• 제목/요약/키워드: half beam

검색결과 392건 처리시간 0.019초

석조유구(石造遺構)를 통한 한국(韓國) 고대건축(古代建築)에 관한 연구(硏究) -삼국시대와 통일신라시대를 중심으로- (A Study on the Ancient Architecture in view of the Stone Remains (focused on the 3 Kingdom Period and Unificated Shilla Period))

  • 천득염;박지민
    • 건축역사연구
    • /
    • 제8권3호
    • /
    • pp.23-38
    • /
    • 1999
  • The purpose of this study is to analogize the appearance of Korean Ancient Architecture in view of the Stone Remains from 3 Kingdom Period to Unificated Shilla Period. But in these period, there is no building remains but some stupas and fine arts. Especially, there are many architectural appearance and revealing signature in these Historical Stone remains. Architectural elements which are analogized by stone remains what has value as historical materials by preservation of original form from 3 Kingdom Preiod to Unificated Shilla Period are as follows : 1) Platform, the representative characteristic of Korean traditional architecture, was frame structure and accumulate structure. And circular or square footing stood a same shape column on it is put on the platform. 2) In the case of column, there used entasis column and inclined column and circular chamfer technique was applied on the top side of it. Upper side of column, capital and head pentrating tie that small bearing block was put on the center of it was joined. And longitu야nal rest(長舌) supported a cross beam. Capital and small bearing block had no bottom heel, and heel side was curved and straight. Centered bracket structure was often used, and multi bracket structure is not used yet. Inward incline technique was used. 3) Inward opening pair door which had lintel, threshold, doorjamb was usually used, Fixing stone was used for structural safety, and circular handle and lock was used for decoration. Handrail was used on the edge of wooden floor for decorative effect and safety. 4) Square rafter and circular rafter were used in the same period and so did flying rafter. Double eaves and single eave were used in the same period but, single eave was usually used. In this period, square rafter was usually used. This would be studied more by comparing with Japanese wooden architecture. 5) Hipped roof was used and half-hipped roof was not used yet. In front of th hip, there are small sculpture called Jap-Sang(雜像), and windbell was hang on the end of the hip rafter. Concave roof tile, convex roof tile, round eaver tile, decorative tile at end of roof ridge were used. Lotus style was well used on the face of roof tile for decoration. From the results of this study, wooden architecture of Unificated Shilla period was simple compare to Koryo dynasty and Chosun dynasty but, it had some brilliant character. It was hard work that analogized the form of non-existent wood architecture of Ancient Korean period by restricted stone remains. But, in addition to the results of this study and research of old documentations, more study should be go on.

  • PDF

변형된 Sierpinski 프랙탈 구조를 갖는 이중 대역 배열 안테나 (Dual-Band Array Antenna Using Modified Sierpinski Fractal Structure)

  • 오경현;김병철;정치현;김건우;이득영;추호성;박익모
    • 한국전자파학회논문지
    • /
    • 제21권9호
    • /
    • pp.921-932
    • /
    • 2010
  • 본 논문에서는 Sierpinski 프랙탈 구조를 이용하여 이중 대역에서 동작하는 배열 안테나를 제안하였다. 거울 대칭 형태의 $2{\times}2$ 배열 구조는 상부 $1{\times}2$ 배열과 하부 $1{\times}2$ 배열 간에 $180^{\circ}$ 위상차를 인가하면 cellular 대역과 WCDMA 대역에서 broadside 방향으로 복사 패턴을 형성한다. 따라서, 동위상 급전 회로를 적용하기 위해 배열 구조에서 상부와 하부 배열 간에 패치와 그라운드의 위치를 변경하여 위상 반전 구조를 구현하였다. 배열 안테나는 $28{\times}30{\times}5\;cm^3$의 크기를 가지며, -10 dB 반사 손실 대역은 1차 대역에서 855~1,380 MHz(47 %), 2차 대역에서 1,770~2,330 MHz(27 %)이다. 이득은 1차 대역에서 9.06~12.44 dBi, 2차 대역에서 11.76~14.84 dBi이다. 1,100 MHz에서 x-z 평면의 반전력 빔 폭은 $57^{\circ}$, y-z 평면의 반전력 빔 폭은 $46^{\circ}$이고, 2,050 MHz에서는 각각 $43^{\circ}$$28^{\circ}$이다.

