다중방전 경로를 이용한 편상접지체의 접지저항 및 전류특성 (Grounding Resistance and Current Characteristics of the Planar Earth Structure using Multiple Discharge Paths)

  • 김영선;김동민;이기식
    • 전기학회논문지
    • /
    • 제65권9호
    • /
    • pp.1564-1570
    • /
    • 2016
  • This study proposes a newly modified form of existing ground electrodes in order to secure trust of grounding system for large current caused by a stroke of lightning. Proposed planar earth structure has a several needle electrodes around a circular rod and 4 plane electrodes in all directions. The plane electrodes are fused with the insulator on the linear rod, so that they're electrically isolated. The concept is to increase the discharge amount of earth structure using multiple discharge paths like needle and plane electrodes. To check the discharge efficiency of the suggested scheme, the discharge currents are compared with typically used two kinds of ground rods. To ensure accuracy in the measurement of the discharge current, the same material was used for the comparison model. Also, the ground resistance are simulated by CDEGS commercial software and the results are compared with measured data. Based on this kind of experimental study, the suggested ground rod can be used when designing a ground system or when constructing a ground system at the site.

접지임피던스 측정시 보조전극의 배치 기준 연구 (Placement Standard Research of Auxiliary Probes when Measuring Ground Impedance)

  • 김동우;길형준;김동욱;이기연;문현욱
    • 전기학회논문지
    • /
    • 제60권10호
    • /
    • pp.1984-1991
    • /
    • 2011
  • Among ground impedance measurement methods, the fall-of-potential method is the most thorough and reliable method. In the fall-of-potential method, ground electrode and auxiliary probes are placed in a straight line, and then, auxiliary potential probe is moved away from the ground electrode. The point at which plotted resistance curve flattens out is taken as right position of auxiliary potential probe. However, in some cases, it is hard to place ground electrode and auxiliary probes in a straight line. Therefore, we provided alternative placement method in this research. The method can be easily applicable to placing auxiliary probes. Also, this paper analyzed and compared ground impedance measurement standards of large grounding systems. Based on the analysis, practical measurement method using an earth tester was proposed. The proposed methods presented in this paper will be useful when determining locations of auxiliary probes in alternative positions, and the methods can be applied practically and easily.

가변주파수 인버터를 이용한 접지임피던스 측정 (Measurement of Impedance of the Grounding Grid using Variable Frequency Inverter)

  • 이복희;엄주홍;김교운
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.303-306
    • /
    • 2002
  • This paper presents a novel method for measuring the ground impedance in grounding systems. A square wave current was injected to the main grounding grid through auxiliary electrode, and the test current and ground potential rise(GPR) were measured using the band-pass filter. Ground impedance was calculated from the sinusoidal waveforms of the test current and GPR in frequency range of 20~2100Hz. Also the resistance and reactance component of ground impedance were analyzed.

  • PDF

수직형 지열 열교환기(BHE)의 열성능 측정에 관한 실험적 연구 (An Experimental Study on the Thermal Performance Measurement of Vertical Borehole Heat Exchanger(BHE))

  • 임경빈;이상훈;성낙원;이창희
    • 대한기계학회논문집B
    • /
    • 제30권8호
    • /
    • pp.764-771
    • /
    • 2006
  • Knowledge of ground thermal properties is most important for the proper design of large BHE(borehole heat exchanger) systems. Thermal response tests with mobile measurement devices were first introduced in Sweden and USA in 1995. Thermal response tests have so far been used primarily for in insitu determination of design data for BHE systems, but also for evaluation of grout material, heat exchanger types and ground water effects. The main purpose has been to determine insitu values of effective ground thermal conductivity, including the effect of ground-water flow and natural convection in the boreholes. Test rig is set up on a small trailer, and contains a circulation pump, a heater, temperature sensors and a data logger for recording the temperature data. A constant heat power is injected into the borehole through the pipe system of test rig and the resulting temperature change in the borehole is recorded. The recorded temperature data are analysed with a line-source model, which gives the effective insitu values of rock thermal conductivity and borehole thermal resistance.

변전소 접지설계를 위한 대지고유저항의 측정과 해석 (Measurement and Analysis of Earth Resistivity for the Substation Grounding Design)

  • 한풍;김재이;최종기;정길조;김정부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.807-812
    • /
    • 1997
  • For an equivalent uniform soil model to multiple-layered soil structure, ground depth, which is used in the calculation of equivalent resistivity, should be varied according to the size of grounding area. In case of 150 kV substation grounding design, 15 m of ground depth has been used and 25 m for 345 kV, But applying these ground depths can lead to errors in grounding resistance calculation, and these errors are coming from the poor representation of those depths to real soil resistivities. In this paper, the soil resistivity measurement techniques by Wenner method and grounding resistance calculation results by computer simulation were presented. Case studies contain the area from 3,000 to $30,000\;m^2$ and measuring space from of m to $100{\sim}250\;m$, Based of the computation results, 50 m, 60 m and 80 m of ground depth for less than 30, 40 and 70 m of equivalent hemispherical radius were proposed respectively.

  • PDF

대지전위 실측에 의한 접지성능 평가 (Estimation of Earth Performance by Ground Potential Measurement)

  • 이원영;김재훈;김주한;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.51-53
    • /
    • 2005
  • Grounding systems are responsible rot the safe operation of a power system whetehr power system fault occures or not, their performance guarantees equipmet protection and personnel safety by limited the ground potential rise and touch voltages as well as step voltages under ground fault condition. therefore, it is necessary to measure the ground resistance frequently for checing the performance of grounding system. In order to verigy the designed grounding measurement system feasibility, two comparison verifications, which are the ground resistnace measurements using the designed system on power service and off power service, are carried out for the same substation.

