• Title/Summary/Keyword: groundwater quality

Search Result 617, Processing Time 0.033 seconds

Assessment of Water Pollution by Discharge of Abandoned Mines (휴폐광산 지역에서 유출되는 하천수의 오염도 평가)

  • Kim Hee-Joung;Yang Jay-E.;Ok Yong-Sik;Lee Jai-Young;Park Byung-Kil;Kong Sung-Ho;Jun Sang-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.5
    • /
    • pp.25-36
    • /
    • 2005
  • Several metalliferous and coal mines, including Myungjin, Seojin and Okdong located at the upper watershed of Okdong stream, were abandoned or closed since 1988 due to the mining industry promotion policy. Thus these disposed an enormous amount of mining wastes without a proper treatment facilities, resulting in water pollution in the downstream areas. Acid mine drainage (AMD) and waste water effluents from the closed coal mines were very strongly acidic showing pH ranges of 2.7 to 4.5 and had a high level of Total Dissolved Solids (TDS) showing the ranges of 1,030 to 1,947 mg/L. Also heavy metal concentrations in these samples such as Fe, Cu, Cd and anion such as sulfate were very high. Concentrations of water soluble heavy metals in the Okdong streams were in the orders of Fe>Al>Mn>Zn>Cu>Pb>Cd, indicating Fe from the AMD and waste water effluents contributed greatly to the quality of water and soil in the lower watershed of Okdong stream. Copper concentrations in the effluents from the tile drainage of mine tailings dams were highest during the raining season. Water Pollution Index (WPI) of the surface water at the upper stream of Okdong river where AMD of the abandoned coal mines was flowed into main stream were in the ranges of 16.3 to 47.1. On the other hand, those at the mid stream where effluents from tailings dams and coal mines flowed into main stream were in the WPI ranges of 10.6 to 19.5. However, those at the lower stream were ranged from 10.6 to 14.9. These results indicated that mining wastes such as AMD and effluents from the closed mines were the major source to water pollution at the Okdong stream areas.

Analysing the effect of impervious cover management techniques on the reduction of runoff and pollutant loads (불투수면 저감기법의 유출량 및 오염부하량 저감 효과 분석)

  • Park, Hyung Seok;Choi, Hwan Gyu;Chung, Se Woong
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.1
    • /
    • pp.16-34
    • /
    • 2015
  • Impervious covers(IC) are artificial structures, such as driveways, sidewalks, building's roofs, and parking lots, through which water cannot infiltrate into the soil. IC is an environmental concern because the pavement materials seal the soil surface, decreasing rainwater infiltration and natural groundwater recharge, and consequently disturb the hydrological cycle in a watershed. Increase of IC in a watershed can cause more frequent flooding, higher flood peaks, groundwater drawdown, dry river, and decline of water quality and ecosystem health. There has been an increased public interest in the institutional adoption of LID(Low Impact Development) and GI(Green Infrastructure) techniques to address the adverse impact of IC. The objectives of this study were to construct the modeling site for a samll urban watershed with the Storm Water Management Model(SWMM), and to evaluate the effect of various LID techniques on the control of rainfall runoff processes and non-point pollutant load. The model was calibrated and validated using the field data collected during two flood events on July 17 and August 11, 2009, respectively, and applied to a complex area, where is consist of apartments, school, roads, park, etc. The LID techniques applied to the impervious area were decentralized rainwater management measures such as pervious cover and green roof. The results showed that the increase of perviousness land cover through LID applications decreases the runoff volume and pollutants loading during flood events. In particular, applications of pervious pavement for parking lots and sidewalk, green roof, and their combinations reduced the total volume of runoff by 15~61 % and non-point pollutant loads by TSS 22~72 %, BOD 23~71 %, COD 22~71 %, TN 15~79 %, TP 9~64 % in the study site.