고해상도 엑스선 광전자 분광법을 이용한 다결정구조의 안티몬-테레니움 박막 연구 (High-Resolution X-Ray Photoelectron Spectroscopy Study of a Sb2Te3 Thin Film with the Polycrystalline Phase)

  • 이영미;김기홍;신현준;정민철;취야빙
    • 한국진공학회지
    • /
    • 제21권6호
    • /
    • pp.348-353
    • /
    • 2012
  • 스퍼터를 이용하여 실리콘 기판위에 제작된 안티몬-테레니움 다결정 박막을 방사광을 이용한 고해상도 엑스선 광전자 분광법 실험을 수행하여 화학적 상태를 분석하였다. 엑스선 회절 실험을 통해 제작된 안티몬-테레니움 박막은 롬보헤드럴 구조를 가지는 다결정임을 확인하였다. 엑스선 광전자분광법을 수행하기 위하여 표면의 산화막 제거를 위해 저에너지 네온 이온 스퍼터링을 빔에너지 1 kV로 1 시간동안 수행하였고, 이를 통해 표면 산화막이 완벽히 제거됨을 확인하였다. 또한, 스퍼처링에 의하여 표면 비정질화된 상태를 결정화 상태로 만들기 위해 상변화온도인 $100^{\circ}C$에서 5 분간 초고진공상태에서 열처리를 수행하였다. 이후 획득되어진 테레니움 4d와 안티몬 4d 속전자레벨 분석에서 각각의 묶음에너지가 40.4 그리고 33.0 전자볼트임을 확인할 수 있었으며, 각각은 단일한 화학적 상태를 나타내고 얻어진 피크의 밀도분석을 통해 화학적조성비가 2 : 3임을 확인하였다.

Water Phantom 속 Conventional X-ray 중심축상의 깊이 선량 백분율 (Central Axis Percentage Depth-Dose in a Water Phantom Irradiated by Conventional X-rays)

  • 김원식;하석호;황선태;오장진;전재식
    • Journal of Radiation Protection and Research
    • /
    • 제12권1호
    • /
    • pp.1-11
    • /
    • 1987
  • X-선 target 으로 부터 water phantom($30{\times}30{\times}30cm^3$) 표면까지 1m이고 이 지점에서 비임 크기가 $5cm{\phi},\;10cm{\phi},\;15cm{\phi}$인 경우 phantom 표면으로 부터 X-선 중심축을 따라 깊이 2.5cm의 기준점으로 부터깊이 20cm까지 2.5cm 간격으로 깊이-선량 백분율, P(%)을 추정하였다. 사용된 X-선 인가전압 및 전류는 $150{\sim}250kV$ 및 5 mA 이었고 물속 흡수선량률, $\dot{D}_w$은 NE 2571 공동전리함의 조사선량 교정인자 $N_x$로부터 구한 공기 kerma 고정인자 $N_k$를 이용하여 결정하였다. 기준조사선량룰 $\dot{X}_c$은 Exradin A-2공동 전리함을 일본 ETL로부터 교정하여 X-선 선질을 ETL 교정선질과 같도록 반가층을 결정한 후에 측정되었다. 한편, 흡수선량 및 깊이-선량 백분율 측정의 정확도를 검증하기 위해 phantom 속 깊이 5 cm되는 교정점에서 물속흡수선량률, $\dot{D}_w$$N_k$로부터 산출한 값과 Burlin의 일반화된 공동이론을 이용하여 계산한 값을 비교해 보았으며, $N_k$로부터 결정된 깊이-선량 백분율 P(%)을 BJR Suppl. 로부터 구한 값과 비교해 본 결과는 좋은 일치를 보였다.

  • PDF

반복률과 라만매질 압력에 따른 1.54 ${\mu}m$ 전방, 후방 유도라만 및 1.06${\mu}m$ Brillouin 산란광의 출력특성 (Stimulated Raman scattering at 1.54${\mu}m$ and Brillouin scattering at 1.06${\mu}m$ in $CH_4$ under 5 Hz repetition rate)

