• Title/Summary/Keyword: ground loss

Search Result 861, Processing Time 0.034 seconds

Aging Characteristics of Composite Materials in Carbody of Tilting Train using Accelerated Aging Test (가속노화시험을 이용한 틸팅차량 차체 복합재의 노화특성)

  • Yoon Sung-Ho;Kim Yong-Goo;Nam Jung-pyo;Shin Kwang-Bok;Koo Dong-Hoe
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.333-338
    • /
    • 2003
  • Polymeric composite structures used in ground transportation applications such as the carbody of tilting train may be exposed to a ground environmental conditions during long-term missions. In this study, the degradation of mechanical and physical properties of graphite/epoxy composite and glass fabric/phenol composite under ground environmental conditions was investigated. Accelerated environmental conditions of ultraviolet radiation, temperature, and moisture were considered. Several types of specimens were used to investigate the effects of environmental conditions on mechanical properties of the composites. Also, storage shear modulus, loss shear modulus, and tan 8 were measured as a function of exposure times through a dynamic mechanical analyzer. Finally, composite surfaces exposed to environmental conditions were examined using a scanning electron microscope.

  • PDF

INVESTIGATION OF THE PILE MOVEMENT DUE TO TUNNELLING BY MODEL TEST AND NUMERICAL ANALYSIS

  • Lee, Yong-Joo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09c
    • /
    • pp.104-110
    • /
    • 2010
  • In this study, a series of two-dimensional model test and numerical analysis was carried out to investigate the pile movement due to tunnelling in soft ground. The model test consists of 21 cases according to locations of the pile tip over the centre position of model tunnel. To identify both the pile and ground movements a close-range photogrammetric technique was adopted in the model test. The results from the model test were compared to the two-dimensional finite element analysis using the CRISP program. It was found that the rotation point on the pile was significantly affected by factors such as the offset distance from the model tunnel and the volume loss that occurred during the tunnelling operation.

  • PDF

Effect of Etch Hole Position and Sacrificial Layer Residue on a Novel Half-Coaxial Transmission Line Filter (에치홀의 위치와 희생층의 잔류물이 전송선 필터 응답에 미치는 영향)

  • Kim, Yong-Sung;Baek, Chang-Wook;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.284-285
    • /
    • 2007
  • In this paper, we present the effect on a novel transmission line filter response by the etch hole position on the suspended ground and the residue on the resonator under ground plane. We defined the etch hole offset as the distance from the sidewall of the suspended ground to the nearest side of the etch holes. We simulated new filter responses to reflect the real value of the changed etch hole offset caused by characteristics of negative photoresist. Return loss is distorted by the residue on the center conductor remained after sacrificial layer removing. By comparison of simulation and measurements, we concluded the residue on the resonator distorted the RF response worse than etch hole offset variation did.

  • PDF

Evaluation criteria for freezing and thawing of tunnel concrete lining according to theoretical and experimental analysis

  • Moon, Joon-Shik;An, Jai-Wook;Kim, Hong-Kyoon;Lee, Jong-Gun;Lattner, Tim
    • Geomechanics and Engineering
    • /
    • v.29 no.3
    • /
    • pp.349-357
    • /
    • 2022
  • Abnormal climate events are occurring frequently around the world. In particular, cold waves and heavy snow lead to damage and deterioration of facilities, which can cause loss of life or property damage, such as shortening the lifespan of facilities. Therefore, it is very important to prepare an appropriate maintenance system and to establish a strategy to cope with abnormal weather conditions. In this study, laboratory freezing experiments were performed to analyze the freeze-thaw characteristics affecting the tunnel concrete lining, and heat flow analysis was carried out based on the test results. Based on these experimental and theoretical analysis results, quantitative freeze-thaw evaluation criteria for tunnel concrete linings were proposed.

New Single-Phase AC-AC Converters With High-Reliability and Common-Ground Structure (새로운 공통접지 고신뢰성 AC-AC 전력변환기)

  • Kim, Jeonghun;Cha, Honnyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.6
    • /
    • pp.446-453
    • /
    • 2021
  • This paper proposes enhanced single-phase pulse width modulation buck, boost, and buck-boost type ac-ac converters. The proposed converters, where input and output voltages share a common ground, require no isolated voltage sensor and have no leakage current problem. The commutation problem is solved with series-connected switching cell structures without using an additional RC snubber. In addition, with the use of the polarity of input voltage, switching patterns are determined so that the inductor currents can flow through switching devices during all operational modes. Two switches are always turned on during a half-period of the input voltage; thus, the switching loss is significantly reduced. Detailed analysis and experimental results are provided to verify the performance of the proposed converter.

