• 제목/요약/키워드: half-dose

검색결과 538건 처리시간 0.026초

Radioiodine internal dose coefficients specific for Koreans

  • Tae-Eun Kwon;Yoonsun Chung;Choonsik Lee
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2732-2739
    • /
    • 2024
  • This study developed internal dose coefficients for radioiodine, tailored to the Korean population, by incorporating the Korean biokinetic model along with the Korean S values. The observed differences in dose coefficients for Koreans compared to the International Commission on Radiological Protection (ICRP) reference values noticeably varied depending on physical half-lives of iodine isotopes. For longer-lived isotopes such as I-125 and I-129, significant differences in thyroid dose coefficients were observed, with ratios (Korean/ICRP) from 0.30 to 0.55, indicating that actual doses for Koreans can be considerably lower than those evaluated based on the ICRP data. However, for short-lived iodine isotopes, such as I-131, the thyroid dose coefficients were comparable to the ICRP reference values (ratio = 0.95-0.98). These comparable dose coefficients resulted from the lower thyroidal iodine uptake in the Korean model being almost entirely offset by the higher thyroid self-absorption S values in the Korean phantoms. Additionally, this study delves into the substantial differences in absorbed dose coefficients for non-thyroidal regions and effective dose coefficients, which arose not only from physiological/anatomical variability but also technical differences in phantom design. The use of Korean-specific dose coefficients is advisable particularly in scenarios predicting elevated doses, yielding a more precise and clinically relevant dose assessment.

아테놀올의 체내동태에 대한 신장해의 영향 (Effect of Renal Failure on Pharmacokinetics of Atenolol in Rabbits)

  • 이종기;조삼상
    • 한국임상약학회지
    • /
    • 제8권1호
    • /
    • pp.23-28
    • /
    • 1998
  • The pharmacokinetics of atenolol (25 mg/kg, i.v.) in the folate-induced renal failure rabbits was studied. Renal failure was induced by the i.v. injection of folate (50, 100, and 200 mg/kg). At folate dose of 100 and 200 mg/kg, the serum creatinine concentration (Scr) and blood urea nitrogen (BUN) increased significantly compared with control rabbits. Plasma concentrations and AUC of atenolol increased significantly at folate dose of 100 and 200 mg/kg. The elimination rate constant $(K_{el})$ and total body clearance $(CL_t)$ of atenolol decreased significantly, and half-life ($t_{1/2}$) and mean residence time (MRT) of atenolol increased significantly at folate dose of 100 and 200 mg/kg. The serum creatinine concentration $(S_{cr})$ correlated well (p<0.05) with half-life $(t_{1/2})$ and elimination rate constant $(K_{el})$ of atenolol, as well as BUN with AUC and total body clearance $(CL_t)$ of atenolol.

  • PDF

Change in radiation characteristics outside the SNF storage container as an indicator of fuel rod cladding destruction

  • Rudychev, V.G.;Azarenkov, N.A.;Girka, I.O.;Rudychev, Y.V.
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3704-3710
    • /
    • 2021
  • The characteristics of the external radiation on the surface of the casks for spent nuclear fuel (SNF) storage by dry method are investigated for the case when the spatial distribution of SNF in the basket changes due to the destruction of the fuel rod claddings. The surface areas are determined, where the changes in fluxes of neutrons, produced by 244Cm actinide, and γ-quanta, produced by long-lived isotopes, are maximum in the result of the decrease in the height of the SNF area. Concrete (VSC-24) and metal (SC-21) casks are considered as examples. The procedure of periodic measurement of the dose rate of neutrons or γ-quanta at the specified points of the cask surface is proposed for identifying the fuel rod cladding destruction. Under normal operation, the decrease in the dose rate produced by neutrons as the function of SNF storage duration is determined by the half-life of 244Cm, and for γ-quanta - by the half-lives of long-lived SNF isotopes. Consequently, a stepwise change in the dose rate of neutrons or γ-quanta, detected by the measurements, as compared to the previous one, would indicate the destruction of the fuel rod claddings.

