An Experimental Study on the Thermal Performance Measurement of Vertical Borehole Heat Exchanger(BHE)

수직형 지열 열교환기(BHE)의 열성능 측정에 관한 실험적 연구

  • 임경빈 (한밭대학교 기계설계공학과) ;
  • 이상훈 (한밭대학교 기계설계공학과) ;
  • 성낙원 (한양대학교 대학원 기계공학과) ;
  • 이창희 (한양대학교 기계공학과)
  • Published : 2006.08.01

Abstract

Knowledge of ground thermal properties is most important for the proper design of large BHE(borehole heat exchanger) systems. Thermal response tests with mobile measurement devices were first introduced in Sweden and USA in 1995. Thermal response tests have so far been used primarily for in insitu determination of design data for BHE systems, but also for evaluation of grout material, heat exchanger types and ground water effects. The main purpose has been to determine insitu values of effective ground thermal conductivity, including the effect of ground-water flow and natural convection in the boreholes. Test rig is set up on a small trailer, and contains a circulation pump, a heater, temperature sensors and a data logger for recording the temperature data. A constant heat power is injected into the borehole through the pipe system of test rig and the resulting temperature change in the borehole is recorded. The recorded temperature data are analysed with a line-source model, which gives the effective insitu values of rock thermal conductivity and borehole thermal resistance.

Keywords

References

  1. Kavanaugh, S. P. and Rafferty, K., 1997, 'Ground-source Heat Pumps ; Design of Geothermal Systems for Commercial and Industrial Buildings,' ASHRE, USA
  2. Eklof, C. and Gehlin, S., 1996, 'TED ; A Mobile Equipment for Thermal Response Test,' Master of Science Thesis, Lulea University of Technology, Sweden
  3. Mands, E. and Sanner, B., 2000, 'InSitu-determination of Underground Thermal Parameters,' Int. SUMMER SCHOOL on Direct Application of Geothermal Energy, Giessen, Germany, pp. 1-10
  4. Gehlin, S., 2002, 'Thermal Response Test Method Development and Evaluation,' Doctor thesis, Lulea University of Technology, Sweden
  5. Mogensen, P., 1983, 'Fluid Duct Wall Heat Transfer in Duct System Heat Storage,' Proc. Int. Conf. On Subsurface Heat Storage in Theory and Practice, Stockholm, Sweden, pp. 652-657
  6. Austin, W. A., 1998, 'Development of an In-situ System for Measuring Ground Thermal Properties,' Master of Science Thesis, Oklahoma State University, USA
  7. Witte, H., van Gelder, GJ. and Spitler, J.D., 2002, 'In Situ Measurement of Ground Thermal Conductivity,' The Dutch Perspective. ASHRAE Transactions, Vol. 108, No.1, pp. 263-272
  8. Skouby, A., 1998, 'Thermal Conductivity Testing - Proper Engineering + Thermally Enhanced Grout = GeoExchange Savings,' The Source, Vol. 11, No. 6, p. 4,5
  9. Spitler, J., Rees, S. and Yavuzturk, C., 1999, 'More Comments In-situ Bore Thermal Conductivity Testing,' The Source, Vol. 3, No.4, pp. 3-10
  10. Smith, M. D., 1999, 'Comment on In-situ Borehole Thermal Conductivity Testing,' The Source, IGSHP Newsletter, Vol. 12, No.1, pp. 4-6

Cited by

  1. Feasibility Study of High-Efficiency Ground Heat Exchanger using Double U-tube through a Real-Scale Experiment vol.17, pp.4, 2017, https://doi.org/10.12813/kieae.2017.17.4.033