The Synthetic Study of Environmental Contamination at the Seokdae Municipal Waste Landfill in Pusan (부산 석대 생활폐기물 매립장의 환경오염에 대한 종합적 연구)

  • 김병우;정상용;이민희;이병헌
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.98-103
    • /
    • 2001
  • In order to understand the characteristics of leachate at the Seokdae municipal waste landfill in the Pusan city, the correlation between leachate pollution loading and volume of gas production. concentration of gas and subsidence of ground, the characteristical methos, geochemical analyses and laboratory column tests using samples of gases, leachate and surface soil of Seokdae waste landfill area. Through the analysis of water balance, leachate flow rate and pollution loading were estimated. Geistatistical analysis of four gas components ( $O_2$, C $H_4$, $H_2$S and CO) shows the possibility of ground subsidence around the group of a site with high concentration of gas. From geochemical analyses of leachate, EC and Total-Alkalinity of ground subsidence around the group of a site with high concentration of gas. From geochemical analysis of leachate, Ec and Total-Alkalinity were increased, and Cl, Cr, Mn, Cu, Zn, Cd and Pb were decreassed comparing to the part, and the type of water quality was Na-HC $O_3$ in trilinear diagram. It shows that biodecomposition of municipal wastes continues actively. From the analysis of water balance, the total leachate flow rate is about 465.11㎥/day and pure pollution loading of Cl, Mn and Fe are estimated to 223.8kg/day, 0.2kg/day, 0.3kg/day, respectively. The laboratory column test of residual soil and landfill soil shows 0.206cm and 0.019cm for linear velocity(equation omitted), 0.234 $\textrm{cm}^2$/min and 0.018$\textrm{cm}^2$/min for diffusion coefficient ( $D_{ι}$), and 1.136cm and 0.095cm longitudinal dispersion index ($\alpha$$_{ι}$), respective]y. It demonstrates that the delay time of contamination for residual soil is shorter than that of landfill soil.

  • PDF

A Function and Weight Selection of Ecosystem Service Function for the Eco-friendly Protected Horticulture Complex in Agricultural Landscape (시설원예단지의 친환경적 조성을 위한 생태계서비스 기능 및 가중치 산정)

  • SON, Jinkwan;KONG, Minjae;SHIN, Yukung;YUN, Sungwook;KANG, Donghyeon;Park, Minjung;LEE, Siyoung
    • Journal of Wetlands Research
    • /
    • v.19 no.4
    • /
    • pp.533-541
    • /
    • 2017
  • Agricultural landscape has many ecosystem service functions. However, the development of the horticulture complex has no consideration for environmental conservation. Therefore, we analyzed the priorities of ecosystem service functions required for the composition. The study was conducted in three stages. As a result of the first survey, 17 functions were selected to be improved. In the second survey, 12 functions were selected excluding 5 functions. Finally, 1. Measures for water purification, 2. Groundwater recharge plan, 3. Surface water storage space, 4. Flood control measures, 5. Vegetation diversity space, 6. Carbon emission reduction plan, 7. Aquatic insect habitat space, 8. Amphibian reptiles 9. Landscape and Waste Management, 10. Bird Species Space, 11. Heat Island Mitigation Plan, 12. Experience / Ecological Education Plan. We proposed the structure, capacity, flow rate, arrangement and form of the water treatment facility to improve water quality by improving the function. We proposed a reservoir space of 7-10% for groundwater recharge. The development of reservoir and storage facilities suitable for the Korean situation is suggested for the surface water storage and flood control measures. And proposed to secure a green space for the climate cycle. Proposed habitat and nutrient discharge management for biodiversity. We propose green area development and wetland development to improve the landscape, and put into the facilities for experiential education. The results of the research can be utilized for the development and improvement of the horticultural complex.

