• Title/Summary/Keyword: ground power supply

Search Result 198, Processing Time 0.027 seconds

Low power-high performance embedded SRAM circuit techniques with enhanced array ground potential (어레이 접지전압 조정에 의한 저전력, 고성능 내장형 SRAM 회로 기술)

  • 정경아;손일헌
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.2
    • /
    • pp.36-47
    • /
    • 1998
  • Low power circuit techniques have been developed to realize the highest possible performance of embedded SRAM at 1V power supply with$0.5\mu\textrm{m}$ single threshold CMOS technology in which the unbalance between NMOS and PMOS threshold voltages is utilized to optimize the low power CMOS IC design. To achieve the best trade-off between the transistor drivability and the subthreshold current increase, the ground potential of memory array is raised to suppressthe subthreshold current. The problems of lower cellstability and bit-line dealy increase due to the enhanced array ground potential are evaluated to be controlled within the allowable range by careful circuit design. 160MHz, 128kb embedded SRAM with 3.4ns access time is demonstrated with the power consumption of 14.8mW in active $21.4{mu}W$ in standby mode at 1V power supply.

  • PDF

Power Supply System with Real-time Posture Sensing Capability for Mobile Robot (이동로봇의 실시간 자세 감지 기능을 갖는 전력공급 시스템)

  • Jin Sang-Yun;Yi Soo-Yeong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.3
    • /
    • pp.289-293
    • /
    • 2006
  • In this paper, we developed a ground power supply system for a mobile robot moving in the constrained region. By using an external scan circuit through the electrodes, it is also possible to detect the absolute position and heading angle of the robot without any additional position sensors. Since the heavy weighted-battery for electric power and the expensive absolute position sensors are not necessary to the robot by using for proposed system, the mobile robot system becomes cost-effective and dynamically fast.

Development of Onboard Power Supply Device for Precision Guided Kit (정밀유도 비행체 탑재용 전원공급장치 개발)

  • Park, Deok-Bae;Kim, Hyung-Shin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.209-214
    • /
    • 2008
  • A precision guided kit is a GPS/INS guided range extension system to improve the accuracy and availability of existing dumb bombs. The PSD(power supply device) installed in the GPS guided kit supplies electrical power to all electrical loads in the kit. In this paper, design process and test results of the PSD have been presented. Additionally, the performance results of the PSD during actual ground and flight tests have been described.

Optimization of protection System on the Railway High Voltage power System (철도 고압배전계통의 보호시스템 최적화 방안 연구)

  • 조웅기;창상훈;한성호;김왕곤
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.989-994
    • /
    • 2002
  • In case the fault occurs in railway high voltage power supply network, protective relaying system must selectively detect 1 wire ground fault of grounding or non-grounding system. And this study presents railway high voltage power supply system model using PSCAD/EMTDC Vet 3.08 for circuit analysis and fault studies. In this paper, we propose protection method of non-grounding system of railway high voltage power supply system. The result shows its usefulness.

  • PDF

Dynamic Voltage Compensator using Series and Shunt Inverters (직.병렬 인버터를 이용한 동적전압보상기)

  • Park, Deok-Hui;Lee, Jun-Gi;Han, Byeong-Mun;So, Yong-Cheol;Kim, Hyeon-U
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.11
    • /
    • pp.655-662
    • /
    • 1999
  • This paper describes controller design and simulation-model development of a dynamic voltage compensator using series and shunt inverters. The control system was designed using PI controller and vector relationship between the supply voltage and load voltage. A simulation model with EMTP was developed to analyze performance of the controller and the whole system. The simulation and experiment results confirm that the dynamic compensator can restore the load voltage under the fault of the distribution system, such as single-line-ground fault, three-line-to-ground fault, and line-to-line fault.

  • PDF

Phase-Locked Loop with Leakage and Power/Ground Noise Compensation in 32nm Technology

  • Kim, Kyung-Ki;Kim, Yong-Bin;Lee, Young-Jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.4
    • /
    • pp.241-246
    • /
    • 2007
  • This paper presents two novel compensation circuits for leakage current and power supply noise (PSN) in phase locked loop (PLL) using a nanometer CMOS technology. The leakage compensation circuit reduces the leakage current of the charge pump circuit and the PSN compensation circuit decreases the effect of power supply variation on the output frequency of VCO. The PLL design is based on a 32nm predictive CMOS technology and uses a 0.9 V power supply voltage. The simulation results show that the proposed PLL achieves 88% jitter reduction at 440 MHz output frequency compared to the PLL without leakage compensator and its output frequency drift is little to 20% power supply voltage variations. The PLL has an output frequency range of 40 $M{\sim}725$ MHz with a multiplication range of 1-1023, and the RMS and peak-to-peak jitter are 5psec and 42.7 psec, respectively.

