• Title/Summary/Keyword: groundwater movement

Search Result 132, Processing Time 0.021 seconds

Cause of Groundwater Yield Reduction in a Collector Well Considering Sediment's Composition and Hydrogeochemical Characteristics (지층 및 이화학 특성을 고려한 방사형 집수정의 취수량 감소 원인 분석)

  • Kim, Gyoo-Bum;Lee, Chi-Hyung;Oh, Dong-Hwan
    • The Journal of Engineering Geology
    • /
    • v.27 no.4
    • /
    • pp.439-449
    • /
    • 2017
  • The cause of yield reduction in a collector well, which is located in Anseong-cheon watershed in Kyunggi province, is studied by using aquifer sediments' composition and hydraulic conductivity near four horizontal wells, no. 1, no. 4, no. 6, and no. 7 wells. During test-pumping periods, groundwater yield is reduced with a trend of $12.4m^3/d/d$ at no. 1, $2.3m^3/d/d$ at no. 4, $24.4m^3/d/d$ at no. 6, and $187.3m^3/d/d$ at no. 7 and no. 7 well shows the biggest reduction. The sediments along no. 7 horizontal well have low hydraulic conductivity and high coefficient of uniformity ($C_u$), and a deviation of $C_u$ along the well is also large. This characteristics can bring the fine particles' movement and make the openings filled. Additionally, high iron ($Fe^{2+}$) content results in a precipitation of iron hydroxides during pumping or injection and they can produce a clogging in sediments. In the future study, the analysis of physical and hydrochemical changes through a long-term pumping procedure will give a more exact interpretation for the cause of yield reduction.

Implementation of User Interface and GeoSensor based Traveling Type Sub-Observation Prototype System for Monitoring of Groundwater (지하수 모니터링을 위한 GeoSensor 기반의 이동식 보조관측망 프로토타입 시스템 및 사용자 인터페이스 구현)

  • Kim, Kyung-Jong;Jung, Se-Hoon;Sim, Chun-Bo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.1
    • /
    • pp.183-192
    • /
    • 2012
  • Although underground water resource has relatively less pollution rate compared with surface water, its recovery faces many difficulties due to poor management. Our country monitors underground water to manage it effectively through auxiliary observation network for underground water. In this paper, we suggest water-well auto measure system based on Geosensor for business efficiency increase of water-well management and realtime monitering. In this system is consist of user GUI(Graphic User Interface) composed with water-well information and movement sub-observation network prototype system composed with GPS(Global Positioning System) and wireless sensor node such as water temperature, water level, electrical conductivity. In this system is using the light of the sun for self-power, variety water-well information collected wireless sensor node was a wireless transmitting/receiving a using CDMA(Code Division Multiple Access) module. Also, for promote with user ease, user GUI express that water-well collected in GIS(Geographic Information System) map. For performance evaluation of the proposed system, we perform experiment using sensing information through designed sub-observation network. And we was proved superiority of the proposed system through qualitative evaluation with other paper.

Stability Analysis Techniques of Bracing Structure in the Hard Clay Ground According to the Variation of the Groundwater Level at the Trench Excavation (경질점성토 지반에서 Trench 굴착시 지하수위 변동에 따른 가설구조체 안정해석 기법)

  • Heo, Chang-Hwan;Seo, Sung-Tag;Kim, Hee-Duck;Jee, Hong-Kee
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.3 no.2 s.9
    • /
    • pp.99-110
    • /
    • 2003
  • In this study, lightening material weight and normalizing structure of preventing system of landslide soil-rock in trench excavation was tried with focusing in safety construction availability and workability. In other words, risk estimate, safety management method investigation, applicability of bracing material and mechanical stability of bracing structure was studied. From these result, structural stability and structural analysis of light weight bracing structure was carried out with common structural analysis program, for examining movement mechanism of bracing structure and normalization of standard. The result are summarized as following. (1) Mechanical ability of bracing members and soil pressure parameter acting to member for ensuring mechanical propriety of bracing structural and useful of new material considering soil mechanics boundary were proposed. Also theory and method of analysis of bracing structural were proposed. (2) As a result of the structure analysis of geographical profile for light pannel used FRP as hard clay mechanical characteristics(bending moment, shear force, axial force) of panel were changed according to groundwater level and it is proved that the result of mechanical analysis is within allowable stress. Thus, light pannel is available for bracing structure in trench excavation.