  • 최영수;전용근;김재기
    • 한국광학회지
    • /
    • 제10권2호
    • /
    • pp.95-101
    • /
    • 1999
  • 1.06$\mu\textrm{m}$ Nd:YAG 펌프레이저의 반복률 5 Hz 이하에서 라만매질 $CH_4$ 의 압력변화에 따른 전방, 후방 1.54 $\mu\textrm{m}$ 유도라만 산란광 및 후방 1.06 $\mu\textrm{m}$ 유도 Brillouin 산란광의 출력특성을 분석하였다. 전방보다 후방 유도라만 산란광이 더 효율적이고, 후방 유도 Brillouin 산란광보다 전방과 후방 유도라만 산란광의 변환효율이 높게 나타났다. 이는 유도라만 산란광의 생성조건이 정상상태이나 Brillouin 산란광은 transient 상태이기 때문이다. 매질 $CH_4$가 순환되지 않을 때, 반복률 5 Hz에서 후방 유도라만 산란광과 Brillouin 산란광의 출력에너지는 라만매질의 열발생으로 모두 약47% 감소하였다. 그러나, 후방에 의한 펌프광의 소모가 감소하여 전방 유도라만 산란광은 오히려 8.5% 증가하였다. 이는 반복률에 따른 열발생이 후방 산란광 생성영역에서 강하게 발생함을 의미한다. 또, 메니스커스형 이색성 집속렌즈를 사용하여 인가에너지 40 mJ에서 유도라만 산란광은 37% 이상의 변환효율을 보였다.

  • PDF

도파관 슬롯 배열 안테나용 리지가 장하된 끝이 둥근 소형 슬롯 (Ridge-Loaded Small Round-Ended Slot for Waveguide Slot-Array Antenna)

  • 김병문;이종익;조영기
    • 한국전자파학회논문지
    • /
    • 제23권8호
    • /
    • pp.950-957
    • /
    • 2012
  • 본 논문에서는 도파관 슬롯 배열 안테나의 요소로서 구형 도파관 광벽에 위치하고 이중 리지가 장하된 끝이 둥근 소형 슬롯을 제안하였다. 리지 치수를 적절히 조절하면 원하는 주파수에서 슬롯의 공진을 얻을 수 있다. 제안된 슬롯의 공진 길이는 공진 주파수에서 약 $0.26{\lambda}_0$(자유 공간 파장)이다. 제안된 공진 슬롯은 소형이고, 작은 공진 컨덕턴스 그리고 짧으면서도 안정된 공진 길이 등의 장점을 가진다. 부가적으로 슬롯을 도파관 슬롯 배열에 적용할 때 각 슬롯의 특성들이 인접한 슬롯에 의해서 영향을 적게 받는다. 부엽 준위 -20 dB를 가지는 $4{\times}1$ 도파관 슬롯 배열 안테나를 설계, 제작한 후 실험하였다. 측정결과들이 시뮬레이션 결과들과 잘 일치하고, 주파수 9.41 GHz에서 부엽 준위 -15.9 dB, E-평면 반치각 $110.2^{\circ}$, H-평면 반치각 $21.2^{\circ}$이다.

Evaluation of the hybrid-dynamic conformal arc therapy technique for radiotherapy of lung cancer

  • Kim, Sung Joon;Lee, Jeong Won;Kang, Min Kyu;Kim, Jae-Chul;Lee, Jeong Eun;Park, Shin-Hyung;Kim, Mi Young;Lee, Seoung-Jun;Moon, Soo-Ho;Ko, Byoung-Soo
    • Radiation Oncology Journal
    • /
    • 제36권3호
    • /
    • pp.241-247
    • /
    • 2018
  • Purpose: A hybrid-dynamic conformal arc therapy (HDCAT) technique consisting of a single half-rotated dynamic conformal arc beam and static field-in-field beams in two directions was designed and evaluated in terms of dosimetric benefits for radiotherapy of lung cancer. Materials and Methods: This planning study was performed in 20 lung cancer cases treated with the VERO system (BrainLAB AG, Feldkirchen, Germany). Dosimetric parameters of HDCAT plans were compared with those of three-dimensional conformal radiotherapy (3D-CRT) plans in terms of target volume coverage, dose conformity, and sparing of organs at risk. Results: HDCAT showed better dose conformity compared with 3D-CRT (conformity index: 0.74 ± 0.06 vs. 0.62 ± 0.06, p < 0.001). HDCAT significantly reduced the lung volume receiving more than 20 Gy (V20: 21.4% ± 8.2% vs. 24.5% ± 8.8%, p < 0.001; V30: 14.2% ± 6.1% vs. 15.1% ± 6.4%, p = 0.02; V40: 8.8% ± 3.9% vs. 10.3% ± 4.5%, p < 0.001; and V50: 5.7% ± 2.7% vs. 7.1% ± 3.2%, p < 0.001), V40 and V50 of the heart (V40: 5.2 ± 3.9 Gy vs. 7.6 ± 5.5 Gy, p < 0.001; V50: 1.8 ± 1.6 Gy vs. 3.1 ± 2.8 Gy, p = 0.001), and the maximum spinal cord dose (34.8 ± 9.4 Gy vs. 42.5 ± 7.8 Gy, p < 0.001) compared with 3D-CRT. Conclusions: HDCAT could achieve highly conformal target coverage and reduce the doses to critical organs such as the lung, heart, and spinal cord compared to 3D-CRT for the treatment of lung cancer patients.