Ultra Wideband Bandpsss Filter Design using the CRLH Transmission Line (CRLH 전송선로를 이용한 초광대역 대역통과 필터의 설계 및 구현)

  • Kim, Gi-Rae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.10
    • /
    • pp.2233-2238
    • /
    • 2013
  • A novel design method of ultra wideband based on the composite right-/left handed (CRLH) transmission line is presented in this paper. Defected ground structure and microstrip interdigital coupler are used to implement the CRLH transmission line. The proposed CRLH transmission line in this paper have composite characteristics of low pass filter and high pass filter, also it has good advantages of low insertion loss and ultra wide passband characteristics. The structure with different cell number are studied, and the UWB filter using 3-cell CRLH transmission line is fabricated and measured, which shows a good agreement between simulated and measured results. It has center frequency of 5 GHz, fractional bandwidth of 105 %, and insertion loss of 0.7 dB at center frequency.

Compact Printed Monopole Antenna With Inverted L-shaped Slot for Dual-band Operations

  • Kwak, Chang-Sub;Lee, Yeong-Min;Lee, Young-Soon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.1
    • /
    • pp.37-44
    • /
    • 2020
  • In this paper, we proposed a compact printed monopole antenna with an inverted L-shaped slot for dual-band operations. Two operating frequency bands are achieved with the use of an inverted L-shaped slot etched on the radiating strip for bandwidth enhancement and a defected ground structure for return loss improvement in the higher frequency band. The measured results showthat the proposed antenna has impedance bandwidths (S11< -10 dB) of 270 MHz (1.81-2.08 GHz) and 340 MHz (2.36-2.70 GHz), covering the required bandwidths for PCS (1850.5-1989.5 MHz), CDMA 2000 (1850-1990 MHz), TD-SCDMA (1880-2025 MHz) and 2.4 GHz WLAN (2400-2484 MHz). The measured return loss of the proposed antenna has a good value of approximately 27.2 dB at 2.4 GHz WLAN. The antenna's peak gains also have a high value of 1.92 dBi at 2 GHz and 2.12 dBi at 2.45 GHz. The proposed antenna shows omnidirectional radiation patterns over the entire frequency range of interest.

Changes in Balance Characteristics Affected by the Visual Information during Single Leg Stance (외발서기 시 시각정보 차단에 따른 인체 균형 특성 변화 분석)

  • Park, Jung-Hong;Kim, Gwang-Hoon;Youm, Chang-Hong;Son, Kwon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.11
    • /
    • pp.1323-1329
    • /
    • 2011
  • The purpose of study was to analyze how the visual information affects balance control of individuals during single leg stance. A total of 27 young normal people (20 males and 7 females, age: $13.7{\pm}2.6$, height: $162.3{\pm}13.2$ cm, weight: $53.9{\pm}13.9$ kg) was voluntarily involved in the experiment. The subjects were requested to maintain balance for 20 seconds with eyes both open and closed on a force plate and then foot ground reaction data were collected for that duration. Results showed that mean velocity of COP in closed eyes condition was larger 1.84 times than that of the open-eyes condition and range of vertical angle was increased approximately one degree in the closed eyes condition. To accomplish a balance, the frequency power in mediolateral and anteroposterior components of the foot-ground reaction force was increased by 1.3~1.4 times. Consequently, visual absence during single leg stance can result in critical loss of balance and lead to instability of body control.

롯드 체결에 따른 에너지 전달 평가

  • Bae, Myeong-Ho;Yoon, Hyung-Koo;Kim, Ju-Han;Lee, Jong-Sub
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.171-175
    • /
    • 2010
  • Various soil characteristics for safe construction is necessary to understand the tests using the samples collected, and head in place an energy evaluation is conducted to evaluate the ground. In-Situ testing ground, Rod length and around the intrusive when the energy loss due to friction has been measured only in the head. Abstract The purpose of this agreement when increasing contract area of Rod agreement to transform the energy attenuation and the attenuation at the energy being delivered to evaluate. To this end, the same material used in the field test, laboratory test to apply Rod diameter and length have been considered, designed to perform the experiment was to use the Rod. Energy that raised at head of Rod, was increased and decreased by contracting type. The energy difference occurs in the head with the tip that shows the energy rating may be required at the tip is showing. Abstract The energy evaluation for the Rod field test to be at the basic sources and will be able to calculate the trusted information are measured from the tip.

  • PDF