Moved of Applied Fertilizers through Volcanic Ash Soils in a Lysimeter Experiment (Lysimeter를 이용한 시비비료의 화산회토 토양중 이동에 관한 연구)

  • 강봉균;조남기
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.3
    • /
    • pp.3-12
    • /
    • 2001
  • This study conducted to Investigate the movement of fertilized nutrients in a volcanic ash soil in Jeju using by the pressure-vacuum soil water sampler. The percolated water to measure the ion concentration of leachates was taken from a lysimeter at depths of 20, 40, 60, 80, 100 and 120 cm in the soil in where a corn and potato were cultivated as a preceding and succeeding crop, respectively. Fertilizers of N-$P_2$O$_{5}$-$K_2$O were applied at the rate of 36-30-30 kg $10a^{-1}$ for the corn and 28-22-24 kg $10a^{-1}$ for the potato prior to planting of both crops. The highest concentrations of Cl , $NO_3$-N, $Ca^{+2}$ and $K^+$ in percolates were showed at 20cm and 40cm in soil depth at one month after fertilizing, and then gradually moved and reduced into below soil depths. At 5.5 months after fertilization, the concentrations in all soil depths were similar with the value of before fertilization. At depth of 120cm, the concentration of NO$_3$-N and the other cations in leachate was highest 1 to 1.5 months after fertilization. pH in percolated water was negatively correlated with NO$_3$-N concentration while the concentration of $NO_3$-N showed positive correlation between Cl, $Ca^{+2}$ and $Mg^{+2}$ concentrations. This result indicated that those cations can be leached out by accompanied with $NO_3$-N.

  • PDF

Assessment of External Radiation Dose for Workers in Domestic Water Treatment Facility According to the Working Type (국내 수처리시설 종사자 작업유형에 따른 외부피폭방사선량 평가)

  • Seong Hun Jeon;Seong Yeon Lee;Hyeok Jae Kim;Min Seong Kim;Kwang Pyo Kim
    • Journal of Radiation Industry
    • /
    • v.17 no.2
    • /
    • pp.151-160
    • /
    • 2023
  • The International Atomic Energy Agency (IAEA) proposes 11 industries that handle Naturally Occurring Radioactive Material (NORM) that are considered to need management. A water treatment facility is one of the above industries that takes in groundwater and produces drinking water through a water treatment process. Groundwater can accumulate natural radionuclides such as uranium and thorium in raw water by contacting rocks or soil containing natural radionuclides. Therefore, there is a possibility that workers in water treatment facilities will be exposed due to the accumulation of natural radionuclides in the water treatment process. The goal of this study is to evaluate the external radiation dose according to the working type of workers in water treatment facilities. In order to achieve the above goal, the study was conducted by dividing it into 1) analysis of the exposure environment, 2) measurement of the external radiation dose rate 3) evaluation of the external radiation dose. In the stage of analyzing the exposure environment, major processes that are expected to occur significantly were derived. In the measurement stage of the external radiation dose rate, a map of the external radiation dose rate was prepared by measuring the spatial radiation dose rate in major processes. Through this, detailed measurement points were selected considering the movement of workers. In the external radiation dose evaluation stage, the external radiation dose was evaluated based on the previously derived external radiation dose rate and working time. As a result of measuring the external radiation dose rate at the detailed points of water treatment facilities A to C, it was 1.90×10-1 to 3.75×100 μSv h-1, and the external radiation dose was analyzed as 3.27×10-3 to 9.85×10-2 mSv y-1. The maximum external radiation dose appeared during the disinfection and cleaning of activated carbon at facility B, and it is judged that natural radionuclides were concentrated in activated carbon. It was found that the external radiation dose of workers in the water treatment facility was less than 1mSv y-1, which is about 10% of the dose limit for the public. As a result of this study, it was found that the radiological effect of external radiation dose of domestic water treatment facility workers was insignificant. The results are expected to contribute as background data to present optimized safety management measures for domestic NORM industries in the future.