디지털 방사선 시스템(DR)의 자동노출제어장치 이용 시 이온 챔버의 성능 평가를 위한 엔트로피 분석법의 유용성과 최적의 챔버 조합 모델 구현 연구 (Study on Usefulness of Entrance Surface Dose (ESD), Entropy Analysis Method to Evaluate Ionization Chamber Performance and Implementation of Optimal Chamber Combination Model when using Automatic Exposure Control (AEC) Device in Digital Radiography (DR))

  • 황준호;최지안;이경배
    • 한국방사선학회논문지
    • /
    • 제14권4호
    • /
    • pp.375-383
    • /
    • 2020
  • 본 연구는 자동노출제어장치 사용 시 이온 챔버의 성능과 조합에서 비롯된 문제를 정량적으로 분석하는 방법론을 제시하고 디지털 방사선 시스템의 성능을 최적화하고자 하였다. 실험방법은 복부와 골반부 검사에 사용된 파라미터의 X선질을 백분율 평균오차(PAE; Percentage Average Error)와 반가층(HVL; Half Value Layer)으로 평가하였다. 그 후 세 가지 이온 챔버를 조합했을 때의 입사표면선량(ESD; Entrance Surface Dose)과 엔트로피(Entropy)를 산출하여 방사선 출력의 안정성과 영상 품질을 분석하였다. 그 결과 실험에 사용한 디지털 방사선 시스템의 X선질은 모두 정상 범위의 백분율 평균오차와 반가층을 보였다. 입사표면선량은 챔버의 조합에 비례하여 증가하였고, 엔트로피는 세 개의 챔버가 조합됐을 때를 제외하고는 이온 챔버의 조합에 비례하여 증가하였다. 결론적으로 입사표면선량과 엔트로피를 이용한 분석은 이온 챔버의 성능과 조합의 문제를 평가하는데 유용한 방법인 것을 알 수 있었으며, 두 개 이하의 이온 챔버를 조합했을 때 디지털 방사선 시스템의 성능을 최적으로 유지할 수 있음을 알 수 있었다.

Irregular Surface Compensator (ISC)를 이용한 유방암치료계획에 관한 고찰 (Consideration Regarding the Breast Cancer Treatment Plan That Used Irregular Surface Compensator (ISC))

  • 제영완;김찬용;박흥득
    • 대한방사선치료학회지
    • /
    • 제19권2호
    • /
    • pp.131-141
    • /
    • 2007
  • 목 적: Irregular Surface Compensator (ISC)를 이용한 유방암의 방사선치료 계획과 쐐기필터를 이용한 치료계획의 선량분포 및 폐야의 선량을 비교, 평가 하고자 한다. 대상 및 방법: 수술 후 조직결손이 있는 유방암 환자를 대상으로 쐐기필터를 이용한 접선조사와 ISC를 이용한 접선조사로 처방선량(5,040 cGy)의 95%가 유방조직에 분포하도록 Varian (미국)사의 Eclipse (RTP)로 치료계획을 수립하여, 고선량영역과 선량체적분포도를 비교하고, 구형아크릴팬텀에 film을 이용하여 치료계획검증을 실시하였다. 결 과: 쐐기필터를 이용한 접선조사의 경우 치료부위 내에서 최대선량점 107.5%와 20 Gy의 선량이 폐의 체적에 7.63%가 조사되며, ISC의 경우 치료부위 내에서 최대선량점 106.4%와 폐의 체적 6.5%에 20 Gy 조사되도록 설계되었다. 팬텀을 이용한 필름 측정결과 개조사야와 쐐기필터를 이용한 경우 105$\sim$110%의 고선량 지역이 팬텀의 상부에 바나나 모양과 양쪽 가장자리에 각각 분포 하였으며 ISC의 경우 100$\sim$105%의 고른 선량 분포로 나타났다. 결 론: 쐐기필터를 보상체로 이용할 경우 선량계산 단면의 선량분포 조절은 가능하였으나 그 외 다른 치료부위의 입체적 조절이 불가능하여 선량분포를 개선 할 수 없었고 ISC는 선량의 입체적 조절이 가능하여 피부 표면이 불균등한 치료부위의 선량 보정과 심부 정상조직의 선량감소 등의 이점이 있어 유방이외 조직결손이 많은 수술부위 치료 등에도 활용이 가능할 것으로 사료된다.