  • PDF

광대역 접지임피던스 측정기의 설계 및 제작 (Design and Fabrication of a Wideband Ground Impedance Meter)

  • 길경석;박대원;장운용;한주섭;길형준
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.793-797
    • /
    • 2010
  • The basic performance of the ground system is evaluated as the ground resistance by applying low frequency current below 1 kHz. However, characteristics of the ground system should be analyzed by high frequency current up to 1 MHz since transient currents having a few hundred kHz component flow during a line-to-ground fault and/or a lightning strike. This paper deals with the design and fabrication of a wideband ground impedance meter (WGIM) which measures the impedance of ground systems in ranges from 65 Hz to 1.28 MHz. Also, a noise elimination algorithm using a digital bandpass filter is proposed. The maximum error of the WGIM is 4.91% in the measurement frequency range.

접지전류 분류계수 및 전위강하곡선법을 이용한 운전 중인 변전소의 접지저항 측정 방법에 관한 연구 (A Study on Grounding Resistance Measurement of Power Supplying Substation using Grounding Current Division Factor and FOP Profile Method)

  • 안용호;최종기;김용학;한정열;이유진;한병성
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.100-107
    • /
    • 2011
  • Since transmission and distribution neutral wires are connected with a substation grounding grid, it is very difficult to measure grounding resistance of isolated substation grounding grid after the substation is energized. It is impractical to isolate the grounding grid from other parallel connections such as distribution line neutrals and overhead ground wires for grounding resistance measurement only. In this paper, we proposed and demonstrated a novel measurement method of grounding resistance of isolated substation grounding grid. For this method, grounding current division factor and conventional FOP(Fall-Of-Potential) profiles were measured at power supplying 154[kV] substation. The obtained FOP profile was processed with the measured grounding current division factor to produce the grounding resistance of isolated grounding grid. Simulated FOP profile agreed well with the measured one showing the validity of the proposed method.

스파이럴 볼트 변형률계를 이용한 연약지반기초 및 암반사면 거동 계측 (Measurement of Soft Ground Foundation and Rock Slope Behavior Using Spiral Bolt Strain Gauge)

  • 강성승;히라타 아츠오;정승회;이우람;제동광;김대현
    • 터널과지하공간
    • /
    • 제20권2호
    • /
    • pp.105-111
    • /
    • 2010
  • 본 연구에서는 연약지반기초 및 암반사면 거동 계측 도구로서 스파이럴 볼트 변형률계의 적용 가능성을 살펴보고자 한다. 이 변형률계가 지중에 설치되었을 때, 지반에 대한 인발 저항성이 높아 지반 보강용으로 적용될 수 있을 뿐만 아니라, 유연성의 특징을 가지고 있기 때문에 지반의 거동 상태를 파악하는데 유용하게 이용될 수 있다. 연약지반기초에 대한 스파이럴 볼트의 변형률 계측결과, 변형률 측정 초기에는 안정한 상태를 보이다가 400일이 경과한 시점에서는 스파이럴 볼트 변형률계의 윗부분과 중간부분에서 큰 변화가 관찰되었다. 이러한 변화는 동일한 시기에 강수량 증가와 함께 빈번하게 발생한 진도 1~2의 지진에 의한 영향으로 지반이 이완되어 야기한 것으로 분석된다. 암반사면에 대한 스파이럴 볼트의 변형률 계측결과, 측정시작일로부터 50일 동안에 안정한 상태를 보였으며 50~160일 기간에는 매설길이 4.2 m 지점(P6)의 변형률 게이지에서 가장 큰 변형률을 보였다. 그러나 P6 변형률 게이지를 제외한 나머지 게이지는 특이한 변화를 보이지 않았다. 스파이럴 볼트 변형률계의 측정결과를 종합적으로 살펴보면 측정대상인 연약지반기초와 암반사면은 안정적인 것으로 판단된다. 본 연구에서 소개하는 스파이럴 볼트 변형률계는 연약지반기초 및 암반사면 거동의 모니터링과 동시에 대상지반의 보강에 적용될 수 있을 것으로 사료된다.

샌드파일 주변지반에서 초기 방사방향 압축에 의한 압밀특성 연구 (A Study on Consolidation Characteristics by Considering the Initial Radial Compression at Sand Pile Adjacent Ground)

  • 천병식;여유현
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.649-656
    • /
    • 2000
  • Consolidation of the ground surrounding the sand piles is delayed by well resistance and smear effect. This study is executed to understand the factors that affect the characteristics of consolidation. This was accomplished by utilizing the estimated and measured values of the soil properties through the monitoring of the ground surrounding the sand piles. When it is assumed that the horizontal coefficient is equal to the vertical coefficient of consolidation, the estimated values is exceedingly similar to the measured values. The properties of the initially disturbed soil by the sand pile installation seemed to improve through the process of consolidation with the passage of time. From the results of the analysis of the settlement measurement, the measured values occurred about 60~90% of the predicted values. Considering the initial radical compression deformation, according to the theory of cavity expansion, the difference between the two appears to be in good agreement. In this study, to understand the behavioral characteristics of the ground surrounding the sand piles requires estimation through considering the initial radial compression as well as smear effect of the soil disturbance and well resistance.

  • PDF