A survey of the satisfaction of patients who have undergone implant surgery with and without employing a computer-guided implant surgical template

  • Youk, Shin-Young;Lee, Jee-Ho;Park, Ji-Man;Heo, Seong-Joo;Roh, Hyun-Ki;Park, Eun-Jin;Shin, Im Hee
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.395-405
    • /
    • 2014
  • PURPOSE. This study aims to investigate the degree of subjective pain and the satisfaction of patients who have undergone an implant treatment using a computer-guided template. MATERIALS AND METHODS. A survey was conducted for 135 patients who have undergone implant surgery with and without the use of the computerguided template during the period of 2012 and 2013 in university hospitals, dental hospitals and dental clinics that practiced implant surgery using the computer-guided template. Likert scale and VAS score were used in the survey questions, and the independent t-test and One-Way ANOVA were performed (${\alpha}=.05$). RESULTS. The route that the subjects were introduced to the computer-guided implant surgery using a surgical template was mostly advices by dentists, and the most common reason for which they chose to undergo such surgery was that it was accurate and safe. Most of them gave an answer that they were willing to recommend it to others. The patients who have undergone the computer-guided implant surgery felt less pain during the operation and showed higher satisfaction than those who have undergone conventional implant surgery. Among the patients who have undergone computer-guided implant surgery, those who also had prior experience of surgery without a computer-guided template expressed higher satisfaction with the former (P<.05). CONCLUSION. In this study, it could be seen that the patients who have undergone computer-guided implant surgery employing a surgical template felt less pain and had higher satisfaction than those with the conventional one, and the dentist's description could provide the confidence about the safety of surgery.

Anterior implant case report using digital guided implant template (임플란트 가이드를 활용한 전치부 수복증례)

  • Kim, Taeeun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.27 no.1
    • /
    • pp.41-50
    • /
    • 2018
  • Guided implant surgery is useful in anterior implant case in terms of fixture installation and temporary crown delivery. For the aesthetic prosthetics in anterior implant, the position of the implant fixture is crucial. Guided surgery is the top-down procedure and we designed prosthetics first and then determine the position of the fixture. Guided surgery can reduce the stress of dentist with difficult anterior implant case.

Implant-supported fixed prosthesis restoration of fully edentulous patient using computer-guided implant surgery and immediate loading: A case report (Computer guided implant surgery와 immediate loading을 활용한 무치악 환자의 전악 임플란트 고정성 보철물 수복 증례)

  • Hyeon-Me Sung;Kyoung-Hee Sul;Sun-Woo Kang;Jung-Han Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.131-139
    • /
    • 2024
  • In a edentulous patient, various methods can be employed for prosthetic treatment using implants, such as implant-supported fixed prostheses, overdentures, hybrid prostheses, and implant assisted removable partial denture. In this case, in a patient with moderate to severe chronic periodontitis requiring full arch extractions, implants were strategically placed using computer-guided surgery. In the maxilla, due to inadequate bone quality and quantity leading to insufficient initial stability, delayed loading was implemented, and interim prosthesis was used during the osseointegration period. In the mandible, stable initial stability was achieved, allowing for immediate loading to reduce patient discomfort. Primary stability is considered the most crucial factor for obtaining immediate loading, so a thorough clinical and radiological evaluation of the remaining alveolar bone quantity and quality must be conducted before surgery.

Full mouth rehabilitation utilizing computer guided implant surgery and CAD/CAM (Computer guided implant surgery와 CAD/CAM을 활용한 전악 수복 증례)

  • Kim, Sungjin;Han, Jung-Suk;Kim, Sung-Hun;Yoon, Hyung-In;Yeo, In-Sung Luke
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.57-65
    • /
    • 2019
  • Computer aided design and manufacturing and implant surgery using a guide template improve restoration-driven implant treatment procedures. This case utilized those digital technologies to make definitive prostheses for a patient. According to the work flow of digital dentistry, cone beam computed tomography established the treatment plan, which was followed to make the guide template for implant placement. The template guided the implants to be installed as planned. The customized abutments and surveyed fixed restorations were digitally designed and made. The metal framework of the removable partial denture was cast from resin pattern using an additive manufacturing technique, and the artificial resin teeth were replaced with the zirconia onlays for occlusal stability. These full mouth rehabilitation procedures provided functionally and aesthetically satisfactory results for the patient.