  • PDF

진단방사선 영역에서 피폭선량 감소를 위한 기술적 연구 - 관전압과 부가여과판을 중심으로 - (A Study for Reduction of Radiation Dose in the Field of Diagnostic Radiology - A Point of Tube Voltage and Filtration -)

  • 하호영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제15권1호
    • /
    • pp.89-97
    • /
    • 1992
  • X-ray quality is identified numerically by half value layer(H.V.L) and the HVL is affected by the kVp and the amount of filtration in the useful beam. X-ray quality evaluated by H.L.D is influenced by kVp and filtration. Author had several experiments with phantom in diameter of 8 cm normal adult chest, for reduction of radiation dose of the patients in diagnostic radiology and got some results. 1. H.V.L is increased the thicker the filter and the higher the kVp. 2. If the kVp is increased from 60 to 120, the skin dose can be reduced as 34%(Skin dose of 60 kVp with 4 mmAl filter : 100%). 3. If the 4 mmAl filter with 60 kVp is added to x-ray tube, skin dose can be reduced as 23% than no filter. 4. Therefore high kVp and filtration can increase output to input dose ratio and 120 kVp and 4 mmAl filter were most effective for reduction of patient dose in chest radiography.

  • PDF

Dosimetry Check™를 이용한 MVCT 선량계산 모델 구축에 관한 연구 (A Study on the Construction of MVCT Dose Calculation Model by Using Dosimetry Check™)

  • 엄기천;김창환;전수동;백금문
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권6호
    • /
    • pp.431-441
    • /
    • 2020
  • The purpose of this study was to construct a model of MVCT(Megavoltage Computed Tomography) dose calculation by using Dosimetry Check™, a program that radiation treatment dose verification, and establish a protocol that can be accumulated to the radiation treatment dose distribution. We acquired sinogram of MVCT after air scan in Fine, Normal, Coarse mode. Dosimetry Check™(DC) program can analyze only DICOM(Digital Imaging Communications in Medicine) format, however acquired sinogram is dat format. Thus, we made MVCT RC-DICOM format by using acquired sinogram. In addition, we made MVCT RP-DICOM by using principle of generating MLC(Multi-leaf Collimator) control points at half location of pitch in treatment RP-DICOM. The MVCT imaging dose in fine mode was measured by using ionization chamber, and normalized to the MVCT dose calculation model, the MVCT imaging dose of Normal, Coarse mode was calculated by using DC program. As a results, 2.08 cGy was measured by using ionization chamber in Fine mode and normalized based on the measured dose in DC program. After normalization, the result of MVCT dose calculation in Normal, Coarse mode, each mode was calculated 0.957, 0.621 cGy. Finally, the dose resulting from the process for acquisition of MVCT can be accumulated to the treatment dose distribution for dose evaluation. It is believed that this could be contribute clinically to a more realistic dose evaluation. From now on, it is considered that it will be able to provide more accurate and realistic dose information in radiation therapy planning evaluation by using Tomotherapy.

흉부 전산화 단층 촬영 검사 시 발생하는 생식선 차폐 유무에 따른 산란 선량 차이에 관한 연구 (A Study on the Difference of Scattered Rays with or Without Gonadal Shielding During Chest Computed Tomography)

  • 곽종혁;김경립;성현철;김승원;송근성;최민경;이상원
    • 한국방사선학회논문지
    • /
    • 제15권2호
    • /
    • pp.109-115
    • /
    • 2021
  • 생식선 차폐를 하지 않았을 때 전부, 양 측부, 후부, 생식선 부위의 산란선을 측정하고 Xenolite nolead Apron(0.35 mm Pb), Xenolite nolead Apron(front 0.35 mm Pb Mix back 0.25 mm Pb, Skirt overlap), Half Apron(0.5 mm Pb)로 차폐 후 각각의 산란 선량을 측정하였다. 흉부 전산화 단층촬영 검사 시 검사 부위의 산란 선량은 272 μSv가 측정되었고, Apron으로 차폐하지 않았을 시에 평균 전부 43 μSv, 좌측부 81 μSv, 우측부 82μSv, 후부 38.8 μSv, Gonad 부위 16 μSv로 측정되었다. Xenolite nolead Apron으로 위쪽 부분만 차폐하고 측정했을 전부 11.2 μSv, 좌측부 43.1 μSv, 우측부 45.3 μSv, 후부 12 μSv, Gonad 부위 5.2 μSv로 측정되었다. Xenolite nolead Apron(Skirt overlap)으로 Pelvis 부위를 360° 감싼 후 선량을 측정하였을 때 전부 5.6 μSv, 좌측부 22.4 μSv, 우측부 15.7 μSv, 후부 6 μSv, Gonad 부위 3.2 μSv로 측정되었다. Xenolite nolead Apron(Skirt overlap)으로 Pelvis 부위를 360° 감싼 후 선량을 측정하였을 때 전부 5.6 μSv, 좌측부 22.4 μSv, 우측부 15.7μSv, 후부 6 μSv, Gonad 위 3.2 μSv로 측정되었다. Half Apron으로 위쪽만 차폐하고 측정했을 때에는 전부 10.7 μSv, 좌측부 42.6 μSv, 우측부 40.6 μSv, 후부 11.3 μSv, Gonad부위 4.7 μSv로 측정되었다. 골반 부위를 360° 차폐하는 방법이 80% 이상 선량 감소를 보였고, 전부 차폐 시 70% 이상의 선량 감소 효과를 보였으며 모든 전산화 단층 촬영 검사에 있어 피폭선량 경감을 위한 연구와 차폐 가능한 장비를 활용하는 다양한 기법에 관한 지속적인 연구가 필요하리라 사료된다.

