• 제목/요약/키워드: ground treatment

검색결과 862건 처리시간 0.027초

Improvement of Plating Characteristics Between Nickel and PEEK by Plasma Treatment and Chemical Etching

  • Lee, Hye W.;Lee, Jong K.;Park, Ki Y.
    • Corrosion Science and Technology
    • /
    • 제8권1호
    • /
    • pp.15-20
    • /
    • 2009
  • Surface of PEEK(poly-ether-ether-ketone) was modified by chemical etching, plasma treatment and mechanical grinding to improve the plating adhesion. The plating characteristics of these samples were studied by the contact angle, plating thickness, gloss and adhesion. Chemical etching and plasma treatment increased wettability, adhesion and gloss. The contact angle of as-received PEEK was $61^{\circ}$. The contact angles of chemical etched, plasma treated or both were improved to the range of $15{\sim}33^{\circ}$. In the case of electroless plating, the thickest layer without blister was $1.6{\mu}m$. The adhesion strengths by chemical etching, plasma treatment or both chemical etching and plasma treatment were $75kgf/cm^2$, $102kgf/cm^2$, $113kgf/cm^2$, respectively, comparing to the $24kgf/cm^2$ of as-received. In the case of mechanically ground PEEKs, the adhesion strengths were higher than those unground, with the sacrifice of surface gloss. The gloss of untreated PEEK were greater than mechanically ground PEEKs. Plating thickness increased linearly with the plating times.

An Application of High-Power Ultrasound to Rubber Recycling

  • Hong, Chang-Kook;Isayev, A.I.
    • Elastomers and Composites
    • /
    • 제38권2호
    • /
    • pp.103-121
    • /
    • 2003
  • The application of powerful ultrasound to rubber recycling is a very recent field of study. An ultrasonic field creates high frequency extension-contraction stresses by acoustic cavitation. The breakdown of rubber network occurs primarily around pulsating cavities due to the highest level of strain produced by high-power ultrasound. Stronger reductions of cross-link density were observed at a higher pressure, indicating an important role of pressure during ultrasonic recycling. Visible bubbles were observed during ultrasonic treatment as a proof of acoustic cavitation. Shearing effect has a significant influence on improving the efficiency of ultrasonic treatment. After the ultrasonic treatment, the cross-link densities of NR/SBR blends were lower than those of NR and SBR due to the reduced degree of unsaturation and chemical reactions. Carbon black fillers increase the probability of bond scission during ultrasonic treatment, due to the restricted mobility. The mechanical properties of ground tire rubber (GRT)/HDPE blends were improved by ultrasonic treatment and dynamic revulcanization. Ultrasonic treatment of GRT in the presence of HDPE matrix was found to give better mechanical properties due to the chemical reactions between rubber and plastic phases.

압력도수터널 콘크리트 라이닝 구조 계산시 외수압 처리에 관한 연구 (A study on the treatment of external water pressure for the water pressure tunnel at the structural analysis of concrete lining)

  • 이현섭;이영준;서승우;황영철
    • 한국터널지하공간학회 논문집
    • /
    • 제17권6호
    • /
    • pp.653-664
    • /
    • 2015
  • 압력도수터널 콘크리트 라이닝 구조계산시 암반의 이완하중, 내수압, 외수압, 건조수축, 그라우팅압 등 다양한 하중조건을 고려하는데, 아직까지 국내에는 압력도수터널에 대한 콘크리트 라이닝 구조해석을 위한 설계기준 및 체계적인 매뉴얼이 없으므로 설계자에 따라 다르게 적용되고 있는 실정이다. 특히, 도수터널은 외수압을 저감시키기 위해 Weep Hole을 설치하는 경우도 있는데, Weep Hole 설치로 인해 많은 문제점이 야기될 수도 있으므로 Weep Hole을 설치하지 않을 시 외수압 처리에 대한 합리적인 접근 방법이 필요하다. 따라서, 본 논문에서는 압력도수터널 콘크리트 라이닝 구조 계산시 외수압 처리에 대해 기존 설계사례 및 문헌 등을 분석하여 합리적이고 적절한 설계개념에 대하여 서술하였다.