Adsorption of Trace Metals on the Natural Amorphous Iron Oxyhydroxide from the Taebag Coal Mine Area (태백 탄전 지대의 비정질 철 수산화물에 대한 희귀원소의 흡착)

  • Yu, Jae-Young;Park, In-Kyu
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.1 no.1
    • /
    • pp.23-32
    • /
    • 1994
  • To determine the apparent equilibrium constants, K$_{ad,app}$, for the adsorption reactions of trace metals on amorphous iron oxyhydroxide (AIO) in the Taebag coal mine area, time-adsorption and pH-adsorption experiments were performed for a selected bottom sediment mainly comprised of AIO from the study area. The results from the adsorption experiments indicate that most of the trace metals, except Pb, achieve equilibrium states with AIO and thus, the calculated K$_{ad,app}$ may represent the true apparent equilibrium constants. K$_{ad,app}$ and the stoichiometric coefficients of proton, x, of the adsorption reactions between the trace metals and AIO were respectively calculated from the intercepts and slopes of the regression lines of log($\Gamma$/ [M]$_{aq}$)against pH provided by pH-adsorption experiments. The calculated K$_{ad,app}$ this study has the values of the range from 10$^{-4.5}$ to 10$^{2.75}$ , which is much different from the reported values by other investigators for simple experimental systems. K$_{ad,app}$ of this study is more or less close but not exactly pertinent to the estimated values for the other natural systems. It indicates that K$_{ad,app}$ for the adsorption reactions in the aquatic system in the study area is unique and thus should be determined befor the adsorption modelling. The calculated x of this study has the values of the range from -0.3 to 0.7, which is also much different from what most geochemists generally accept. The discrepancy in x may be due to the competition among different kinds of ionic species on the adsorption site or simulataneous occurrence of different kinds of adsorption reactions. The results from this study should help construct an appropriate adsorption model for the aquatic systems polluted by the coal mine drainage in the Taebag area. With the constructed model, one can describe the concentration variations of trace metals due to the adsorption in the system, which is an essential part of the investigation on the water quality affected by coal mine drainage in the Taebag coal field.

  • PDF

Neutralization of Acid Rock Drainage from the Dongrae Pyrophyllite Deposit: A Study on Behavior of Heavy Metals (동래 납석광산 산성 광석배수의 중화실험: 중금속의 거동 특성 규명)

  • 염승준;윤성택;김주환;박맹언
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.4
    • /
    • pp.68-76
    • /
    • 2002
  • In this study, we have investigated the geochemical behavior and fate of heavy metals in acid rock drainage (ARD). The ARD was collected from the area of the former Dongrae pyrophyllite mine. The Dongrae Creek waters were strongly acidic (pH : 2.3~4.2) and contained high concentrations of $SO_4$, Al, Fe, Mn, Pb, Cu, Zn, and Cd, due to the influence of ARD generated from weathering of pyrite-rich pyrophyllite ores. However, the water quality gradually improved as the water flows downstream. In view of the change of mole fractions of dissolved Fe, Al and Mn, the generated ARD was initially both Fe- and AA-ich but progressively evolved to more Al-rich toward the confluence with the uncontaminated Suyoung River. As the AR3 (pH 2.3) mixed with the uncontaminated waters (pH 6.5), the pH increased up to 4.2, which caused precipitation of $SO_4$-rich Fe hydroxysulfate as a red-colored, massive ferricrete precipitate throughout the Dongrae Creek. Accompanying the precipitation of ferricrete, the Dongrae Creek water progressively changed to more Al-rich toward downstream sites. At the mouth of the Dongrae Creek, it (pH 3.4) mixed with the Suyoung River (pH 6.9), where pH increased to 5.7, causing precipitation of Al hydroxysulfate (white precipitates). Neutralization of the ARD-contaminated waters in the laboratory caused the successive formation of Fe precipitates at pH<3.5 and Al precipitates at higher pH (4~6). Manganese compounds were precipitated at pH>6. The removal of trace metals was dependent on the precipitation of these compounds, which acted as sorbents. The pHs for 50% sorption ($pH_{50}$) in Fe-rich and Al-rich waters were respectively 3.2 and 4.5 for Pb, 4.5 and 5.8 for Cu, 5.2 and 7.4 for Cd, and 5.8 and 7.0 for Zn. This indicates that the trace metals were sorbed preferentially with increasing pH in the general order of Pb, Cu, Cd, and Zn and that the sorption of trace metals in Al-rich water occurred at higher pH than those in Fe-rich water. The results of this study demonstrated that the partitioning of trace metals in ARD is not only a function of pH, but also depends on the chemical composition of the water.