Clinical problems of computer-guided implant surgery

  • Moon, Seong-Yong;Lee, Kyoung-Rok;Kim, Su-Gwan;Son, Mee-Kyoung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.15.1-15.6
    • /
    • 2016
  • Background: The utilization of a cone-beam computed tomography (CT)-assisted surgical template allows for predictable results because implant placement plans can be performed in the actual surgery. In order to assess the accuracy of the CT-guided surgery, angular errors and shoulder/apex distance errors were evaluated by data fusion from before and after the placement. Methods: Computer-guided implant surgery was performed in five patients with 19 implants. In order to analyze differences of the implant fixture body between preoperative planned implant and postoperative placed implant, angular error and distance errors were evaluated. Results: The mean angular errors between the preoperative planned and postoperative placed implant was $3.84^{\circ}{\pm}1.49^{\circ}$; the mean distance errors between the planned and placed implants were $0.45{\pm}0.48mm$ horizontally and $0.63{\pm}0.51mm$ vertically at the implant neck and $0.70{\pm}0.63mm$ horizontally and $0.64{\pm}0.57mm$ vertically at the implant apex for all 19 implants. Conclusions: It is important to be able to utilize these methods in actual clinical settings by improving the various problems, including the considerations of patient mouth opening limitations, surgical guide preparation, and fixation.

An assessment of accuracy of half-guided implant surgery using implant surgical guide: A case report (임플란트 수술용 가이드를 사용한 부분 유도 임플란트 수술의 정확도 평가: 증례보고)

  • Kim, Choongkil;Lee, Wonsup;Kwon, Ho-Beom
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.150-159
    • /
    • 2019
  • Nowadays, dental implant is one of the widely used treatment options for edentulous patients. Recently, a method of improving the accuracy of implant surgery using an implant surgical guide has been introduced and widely used in order to accurately place the implant in a proper position. Full-guided and half-guided implant surgery can be distinguished according to the level of surgical guide application during the implant surgery. It is true that full-guided implant surgery exhibits higher accuracy, but half- guided implant surgery is often performed in a clinical situation due to the factors such as the circumstances of the operation. A partially edentulous patient who lost teeth due to tooth fracture and periodontal disease was treated using implant and fixed prosthesis. Half-guided implant surgery was performed using an implant surgical guide during implant surgery, the accuracy of implant placement was analyzed.

Frequency of bone graft in implant surgery

  • Cha, Hyun-Suk;Kim, Ji-Wan;Hwang, Jong-Hyun;Ahn, Kang-Min
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.19.1-19.4
    • /
    • 2016
  • Background: Implant surgery has become popular with the advance of surgical techniques such as sinus lifting, guided bone regeneration, and block bone graft. However, there were no data about the frequency of bone graft during implant surgery. The purpose of this study was to report the frequency and types of bone graft depending on dental implant patients' profile to complement the database regarding implant surgery. Methods: The implant operations had been performed from January 2006 to October 2014. The upper and lower jaws were divided into six sextants. A total of 792 sextants were included in this study. Patient information including sex, age, sites, bone graft, and types of bone were investigated. Results: A total of 1512 implants had been placed. Male and female sextants were 421 and 371, respectively (M:F = 1:0.88). Average age was 54.3 (ranging from 20 to 88 years old). Implants were placed in the posterior maxilla (322 sextants, 40.7 %), posterior mandible (286 sextants, 36.1 %), anterior maxilla (127 sextants, 16.1 %), and anterior mandible (57 sextants, 7.2 %). Bone graft was performed in 50.3 % of the sextants. Among the bone grafted sites, sinus lifting with lateral approach (22.1 %) and guided bone regeneration (22.7 %) were performed most frequently. Conclusions: Bone graft in implant surgery was necessary to augment defects. More than half of the sextants needed bone graft for implant installation.

