• Title/Summary/Keyword: guided selection

Search Result 87, Processing Time 0.028 seconds

Interpretation of Image-Guided Biopsy Results and Assessment (영상유도하 조직검사의 해석과 판정)

  • Su Min Ha;Jung Min Chang
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.361-371
    • /
    • 2023
  • The success of image-guided breast biopsy depends on the biopsy method, needle selection, and appropriate technique based on the accurate judgment by the radiologist at biopsy. However, insufficient or inappropriate sampling of specimens may result in false-negative results or pathologic underestimation. Therefore, image-pathology concordance assessments after biopsy are essential for appropriate patient management. Particularly, the assessment of image-pathology concordance can avoid false-negative reports of breast cancer as a benign pathology. Therefore, this study aimed to discuss factors that impact the accurate interpretation of image-guided breast biopsy along with the appropriate assessments.

Identification of Guided-wave Modes for on-line monitering in the pipe weldment (배관 용접부의 상시감시를 위한 유도초음파 모드 규명)

  • Park Ik-Geun;Kim Tae-Hyeong;Lee Cheol-Gu;Kim Yong-Gwon;Park Tae-Seong;Lee Jin-Hyeok
    • Proceedings of the KWS Conference
    • /
    • 2006.05a
    • /
    • pp.307-309
    • /
    • 2006
  • For efficient NDE of pipes, essential components of power plant facilities, ultrasonic guided waves were generated and received applying an air-coupled transducer and comb one as non-contact technology, Mode generation and selection were predicted based on theoretical dispersive curve and the element spaceof a comb transducer. In addition, a receiving angle of the air-coupled transducer was determined to acquire the predicted modes by theoretical phase velocity of each mode. Theoretical dispersive curve was compared with the results of the time-frequency spectroscopes based on the wavelet transform and 2D-FFT to identify the characteristics of the received mode. The received modes show a good agreement with the predicted ones.

  • PDF

Development of an SH Wave Magnetostrictive Transducer Module for Guided Wave Testing of Plate Structures (판형 구조물 유도초음파 검사를 위한 SH파 자기변형 트랜스듀서 모듈 개발)

  • Cho, Seung-Hyun;Park, Jae-Ha;Kwon, Hyu-Sang;Ahn, Bong-Young;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.122-129
    • /
    • 2009
  • Recently much attention has been paid to a guided wave due to its effective applicability to long range and fast inspection of structures. In guided wave based NDE, the appropriate selection of wave modes is one of important factors since the test performance is highly dependent on which mode of guided waves is employed. As far as plate-like structures are concerned, so far, SH guided wave has not been frequently applied compared to Lamb waves, which is mostly caused by the lack of proper and convenient transducers to generate and measure the SH waves. In this investigation, a new small-sized SH guided wave transducer based on magnetostriction is proposed. The present transducer was designed to be modular and be used with shear couplant to avoid the inconvenience of the existing magnetostrictive patch transducers, which comprises the ferromagnetic patch tightly bonded to a structure. The wave transduction mechanism and the detailed configuration of the present transducer are presented. Experimental verification is also conducted on test specimens and the results confirm the good performance of the present transducer module.

Stereotactic Multiplanar Reformatted Computed Tomography-Guided Catheter Placement and Thrombolysis of Spontaneous Intracerebral Hematomas

  • Hwang, Jae-Ha;Han, Jong-Woo;Park, Kyung-Bum;Lee, Chul-Hee;Park, In-Sung;Jung, Jin-Myung
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.4
    • /
    • pp.185-189
    • /
    • 2008
  • Objective : The authors present their experiences with stereotactic multiplanar reformatted (MPR) computed tomography (CT)-guided catheter placement for thrombolysis of spontaneous intracerebral hematoma (sICH) and their clinical results. Methods : In 23 patients with sICH, MPR CT-guided catheter placement was used to select the trajectory and target point of hematoma drainage. This group was comprised of 11 men and 12 women, and the mean age was 57.5 years (range, 31-79 years). The patients' initial Glasgow Coma Scale scores ranged from 7 to 15 with a median of 11. The volume of the hematoma ranged from 24 mL to 86 mL (mean 44.5 mL). A trajectory along the main axis of the hematoma was considered to be optimal for thrombolytic therapy. The trajectory was calculated from the point of entry through the target point of the hematoma using reformatted images. Results : The hematoma catheter was left in place for a median duration of 48.9 hours (range 34 to 62 hours). In an average of two days, the average residual hematoma volume was 6.2 mL (range 1.4 mL to 10.2 mL) and was reduced by an average of 84.7% (range 71.6% to 96.3%). The residual hematoma at postoperative seven days was less than 5 mL in all patients. There was no treatment-related death during hospitalization. Conclusion : The present study indicates that stereotactic MPR CT-guided catheter placement for thrombolysis is an accurate and safe procedure. We suggest that this procedure for stereotactic removal of sICH should be considered for the optimization of the trajectory selection in the future.

