• Title/Summary/Keyword: group standards

Search Result 1,188, Processing Time 0.028 seconds

Construction of a 40-channel SQUID System and Its Application to Neuromagnetic Measurements

  • Lee, Y.H.;Kim, J.M.;Kwon, H.C.;Park, Y.K.;Park, J.C.;Lee, D.H.;Ahn, C.B.
    • Progress in Superconductivity
    • /
    • v.2 no.1
    • /
    • pp.20-26
    • /
    • 2000
  • A 40-channel superconducting quantum interference device (SQUID) system was constructed for measuring neuromagnetic fields. Main features of the system are the use of double relaxation oscillation SQUIDs (DROSs), and planar gradiometers measuring magnetic field components tangential to the head surface. The DROSs with high flux-to-voltage transfers enabled direct readout of the SQUID output by room-temperature dc preamplifiers and simple flux-locked loop circuits could be used for SQUID operation. The pickup coil is an integrated first-order planar gradiometer with a baseline of 40 mm. Average noise level of the 40 channels is around 1.2 $fT/cm/{\surd}Hz$ at 100 Hz, corresponding to a field noise of 5 $fT/{\surd}Hz$, operated inside a magnetically shielded room. The SQUID insert was designed to have low thermal load, minimizing the loss of liquid helium. The constructed system was applied to measure auditory-evoked neuromagnetic fields.

  • PDF

A Low-noise Double Relaxation Oscillation SQUID Magnetometer for Measuring Magnetoencephalogram

  • 강찬석;이용호;권혁찬;김진목;윤병운
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.151-158
    • /
    • 2002
  • We developed a useful SQUID magnetometer for biomagnetic applications, magnetoencepha-logram(MEG) and magnetocardiogram(MCG), etc. The SQUIDs are based on Double Relaxation Oscillation SQUID(DROS). DROS consists of two SQUIDs(signal SQUID and reference SQUID) in series, and a relaxation circuit of an inductor and a resistor. Specially we used single reference junction instead of the reference SQUID. The SQUIDs are based on hysteretic $Nb/AlO_{x}$Nb junctions, fabricated by using a simple four level process. Because DROS magnetometer has large flux-to-voltage transfer coefficient, we can use simple flux-locked loop electronics fur SQUID operation. When the DROS magnetometer was operated inside a magnetically shielded room, its average magnetic field noise was about 3 (equation omitted) at 100 Hz. This noise level is low enough to measure biomagnetic fields. In this paper, we describe noise characteristics of DROS magnetometer, depending on the operation condition . .

  • PDF

The effect of using a Nursing Standards on the Quality of Nursing care in Musculo-skeletal Disorder Patients (간호표준 적용이 근${\cdot}$골격장애 환자의 간호질에 미치는 효과)

  • Choe, Sun-Ok
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.9 no.1
    • /
    • pp.89-101
    • /
    • 2003
  • Purpose : this study was to examine the effect of using a nursing standards for the quality of nursing care in musculo-skeletal patients. Method : The approach to nursing quality assurance evaluation was selected process-outcome framework. The subjects ware 100 case of musculo-skeletal patients in orthopedic surgery nursing care unit of E. university hospital in seoul. The data of a control group were collected from 23 December 2001 to 20 March 2002 and an experimental group were collected from 1 June to 25 August 2002. The instruments used for this study were a nursing care standards in musculo-skeletal disorder patients developed by the investigator and an evaluation tool for the quality of nursing care in orthopedic surgery patients developed by soon-ook Choi in 1995. It's reliability is Cronbach alpha=.8628. The data were analyzed by means of $x^1$-test, t-test, ANOVA with SPSS program. Results : This study are as fellows : 1. Scores of the quality of nursing care in standard 1 in the experimental group were higher than those of the control group with no significant difference(t=-8.793, p=.000), scores of the quality of nursing care in standard 2 in the experimental group were higher than those of the control group with significant difference(t=-8.793, p=.000) and standard 3 in the experimental group were higher than those of the control group with significant difference(t=-10.550, p=.000). scores of the quality of nursing care in standard 4 in the experimental group were higher than those of the control group with significant difference(t=-8.793, p=.000). scores of the quality of nursing care in standard 4 in the experimental group were higher than those of the control group with no significant difference(t=-1.833, p=.070). 2. Scores of the quality of nursing care in criteria 28 of 33 criteria in the experimental group were higher than those of the control group with significant difference in 12 criteria(p<.05 ). 3. Scores of the quality of nursing care in standard 1 to standard 4(process evaluation); the experimental group were higher than those of the control group with significant difference(t=-10.704, p=.000). scores of the quality of nursing care in standard 5(outcome evaluation); the experimental group were higher than those of the control group. but no significant difference(t=-1.833, p=.070). 4. Scores of the quality of nursing care in experimental group were higher than those of the control group with significant difference(t=-10.794, p=.000). Conclusion : Through this study, I'm sure that using a nursing care standards in musculo-skeletal disorder patients improve quality of nursing care and nursing care standards are effective nursing care.