Development of the Compressed Packer Grouting Device for Preventing the Inflow of Polluted Groundwater (오염지하수 유입방지를 위한 압축패커 그라우팅 장치 개발)

  • Cho, Heuy-Nam;Choi, Sang-Il
    • The Journal of Engineering Geology
    • /
    • v.19 no.4
    • /
    • pp.433-439
    • /
    • 2009
  • The compressed packer device is designed to improve the underground contamination prevention facilities of ground water wells. As for the device, the installation is simple because of the safety lock device and the compression of the casing are simple the installation is simple. There is no leakage of ground water because the pressure resistance with $4.5\;kg/cm^2$ makes it equipped with the watertightness The single casing is installed and the reaming for grouting is possible with 300 mm excavation so that installation cost can be saved. Silicon rubber is used for the compressed packer so that the extension rate is 590%. In terms of environmental pollution, it is an environmental friendly product which does not contain harmful ingredients such as Pb, Cd, and phenol. below the standard or undetectable level Furthermore, the installation costs are 35 to 62% or lower than the conventional grouting construction method and are 87% or lower than the expansion packer construction method, the new environmental technology No.47 Also, the device is designed to meet the relevant regulations such as Rules on Preserving the Ground Water Quality, The Standard on Jeju Island Ground Water Development and Facility Installation and Management, and The Plan and Guideline on Operating and Managing the Small-Scale Tap Water Facilities of Ministry of Environment and Ministry of Food, Agriculture, Forestry and Fisheries.

Evaluation of Groundwater Quality in Northern Bangladesh for Irrigation, Drinking and Industrial Uses (북부 방글라데시에서 관개, 음용 및 공업용수로 사용되는 지하수의 수질)

  • Islam, Jahidul Mohammad;Laiju, Nahida;Nasirullah, Tarek;Miah, Nuruddin Mohammad;Owen, Jeffrey S.;Kim, Bom-Chul
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.3
    • /
    • pp.281-296
    • /
    • 2010
  • 방그라데시 북부에 위치한 풀바리 우파질라 지역의 지하수에서 pH, EC, 주요 양이온 ($Ca^{2+}$, $Mg^{2+}$, $Na^+$, $K^+$, $Zn^{2+}$, $Cu^{2+}$, $Mn^{2+}$, $Fe^{3+}$, and $As^{3+}$), 주요 음이온 (${CO_3}^{2-}$, $HCO_3{^-}$, $NO_3{^-}$, ${SO_4}^{2-}$ and $Cl^-$) 그리고 total dissolved solids (TDS) 등의 용존물질 함량을 측정하였다. 또한 sodium adsorption ratio (SAR), soluble sodium percentage (SSP), residual sodium carbonate (RSC), 경도 등의 지표도 계산하였다. 전체적으로 지하수의 pH는 약알칼리성 (6.24 - 8.10)을 띄었으며, 주요 양이온은 $Ca^{2+}$, $Mg^{2+}$ and $Na^+$ 이었고, 주요 음이온은 $HCO_3{^-}$ and $Cl^-$ 으로서 전형적인 담수의 이온조성을 보였다. $Cu^{2+}$, $Mn^{2+}$ and $Fe^{3+}$ 의 최대 농도는 각각 1.71, 0.606, 0.125 mg/L 이었다. 방글라데시의 여러 지역에서는 비소에 의한 지하수의 오염이 흔히 나 타나고 있으나 이지역에서 비소의 최대농도가 0.41 mg/L로서 기준치인 0.05 mg/L 보다 낮은 오 염도를 보였다. TDS와 SAR, SSP 등으로 볼 때 이 지역의 지하수는 대부분 양호한 수질을 가지는 담수인 것으로 평가된다. $As^{3+}$, $Zn^{2+}$, $Mn^{2+}$, $Fe^{3+}$, ${SO_4}^{2-}$, $NO_3{^-}$ and $Cl^-$ 등의 농도는 음용수로 적합한 수준이었으나 일부 항목은 특정 산업용도로는 부적합한 농도를 보였다. 현재로서는 이지역 의 지하수는 대부분 음용이 가능하고 일부 산업용에 대해서만 부적합성을 보였다. 그러나 앞으로 지 하수의 이용과 산업활동이 증가하면 방글라데시의 많은 다른 지역의 지하수에서 발생한 사례와 같 이 용존물질의 농도가 증가하여 물의 용도에 제한을 받게 될 우려가 있다.