Ground Deformation Evaluation during Vertical Shaft Construction through Digital Image Analysis

  • Woo, Sang-Kyun;Woo, Sang Inn;Kim, Joonyoung;Chu, Inyeop
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.2
    • /
    • pp.285-293
    • /
    • 2021
  • The construction of underground structures such as power supply lines, communication lines, utility tunnels has significantly increased worldwide for improving urban aesthetics ensuring citizen safety, and efficient use of underground space. Those underground structures are usually constructed along with vertical cylindrical shafts to facilitate their construction and maintenance. When constructing a vertical shaft through the open-cut method, the walls are mostly designed to be flexible, allowing a certain level of displacement. The earth pressure applied to the flexible walls acts as an external force and its accurate estimation is essential for reasonable and economical structure design. The earth pressure applied to the flexible wall is closely interrelated to the displacement of the surrounding ground. This study simulated stepwise excavation for constructing a cylindrical vertical shaft through a centrifugal model experiment. One quadrant of the axisymmetric vertical shaft and the ground were modeled, and ground excavation was simulated by shrinking the vertical shaft. The deformation occurring on the entire ground during the excavation was continuously evaluated through digital image analysis. The digital image analysis evaluated complex ground deformation which varied with wall displacement, distance from the wall, and ground depth. When the ground deformation data accumulate through the method used in this study, they can be used for developing shaft wall models in future for analyzing the earth pressure acting on them.

Design and Fabrication of High Frequency Ground Impedance Measuring System for Assessment of Grounding System for Lightning Protection (낙뢰 보호용 접지시스템 평가를 위한 고주파 접지임피던스 측정시스템의 설계 및 제작)

  • Gil, Hyoung-Jun;Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min;Kim, Young-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.47-52
    • /
    • 2016
  • This paper describes the design and fabrication of high frequency ground impedance measuring system for assessment of grounding system for Lightning protection. The ground impedance measuring system has been designed and fabricated which makes it possible to assess the ground impedance by frequency ranges from 100 Hz to 1 MHz. The effective grounding systems having a very low impedance to electromagnetic disturbance such as lightning surges and noises in microelectronics and high-technology branches are strongly required. In order to analyze the dynamic characteristic of grounding system impedances in lightning and surge protection grounding systems, it is highly desirable to assess the ground impedances as a measure of performance of grounding system in which lightning and switching surge currents with fast rise time and high frequency flow. The measuring system is based on the variable frequency power supply and consists of signal circuit part, main control part, data acquisition and processing unit, and voltage and current probe system. The ground impedance measuring system can be used to assess grounding system during occurrence of lightning.

Study on the Ground Fault Protection in 6.6KV Ungrounded Power System SGR Malfunction or Non-Tripping (선택지락보호계전기 오.부동작에 관한 연구)

  • Kim, Byung-Tae;Lee, Dal-Woo;Jeon, Myung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.296-301
    • /
    • 2008
  • This paper presents a study on the ground fault protection in 6.6KV ungrounded power system relay(SGR) malfunction or non-tripping. Ground test had made on 6.6KV HV(high voltage) system, Some of domestic and oversea's SGR products are different from their own specific characteristics. This study on the ground protection relay 6.6KV power supply system is focused to protect human.

Pulsed Power System for Leachate Treatment Application (침출수 처리 응용 펄스전원 시스템)

  • Jang, S.R.;Ahn, S.H.;Ryoo, H.J.;Rim, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.246-247
    • /
    • 2010
  • This paper deals with the water treatment of the leachate from sewage filled ground by a pulsed power technology. Leachate from sewage filled ground should be treated below regulation level of COD in order to prevent environmental pollution and usually treated by a chemical method. Among the pollutants mixed in the leachate, chemical compounds of benzene series are known to be difficult to break down, and need to use high cost treat methods. The treatment of the benzene compounds by high power pulsed power supply was studied. For the high-rate, cost-effective treatment of leachate, pulsed power supply should have high repetition rates and require switching devices of long lifetime. In order to meet the demands of the above condition, pulsed power generator based on semiconductor switches using IGBTs as primary switches were developed. The experimental results verified that benzene compounds can be treated effectively by high voltage electric pulses, and this fact indicates that the treatment method by pulsed power source is a promising substitute.

  • PDF