• 제목/요약/키워드: groundwater quality

검색결과 617건 처리시간 0.024초

이상 고온 조건에서 지하수 냉방 처리가 딸기의 생육과 수량 및 품질에 미치는 영향 (Effects of Groundwater Cooling Treatment on Growth, Yield, and Quality of Strawberries under High Temperature Conditions)

  • 이규빈;이정은;최윤의;박영훈;최영환;강남준;강점순
    • 한국환경과학회지
    • /
    • 제27권8호
    • /
    • pp.631-639
    • /
    • 2018
  • A Cultivation method to minimize the damage caused by high temperatures was studied by investigating the effects of groundwater cooling treatment on the growth, yield, and quality of strawberries. In the groundwater cooling treatment, the daily average temperature of the rhizosphere was reduced from $26.9^{\circ}C$ to $24.9^{\circ}C$. The root length increased by 0.3-9.2 cm, depending on the cultivar and growth period. The leaf number, leaf area, leaf length, leaf diameter, and plant height also increased, especially in the cultivars 'Seolhyang' and 'Maehyang', resulting in higher fresh and dry weights. The number of fruit per plant increased from 7.7 to 12.5 in 'Seolhyang', and the fruit weight increased by 0.3 g in 'Seolhyang' and 1.3 g in 'Maehyang'. The fruit hardness increased, but no significant difference in fruit coloration was observed. The sugar content of the fruit was improved by $0.2-0.3^{\circ}Brix$. Therefore, groundwater cooling of the rhizosphere was effective in improving the growth and productivity of strawberries under abnormally high temperature conditions and can be considered a cost-efficient cooling system.

강원도 및 경기도 소재 유류오염지역의 수질특성, 발현 생분해능과 오염물질 저감속도 (A Study on Groundwater Quality and Biodegradability at the Petroleum Contaminated Sites of Kangwon and Gyeonggi Provinces, Korea)

  • 최현미;이진용;박유철
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권2호
    • /
    • pp.24-33
    • /
    • 2010
  • This study focused on the groundwater quality, biodegradability and attenuation rate at the petroleum contaminated sites of Kangwon and Gyeonggi Provinces, Korea. For groundwater quality, Kangwon site showed chemical compositions of $Ca-SO_4+Cl$, $Ca-HCO_3$ and $Na+K-HCO_3$ types, while Gyeonggi site showed chemical compositions of $Ca-SO_4$, $Ca-HCO_3$ and $Na-HCO_3$ types. $Na+K-HCO_3$ and $Na-HCO_3$ types were detected only in February. Among many biodegradation processes, the majority was attributed to biodegradation from denitrification in both area. In Kangwon site, biodegradation from denitrification occupied 63.5%, and in Gyeonggi site it was 39.45%. Biodegradation from the most efficient aerobic respiration occupied 7.12% in Kangwon site, while Gyeonggi site in it did 27.29%. Point attenuation rate of BTEX in Gyeonggi site (GW-22) was 0.0182 $day^{-1}$, half life of BTEX was 84 days, and thus 124 days (0.34 year) would be required to clean up this site. Mean of point attenuation rate of TPH in Kangwon site was 0.0088 $day^{-1}$, mean of half life was 257 days, and thus 462 days would be required to clean up the site. Mean of point attenuation rate of TPH in Gyeonggi site was 0.0387 $day^{-1}$, mean of half life was 55 days, and thus remediation time was calculated as 99 days.

경안천유역내 축산단지 인근 시설원예지역의 천층지하수 수질특성 (Groundwater Quality in the Shallow Aquifer at the Plastic Film Houses Area near Livestock Area in Kyongan River Basin)

  • 김진호;문광현;안승구
    • 한국토양환경학회지
    • /
    • 제5권3호
    • /
    • pp.77-85
    • /
    • 2001
  • 본 연구는 수도권내 팔당특별대책지역에 위치하서 비점오염원인 양돈축산단지와 시설원예단지가 집중적으로 분포된 경기도 용인시 포곡면에서 제 1 대수층 지하수의 수질과 오염특성, 그리고 이들의 시기별 변동특성을 구명하고자 98년 4월, 6월, 8월 등 총 3회에 걸쳐 31개의 시설원예지에서 관개용수로 사용하고 있는 관정을 대상으로 수행하였다. 조사대상지역의 수질특성 중 CO $D_{cr}$ 중간치는 6월(8.0mg/L) > 4월(4.4mg/L) > 8월(3.2mg/L)순이었으며, $NH_3$-N 중간치도 6월(0.21mg/L) > 4월(0.08mg/L) > 8월(0.04mg/L) 순으로 CO $D_{cr}$ 과 동일한 경향을 보였다. $NO_3$-N의 경우 조사시기별 중간치 농도의 변화는 거의 없었으며, 조사대상지점의 평균 28%가 농업용수 수질기준(20mg/L)을 초과하였다. 또한 황산염의 경우는 조사대상지점의 일부가 농작물피해한계를 초과하였으나, 그 외 수질성분들은 농업용수로 사용하기에는 적합한 수준이었다. 축산 및 시설원예지지역내 지하수를 농업용수로 사용시 수질기준과 농작물 피해기준을 고려한 적절한 수질관리가 필요할 것이다.