방파제 축조공사의 Centrifuge 모델링과 수치해석 (Centrifuge Modeling and Numerical Analysis on Breakwater Construction)

  • 유남재;김동건;윤대희
    • 산업기술연구
    • /
    • 제31권B호
    • /
    • pp.81-90
    • /
    • 2011
  • Centrifuge modeling and numerical analysis on works of breakwater construction were performed to investigate the behavior of caisson type of breakwater and foundation treated with the method of DCM (Deep Cement Mixing) under the condition of wave action in field. In centrifuge modeling, construction sequence of breakwater caisson such as preparation of ground, treatment of DCM, installation of rubble mound, placement of breakwater caisson and lateral loading on the breakwater due to wave action were reconstructed. Lateral movement of model breakwater and ground reaction in the vertical direction were monitored during test. Stress concentration ratio between the untreated ground and the treated ground with DCM was evaluated from measurement of vertical stresses on each ground. Numerical analysis with the software of PLAXIS was carried to compare with Results of centrifuge model test. It was found that stability of model breakwater was maintained during stage of construction and the compared results about stress concentration ratio were in relatively good agreements.

  • PDF

해외 사례를 통한 지상조업 품질 개선방안 연구 (Improvement of Ground Handling Service Quality through Overseas Cases)

  • 최유진;강용규;박규선
    • 한국항공운항학회지
    • /
    • 제27권4호
    • /
    • pp.65-72
    • /
    • 2019
  • There is concern about the increased risk of accidents from manual investments due to ground handling service operators, aging equipment and manpower shortages. Therefore, it is necessary to improve the quality of ground treatment services and safety management at the airport. Therefore, this study analyzed the domestic and overseas ground operation status and the license handling procedure of aircraft handling business. In addition, a case study on the evaluation system of international organizations examined the applicability of the certification body to the Korean situation. It is practical in that it provides policy implications for improving the quality of groundwork not covered in previous studies. This is expected to improve the constitution, improve quality, improve airport operations, and operate safely.

High Performance Liquid Chromatography (HPLC) Detection of Malonaldehydethiobarbituric Acid (MA-TBA) Complex in Ground Pork

  • Whang, Key
    • Preventive Nutrition and Food Science
    • /
    • 제4권3호
    • /
    • pp.171-174
    • /
    • 1999
  • For monitoring lipid oxidation development in cooked ground pork during refrigerationm, malonaldehydethiobarbituric acid(MA-TBA) contents were measured using high performance liquid chromatography(HPLC). As the oxidation proceeded during refergeration, TBA-reaction substances(TBARS) absorbances increased and the corresponding HPLC peak areas also increased proportationately. The correlation coefficient between the HPLC peak areas and MA-TBA absorbance were 0.9979. The treatemtn of cetrimide, an ion pairing agent, gave a complete resolution of the MA-TBA complex and the butanol extraction of the complex increased its recovery by 37.8%. Both cetrimide treatment and butanol extraction are essential steps for analyzing MA-TBA complex in ground pork wiht HPLC. A reliable and specific measurement of NA-TBA in ground pork was successfully performed using HPLC.

  • PDF

우리 나라의 하수도현황과 전망 (State of Swerage Systems and Prospects in Korea)