Synthesis of barium-doped PVC/Bi2WO6 composites for X-ray radiation shielding

  • Gholamzadeh, Leila;Sharghi, Hamed;Aminian, Mohsen Khajeh
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.318-325
    • /
    • 2022
  • In this study, composites containing undoped and barium-doped Bi2WO6:Ba2+were investigated for their shielding against diagnostic X-ray. At first, Bi2WO6 and barium-doped Bi2WO6 were synthesized with different weight percentages of barium oxide through a hydrothermal process. The as-synthesized nanostructures were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS) and Raman spectroscopy (RS). After that, some shields were generated with undoped and barium-doped Bi2WO6:Ba2+ nanostructure particles incorporated into polyvinyl chloride (PVC) polymer with different thicknesses and 15% weight of the nanostructure. Finally, the prepared samples were exposed to an X-ray tube at 40, 80, and 120 kV voltages, 10 mAs and, 44.5 cm SID (i.e. the distance from the X-ray beam source to the specimen). Linear and mass attenuation coefficients were also calculated for different samples. The results indicated that, among the samples, the one with 7.5 mmol barium-doped Bi2WO6 had the most attenuation at the voltage of 40kV, and the attenuation coefficients would increase with an increase in the amount of barium. The samples with 15 and 17.5 mmol barium-doped Bi2WO6 had higher attenuation than the others at 80 and 120 kV. Moreover, the half-value layer (HVL), tenth-value layer (TVL) and 0.25 mm lead equivalent thickness were calculated for all the samples. The lowest HVL value was for the sample with 7.5 mmol barium-doped Bi2WO6. As the result clearly show, an increment in the barium-doping content leads to a decrease in both HVL and TVL. In every three voltages, 0.25 mm lead equivalent thickness of the barium-doped composites (7.5 mmol and 15 mmol) had less than the other composites. The lowest value of 0.25 mm lead equivalent thickness was 7.5 barium-doped in 40 kV voltage and 15 mmol barium-doped in 80 kV and 120 kV voltages. These results were obtained only for 15% weight of the nanostructure.

Development of a polystyrene phantom for quality assurance of a Gamma Knife®

  • Yona Choi;Kook Jin Chun;Jungbae Bahng;Sang Hyoun Choi;Gyu Seok Cho;Tae Hoon Kim;Hye Jeong Yang;Yeong Chan Seo;Hyun-Tai Chung
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2935-2940
    • /
    • 2023
  • A polystyrene phantom was developed following the guidance of the International Atomic Energy Association (IAEA) for gamma knife (GK) quality assurance. Its performance was assessed by measuring the absorbed dose rate to water and dose distributions. The phantom was made of polystyrene, which has an electron density (1.0156) similar to that of water. The phantom included one outer phantom and four inner phantoms. Two inner phantoms held PTW T31010 and Exradin A16 ion chambers. One inner phantom held a film in the XY plane of the Leksell coordinate system, and another inner phantom held a film in the YZ or ZX planes. The absorbed dose rate to water and beam profiles of the machine-specific reference (msr) field, namely, the 16 mm collimator field of a GK PerfexionTM or IconTM, were measured at seven GK sites. The measured results were compared to those of an IAEA-recommended solid water (SW) phantom. The radius of the polystyrene phantom was determined to be 7.88 cm by converting the electron density of the plastic, considering a water depth of 8 g/cm2. The absorbed dose rates to water measured in both phantoms differed from the treatment planning program by less than 1.1%. Before msr correction, the PTW T31010 dose rates (PTW Freiberg GmbH, New York, NY, USA) in the polystyrene phantom were 0.70 (0.29)% higher on average than those in the SW phantom. The Exradin A16 (Standard Imaging, Middleton, WI, USA) dose rates were 0.76 (0.32)% higher in the polystyrene phantom. After msr correction factors were applied, there were no statistically significant differences in the A16 dose rates measured in the two phantoms; however, the T31010 dose rates were 0.72 (0.29)% higher in the polystyrene phantom. When the full widths at half maximum and penumbras of the msr field were compared, no significant differences between the two phantoms were observed, except for the penumbra in the Y-axis. However, the difference in the penumbra was smaller than variations among different sites. A polystyrene phantom developed for gamma knife dosimetry showed dosimetric performance comparable to that of a commercial SW phantom. In addition to its cost effectiveness, the polystyrene phantom removes air space around the detector. Additional simulations of the msr correction factors of the polystyrene phantom should be performed.

