Abstract
In this study, the present regulation of heat metering for the ground source heat pump was investigated. The ground source heat pump has been adopting the heat metering system used in the district heating system for estimating the heating and cooling energy production amount. The accuracy of the present heat metering systems for a water to water ground source heat pump is low, because the system for district heating has a relatively high temperature range comparing with the ground source heat pump operating conditions. Even though the heat amount for the building side should be measured, the heat absorption and extraction amount from or to the ground was measured for the water to air ground source heat pump due to the difficulty of estimating the air side heating and cooling capacity in the present regulation. It is highly recommended to validate the heat metering system to have reliability for the ground source heat pump and develop the system to be applicable water to air ground source heat pump.
Keywords
Ground source heat pump; Energy production; Mornitoring regulation; Test standards; Heat meter;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 MOTIE, KEA, 2016, New & renewable energy white paper, Energy, Korea Energy Agency, Yongin, Korea.
2 Kang, H. J., Lee, H. S., and Jang, M. H., 2018, A study on the reliability of district heat measuing devices for ground source heat pump systems, Transactions of the KSGEE, Vol. 14, No. 1, pp. 1-7.
3 Korea Energy Agency, 2013, A study on the distribution plan of renewable heat obligation (RHO) for building, Report of Korea Energy Agency, Yongin, Korea.
4 Zheng, B., Xu, J., Ni, T., and Li, M. 2015, Geothermal energy utilization trends from a technological paradigm perspective. Renewable Energy, Vol. 77, pp. 430-441.   DOI
5 Lee, C., Park, M., Nguyen, T. B., Sohn, B., Choi, J. M., and Choi, H., 2012, Performance evaluation of closed-loop vertical ground heat exchangers by conducting in-situ thermal response tests. Renewable Energy, Vol. 42, pp. 77-83.   DOI
6 Nam, Y. and Oh, J., 2014, Study on the characteristic of heat exchange for vertical geothermal system using the numerical simulation, Journal of the Korean Solar Energy Society, Vol. 34, No. 2, pp. 66-72.   DOI
7 MOTIE, 2015, Preparation of Standard for Heat Meter for New & Renewable Facility, Final Report of Ministry of Trade, Industry and Energy, Sejong-si, Korea.
8 Ministry of Land, Infrastructure and Transport, 2015, Regulation about Residential Building Construction, Ministry of Land, Infrastructure and Transport, Sejongsi, Korea.
9 Lee, W., Kang, E., Lee, E., and Shin, U., 2014, A study on the calculation of thermal consumption unit of apartment, Korean Journal of Air-conditioning and Refrigeration Engineering, Vol. 26, No. 8, pp. 388-393.   DOI
10 Chirstopher, J. W., Hao, L., and Saffa, B. R. 2012, Comparatative performance of 'U-tube' and 'coaxial' loop designs for use with a ground source heat pump, Applied Thermal Engineering, Vol. 37, pp. 190-195.   DOI
11 Qian, H., 2014, Modeling the interactions between the performance of ground sourece heat pumps and soil temperature variations, Energy for Sustainable Development, Vol 23, pp. 115-121.   DOI
12 PEM Korea, 2015, Development and feasible test of GLHX with spiral shape HDPE pipe, Ministry of Knowledge Economy Report, Korea.
13 Kang, S. and Choi, J. M., Analysis on the performance evaluation trends of heat pumps and the test standards of a geothermal heat pump in Korea, Transactions of the KSGEE, Vol. 14, No. 1, pp. 1-7.
14 KEMCO, 2014, New and renewable energy statistics 2014, Report of Korea Energy Management Corporation, KEMCO, Yongin, Korea.
15 KATS, 2015, Water-to-water ground source heat pump unit; KS B 8292, Korea Agency for Technology and Standards (KATS), Chungcheongbuk-do, Korea.
16 KATS, 2016, Water-to-air ground source heat pump unit; KS B 8293, Korea Agency for Technology and Standards (KATS), Chungcheongbuk-do, Korea.
17 KATS, 2016, Water-to-air ground source multi-heat pump unit; KS B 8294, Korea Agency for Technology and Standards (KATS), Chungcheongbuk-do, Korea.
18 MOTIE, 2018, Standards of support, installation, and management for new and renewable energy system, Report of Korea Ministry of Trade, Industry and Energy Announcement, 2018-1, Korea.
19 Korean Standard Association, 2005, Heat meters-Part 1 : General requirements, KS B 50075-1, Korea Industrial Standards, Seoul, Korea.
20 MOTIE, 2015, Technical standard of integrating heat meter, Report of Korea Ministry of Trade, Industry and Energy Announcement, 2014-281, Korea.
21 Park, S. Bu, Lee, S., Choi, J., and Choi, J. M., 2015, The study on the structure and performance of heat pump calorimeter, Transactions of the KSGEE, Vol. 11, No. 4, pp. 7-13.
22 Aikins, K. A. and Choi, J. M., 2013, Issues to improve ground source heat pump units in Korea: Refrigerant application and hot water generation, Journal of Renewable and Sustainable Energy, Vol. 5, Paper No. 052002, pp. 1-11.
23 European Committee for Standardization, 2007, Air conditioners, liquid chilling packages and heat pumps with electrical compressors for space heating and cooling-Testing and rating conditions, EU, NFEN 14511.