  • 김갑수
    • 환경위생공학
    • /
    • 제8권2호
    • /
    • pp.65-84
    • /
    • 1993
  • This study reviewed the current status and problems of sewerage system in Korea and then proposed possible methods to correct the problems. Also, evaluation of future development in sewerage system is included. It can be summarized as follows : 1. Investment in sewerage system is relatively low . 0.23% of GNP, Considering that the investment portion is 0.35% in OECD and 0.63% in Japan, it should be increased further. 2. The reasons wily the investment in sewerage system is low can be ' (1) Low priority is given to the investment in sewerage system. Local government builds and operates its own wastewater treatment plant. Local government as well as residents prefer to invest their money in roadwork, housing and parks to in wastewater treatment facilities because of greater investment effects. (2) Besides capital investment, more maintenance cost is needed for sewerage system. Proper operation of wastewater treatment facilities requires a well-trained operator. Because of public conception that operation of wastewater treatment facility is a dirty job, it is difficult to find a well-trained operator. (3) It is difficult to estimate the effect of sewerage system (4) Cost required to build and maintain wastewater treatment facility should be paid by people, who benefit from the facility. People to benefit are sometimes different from people to pay. 3. Advanced treatment is necessary to protect the bay aura and raw water source as well as to prevent eutrophication of lakes and ponds. 4. Wastewater treatment facility were mainly build in big cities during the decade of 1980. Followings should be solved first to expand the facilities. (1) Rapid repair and construction of sewer. (2) Technical development of wastewater treatment . Prevention of efficient and economical wastewater . Development of efficient and economical wastewater treatment techniques . Development of high-efficiency treatment using bioreactor . Reuse of wastewater treatment plant effluent (3) Sludge treatment and disposal . Composting of sludge cakes . Development of techniques to reduce the volume of sludge cake : incineration and reuse of sludge ash and slag. (4) Utilization of wastewater treatment facilities . Construction of community parks or sports families(ie, on the tops of the covered aeration tanks and sedimention tanks) Construction of wastewater treatment facilities under ground and of parking facilities and community parks above ground. (5) Education of wastewater treatment personal.

  • PDF

지하수관개지역에서의 수도재배기간중 시비량의 변화에 따른 영양물질 수지 분석 (Water and Nutrient Balance during rice cropping period using difference fertilization paddy plot in ground water irrigation region)

  • 황하선;윤춘경
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.451-455
    • /
    • 2001
  • This study was performed to examine water and nutrient balance during rice cropping period using difference fertilization paddy plot in ground water irrigation region. The experimental rice paddy consist of three plot, Treatment of Excess fertilization(TEF) and Treatment of Standard Fertilization(TSF) and Treatment of Reduce Fertilization(TRF). As result, input amount to rice paddy was almost rainfall and output was direct runoff through drainage. nutrient input amount was upper paddy in case COD and fertilization in case Total nitrogen and total phosphorus, and output was drainage in all nutrient.

  • PDF

Hydration and time-dependent rheology changes of cement paste containing ground fly ash

  • Chen, Wei;Huang, Hao
    • Computers and Concrete
    • /
    • 제11권1호
    • /
    • pp.39-49
    • /
    • 2013
  • The use of ground fly ash in concrete can increase the risk of slump loss due to the drastic surface change of the particles after the grinding treatment and the accelerated reaction compared to the untreated ash. This study is aimed at the early age hydration and time-dependent rheology changes of cement paste containing ground fly ash. An original fly ash is ground into different fineness and the hydration of cement paste containing the ground fly ash is monitored with the ultrasound propagation method. The zeta potentials of the solid particles are measured and the changes of rheological parameters of the cement pastes with time are analyzed with a rheometer. A particle packing model is used to probe packing of the solid particles. The results show that the early age hydration of the paste is strongly promoted by replacing Portland cement with fly ash up to 30 percent (by mass), causing increase of the yield stress of the paste. The viscosity of a paste containing ground fly ash is lower than that containing the untreated ash, which is explained by the denser packing of the solid particles.

침출수 처리 응용 펄스전원 시스템 (Pulsed Power System for Leachate Treatment Application)

  • 장성록;안석호;류홍제;임근희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.246-247
    • /
    • 2010
  • This paper deals with the water treatment of the leachate from sewage filled ground by a pulsed power technology. Leachate from sewage filled ground should be treated below regulation level of COD in order to prevent environmental pollution and usually treated by a chemical method. Among the pollutants mixed in the leachate, chemical compounds of benzene series are known to be difficult to break down, and need to use high cost treat methods. The treatment of the benzene compounds by high power pulsed power supply was studied. For the high-rate, cost-effective treatment of leachate, pulsed power supply should have high repetition rates and require switching devices of long lifetime. In order to meet the demands of the above condition, pulsed power generator based on semiconductor switches using IGBTs as primary switches were developed. The experimental results verified that benzene compounds can be treated effectively by high voltage electric pulses, and this fact indicates that the treatment method by pulsed power source is a promising substitute.

  • PDF