Determination of porosity and effective porosity of saturated porous media using a permittivity method in the laboratory (유전율법을 이용한 다공질 매질의 공극률 및 유효공극률의 측정에 관한 연구)

  • 김만일;니시가끼마코토
    • The Journal of Engineering Geology
    • /
    • v.13 no.4
    • /
    • pp.419-428
    • /
    • 2003
  • In order to evaluate groundwater movement and the infiltration of contaminants, such as petroleum products, the determination of porosity and effective porosity is very important. Porosity and effective porosity are important physical parameters that determine the transfer and movement of water and solutes in porous media. Various methods of determining these parameters have been developed, with varying degrees of accuracy and applicability. Most of the existing methods produce static results. They do not produce instantaneous and real time of porosity and effective porosity in a porous media. In this study, we used a new permittivity method called Frequency Domain Reflectometry with Vector analyzer (FDR-V) to determine the porosity and effective porosity of some sand samples in the laboratory. The advantage of the FDR-V method is that it instantaneously determines the temporal variation of dielectric constants of porous media. Then, the porosity and the effective porosity of porous media are computed using well established empirical equations. Results obtained from the FDR-V method compared favorably with results from other permittivity methods such as gravimetric, injection and replacement tests. The ratio of effective porosity to porosity was 85 - 92 %, when FDR-V was used. This value compared favourably with 90 %, which has been usually quoted in previous studies. Considering the convenience and its applicability, the EDR-V permittivity holds a great potential in porous media and contaminant transport studies.

Analysis of Groundwater Level Reduction Effects to Burial Angle of Slope Reinforcement Materials (비탈면 보강재의 매설각에 따른 지하수위 저감효과 분석)

  • Hyeonjun Yoon;Sungyeol Lee;Wonjin Baek;Jaemo Kang;Jinyoung Kim;Hwabin, Ko
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.8
    • /
    • pp.5-11
    • /
    • 2023
  • Due to frequent occurrences of concentrated heavy rainfall caused by abnormal climate conditions in recent years, collapses of steep slopes have been occurring frequently due to surface erosion and increased pore water pressure. Various methods are being applied to prevent slope collapses, such as increasing the resistance to movement and reducing pore water pressure. Research on these methods has been consistently conducted as they provide an efficient response to slope collapses by satisfying both the conditions of resistance to movement and pore water pressure simultaneously. Therefore, in this study, we propose an upward slope reinforcement method by burying drainage materials with an upward slope inclination, instead of the conventional horizontal application. This approach aims to satisfy both slope reinforcement and drainage functions effectively, offering a comprehensive solution for slope stabilization. Furthermore, to determine the optimal burial angle that exhibits the most effective reinforcement and drainage effects of the proposed method, we investigated the reinforcement and drainage effects under conditions where the horizontal drainage materials were set at angles ranging from 0° to 60° in increments of 10° on a representative cross-section. Additionally, indoor model experiments were conducted under the conditions of 40°, which showed the most outstanding drainage effect, and 20°, which exhibited the highest safety factor, to validate the numerical analysis results. The results showed that the burial angle of 40° exhibits a relatively higher drainage effect as with the numerical analysis results, while the angle of 20° results in inadequate drainage and observed slope collapse.

