• Title/Summary/Keyword: hand lamp

Search Result 50, Processing Time 0.02 seconds

A Study on the Light Weight Hand Lamp for Explosion-Proof Type (휴대형 방폭등의 경량화 연구)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.31-36
    • /
    • 2013
  • For lighting of dark and hazardous workplace such as compartment of ships under construction, workers should use hand lamps of explosion-proof type. However, the heavy weight of such lamps has prevented most impatient workers from using such types of lamps extensively. In this paper, we developed a light weight hand lamp of intrinsic safety type which reduced the weight a lot while maintaining or improving the lighting and explosion-proof function. We made a prototype which consisted of lamp fixture and high frequency power supply. Testing results show that the hand lamp meets well all the explosion-proof testing requirements of the Korea Occupational Safety and Health Agency. And more, we surveyed the explosion protection technology of a light weight hand lamp, and suggested the advantage/disadvantage to apply lighting of hand lamp about economical aspect.

Improved Heat Lamp for Preventing Arterial Spasm after Microvascular Surgery (미세혈관 수술 후 혈관 연축의 예방을 위한 개선된 온열전등)

  • Ahn, Sung-Min;Hwang, So-Min;Hu, Eun-Suk;Park, Jung-Mi;Park, Kyung-A;Oh, Jin-A
    • Archives of Reconstructive Microsurgery
    • /
    • v.17 no.2
    • /
    • pp.120-125
    • /
    • 2008
  • Purpose: Heat therapy by heat lamp after microvascular surgery is being used for preventing blood vessels's contraction and blood-flow's disturbance. As usually, incandescent lamp has been used. But there have been several problems and need for improvement in the existing heat lamp treatment. So we would like to introduce improved heat lamp to keep an appropriate temperature and intensity of illumination. Methods: The existing heat lamps are the ones of general light stands covered with newspaper, having 60 watt light bulb of incandescence and lampshade made of aluminum. We have tried to improve shortcomings of the existing heat lamps by enlarging the size of aluminum lampshade and attaching a curtain that can block heat and light. We conducted a comparative study between the existing and improved heat lamps. Under the assumption that there are several affected parts, we have also measured the distance from heat lamp to patients' eye region and then intensity of illumination. Result: The target temperature of surface was realized in 11 minutes with the maximum temperature reaching at 36.6 degrees C in 28 minutes at the existing heat lamp while the target temperature reached in 7 minutes with the maximum temperature reaching at 39.0 degrees C in 17 minutes at the improved heat lamp. The existing and improved heat lamp showed 38 lx and 0.1 lx of intensity of lumination, respectively. Conclusion: Using improved heat lamps, we can keep an appropriate temperature and we think we can make contribution to patients' treatment by making them and their neighbors able to sleep with minimized disturbance thanks to low intensity of illumination secured by blocking light.

  • PDF

Development of a Light Weight Hand Lamp of Explosion-Proof Type (휴대용 방폭형 작업등의 경량화 연구)

  • 최상원;이관형;김명섭;임의수
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.11a
    • /
    • pp.135-142
    • /
    • 1997
  • For lighting of dark and hazardous workplaces such as compartments of ships under construction, workers should use hand lamps of explosion-proof type. However, the heavy weight of such lamps has prevented most impatient workers from using such types of lamps extensively. In this paper, ire developed a light weight hand lamp of intrinsic safety type which reduced the weight a lot while maintaining or improving the lighting and explosion-proof function. We made a Prototype which consisted of lamp fixture and low/high frequency power supply. Testing results show that the hand lamp meets well all the explosion-proof testing requirements of the Korea Industrial Safety Corporation.