Radiation Measurements at Fukushima Medical University over a Period of 12 Years Following the Nuclear Power Plant Accident

  • Ryo Ozawa
    • Journal of Radiation Protection and Research
    • /
    • 제48권3호
    • /
    • pp.153-161
    • /
    • 2023
  • Background: Fukushima Medical University (FMU) is located 57 km northwest of the Fukushima Daiichi Nuclear Power Plant. Our laboratory has been conducting environmental radiation measurements continuously before and after the nuclear accident. We aimed to report the observed behavior of radiation originating from the released radioactive materials due to the accident, predict future trends, and disseminate the results to the local residents. Materials and Methods: Measurements of the counting rate by a diameter of 76 mm and a length of 76 mm thallium-doped sodium iodide (NaI[Tl]) scintillation detector (S-1211-T; Teledyne Brown Engineering Environmental Services) in the central part of the laboratory, and the dose rate outward at the window by NaI(Tl) scintillation detector and digital processor (EMF211; EMF Japan Co. Ltd.) were conducted. Results and Discussion: Measurements by Teledyne S-1211-T showed that in the early stages, radiation from radioactive isotopes with short half-lives was dominant, while radiation from radioactive isotopes with longer half-lives became dominant as the measurement period became longer. Through nonlinear least squares regression, both short and long half-lives were successfully determined. It was also possible to predict how the radiation dose would decrease. The environmental radiation trends around FMU were measured by the EMF211. Both measurements were affected by rainfall and snow accumulation. Decontamination work on the FMU campus impacted measurements by the EMF211 especially. Conclusion: The results of two types of measurements, one at the center and the other at the window side of the laboratory, were presented. By applying a simplified model, radiation from radioactive isotopes with short and long half-lives was identified. Based on these results, future trends were predicted, and the information was used for public communication with the local residents.

EBT-3 필름을 사용한 감마나이프 퍼펙션TM의 치료 계획 시스템 및 선량 분포 비교 분석 (Comparative Analysis of Treatment Planning System and Dose Distribution of Gamma knife PerfexionTM using EBT-3 Film)

  • 진성진;김성진;서원섭;허병익
    • 한국방사선학회논문지
    • /
    • 제11권6호
    • /
    • pp.509-515
    • /
    • 2017
  • 본 연구는 EBT3 필름을 이용하여 감마나이프 퍼펙션 모델의 3차원적인 선량분포 측정하고 기준값과 비교 분석하여 표준화된 측정방법의 기초로 활용하고자 한다. 2개 종합병원에 설치된 감마나이프 퍼펙션 모델의 선량 분포를 EBT3 필름을 이용하여 정확도와 정밀도를 평가하였다. 정확도 평가를 위해 4 mm 콜리메터를 사용하여 기계적인 중심축과 선량중심축의 일치도를 측정하였다. A병원 0.098 mm, 0.195 mm 이며 B 병원 0.229 mm, 0.223 mm 로 허용 오차 0.3 mm 이하로 측정되었다. 정밀도 평가는 4, 8, 16 mm 콜리메터(collimater) 각각의 x, y, z 3차원면 에서의 반치폭(FWHM : Full Width at Half Maximum)을 이미지-제이 프로그램을 이용하여 평가하였다. A 병원은 -0.283~0.583 mm, B 병원은 -0.857~0.810 mm로 50%선 ${\pm}1mm$ 이하의 기준에 적합하였다. 이미지-제이 프로그램을 이용한 선량 분포 분석의 경우 측정자 간의 오차가 발생 가능함으로 측정점에 대한 명확한 기준을 확립할 필요가 있으며, 감마나이프 방사선 수술이 시행되어지는 고선량 영역에서 사용 가능한 선량영역이 높은 필름을 이용한 치료계획과 실제 치료 조사면의 비교가 필요하다고 생각된다.