed modulator is applied to a three-phase VSI with R-L load and a motor-speed-control system for experiments. The measured efficiency and operating temperature of switches confirm the effectiveness of the proposed scheme.