• 제목/요약/키워드: grounding resistance

검색결과 246건 처리시간 0.026초

진단용 방사선발생장치의 검사기준을 적용한 동물병원의 방사선 안전관리 (The Radiation Safety Management in the Animal Hospital Using Inspection Standard of Diagnosis Radiation System)

  • 김상우;임재동;한동균;성열훈
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.73-80
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using inspection standard of X-ray generator for diagnosis. The surveys for inspection standard system, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The inspection standard included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. The surveys of equipment condition and safety supervision used one-on-one interview with 5 points measurement. As a result, 44.44% of reproducibility of dose exposure was proper, 81.25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test. The 100mA electric capacity of X-ray generator for diagnosis was popular with 44.44%, and its 55.56% was purchased used equipment. Monthly average of less than 50 times (61.11%) was top frequency in use, and no animal clinic had a thermo-luminescence dosimeter(TLD). The 16 animal clinics with radiation safety zone and 2 without radiation safety zone were appeared.

가변주파수 및 임펄스 전류를 이용한 과도접지임피던스 분석 (An Analysis Method for the Transient Ground Impedance Using Variable Frequency and Lightning Impulse Current)

  • 엄주홍;조성철;이태형
    • 조명전기설비학회논문지
    • /
    • 제22권6호
    • /
    • pp.100-108
    • /
    • 2008
  • 접지전극의 형태, 크기, 재질 및 임펄스전류의 형상에 따라 변화하는 과도접지임피던스는 접지시스템의 성능에 중요한 영향을 미친다. 본 논문은 기존의 실효임펄스임피던스가 실제 과도접지임피던스를 얼마나 효과적으로 나타내고 있는가에 대한 분석과 보다 효과적인 과도접지임피던스 평가방법에 대하여 실험적인 결과를 제시하였다. 실험에 사용된 접지전극은 저항성분과 인덕턴스를 포함한 모의 접지전극과 1[m] 탄소접지봉, 9[m] 일반동봉 그리고 40[m] 매설지선이며, 가변주파수 전류와 임펄스전류에 의한 접지임피던스를 각각 측정하였다. 각각의 값을 비교 했을 때 기존의 실효임펄스임피던스의 값보다는 전압의 최대 값과 전류의 최대 값을 이용하여 과도접지임피던스를 구한 임피던스 값($Z_1$)이 등가주파수에 해당하는 가변주파수 전류에 의해 구해진 접지임피던스에 근접함을 확인하였다.

배전계통에 사용되는 봉형 접지전극의 접지 임피던스 특성 분석 (Ground Impedance Characteristics Analysis of a Rod Type Grounding Electrode used for Distribution Systems)

  • 김경철;진성은;이주홍;김유준;최종기;백남웅
    • 조명전기설비학회논문지
    • /
    • 제19권6호
    • /
    • pp.67-74
    • /
    • 2005
  • 접지 시스템은 전기설비의 기준 전위점을 확보할 뿐만 아니라, 대지에 낮은 저항으로 고장 전류를 흐르게 한다. 고장전류는 넓은 범위의 주파수를 포함하기 때문에 접지의 성능을 평가하기 위해선 주파수에 대한 함수로 접지임피던스에 대한 특성의 분석이 필요하다. 본 논문에서는 상용화된 접지봉(매직봉)의 접지임피던스를 0[Hz]에서 100[kHz] 범위까지 측정하였고, 접지임피던스를 회로 모델과 전달함수 모델로 구하여 측정된 값과 비교 검토하였다.

외부 전자파에 의한 LAN 케이블의 유도전압 (Induced Voltages on LAN Cables Due to Incident Electromagnetic Fields)

  • 주재철;박범준;김종국;이현영;임계재;박동철
    • 한국전자파학회논문지
    • /
    • 제10권5호
    • /
    • pp.719-726
    • /
    • 1999
  • 임의의 방향에서 입사하는 외부 전자파와 다중 전송선로와의 결합 특성을 해석하기 위해 다중 전송선 방 정식을 FDTD 기법으로 전개하고 선로에 유도되는 전압을 시율레이션하였다. 테스트 선로로는 Ethernet 방식 의 고속 LAN 구축시 사용되는 UTP Category 5 케이블과 알루미늄 호일로 차폐된 STP Category 5 케이블 을 사용하였다. TEM 생을 이용하여 유도전압을 측정한 실험결과와 시율레이션 결과를 비교하여 잘 일치함 을 확인하였다. 또한 차폐된 STP Category 5에 대해 차폐 호일의 접지상태 및 접지저항의 변화에 따른 차폐 효과를 비교한 결과, 차폐 호일의 양단을 모두 접지하고 접지저항을 작게 할 때 차폐 효과가 가장 크게 나타 났다

  • PDF

지중방전현상에 의한 접지시스템의 써지 임피던스의 저감 (The Decreasing of Surge Impedance of Grounding System by using Discharge)

