Browse > Article
http://dx.doi.org/10.4047/jkap.2019.57.1.57

Full mouth rehabilitation utilizing computer guided implant surgery and CAD/CAM  

Kim, Sungjin (Department of Prosthodontics, Seoul National University School of Dentistry)
Han, Jung-Suk (Department of Prosthodontics, Seoul National University School of Dentistry)
Kim, Sung-Hun (Department of Prosthodontics, Seoul National University School of Dentistry)
Yoon, Hyung-In (Department of Prosthodontics, Seoul National University School of Dentistry)
Yeo, In-Sung Luke (Department of Prosthodontics, Seoul National University School of Dentistry)
Publication Information
The Journal of Korean Academy of Prosthodontics / v.57, no.1, 2019 , pp. 57-65 More about this Journal
Abstract
Computer aided design and manufacturing and implant surgery using a guide template improve restoration-driven implant treatment procedures. This case utilized those digital technologies to make definitive prostheses for a patient. According to the work flow of digital dentistry, cone beam computed tomography established the treatment plan, which was followed to make the guide template for implant placement. The template guided the implants to be installed as planned. The customized abutments and surveyed fixed restorations were digitally designed and made. The metal framework of the removable partial denture was cast from resin pattern using an additive manufacturing technique, and the artificial resin teeth were replaced with the zirconia onlays for occlusal stability. These full mouth rehabilitation procedures provided functionally and aesthetically satisfactory results for the patient.
Keywords
Digital removable partial denture; Digital dentistry; Implant; Computer-aided design/computer-aided manufacturing (CAD/CAM); Computer guided implant surgery;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Yoon TH, Madden JC, Chang WG. A technique to restore worn denture teeth on a partial removable dental prosthesis by using ceramic onlays with CAD/CAM technology. J Prosthet Dent 2013;110:331-2.   DOI
2 Bilgin MS, Baytaroglu EN, Erdem A, Dilber E. A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication. Eur J Dent 2016;10:286-91.   DOI
3 Azari A, Nikzad S. Computer-assisted implantology: historical background and potential outcomes-a review. Int J Med Robot 2008;4:95-104.   DOI
4 Garber DA, Belser UC. Restoration-driven implant placement with restoration-generated site development. Compend Contin Educ Dent 1995;16:796, 798-802, 804.
5 Touati B. Biologically driven prosthetic options in implant dentistry. Pract Proced Aesthet Dent 2004;16:517-20.
6 Kapos T, Ashy LM, Gallucci GO, Weber HP, Wismeijer D. Computer-aided design and computer-assisted manufacturing in prosthetic implant dentistry. Int J Oral Maxillofac Implants 2009;24:110-7.
7 Becker CM, Kaiser DA. Surgical guide for dental implant placement. J Prosthet Dent 2000;83:248-51.   DOI
8 Wu J, Wang XB, Zhao XH, Zhang CB, Gao B. A study on the fabrication method of removable partial denture framework by computer-aided design and rapid prototyping. Rapid Prototyping J 2012;18:318-23.   DOI
9 Kattadiyil MT, Mursic Z, AlRumaih H, Goodacre CJ. Intraoral scanning of hard and soft tissues for partial removable dental prosthesis fabrication. J Prosthet Dent 2014;112:444-8.   DOI
10 Arnold C, Hey J, Schweyen R, Setz JM. Accuracy of CADCAM-fabricated removable partial dentures. J Prosthet Dent 2018;119:586-92.   DOI
11 Zitzmann NU, Marinello CP. Treatment plan for restoring the edentulous maxilla with implant-supported restorations: removable overdenture versus fixed partial denture design. J Prosthet Dent 1999;82:188-96.   DOI
12 Zarone F, Apicella A, Nicolais L, Aversa R, Sorrentino R. Mandibular flexure and stress build-up in mandibular fullarch fixed prostheses supported by osseointegrated implants. Clin Oral Implants Res 2003;14:103-14.   DOI
13 Schneider D, Schober F, Grohmann P, Hammerle CH, Jung RE. In-vitro evaluation of the tolerance of surgical instruments in templates for computer-assisted guided implantology produced by 3-D printing. Clin Oral Implants Res 2015;26:320-5.
14 Gehrke P, Alius J, Fischer C, Erdelt KJ, Beuer F. Retentive strength of two-piece CAD/CAM zirconia implant abutments. Clin Implant Dent Relat Res 2014;16:920-5.   DOI
15 Raico Gallardo YN, da Silva-Olivio IRT, Mukai E, Morimoto S, Sesma N, Cordaro L. Accuracy comparison of guided surgery for dental implants according to the tissue of support: a systematic review and meta-analysis. Clin Oral Implants Res 2017;28:602-12.   DOI
16 Sun Y, Luebbers HT, Agbaje JO, Schepers S, Politis C, Van Slycke S, Vrielinck L. Accuracy of dental implant placement using CBCT-derived mucosa-supported stereolithographic template. Clin Implant Dent Relat Res 2015;17:862-70.   DOI
17 Kim MJ, Oh SH, Kim JH, Ju SW, Seo DG, Jun SH, Ahn JS, Ryu JJ. Wear evaluation of the human enamel opposing different Y-TZP dental ceramics and other porcelains. J Dent 2012;40:979-88.   DOI
18 Wittneben JG, Buser D, Salvi GE, Burgin W, Hicklin S, Bragger U. Complication and failure rates with implant-supported fixed dental prostheses and single crowns: a 10-year retrospective study. Clin Implant Dent Relat Res 2014;16:356-64.   DOI
19 Roediger M, Gersdorff N, Huels A, Rinke S. Prospective evaluation of zirconia posterior fixed partial dentures: fouryear clinical results. Int J Prosthodont 2010;23:141-8.
20 Sailer I, Gottnerb J, Kanelb S, Hammerle CH. Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: a 3-year follow-up. Int J Prosthodont 2009;22:553-60.