• 제목/요약/키워드: ground water

검색결과 3,603건 처리시간 0.032초

지하수위에 따른 철도사면의 안정성 변화 (The Variation of Slope Stability by Ground Water Level in Railway Lines)

  • 김현기;신민호;신지수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.789-795
    • /
    • 2008
  • Slope stability is affected by various factors. For safety management of slopes, monitoring systems have been widely constructed along railway lines. The representative data from the systems are variations of ground profile such like ground water level and pore water pressure etc. and direct displacement measured by ground clinometer and tension wire sensor. Slopes are mainly effected by rainfall and rainfall causes the decrease of factor of safety(FOS). Because FOS varies linearly by the variation of ground water level and pore pressure, it has a weak point that could not define the time and proper warning sign to secure the safety of the train. In this study, alternative of FOS such as reliability index and probability of failure is applied to slope stability analysis introducing the reliability concept. FOS, reliability index, probability of failure and velocity of probability of failure of the slopes by variation of ground water level are investigated for setting up the specification of safety management of slopes. By executing case study of a slope(ILLO-IMSUNGLI), it is showed to be applied to specification of safety management.

  • PDF

경기북부지역 지하수의 지역별 미량무기물질 함유실태 조사연구 (A survey on the content of inorganic materials in ground-water of Northern Gyeonggi area)

  • 오조교;손진석;배용수;정은희;박진호;황선민;정연훈
    • 환경위생공학
    • /
    • 제19권1호
    • /
    • pp.8-16
    • /
    • 2004
  • Ground water samples were collected from residential, green" industrial, landfill and mining area and analyzed for 23 inorganics from March to October in 2002. The results are as follows; 1. The detection frequencies of inorganic materials such as As, Ba, B, Mo, Ca, Mg, Al, Cu, Fe, Mn, Zn, Na, K were 7.2∼77.1% which showed that these inorganics were detected in many ground waters. 2. The detection frequencies of 7 inorganics(Cd, Cr, Ph, Se, Sb, Be, Tl) were commonly low at ranging from 0.42 to 2.5%. These inorganics were contained in ground water partially. 3. Three inorganics such as Hg, Ni, Ag were not detected in any ground-water samples. 4. Compared to the other areas, ground water samples from landfill area contained greater concentration in many inorgainics and then showed higher levels in industral, residential, mining and green area in order. 5. Compared to noted concentrations of bottled water, inorganic minerals including Ca, Mg, Na, K related to taste were fluent in target samples. The results showed that the average concentrations of Mg, Na, K were 4.0 mg/l, 14.7 mg/l, 1.5 mg/l respectively. 6. The concentrations of inorganics such as Sb, Ba, Mo, Be, Tl, K in some ground water samples exceeded the water quality standards of WHO, the US and UK. Especially, Ba, Mo, K also showed relatively high detection frequencies so these inorganics need to be considered as analytes in Korea Drinking Water Regulation in further study.

강우특성을 고려한 불포화 풍화잔류토 사면의 안정성 해석 (Stability Analysis of a Slope in Unsaturated Weathered Residual Soil Considering the Rainfall Characteristics)

  • 이강일;장용채;김태훈;정연인
    • 한국지반환경공학회 논문집
    • /
    • 제7권2호
    • /
    • pp.5-14
    • /
    • 2006
  • 풍화토나 풍화암 지반의 경우 집중호우에 의한 사면붕괴는 주로 지표면부근 2.0m 이내에서 발생되며, 강우발생 전에 사면 내 지하수위가 높지 않다면 강우가 지하수위 상승에 미치는 영향은 크지 않은 것으로 보고되고 있다. 그러나 국내 사면설계에 적용되고 있는 우기시 지하수위 조건은 강우에 의해 지하수위가 지표면까지 상승하는 것으로 보고 있어, 사면의 활동 파괴면이 지표부근 보다는 사면 심부에서 발생되는 것으로 검토 되고 있다. 본 연구는 사면 안정에 주된 영향을 미치는 지하수위 조건의 적정성 여부를 검토하기 위하여 서울지역 30년 평균일강우량을 적용하여 실제 우기시 지하수위 상승 및 사면안정성을 검토하였다. 그 결과 지하수위 상승량은 사면 높이의 6.0~41.0%로 나타나 현재 통용되고 있는 우기시 지하수위 적용 기준이 과대평가되고 있음을 알 수 있었다.