  • PDF

Aging-Time Dependence of Color Rendering Index of a LED Lamp for Lighting (조명용 LED 램프의 사용 시간에 따른 연색지수 특성변화)

  • Son, Minwoo;Lee, Duck Hee;Seo, Jung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.1-6
    • /
    • 2014
  • We measured color rendering index(CRI) of a LED lamp for lighting for aging-time. We chose bulb type white LED lamp six samples and halogen lamp one sample and applied 220V, 60Hz to all the samples for 1,000hours at ordinary temperature. The CRI was measured every 20hours and the CRI change of the LED lamp was compared with the halogen lamp's CRI change. As time goes, efficiency of the halogen lamp decreased and the CRI maintained uniformly. The other hand, efficiency of the LED lamp decreased but the CRI increased. The CRI of the LED lamp has been stabilized since 600hours. The CRI change of the LED lamp was analyzed with a spectrum, color coordinate and color temperature.

Fishing efficiency of LED fishing lamp for squid Todarodes pacificus by training ship (실습선에 의한 LED 집어등의 오징어 어획성능)

  • An, Young-Il;Jeong, Hak-Geun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.3
    • /
    • pp.187-194
    • /
    • 2012
  • This study surveyed the fishing efficiency for Japanese common squid based on improvements made to LED fishing lamps by utilizing the training ship of Gangwon Provincial College. The training ship, Haesong-ho (24 tons), was equipped with seventy-two 150W electric power LED fishing lamps (10.8kW), and their fishing efficiency and fuel consumption level were surveyed for a total of ten times during the period between June 15, 2009 and July 27, 2009. In addition, the training ship was equipped with seventy-one 300W electric power LED fishing lamps (21.3kW) and their fishing efficiency and fuel consumption level were surveyed for a total of five times during the period between January 17, 2010 and August 4, 2010. In order to compare the fishing efficiency of LED fishing lamps, the catch of another fishing vessel equipped with Metal Halide (MH) fishing lamps of 120kW for the same period and at the same fishing grounds. The fuel consumption levels during the fishing operation of Haesong-ho was about 1,047.7 liters which was approximately 19.9% of the total fuel consumption level of 5,262.6 liters, and the fuel consumption level per operation hour was on average 9.2 liters. The number of Japanese common squid caught by the LED fishing lamp-equipped fishing vessel ranged from 12 to 1,640 squid for each fishing trial and the average quantity was 652. The number of Japanese common squid caught by the MH fishing lamp-equipped 10 fishing vessels ranged from 40 to 4,800 squid and the average quantity was 2,055. The fishing of Japanese common squid was done by the use of hand lines and an automatic jigging machine. The number of Japanese common squid caught per hand line and a single roller of the automatic jigging machine was in the proportion of 50.8% to 49.2% with respect to the LED fishing lamp-equipped fishing vessel. However, the number of Japanese common squid caught per hand line and a single roller of the automatic jigging machine was in the proportion of 86.4% to 13.6% with respect to the MH fishing lamp-equipped fishing vessel where most of the catch was made by hand lines. On the other hand, in comparing the number of Japanese common squid caught per automatic jigging machine, the number of squid caught by the LED fishing lamp-equipped fishing vessel was about the same or greater than the number of squid caught by the MH fishing lamp-equipped fishing vessel.

Catching efficiency of LED fishing lamp and behavioral reaction of common squid Todarodes pacificus to the shadow section of color LED light (LED 색광의 음영구역에 대한 살오징어의 행동반응 및 LED 집어등의 어획성능)