  • PDF

우리나라 논 관개용 지하수 수질 특성 (Characteristics of the Groundwater Quality for Paddy Fields in Korea)

  • 김진호;조광래;임수정;이경자;경기천;엄미정;김희권;김찬용;이영한;이신찬;윤순강
    • 한국환경농학회지
    • /
    • 제22권4호
    • /
    • pp.241-245
    • /
    • 2003
  • This study was carried out to evaluate the status of the groundwater quality for paddy fields irrigation in Korea. Water samples were collected at 130 sites throughout the country. Samples were collected at three seasons - April, July and October - in 2000. According to our survey, the groundwater was found to be suitable for irrigation purpose. Average EC was shown 0.286 dS/m. Nitrate-nitrogen and $Cl^-$ concentration was 5.6 mg/L, 32.95 mg/L which satisfied the Korean Standards for Irrigation Water. Nitrate-nitrogen concentration in each province was shown as following orders: Jeju (11.17 mg/L) > Chungnam (8.16 mg/L) > Gyeongbuk (6.64 mg/L) > Gyounggi (5.91 mg/L) > Chungnam (4.95 mg/L) > Gyeongnam (3.91 mg/L) > Jeonbuk (3.50 mg/L) > Jeonnam (3.27 mg/L) > Gangwon (2.91 mg/L). The concentration by sampling seasons were October (6.62 mg/L) > July (5.88 mg/L) > April (4.78 mg/L). As the soil of Jeju Province is usually derived from volcanic ash soils mainly used for upland drops, it may influence the nitrate-nitrogen concentration of groundwater. The amount of rainfall also influence the water quality. But the $COD_{Cr}$ were shown April (3.17 mg/L) > July (2.91 mg/L) > October (2.40 mg/L), it is highly related in the basal dose of organic matter fertilizers. This study demonstrated that groundwater quality was suitable for irrigation, but continuous monitoring is recommended for agricultural policy and developing OECD agricultural environment indicators.

GIS 공통 지표를 활용한 지하수 변화 통합 모델 제공 (Providing the combined models for groundwater changes using common indicators in GIS)

  • 사마네 함타;서유석
    • 한국수자원학회논문집
    • /
    • 제55권3호
    • /
    • pp.245-255
    • /
    • 2022
  • 수질 보호를 위한 정기 계획을 세우는 과정에서 다양한 지표를 이용해 수자원의 수질 추이를 평가하는 일이 필요하며 이는 수역 관리에서 널리 사용하는 방법이다. 본 연구에서는 1995년부터 2020년까지 이란 대수층의 수질 매개변수 자료를 수집, 검토하고, 통계적으로 검증하여 연도별 구획도를 만들었다. 이를 위해 지리정보체계(GIS), 거리 반비례 가중법(IDW), 방사 기저함수(RBF), 포괄 선형 보간법(GPI), 단순, 일반, 범용의 세 유형을 포함하는 Kriging과 Co-Kriging기법을 이용하였다. 이어 최소 불확실성과 최소 구획 오차에 ASE와 RMSE를 포함하는 두 값의 근접도를 더한 것을 최적 모델로 선택하였다. 마지막으로 각 매개변수에 대해 선택한 복합 모델을 Schuler와 Wilcox 지수와 조합하여 구획화했다. 이란의 지하 수자원에 대한 종합평가 결과는 수자원의 59%는 농업용수로, 39.86%는 음용수에 부적합한 등급으로 분류되어 이란 지하수 수질이 위기에 처해 있음을 보여주었다. 마지막으로 추출 결과를 검증하기 위해 지하 수질 지수(GWQI)로 수질의 공간 변화를 평가한 결과 이란의 대수층이 적은 수위변화에도 매우 민감하며 지하수 양도 매우 부족하다는 것을 확인할 수 있었다.

제주시 한천 저류지의 수질 특성 (Characteristics of water quality at Han stream retention ponds in Jeju City)

  • 김진근
    • 상하수도학회지
    • /
    • 제27권2호
    • /
    • pp.207-214
    • /
    • 2013
  • To evaluate characteristics of water quality in Jeju, a study was implemented for Han stream and retention ponds. Inflow water quality of retention ponds was heavily dependent on precedent rainfall, and no pesticide was detected due to the little artificial pollution sources. A smooth settling efficiency curve was noticed because heavy particles were already settled down in front of the retention pond. There were weak relationships between retention time and water quality, and this can be attributable to high concentration of pollutants influx at peak inflow. In addition, as Han stream retention pond has a role of groundwater recharge, inflow control based on water quality as well as quantity is needed to maximize pollutant removal at the retention ponds.

