• Title/Summary/Keyword: hard power

검색결과 850건 처리시간 0.034초

소프트 스위칭 방식을 이용한 X-Ray용 DC-DC Converter에 관한 연구 (A Study on DC-DC Converter for X-Ray Using Soft-Switching Method)

  • 김학성;김현준;원충연;유동욱;하성운
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.379-381
    • /
    • 1994
  • This paper is concerned with a zero-voltage soft-switching PWM DC-DC high-pelter converter using IGBTs, which Bakes the most of the parastic LC parameters of high-voltage transformer link, for diagnostic X-Ray power generator. The converter circuit basically utilizes phase-shift pulse width modulated series resonant full-bridge PWM DC-DC high-Power converter operating at a constant frequency:20kHz. This technique brings about dramatic decreases in the switching losses of power devices and their electrical stresses as compared with the commonly-used hard-switching PWM DC-DC power converter. The high-frequency switching operation of the converters has some effective advantages, which consist in the physical reduction in size and weight and lowered acoustic noise.

  • PDF

Vertex Coloring based Slot Reuse Scheduling for Power Line Communications

  • Yoon, Sung-Guk
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2135-2141
    • /
    • 2015
  • Power line communication (PLC) is one of the major communication technologies in smart grid since it combines good communication capability with easy and simple deployment. As a power network can be modeled as a graph, we propose a vertex coloring based slot reuse scheduling in the time division multiple access (TDMA) period for PLCs. Our objective is to minimize the number of assigned time slots, while satisfying the quality of service (QoS) requirement of each station. Since the scheduling problem is NP-hard, we propose an efficient heuristic scheduling, which consists of repeated vertex coloring and slot reuse improvement algorithms. The simulation results confirm that the proposed algorithm significantly reduces the total number of time slots.

보호 계전기와 차단기의 동작 순서를 고려한 전력 시스템 사고 구간 진단을 위한 전문가 시스템 (An Expert System for Fault Section Diagnosis in Power Systems using the information including operating times of actuated relays and tripped circuit breakers)

  • 민상원;이상호;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.125-127
    • /
    • 2000
  • Multiple faults are hard to diagnose correctly because the operation of circuit breakers tripped by former fault changes the topology of power systems. The information including operating time of actuated relays and tripped circuit breakers is used for considering changes of the network topology in fault section diagnosis. This paper presents a method for fault section diagnosis using a set of matrices which represent changes of the network topology due to operation of circuit breakers. The proposed method uses fuzzy relation to cope with the unavoidable uncertainties imposed on fault section diagnosis of power systems. The inference executed by the proposed matrices provides the fault section candidates in the form of a matrix made up of the degree of membership. Experimental studies for real power systems reveal usefulness of the proposed technique to diagnose multiple faults.

  • PDF

Multi-Rate and Multi-BEP Transmission Scheme Using Adaptive Overlapping Pulse-Position Modulator and Power Controller in Optical CDMA Systems

  • Miyazawa Takaya;Sasase Iwao
    • Journal of Communications and Networks
    • /
    • 제7권4호
    • /
    • pp.462-470
    • /
    • 2005
  • We propose a multi-rate and multi-BEP transmission scheme using adaptive overlapping pulse-position modulator (OPPM) and optical power controller in optical code division multiple access (CDMA) networks. The proposed system achieves the multi-rate and multi-BEP transmission by accommodating users with different values of OPPM parameter and transmitted power in the same network. The proposed scheme has advantages that the system is not required to change the code length and number of weight depending on the required bit rate of a user and the difference of bit rates does not have so much effect on the bit error probabilities (BEPs). Moreover, the difference of transmitted powers does not cause the change of bit rate. We analyze the BEPs of the four multimedia service classes corresponding to the com­binations of high/low-rates and low/high-BEPs and show that the proposed scheme can easily achieve distinct differentiation of the service classes with the simple system configuration.

FLEX10K 계열에 대한 저전력 CPLD 기술 매핑 알고리즘 (Low Power CPLD Technology Mapping Algorithm for FLEX10K series)

  • 김재진;박남서;인치호;김희석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(2)
    • /
    • pp.361-364
    • /
    • 2002
  • In this paper, we consider the problem of CLB based CPLD technology mapping for power minimization in combinational circuit. The problem has been previously proved to be NP-hard, and hence we present an efficient heuristic algorithm for it. The main idea of our algorithm is to exploit the "cut enumeration" and "feasible cluster" technique to generate possible mapping solutions for the sub-circuit rooted at each node. However, for the consideration of both run time and memory space, only a fixed-number of solutions are selected and stored by our algorithm. To facilitate the selection process, a method that correctly calculates the estimated power consumption for each mapped sub-circuit is developed. The experimental results show that our approach is shown a decrease of 30.5% compared with DDMAP and that of 15.63% for TEMPLA in the Power consumption.