  • An, Young-Il;Jeong, Hak-Geun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.47 no.3
    • /
    • pp.183-193
    • /
    • 2011
  • This study made a comparative analysis of behavioral reaction of squid to red (624nm), green (524nm), blue (460nm) & white LED light, its arrival time for the shadow section by making the shadow section in the central section of a water tank just like the bottom part of a squid jigging vessel, and on-site catching efficiency of LED fishing lamp with control fishing vessel. The color LED light showing the highest squidgathering rate as against the shadow section was found to be blue LED light with 39.3% rate under the dark (0.05lx) condition. Under the brighter condition than 0.05lx, white LED light was found to have the highest gathering rate of 41.5%. In addition, it was found that squid gathering rate was high at the shadow section which showed 6.3-fold brightness difference between the shadow section and bright section. As for the arrival time for the shadow section, blue LED light was found to be the fastest in attracting squids in 192.7 seconds under the dark condition while the red LED light was the fastest in luring squids in 164.6 seconds under the bright condition. The ratio of the squid-jigging operation and sailing in fuel consumption of the fishing vessel loaded with LED fishing lamp is about 7 to 1, showing most of the fuel is consumed more in sailing than in squid-jigging operation. As for a catch of squid, the control vessel loaded with MH (Metal Halide) fishing lamp had more catch of 600-7,080 squids than the vessel loaded with LED fishing lamp having a catch of 260-1,700 squids. In addition, even in the comparison of a catch per automatic jigging machine, the catch of the vessel loaded with MH fishing lamp excelled that of the vessel loaded with LED fishing lamp in 6 operations of squid jigging out of 9 operations. The ratio of hand-jigging and automatic jigging machine (one line) in the LED fishing lamp vessel was 1:1.1 excepting the case of having a catch only using an automatic jigging machine, showing almost the same with each other in catches, while in case of a MH fishing lamp vessel, its ratio against hand-jigging was 1 to 5.8, showing hand-jigging excelled in catches.

Fishing efficiency of high capacity (360W) LED fishing lamp for squid Todarodes pacificus (대용량 (360W급) LED 집어등의 오징어 어획성능)

  • An, Young-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.3
    • /
    • pp.326-333
    • /
    • 2014
  • This study was conducted to investigate the fishing efficiency of an improved LED fishing lamp for squids. A total of 31 fishing operations were carried out with six-crew commercial fishing vessel Haengbok-Ho (24 tons) on which 43.2kW LED was installed, along with 14 automatic jigging machines, from October 6 to November 16, 2012. The 19 fishing vessels with Haengbok-Ho were compared with a control subject was 24 tons or 29 tons. A total illuminating power of metal halide (MH) fishing lamps in the control fishing vessel was either 84kW or 120kW. The number of automatic jigging machines in the control vessels was 8-18 and the number of crews engaged for fishing operation was 3-13. Average fuel consumption of LED fishing vessels during fishing operation was 505.1l which led to an average fuel consumption of 42.7l per hour. LED fishing vessel and MH fishing vessel caught on an average 1,946 squids and 2,439 squids, respectively, during the study period. Crews (hand line and hand reel) caught about 2.2 times the automatic jigging machines for LED fishing vessel and about 2.1 times for MH fishing vessel. Meanwhile, catches by the fishing vessels with LED in the combined total number per one line of automatic jigging machine and per crew were 86.6% of that of the control fishing vessel with MH. Also, fishing vessels with LED per automatic jigging machine achieved 71.8% of catches of that with MH fishing lamp. The catches of squids per the fishing vessel with 1W LED fishing lamp were higher by more than 135.5% of that in the fishing vessel with MH, which showed a good fishing performance even with only the use of a LED fishing lamp.

Vehicle Emergency Lamp Fuzzy Control Systems Using The GPS (GPS를 이용한 자동차 비상등 작동 장치)