Outcome and Cost Effectiveness of Ultrasonographically Guided Surgical Clip Placement for Tumor Localization in Patients undergoing Neo-adjuvant Chemotherapy for Breast Cancer

  • Masroor, Imrana;Zeeshan, Sana;Afzal, Shaista;Sufian, Saira Naz;Ali, Madeeha;Khan, Shaista;Ahmad, Khabir
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8339-8343
    • /
    • 2016
  • Background: To determine the outcome and cost saving by placing ultrasound guided surgical clips for tumor localization in patients undergoing neo-adjuvant chemotherapy for breast cancer. Materials and Methods: This retrospective cross sectional analytical study was conducted at the Department of Diagnostic Radiology, Aga Khan University Hospital, Karachi, Pakistan from January to December 2014. A sample of 25 women fulfilling our selection criteria was taken. All patients came to our department for ultrasound guided core biopsy of suspicious breast lesions and clip placement in the index lesion prior to neo-adjuvant chemotherapy. All the selected patients had biopsy proven breast cancer. Results: The mean age was $45{\pm}11.6years$. There were no complications seen after clip placement in terms of clip migration or hemorrhage. The cost of commercially available markers was approximately PKR 9,000 (US$ 90) and that of the surgical clip was PKR 900 (US$ 9). The cost of surgical clips in 25 patients was PKR 22,500 (US$ 225), when compared to the commercially available markers which may have incurred a cost of PKR 225,000 (US$ 2,250). The total cost saving for 25 patients was PKR 202,500 (US$ 2, 025), making it PKR 8100 (US$ 81) per patient. Conclusions: The results of our study show that ultrasound guided surgical clip placement in index lesions prior to neo-adjuvant therapy is a safe and cost effective method to identify tumor bed and response to treatment for further management.

Injection therapy for management of temporomandibullar joint disorders (턱관절장애 치료를 위한 주사요법)

  • Jo, Sanghoon
    • The Journal of the Korean dental association
    • /
    • v.57 no.4
    • /
    • pp.222-232
    • /
    • 2019
  • Injection therapy can be used to treat the refractory and chronic pain situations that are not well responded to conventional therapy in TMD-patients. The target of injection is the intra-articular- and peri-articular tissue of joint and adjacent tissue like muscle. For the success of injectional therapy, selection of injection solution and technique is essential, so discussion will be done about that and one of the promising techniques of intra-articular injection, US-guided TMJ Intrar-articular injection, is also discussed.

  • PDF

Nutritional Factors Affecting Abdominal Fat Deposition in Poultry: A Review

  • Fouad, A.M.;El-Senousey, H.K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.7
    • /
    • pp.1057-1068
    • /
    • 2014
  • The major goals of the poultry industry are to increase the carcass yield and to reduce carcass fatness, mainly the abdominal fat pad. The increase in poultry meat consumption has guided the selection process toward fast-growing broilers with a reduced feed conversion ratio. Intensive selection has led to great improvements in economic traits such as body weight gain, feed efficiency, and breast yield to meet the demands of consumers, but modern commercial chickens exhibit excessive fat accumulation in the abdomen area. However, dietary composition and feeding strategies may offer practical and efficient solutions for reducing body fat deposition in modern poultry strains. Thus, the regulation of lipid metabolism to reduce the abdominal fat content based on dietary composition and feeding strategy, as well as elucidating their effects on the key enzymes associated with lipid metabolism, could facilitate the production of lean meat and help to understand the fat-lowering effects of diet and different feeding strategies.

Initial Value Selection in Applying an EM Algorithm for Recursive Models of Categorical Variables

  • Jeong, Mi-Sook;Kim, Sung-Ho;Jeong, Kwang-Mo
    • Journal of the Korean Statistical Society
    • /
    • v.27 no.1
    • /
    • pp.25-55
    • /
    • 1998
  • Maximum likelihood estimates (MLEs) for recursive models of categorical variables are discussed under an EM framework. Since MLEs by EM often depend on the choice of the initial values for MLEs, we explore reasonable rules for selecting the initial values for EM. Simulation results strongly support the proposed rules.

  • PDF

A Study on Parts Route Selection and Economic Design in Flexible Manufacturing System (유연 제조시스템에서 작업경로선택과 경제적인 설계에 관한 연구)

  • 장석화
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.43
    • /
    • pp.249-263
    • /
    • 1997
  • This paper addresses the parts route selection and economic design in flexible manufactuirng system (FMS). Parts are processed through several stage workstations according to operation sequences. The machine of each workstation can do multiple operation functions. And the operation stage of a part can be processed in several workstations, which are non-identical in functional performance. The objective of this paper is to determine the processing routes of parts, number of machine at each workstation, number of vehicle and makespan time. Two models are suggested. One is assumed that the operation stage of parts can be processed at the only one among several available workstations. Other is assumed that the operation stage of parts is allowed to be processed at several workstations. Parts are transported by automated guided vehicles (AGVs). The decision criteria is to minimize the sum of processing cost, travel cost, setup cost and overhead cost. The formulation of models is represented. A solution algorithm is suggested, and a numerical example is shown.

  • PDF

Model selection algorithm in Gaussian process regression for computer experiments

  • Lee, Youngsaeng;Park, Jeong-Soo
    • Communications for Statistical Applications and Methods
    • /
    • v.24 no.4
    • /
    • pp.383-396
    • /
    • 2017
  • The model in our approach assumes that computer responses are a realization of a Gaussian processes superimposed on a regression model called a Gaussian process regression model (GPRM). Selecting a subset of variables or building a good reduced model in classical regression is an important process to identify variables influential to responses and for further analysis such as prediction or classification. One reason to select some variables in the prediction aspect is to prevent the over-fitting or under-fitting to data. The same reasoning and approach can be applicable to GPRM. However, only a few works on the variable selection in GPRM were done. In this paper, we propose a new algorithm to build a good prediction model among some GPRMs. It is a post-work of the algorithm that includes the Welch method suggested by previous researchers. The proposed algorithms select some non-zero regression coefficients (${\beta}^{\prime}s$) using forward and backward methods along with the Lasso guided approach. During this process, the fixed were covariance parameters (${\theta}^{\prime}s$) that were pre-selected by the Welch algorithm. We illustrated the superiority of our proposed models over the Welch method and non-selection models using four test functions and one real data example. Future extensions are also discussed.