  • PDF

IGBT 인버터를 위한 향상된 단락회로 보호기법 (An Improved Short Circuit Protection Scheme for IGBT Inverters)

  • 서범석;현동석
    • 전력전자학회논문지
    • /
    • 제3권4호
    • /
    • pp.426-436
    • /
    • 1998
  • Identification of fault current during the operation of a power semiconductor switch and activation of suitable remedial actions are important for reliable operation of power converters. A short circuit is a basic and severe fault situation in a circuit structure such as voltage source converters. This paper presents a new active protection circuit for fast and precise clamping and safe shutdown of fault currents of the IGBTs. This circuit allows operation of the IGBTs with a higher on-state gate voltage, which can thereby reduce the conduction loss in the device without compromising the short circuit protection characteristics. The operation of the circuit is studied under various conditions, considering variation of temperature, rising rate of fault current, gate voltage value, and protection circuit parameters. An evaluation of the operation of the circuit is made using IGBTs from different to confirm the effectiveness of the protection circuit.

  • PDF

고체음원의 출력 예측방법에 대한 연구 (A Method to determine structureborne noise levels from machineries)

  • 김상렬;김재승;김현실;강현주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.545-550
    • /
    • 1997
  • It is well known that Statistical Energy Analysis(SEA) is one of very attractive analytical methods to solve shipboard noise problems. With reasonable successes, many applications of SEA to shipboard noise prediction have been reported. However when one wishes to obtain theoretical predictions by using SEA in practical systems, he will find difficulty in modeling of source systems, that is, foundations where to place main engine, generator, compressor, and so on. Also, he will find that it is hard to determine the amount of power flow from machinery to structures. In this paper, SEA of a simple foundation model was carried out using the estimated amount of power flow from source; the estimated mobility method. The comparison between the estimated and measured results is presented. That comparison shows a method to get structure-borne noise power from the combination of machinery and foundation. This prediction method gave a good results for a air-compressor mounted on a model foundation. The method is expected to give a reasonable power output in practical problems.

  • PDF

국가 경쟁력 강화를 위한 공장자동화의 기술개발 전략에 관한 연구 - 운반 하역 기계 산업 중심으로 (A Study on the Strategy of Technological Innovation to Enforce International Competitive Power for the Factory Automation - in the Industry of Automated Transportation and Stevedoring Machinery)

  • 신용하;이근희
    • 산업경영시스템학회지
    • /
    • 제18권36호
    • /
    • pp.205-218
    • /
    • 1995
  • The trends of economic business environment have been changed to the ultimate competion, diverse market and need of new technology. To enforce the international competitive power, continuous technology innovation should be propelled. But the characteristics of small and medium company make it hard to get lead of market share. The industry of transportation and stevedoring machinery also have the same situation as small and medium company. This paper try to present the way of competitive power. The Strategic technology innovation for the industry of transportation and stevedoring machinery consists of product strategy, process design strategy, infra-structure strategy and R&D. There are benefits and shortcommings to get the competitive power for the industry of transportation and stevedoring machinery. Therefore the onclusion presented that capital for reverse engineering, export policy, human resource, thechnical cooperation with the institutions are required.

  • PDF

A New High Power Factor ZVT-ZCT AC-DC Boost Converter

  • Ting, Naim Suleyman
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1539-1548
    • /
    • 2018
  • This paper introduces a new soft switched AC-DC boost converter with power factor correction (PFC). In the introduced converter, all devices are turned on and off under soft switching (SS). The main switch is turned on under zero voltage transition (ZVT) and turned off under zero current transition (ZCT). The main diode is turned on under zero voltage switching (ZVS) and turned off under zero current switching (ZCS). Meanwhile, there is not any current or voltage stress on the main devices. Besides, the auxiliary switch is turned on under ZCS and turned off under ZVS. The detailed theoretical analysis of the converter is presented, and also theoretical analysis is verified by a prototype with 100 kHz and 500 W. Also, the proposed converter has 99.8% power factor and 97.5% total efficiency at soft switching operation.

765kV 송전선로 유지.보수 활선공법 고찰 (765kV Transmission maintenance live-line work study)

  • 최한열;민병욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.723-724
    • /
    • 2007
  • Live line work is well known for mending and maintenance of electrical power equipment. Nowadays needs of electric power supply quality require live line work In Korea, live line work is needed since 765kV transmission operation and restructure of electric power industry has changed. In other words, in case of suspension of power supply on the transmission is getting hard to keep up with efficiency of transmission operation, customer's confidence and generation-limited cost. Therefore live line work is very meaningful. As the condition of 765kV Transmission both bare hand and Helicopter live line technique must be used in moderation because of economic, geographical, environmental circumstances around steel tower.

  • PDF