  • Kwon, Yunjung;Nam, Sangyep
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.6
    • /
    • pp.276-281
    • /
    • 2014
  • Necessities of a traffic means work a car in the modern society human to an usability of a life is enjoying. On the other hand, the damage by traffic accident increment the human quotient worked as we were in proportion to the vehicle which increased. Passing an examination moves necessarily on an obstacle to suddenly appear at the fronts if a car travels and the vehicles which stopped suddenly. Dynamic passing an examination about an obstacle turn on Vehicle Emergency Lamp to by hand when is unhurried, and can turn off, but to appear urgently dynamic passing an examination in time human is instinctive, but cannot inform an emergency to a back vehicle, and a rear-end collision occurs. A car we synthesize a speed of a vehicle, and this unit analyzes as we use GPS, and to drive runs Vehicle Emergency Lamp to automatic in the situations that shall turn on emergencies etc. If a speed of a vehicle continuously slows down in too high-speed driving or low-speed driving, or we are stopped, Vehicle Emergency Lamp is always turned on. It was built if we rise again as clearing itself from risk, and a speed of a vehicle judges, and we turn off Vehicle Emergency Lamp to automatic. It runs till rear-end collision sensor operates, and by hand reset does Vehicle Emergency Lamp a driving vehicle collides from behind to a back vehicle or when a driving vehicle was overthrown. It is shortened very much to the chain rear-end collision traffic accident that is a traffic accident of large size if we use this unit. And we did authentication through the experiment which a driver was helpful to unnecessary operation and a relaxed safe driving during drivings.

The Thermal and Circuits Design of an LED Bulb Considering Temperature Property (온도 특성을 고려한 LED 전구의 방열 및 회로 설계)

  • Song, Sang-Bin;Yeo, In-Seon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1261-1267
    • /
    • 2007
  • Although LEDs have been used in various applications with improving the brightness and luminous efficacy, the electrical and optical characteristics of high power LED varies at different temperature and starting time. In this paper, optimal heat sink and apparatus design were conducted using IR camera and ICEPAK on the LED bulb consisting with fourteen LED array. The temperatures of heat sink and LED device of the designed LED bulb without cooling pan were $74^{\circ}C\;and\;96.8^{\circ}C$, respectively, showing in good themal characteristics. For high efficiency driving circuit of LED array adopted optimal heat sink design, driving circuits of constant voltage and current circuits were suggested and fabricated. As a result the efficacy of all driving circuits showed more than 20 lm/W. Also, the constant current circuits are suitable for signal lamp, hallway lamp, and flash lamp having short operating time(about 30 min). On the other hand, a reading light and indoor lamp having long operating time can be controlled by constant voltage circuit.

Development of a Reverse Transcription Loop-Mediated Isothermal Amplification Assay for Detecting Nervous Necrosis Virus in Olive Flounder Paralichthys olivaceus

  • Suebsing, Rungkarn;Oh, Myung-Joo;Kim, Jeong-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.7
    • /
    • pp.1021-1028
    • /
    • 2012
  • In this study, a reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for the rapid, sensitive, and inexpensive detection of nervous necrosis virus (NNV) in olive flounder, Paralichthys olivaceus, in Korea. A set of six specific primers was designed to target the RNA 2 gene encoding the coat protein of Korean NNV strains. The RT-LAMP reaction successfully detected NNV after 30 min at $65^{\circ}C$. When the sensitivities among RT-LAMP, RT-PCR, and nested RTPCR were compared, the RT-LAMP was shown to be able to detect the RNA template at $2.58{\times}10^{-2}\;TCID_{50}/ml$, whereas the RT-PCR and nested RT-PCR were only able to detect the RNA template at $2.58{\times}10^2\;TCID_{50}/ml$ and $2.58TCID_{50}/ml$, respectively. Thus, the sensitivity of the RT-LAMP assay was higher than those of the RT-PCR assays. In the specificity test of the RT-LAMP, 2 genotypes of NNVs (SJNNV and RGNNV) were positive; however, no other fish viruses were positive with the primers, indicating that the RT-LAMP assay is only specific to NNV. A total of 102 olive flounder were collected from hatcheries between 2009 and 2011. The occurrence of NNV in olive flounder was determined to be 53.9% (55/102) by the RT-LAMP. On the other hand, the prevalence based on the nested RT-PCR and RT-PCR results was 33.8% (34/102) and 20.6% (21/102), respectively. This result indicates that the RT-LAMP assay developed in this study is suitable for early field diagnosis of NNV with high sensitivity.