  • PDF

지중열교환기 성능 향상에 관한 연구 (A Study on Improving the Efficiency of Ground Heat Exchanger)

  • 김욱중;이공훈;김민수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.3142-3147
    • /
    • 2008
  • A simple transient simulation of ground source heat pump system was carried out to investigate the effects of ground thermal conductivity on its performance. The TRNSYS code with a simple water to water heat pump model was used to compare the COP variation of the system. A new ground heat exchanger called by semi-closed loop was proposed and constructed in the real site. The effective thermal conductivity was measured using the test equipment developed by according to the line source model. The simulation results showed that highly efficient thermal conductivity of the grout material could increase the performance of the heat pump system very well. And the new ground heat exchanger showed the increased effective thermal conductivity as the penetration water flow rate(PWFR) was increased. Therefore, the performance improvement of the heat pump system using the proposed ground heat exchanger can be expected.

  • PDF

서울 S지역에서 발생한 영아 메트헤모글로빈혈증 1례의 원인구명을 위한 역학조사 (Epidemiologic Investigation to Identify the Cause of an Infant Methemoglobinemia)

  • 김영열;최보율;박항배;김민영;여인학
    • Journal of Preventive Medicine and Public Health
    • /
    • 제26권2호
    • /
    • pp.192-201
    • /
    • 1993
  • Epidemiologic investigation was conducted on January, 1993 in Seoul to identify the cause of an infant methemoglobinemia. Field investigation of the area of outbreak, survey of household and family members, analysis of ground water, and blood tests of involved family members were performed. Following results were obtained On analyzing the quality of the ground water on patient's household high levels of nitrate was found indicating contamination of water as the cause of a methemoglobinemia outbreak. On analysing the quality of the ground waters on seven other places within the neighborhood five were contaminated by nitrate in concentration that exceeded the permissible limit implying presence nearby source of contamination. Sources of contamination were thought to be originating from human waste in conventional bathroom facilities, chicken manure used in nearby orchards and plant fields or fertilizers. But the results of water analysis with presence of bacteria or E.coli, concentration of potassium, phosphate and the past history of diarrhea among family members, chicken manure suggested the most possible source of contamination. To evaluate the health status of members in the neighborhood past history was reviewed revealing no prior existence of patient with cyanosis and 65 people in the neighborhood had normal levels of methemoglobin concentration in their blood. Conclusively, the ground water on patient's household was contaminated with nitrate and despite provision of adequate water supply, family members of the patient along with their distrust in the water supply system had used ground water as their source of drinking water resulting of methemoglobinemia. Many suburban area of Seoul and country side thought to be having similar problems concerning contaminated ground water supply and dormant outbreak of patients as a result of the drinking of the contaminated water. Epidemiologic investigation and water analysis of ground waters are advised.

  • PDF

부산 지역 약수 및 지하수의 규산성 규소 (Silicate- silicious of Spring Water and Ground Water in Pusan Area)

  • 김용관;하봉석
    • 한국환경보건학회지
    • /
    • 제18권1호
    • /
    • pp.34-38
    • /
    • 1992
  • This study was carried out to investigate silicate-silicious in spring water and ground water. Samples were collected from 23 Stations of spring water and 2 Stations of ground water from August 1985 to July 1990 in Pusan area. Range and mean value of silicate-silicious of spring water and ground water were lower 2.12~22.70mg/l, 8.78mg/l, 13.90~19.05mg/l, 16.23mg/l than the criterion for drinking water as 50rng/l. The concentration of silicate-silicious had a great influence on precipitation, therefore it in summer was higher than in winter. The estimated regression line between chloride ion(x) and silicate-silicious(y) of the sampled water was y=19.366-0.604x(r=-0.7111).