Effective Diffusion Coefficient in the Porous Media (다공성 미디아에 있어서 유효확산계수)

  • Jeehyeong Khim
    • Journal of Korea Soil Environment Society
    • /
    • v.1 no.2
    • /
    • pp.83-90
    • /
    • 1996
  • A diffusion process is often the main mechanism of soil gas/vapor movement in the vadose zone. The diffusion coefficients in the porous soil media are different from those in the free air phase by the reduction of available area for diffusion, tortuous diffusion path and variable cross section area along the diffusion path. To take account those effects of the diffusion process in the porous media, usually the terms of effective diffusion coefficient and tortuosity are have been used. However, as there are many differents definitions for the tortuosity, when the term of tortuosity is used, it is necessary to examine it throughly. Moreover, there are many different equations for the effective diffusion coefficient according to the investigators and the differences in the values of effective diffusion coefficients between the equations are not insignificant, the selection of the equation should be done with caution. In this paper, the different definitions of effective diffusion coefficient are examined and discussed. As well as definitions, the lots of availabe models for the diffusion coefficient in terms of porosities are compared. Also, the constrictiviy which explains the effect of cross sectional area change over the diffusion path was discussed.

  • PDF

Borehole radar survey to explore limestone cavities for the construction of a highway bridge

  • Kim Jung-Ho;Cho Seong-Jun;Yi Myeong-Jong
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.1
    • /
    • pp.80-87
    • /
    • 2004
  • During excavation work for the construction of a highway bridge in a limestone area in Korea, several cavities were found, and construction work was stopped temporarily. Cavities under the bridge piers might seriously threaten the safety of the planned bridge, because they could lead to excessive subsidence and differential settlement of the pier foundations. In order to establish a method for reinforcement of the pier foundations, borehole radar reflection and tomography surveys were carried out, to locate cavities under the planned pier locations and to determine their sizes where they exist. Since travel time data from the crosshole radar survey showed anisotropy, we applied an anisotropic tomography inversion algorithm assuming heterogeneous elliptic anisotropy, in order to reconstruct three kinds of tomograms: tomograms of maximum and minimum velocities, and of the direction of the symmetry axis. The distribution of maximum velocity matched core logging results better than that of the minimum velocity. The degree of anisotropy, defined by the normalized difference between maximum and minimum velocities, was helpful in deciding whether an anomalous zone in a tomogram was a cavity or not. By careful examination of borehole radar reflection and tomography images, the spatial distributions of cavities were delineated, and most of them were interpreted as being filled with clay and/or water. All the interpretation results implied that two faults imaged clearly by a DC resistivity survey were among the most important factors controlling the groundwater movement in the survey area, and therefore were closely related to the development of cavities. The method of reinforcement of the pier foundations was based on the interpretation results, and the results were confirmed when construction work was resumed.

Adsorption and Leaching of cis and frans-Permethrin in the Soil (토양 중 cis 및 trans-Permethrin의 흡착 및 침출)

  • Sam Edward Feagley
    • Journal of Environmental Science International
    • /
    • v.4 no.4
    • /
    • pp.379-386
    • /
    • 1995
  • Permethrin [3-phenox yben zyl(1RS)-cis,tans-3-(2,2-dichloroviny1)-2,2- dimethylcyclopropane carboxylate] insecticides were selected to study adsorption and leaching potentials related to pollution on Commerce silty clay loam soil near Baton Rouge, Louisiana, USA. GLC-ECD chromatogram of permethrin included 32.5 % of cis-pemehin and 67.4 % of trans-permethrin. Extraction efficiencies of is and trmu-pemetun were 92.5 % and 92.3 % in fortified water, respectively and 85.9 % and 88.8 % in fortified soil, respectively. At a 1:10 moi]/water ratio,the Koc values for sis and fan isomers of permethrin were 938 and 877, respectively. Leaching of permethrin was evaluated in soil columns$(5.4 cm i.d. \times 26 cm length)$. Total recoveries of the permethrin applied to the soil column were $84.5\pm3.1%$. When the soil columns were leached with three pore volumes of water, the distributions of cis-permethrin leached were 6.10 % and 0.07 % of amount applied in the untreated zone soil and leachate water, respectively Trans-pemethrin distributions were 5.20 % in the untreated zone soil and 0.05 % in leachate water. Cis and trans-pemethrin was strongly adsorbed to soil. The results of the study showed the strong relationship between adsorption and leaching. Cis and trans-permethrin to be leached into the groundwater in soils with shallow aquifers were suggested a low leaching potential.

  • PDF