A Study on Feasibility and Applicability of Pneumatic Waste Collection System (쓰레기 수송관로 방식의 적용사례 및 실용에 관한 연구)

  • 민병균;이재영;최상일
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.1
    • /
    • pp.109-117
    • /
    • 1997
  • The dust chute was a part of equipment in apartment which have been settled down as new residential style in this country since 1960s. However, the dust chute was destructed by results of social discussion, and it ended up old remains which cannot be found in new towns. Nowadays, chute was substituted a collecting system from extra collecting sites which were prepared near residential area. This phenomenon was caused by the poor separating collection. Since the early part of 1995, the whole vocal operating the volume-base charge system has been placed as the institution capable of recycling and separating collection of residential wastes in this country. People pursue the residential quality which is suitable to the Greenround period. Such a diverse effort corresponding to the social change can be also accomplished in the field of waste collecting transportation. In this paper, the local heating system and waste combustion site and hollow are already applied to the new residential area in the form of housing development. After investigating of the waste collecting transportation method in other countries related to such facilities, this paper represents the feasibility and applicability of pneumatic waste collection system which is used practically in the new housing complex and large facilities in other countries.

  • PDF

Design Guidlines of Geothermal Heat Pump System Using Standing Column Well (수주지열정(SCW)을 이용한 천부지열 냉난방시스템 설계지침)

  • Hahn, Jeong-Sang;Han, Hyuk-Sang;Hahn, Chan;Kim, Hyong-Soo;Jeon, Jae-Soo
    • Economic and Environmental Geology
    • /
    • v.39 no.5 s.180
    • /
    • pp.607-613
    • /
    • 2006
  • For the reasonable use of low grade-shallow geothermal energy by Standing Column Well(SCW) system, the basic requirements are depth-wise increase of earth temperature like $2^{\circ}C$ per every 100m depth, sufficient amount of groundwater production being about 10 to 30% of the design flow rate of GSHP with good water quality and moderate temperature, and non-collapsing of borehole wall during reinjection of circulating water into the SCW. A closed loop type-vertical ground heat exchanger(GHEX) with $100{\sim}150m$ deep can supply geothermal energy of 2 to 3 RT but a SCW with $400{\sim}500m$ deep can provide $30{\sim}40RT$ being equivalent to 10 to 15 numbers of GHEX as well requires smaller space. Being considered as an alternative of vertical GHEX, many numbers of SCW have been widely constructed in whole country without any account for site specific hydrogeologic and geothermal characteristics. When those are designed and constructed under the base of insufficient knowledges of hydrgeothermal properties of the relevant specific site as our current situations, a bad reputation will be created and it will hamper a rational utilization of geothermal energy using SCW in the near future. This paper is prepared for providing a guideline of SCW design comportable to our hydrogeothermal system.