  • PDF

지열원 열펌프 시스템의 에너지 생산량 모니터링 신뢰도 향상 방안 연구 (A Study on the Monitoring Methods for Energy Production in Ground Source Heat Pump System)

  • 강신형;이광호;도성록;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권2호
    • /
    • pp.10-16
    • /
    • 2019
  • In this study, the present regulation of heat metering for the ground source heat pump was investigated. The ground source heat pump has been adopting the heat metering system used in the district heating system for estimating the heating and cooling energy production amount. The accuracy of the present heat metering systems for a water to water ground source heat pump is low, because the system for district heating has a relatively high temperature range comparing with the ground source heat pump operating conditions. Even though the heat amount for the building side should be measured, the heat absorption and extraction amount from or to the ground was measured for the water to air ground source heat pump due to the difficulty of estimating the air side heating and cooling capacity in the present regulation. It is highly recommended to validate the heat metering system to have reliability for the ground source heat pump and develop the system to be applicable water to air ground source heat pump.

그라우팅 재료가 지중 유효열전도도에 미치는 영향 (Effect of Grouting Materials on Ground Effective Thermal Conductivity)

  • 손병후
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3371-3376
    • /
    • 2007
  • The design of a ground-source heat pump system includes specifications for a ground loop heat exchanger where the heat transfer rate depends on the thermal conductivity of the ground. To evaluate this heat transfer property, in-situ thermal response tests on four vertical test boreholes with different grouting materials were conducted by adding a monitored amount of heat to water over various test lengths. By measuring the water temperatures entering and exiting the loop, water flow rate, and heat load, effective thermal conductivity values of the ground were determined. The effect of increasing thermal conductivity of grouting materials from 0.82 to 1.05 W/m$^{\circ}C$ resulted in overall increases in effective ground thermal conductivity by 25.8% to 69.5%.

  • PDF

지표수 및 지하수중 불소 함량에 관한 연구 (A Study on Fluoride Contents in Surface and Ground Waters in Korea.)

  • Kim, Sung-Ja;Noh, Pyung-Ui;Bak, Young-Soo
    • 한국환경보건학회지
    • /
    • 제3권1호
    • /
    • pp.9-12
    • /
    • 1976
  • A study was performed to find out the fluoride contents in surface and ground waters from June, 1973 to July, 1974. Water samples were collected from 53 surface and ground water sources. The results are as follows: 1. Out of 53 samples, the ground water of Hwaengsung had the highest fluoride contents (1.6 mg/l) and 13 samples did not. have fluoride at all. 2. The waters from Yoju (ground), Chongnung (ground) Hwaengsung (ground) and Namyang (ground) had optimum fluoride level (0.6~1.7mg/l) for the prevention of dental caries. 3. The ground waters had more fluoride contents than surface waters and the waters of coastal areas had less fluoride contents than those of inland. 4. The waters of Kangwon province had the most fluoride contents (mean 0.57mg/l) and the waters of Cheju do had the least fluoride contents (mean 0.06 mg/l)

  • PDF

다변량 통계 분석 및 질량 균형법을 이용한 제주도 지하수의 수질 요소 분리

  • 고동찬;고경석;김용제;이승구
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.450-452
    • /
    • 2004
  • Using factor analysis and bivariate comparisons of major components in ground water, three geochemical processes were identified as controlling factors of ground water chemistry; 1) natural mineralization by water rock interactions, 2) effect of seawater which includes salinization by seawater near seashores and deposition of sea salt, and 3) nitrate contamination by N fertilization. Contribution of rainfall was also estimated from the measured composition of wet deposition. The geochemical processes were separated using total alkalinity as an indicator for natural mineralization, Cl for effect of seawater, and nitrate for N fertilization. Relatively high correlation of major components with nitrate suggests that nitrification of nitrogenous fertilizers significantly affects ground water chemistry. Total cations derived from nitrate sources have good linearity for nitrate in equivalent basis with a slope of 1.8, which is a mean of proton production coefficients in nitrification of two major compounds in nitrogenous fertilizers, ammonium and urea. Contribution of nitrate sources to base cations, Cl, and SO$_4$ in ground water was determined considering maximum contribution of natural mineralization to estimate a threshold of the effect of N fertilization for ground water chemistry, which shows W fertilization has a greatest effect than any other processes in ground water with nitrate concentration greater than 50 mg/L for Ca, Mg, Na and with concentration greater than 30 mg/L for Cl and SO$_4$.

  • PDF