State Indicator of Water Quality for Surface Water and Groundwater in Agriculture

  • Kim, Min-Kyeong;Jung, Goo-Bok;Ro, An-Sung;Choi, Seung-Chul;Choi, Won-Il;Kim, Eun-Jeong;Lee, Jong-Eun;Yun, Yeo-Uk;Kim, Kab-Cheol;Ko, Do-Young;Kim, Byeong-Ho;Kim, Hyeon-Ji;Park, Sang-Jo;Lee, Seong-Tae;Heo, Jae-Young;Yang, Sang-Ho;Kang, Seong-Soo
    • 한국토양비료학회지
    • /
    • 제48권5호
    • /
    • pp.509-514
    • /
    • 2015
  • Indicators of environmental conditions qualitatively and quantitatively describe the state of the environment and natural resources, and the OECD (Organization for Economic Cooperation and Development) has initiated and suggested AEIs (Agri-Environmental Indicators) to assess trends over time of the effects of agriculture on the environment and the effectiveness and efficiency of agricultural and environmental policy measures since 1990's. This study aims to develop the state indicators of water quality for agricultural water, surface and groundwater, to evaluate the environmental impacts of agricultural activities and policies by qualifying the environmental levels of a nation. Status indicators were calculated according to the agricultural water quality standards of OECD and Korea, and their trends were analyzed over time. Particularly, nitrate ($NO_3{^-}$) status indicators of ground water in 2013 were significantly lower than the ones in 2000. Overall, the water quality indicators of surface water in 2013 were higher than the ones in 2012, except for pH and DO. The groundwater quality indicators in 2013 were lower than those of previous years. The optimal management indicators were calculated to assess agricultural surface water and groundwater quality. The findings of this study indicated that the state indicators could play a significant role to establish policies and procedures for managing and conserving water resources. This study also discussed water pollution caused by agricultural and industrial effluents.

Comparison of hydrochemical informations of groundwater obtained from two different underground storage systems

  • Lee, Jeonghoon;Kim, Jun-Mo;Chang, Ho-Wan
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 총회 및 춘계학술발표회
    • /
    • pp.110-113
    • /
    • 2002
  • Statistical- based, principal component analysis (PCA) was applied to chemical data from two underground storage systems containing LPG to assess the usefulness of such technique at the initial stage (Pyeongtaek) or middle stage (Ulsan) of hydrochemical studies. For the first case, both natural and anthropogenic contamination characterize regional groundwater. Saline water buffered by Namyang lake affects as a natural factor, whereas cement grouting influence as an artificial factor. For the second study area, contaminations due to operation of LPG caverns, such as disinfection activity and cement grouting effect, deteriorate groundwater quality. This study indicates that principal component analysis would be particularly useful for summarizing large data set for the purpose of subsurface characterization, assessing their vulnerability to contamination and protecting recharge zones.

  • PDF

Savitzky-Golay 필터와 미분을 활용한 LSTM 기반 지하수 수위 예측 모델의 성능 비교 (Performance Comparison of LSTM-Based Groundwater Level Prediction Model Using Savitzky-Golay Filter and Differential Method )

  • 송근산;송영진
    • 반도체디스플레이기술학회지
    • /
    • 제22권3호
    • /
    • pp.84-89
    • /
    • 2023
  • In water resource management, data prediction is performed using artificial intelligence, and companies, governments, and institutions continue to attempt to efficiently manage resources through this. LSTM is a model specialized for processing time series data, which can identify data patterns that change over time and has been attempted to predict groundwater level data. However, groundwater level data can cause sen-sor errors, missing values, or outliers, and these problems can degrade the performance of the LSTM model, and there is a need to improve data quality by processing them in the pretreatment stage. Therefore, in pre-dicting groundwater data, we will compare the LSTM model with the MSE and the model after normaliza-tion through distribution, and discuss the important process of analysis and data preprocessing according to the comparison results and changes in the results.

  • PDF

하수처리장 방류수를 이용한 인공함양 가능성 평가

  • 김병군;서인석;홍성택;김형수
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.257-260
    • /
    • 2002
  • The main purpose of this research is to find suitable treatment methods of wastewater effluent for artificial recharge. For this purpose, we search the effluent quality of wastewater treatment plant and possibility of additional filtration process. Particles ranged 2 ~ 5 ${\mu}{\textrm}{m}$ and 15~20 ${\mu}{\textrm}{m}$ in "T" WWTP(Waste Water Treatment Plant) effluent were relatively dominant. In dual-media filtration system operation, head-loss development of column 1 was about two times faster than column 2, and head-loss development within 5 cm from surface was very important factor in operation, Conclusively, for the stable filtration and running time of 1.5~2 day, influent turbidity must keep 5 NTU or below, and filtration system must operated at 280 m/day or below. After filtration of WWTP effluent, water quality reached satisfactory level. This water has potential of agricultural reusing, flushing water in building, recharging water to river or stream at dry season and artificial recharge of ground water.und water.

  • PDF