Retrospective Clinical Study on Marginal Bone Loss of Implants with Guided Bone Regeneration (골유도재생술과 동시에 식립한 임플란트의 변연골 흡수량에 대한 후향적 고찰)

  • Park, Seul-Ji;Seon, Hwa-Gyeong;Koh, Se-Wook;Chee, Young-Deok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.6
    • /
    • pp.440-448
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate marginal bone loss of the alveolar crest on implants with or without guided bone regeneration and variables that have influenced. Methods: The clinical evaluation were performed for survival rate and marginal bone loss of 161 endosseous implants installed with guided bone regeneration (GBR) in 83 patients from September 2009 to October 2010 in relation to sex and age of patients, position of implant, implant system, length and diameter of implant. Study group (n=42) implant with GBR procedure, control group (n=41) implant without GBR technique. Simultaneous GBR approach using resorbable membranes combined with autogenous bone graft or freeze-dried bone allograft or combination. Radiographic examinations were conducted at healing abutment connection and latest visit. Marginal bone level was measured. Results: Mean marginal bone loss was 0.73 mm in study group, 0.63 mm in control group. Implants in maxillary anterior area (1.21 mm) were statistically significant in study group (P<0.05), maxillary posterior area (0.81 mm) in control group (P<0.05). Mean marginal bone loss 1.47 mm for implants with diameter 3.4 mm, 0.83 mm for implants of control group with diameter 4.0 mm (P<0.05). Some graft materials showed an increased marginal bone loss but no statistically significant influence of sex, implant type or length. Conclusion: According to these findings, this study demonstrated the amount of marginal bone loss around implant has maintained a relative stable during follow-up periods. We conclude that implants with GBR had similar survival rate and crestal bone level compared with implants in native bone.

Clinical Effectiveness of Bone Grafting Material Using Autogenous Tooth: Preliminary Report (자가치아를 이용한 골이식재의 임상적 유용성: 일차 보고)

  • Lee, Jeong-Hoon;Kim, Su-Gwan;Moon, Sung-Young;Oh, Ji-Su;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.2
    • /
    • pp.144-148
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate the effectiveness of a novel bone grafting material using an autogeneous tooth (AutoBT) and provide the basis for its clinical application. The AutoBT contains organic and inorganic mineral components and is prepared from autogenous grafting material, thus eliminating the risk of immune reactions that may lead to its rejection. AutoBT can be used as bone material as is has both osteoinduction and osteoconduction activities at guided bone regeneration for implant placement and maxillary sinus graft. Methods: In a total of 63 patients, guided bone regeneration surgery was performed at the time of implant placement, and tissue samples were harvested at the time of the second surgery with the patient's consent. Results: There were no complications in guided bone regeneration using autogeneous tooth. Conclusion: We concluded that AutoBT underwent gradual resorption and was replaced by new bone of excellent quality via osteoinduction and osteoconduction.

Risk Factors for Wound Dehiscence after Guided Bone Regeneration in Dental Implant Surgery

  • Kim, Young-Kyun;Yun, Pil-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.3
    • /
    • pp.116-123
    • /
    • 2014
  • Purpose: The purpose of this study was to evaluate risks for wound dehiscence after guided bone regeneration (GBR) in dental implant surgery. Methods: Patients who received dental implant therapy with GBR procedure at Seoul National University Bundang Hospital (Seongnam, Korea) from June 2004 to May 2007 were included. The clinical outcome of interest was complications related to dental implant surgery. The factors influencing wound dehiscence, classified into patient-related factors, surgery-related factors and material-related factors, were evaluated. Results: One hundred and fifteen cases (202 implants) were included in this study. Wound dehiscence (19.1%) was considered a major complication. The risk of wound dehiscence was higher in males than in females (odds ratio=4.279, P =0.014). In the main graft, the allogenic group had the lowest risk of wound dehiscence (odds ratio=0.106, P =0.006). Though the external connection group had a higher risk of wound dehiscence than the internal connection group (odds ratio=2.381), the difference was not significant (P =0.100). Conclusion: In this study, male gender and main graft have the highest risk of wound dehiscence. To reduce wound dehiscence after GBR, instructions on postoperative care with supplementary procedure for the protection of the wound dehiscence is recommended, especially to male patients. A main graft with a gel base can reduce the risk of wound dehiscence.