  • 정재기;강지원;양병모;김홍필
    • 조명전기설비학회논문지
    • /
    • 제12권4호
    • /
    • pp.55-61
    • /
    • 1998
  • 일반적으로 접지시스템에서 접지저항계산은 저주파수의 전원이 대지에 인가될 때 발새외는 대지전위상승을 측정하여 계산한다. 그러나 뇌격과 써지 엄펄스와 같은 고주파수에 해당하는 전원에 대해서는 현재의 접지 시스템에서 고려하고 있지 않기 때문에 전기설비에 매우 큰 영향을 미칠 우려가 있다. 그래서 이 논문에 서는 뇌격이 전극봉에 인가되었을 때 발생되는 접지 임피던스의 과도현상을 실험하였다. 그리고 이 실험 결과는 이론적 해석과 잘 일치하였으며 지중방전현상이 임펄스 임피던스 저감에 영향올 미친다는 사실을 확인 할 수 있었다.

  • PDF

345kV 혼합송전선로에서 재폐로가 절연설계에 미치는 영향 (Effects of Reclosing for Insulation Coordination in 345kV Combined Transmission Lines)

  • 이종범;정채균;임광식;강지원
    • 전기학회논문지
    • /
    • 제59권5호
    • /
    • pp.847-853
    • /
    • 2010
  • This paper describes switching surge analysis for reclosing decision in 345kV combined transmission line with XLPE power cable. Reclosing operation should be decided based on the detailed technical analysis in combined transmission line because this line includes power cable section which is week on insulation. Insulation of power cable can be breakdown at the week point in case of reclosing moment. Therefore the detailed analysis has to be carried out by considering several conditions such as length ratio of power cable section, arrestor, inserting resistance, charging rate, grounding resistance, etc.. On the other hand sheath voltage on IJ(Insulated Joint) is analyzed to check dangerous condition on cable cover. Analysis is performed by EMTP/ATP. Analysis results show that reclosing can be operated as the single line-to-ground fault occurs on overhead line in 345kV combined transmission line, if the inserting resistance is considered before the operation of main circuit breaker.

22.9kV 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석 (Analysis on the Induced Lightning Shielding Effect According to the Neutral Wire Installation Structure of a 22.9kV Distribution Line)

  • 김점식;김도영;박용범
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.191-196
    • /
    • 2010
  • The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed $50\Omega$ and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9kV distribution line in order to present a new 22.9kV distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9kV distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.

고주파수 영역에서 심매설 접지전극의 접지임피던스 (Ground impedance of deeply driven rod in high frequency domain)

  • 이복희;이태형;이수봉;정현욱;정동철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.247-250
    • /
    • 2004
  • A ground resistance is a good index of performance in a grounding system, but it does not reflect the performance in transient states. Recently long vertical ground rods in urban areas are often installed. But because of the inductance of long ground rods the ground impedance at high frequency might be greater than its resistance at low frequency. In this paper, a ground impedance of deeply driven ground rod has been measured in the frequency range from 10 kHz to 50 MHz. As a result, the ground impedances of a deeply driven ground rods are almost constant at the frequency range less than 100 kHz. However at high frequency the ground impedance showed the strong frequency dependance.

  • PDF

345kV급 가공송전선로와 GIL이 연계된 혼합송전계통에서 개폐과전압 해석 및 검토 (Switching Surge Analysis and Evaluation in Combined Transmission System with 345kV GIL)

  • 장화윤;이종범;김용갑;장태인
    • 전기학회논문지
    • /
    • 제60권10호
    • /
    • pp.1811-1816
    • /
    • 2011
  • This paper describes switching surge analysis for reclosing decision in 345kV combined transmission line with GIL. Reclosing operation should be decided based on the detailed technical analysis in combined transmission line because this line includes power cable section which is week on insulation. Insulation of power cable can be breakdown at the week point in case of reclosing moment. Therefore the detailed analysis has to be carried out by considering several conditions such as charging rate, inserting resistance, arrester, length ratio of power cable section, grounding resistance, etc. Analysis is performed by EMTP/ATP.

혼합송전선로에서 고저항 지락사고시 케이블 과도현상 해석 및 전력케이블 시스 접지저항에 따른 CCPU 과도특성 모의 (Modeling and Transient Analysis of Cable in Combined Transmission Line with HIF and Analysis of Transient Characterstic in CCPU of Uderground Cable)

  • 정채균;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.446-448
    • /
    • 2000
  • This paper discribes the modeling and transient analysis of cable in combined transmission line under high impedance fault(HIF). And also, transient characterstic analyzed on cable covering protection unit(CCPU) is presented. Modeling of the combined transmission line is established in PSCAD/EMTDC V3. The required data to analyze the transient phenomena is given from the actual system. The results show the HIF modeling in cable, fault current according to the value of fault resistance. And also when the value and method of grounding resistance is changed in CCPU, simulation results are presented.

  • PDF