자궁경부암의 수술 후 방사선치료 (Adjuvant Postoperative Radiation Therapy for Carcinoma of the Uterine Cervix)

  • 이경자;문혜성;김승철;김종일;안정자
    • Radiation Oncology Journal
    • /
    • 제21권3호
    • /
    • pp.199-206
    • /
    • 2003
  • 목적: 자궁경부암에서 수술 후 위험인자가 있는 환자에 방사선치료 후 생존율, 국소 제어율과 예후인자를 후향적으로 분석하여 수술 후 방사선치료의 효과를 알고자 한다. 대상 및 방법: 1986년 3월부터 1998년 12월까지 자궁경부암 FIGO 병기 IB-IIB로 자궁적출술 후 방사선치료를 받은 58명을 대상으로 국소 제어율, 5년 무병생존율과 생존율에 미치는 예후인자를 후향적으로 분석하였다. 수술 후 방사선치료의 적응증은 병리학적으로 림프절에 전이된 경우, 암이 수술절제연이나, 자궁주위조직 혹은 자궁체부에 침범하였거나, 림프혈관강에 침범된 경우, 자궁기질의 1/2 이상 깊이 침윤된 경우와 단순 자궁적출술 후 암으로 진단받은 환자로 하였다. 수술 후 방사선치료는 모든 환자에서 골반강에 외부조사를 시행하였으며 5명은 외부조사와 강내조사를 병용하였다. 외부조사는 6 MV x-선을 이용하여 매일 180 cGy를 4문으로 조사하였으며 총 방사선량은 $4400\~5040$ cGy (중앙값: 5040 cGy)이었다. 강내조사는 외부조사 후 2주에 Cs-137를 이용하여 저선량률로 질 표면에서 5 mm 깊이에 $4488\~4932$ cGy (중앙값: 4500 cGy)를 시행하였다. 추적기간은 15개월에서 108개월로 중앙값은 44개월 이었다. 결과: 전체환자의 5년 무병생존율은 $94\%$, 국소 제어율은 $98\%$,이었으며 원격 전이율은 $5\%$이었다. 병기에 따른 5년 무병생존율은 $IB\;97.1\%,\;IIA\;100\%,\;IIB\;68.9\%$(p=0.0145)이었다. 질 절제연에 암의 침범이 없는 경우 5년 무병생존율이 $97.8\%$, 있는 경우 $60\%$, (P=0.0002)이었으며, 자궁주위조직에 암이 침범이 없는 경우의 5년 무병 생존율은 $97.8\%$이었고, 있는 경우는 $33.3\%$이었다(p=0.0001). 다변량 분석에 의하면 자궁주위조직의 침범만이 통계학적으로 의의있는 예후인자이었다. 치료 후 만성합병증은 3명($5\%$,)에서 RTOG grade 2의 방광염, 1명에서 grade 2의 직장염과 1명에서 하지에 림프부종이 나타났다. 결론: 조기 자궁경부암 환자에 단순 자궁적출술을 시행하였거나, 근치적 자궁적출술 후 병리학적으로 재발 위험 인자가 있는 환자에 수술 후 방사선치료를 시행하여 심각한 부작용 없이 비교적 높은 국소 제어율과 생존율을 얻을 수 있었다. 생존율에 영향을 미치는 예후인자는 병리학적으로 암이 자궁주위조직에 침범된 것으로 예후가 불량하였다. 수술 후 방사선치료의 실패원인과 예후인자를 분석한 본 후향적 연구결과를 토대로 앞으로 방사선치료와 항암화학요법을 병용하여 보다 적극적이고 전향적인 연구를 시도하는데 이정표로 이용할 수 있다고 생각한다.