  • PDF

A Study on the Body Proportion and Proportional Dimension Standards for Chinese Women - Focusing on the analysis of the high-frequence group -

  • Kim, Eun-Hee;Sohn, Hee-Soon
    • Journal of Fashion Business
    • /
    • v.10 no.6
    • /
    • pp.91-109
    • /
    • 2006
  • This study aims at strengthening the national competitiveness of Korea's clothing industry as it provides substantial information on the human body proportion and proportional dimension standards for Chinese women and improves the fitness of clothing, considering human proportion in the production of clothing products for export to China. This study selected by simple random sampling Chinese women in Beijing and Shanghai, China, whose age is between 19-50 from June 23 to August 7, 2004. The stature of the average Chinese woman belonging to the High Frequency group is 7.09 times as long as the length of the head. We developed the body proportional dimension standards with the same proportion with High-Frequence group. The basic size of proportional dimension standards for Chinese women has the stature of 159cm, (chest circumference)/2 of 42.8cm.

Properties of YBCO Step-edge Junction Fabricated on Different Crystal Orientation of Sapphire Substrate (사파이어 기판의 다른 결정방향 위에 제작된 YBCO step-edge 접합의 특성)

  • H. R. Lim;I-S Kim;Y. K. Park;J. C. Park
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.60-64
    • /
    • 2001
  • We have studied properties of step-edge Junction prepared with crystal orientation of sapphire substrate. The Step on sapphire substrates fabricated by conventional photolithography method and Ar ion milling method. $CeO_2$ buffer layer and in-situ YBCO thin film were deposited on the stepped sapphire substrates by a pulsed laser deposition method with the predetermined optimized condition. The step angle was centre fled low angle of about $25^{\circ}$. The YBCO film thickness was varied to obtain various thickness ratios of the film to the step height in a range from 0.7 to 1.2. I-V curves of junction were showed RSJ-behavior, double junction structure, and hysteresis due to the crystal orientation of substrate.

  • PDF

A study of the impact of using a nursing care standards on the quality of nursing care in gastrectomy patients (위절제술환자의 간호실무표준 사용이 간호의 질에 미치는 영향)

  • Woo, Young-Ja
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.2 no.2
    • /
    • pp.97-107
    • /
    • 1996
  • Nursing standards determine the type and extent of services that are delivered to the patients and define quality care and communicate the institution's expectations of care. Thus, taking the standard of care and incorporating it into a welldefined indicator of excellent patient care becomes one of the first activities in setting up the nursing service's quality assurance process. The purpose of this study was to determine the impact of using a nursing care standards for the quality of nursing care in gastrectomy patients. The subjects were composed of fourty-two under going gastrectomy patients with stomach cancer in general surgery nursing care unit of K University Hospital in Pusan. The data was collected from January 3 to April 13,1996. The subjects were divided into a control group - those admitted from Jan.3 to Feb.12 and an experimental group those admitted from Feb.18 to April 13. The instruments used for this study were a nursing care standards in gastrectomy patients developed by the investigator and an evaluation tool for the quality of nursing care in abdominal surgery patients developed by Byoung-Sook Lee in 1995. The data was analized by means of chi-square test, t-test and Cronbach-alpha test with the SAS System. The result was as follows : The hypothesis, that scores of the quality of nursing care in the experimental group would be higher than that of the control group. was supported(t=-6.12, p=0.00). The detailed results of each standards of evaluation tool were as follows : The mean score of the experimental group was significantly higher than that of the control group in audit standard 1:'Collection of basic data of the patients', (t=-3.76, p=0.00). The mean score of the experimental group was significantly higher than that of the control group in audit standard 2 : 'Defining nursing diagnoses(or nursing problems)', (t= (-), p= (-) ). The mean score of the experimental group was significantly higher than that of the control group in audit standard 3:'Estabilishment of nursing care plan according to nursing diagnoses(or nursing problems)',(t= (-), p= (-) ). The mean score of the experimental group was significantly higher than that of the control group in audit stndard 4:'Implimentation of nursing care plan', (t=-2.38, p=0.01). The mean score of the experimental group was significantly higher than that of the control group in audit standard 8 : 'Increase of the knowledge of health related to surgery',(t=-2.40, p=0.01). No significant differences between the mean scores of the experimental group and that of the control group in audit standard 5 : 'Recover and maintain of the physical function', audit standard 6:'Prevention of the post-operative complication', audit standard 7 : 'Decrease of discomfort caused by operation', and audit standard 9 : 'Patient satisfaction in nursing care' were found. The standards of evaluation tool were devided into two dimension. One was process dimension which contains four standards(audit standard 1 to 4), the other was outcome dimension which contains five standards(audit standard 5 to 9). The mean score of the experimental group was significantly higher than that of the control group in process dimension (t=-12.30, p=0.00), but no significant difference between the mean scores of the experimental group and that of the control group in outcome dimension was found. From these results, it is concluded that using a nursing care standards in gastrectomy patients promotes quality of nursing care and nursing care standards of various fields are necessary for effective nursing care.

  • PDF