• 제목/요약/키워드: ground fault

검색결과 739건 처리시간 0.022초

군집화 기법을 이용한 GIS 열화 패턴 연구 (A Study on Degradation Pattern of GIS Using Clustering Methode)

  • 이덕진
    • 한국전기전자재료학회논문지
    • /
    • 제31권4호
    • /
    • pp.255-260
    • /
    • 2018
  • In recent years, increasing electricity use has led to considerable interest in green energy. In order to effectively supply, cut off, and operate an electric power system, many electric power facilities such as gas insulation switch (GIS), cable, and large substation facilities with higher densities are being developed to meet demand. However, because of the increased use of aging electric power facilities, safety problems are emerging. Electromagnetic wave and leakage current detection are mainly used as sensing methods to detect live-line partial discharges. Although electromagnetic sensors are excellent at providing an initial diagnosis and very reliable, it is difficult to precisely determine the fault point, while leakage current sensors require a connection to the ground line and are very vulnerable to line noise. The partial discharge characteristic in particular is accompanied by statistical irregularity, and it has been reported that proper statistical processing of data is very important. Therefore, in this paper, we present the results of analyzing ${\Phi}-q-n$ cluster distributions of partial discharge characteristics by using K-means clustering to develop an expert partial discharge diagnosis system generated in a GIS facility.

모래의 수분함유량에 따른 비저항 및 비유전율의 주파수 의존성 (Frequency Dependent Resistivity and Relative Dielectric Constant with the Water Contents in Sand)

  • 이복희;차응석;최종혁;최영철;유양우;안창환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.348-351
    • /
    • 2009
  • In order to evaluate the performance of a grounding system against lightning or fault currents including high frequency components, the grounding impedance should be considered rather than its ground resistance. Recently, some researches on the evaluation and modeling of the grounding impedances have been carried out but the results have not been yet sufficient. This paper deals with the frequency dependence of the resistivity and relative dielectric constant of sand associated with water contents. As a result, the resistivity of sand is getting lower with increasing water content and it is nearly independent on the frequency in the range of less than 1MHz, and is decreased over the frequency range of above 1MHz. Also, the relative dielectric constant is rapidly decreased with the frequency in the range of less than 10kHz, but it is nearly not dependent on the frequency over the frequency range of 10kHz. It was found from this work that the frequency dependance of resistivity and relative dielectric constant of soil should be considered in designing the grounding systems for protection against lightning or surges.

  • PDF

부재수용가의 전기설비에 대한 안전확보 방안 (A Plan to Ensure Safety of Electric Installation in Empty houses During Normal Working Hours)

  • 임용배;정종욱;정진수;배석명;조성원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.25-26
    • /
    • 2006
  • An electrical fault is defined as any abnormal condition caused by reduction in the insulation strength between energized conduction parts and ground or any grounded part of an electrical system. Failure of solid insulation can be caused by excessive mechanical tension being applied on the insulation, harsh service environment, aging, and also by corona phenomena. The number of empty houses during normal working hours is rising. As a result, the number of uninspected electric installation for general use is increasing. To define the potential risk of the electric installation, measurement of leakage current has been getting considered, but because the measured leakage current value also contained leakage current by capacitance, the measured value can not be adapted to absolute reference to the installation. Therefore, in this paper, the correlation between the condition of electric installation and leakage current were analyzed.

  • PDF

한반도 인근 지진의 Brune 응력강하량(파라미터)추정에 대한 고찰 (Estimation of Brune's Stress Drops around the Korean Peninsula)

  • 연관희;박동희;장천중
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.70-77
    • /
    • 2006
  • Stress drops of Brune's single-corner ${\omega}^2$ source model were estimated for the earthquakes (2.0$M3.5{\sim}4.0$ and increase up to $M4.5{\sim}5.0$ above which the level of the stress drop could be assumed to be flat or decrease according to whether the rupture process accompanies buried fault or surface rupturing. The converted data of corner frequency and seismic moment were nicely fitted to the relation of $M_0{\propto}f^3$ but show systematically higher corner frequencies for $M_0>10^15$ Nm. This relationship enables systematic evaluation of a scaling relation between magnitude and stress drop. The inverted level of the stress drop is comparable to the recent studies conducted domestic and abroad. A result of lower stress drop estimated by Jun(1991) is supposed to be due to the use of low frequency spectra and existence of two-comer source model around the Korean Peninsula.

  • PDF

Behaviour of asymmetric building with double variable frequency pendulum isolator

  • Soni, D.P.;Mistry, B.B.;Panchal, V.R.
    • Structural Engineering and Mechanics
    • /
    • 제34권1호
    • /
    • pp.61-84
    • /
    • 2010
  • Presented in this paper is the behaviour of asymmetric building isolated by the double variable frequency pendulum isolator (DVFPI). The DVFPI is an adoption of single variable frequency pendulum isolator (VFPI). The geometry and coefficient of friction of top and bottom sliding surfaces can be unequal. The governing equations of motion of the building-isolation system are derived and solved in incremental form. The analysis duly considers the interaction of frictional forces in the two principal directions developed at each sliding surface of the DVFPI. In order to investigate the behaviour of the base isolation using the DVFPI, the coupled lateral-torsional response is obtained under different parametric variations for a set of six far-fault earthquake ground motions and criterion to optimize its performance is proposed. Further, influences of the initial time period, coefficient of friction and frequency variation factors at the two sliding surfaces are investigated. The numerical results of the extensive parametric study help in understanding the torsional behaviour of the structure isolated with the double sliding surfaces as in the DVFPI. It is found that the performance of the DVFPI can be optimized by designing the top sliding surface initially softer and smoother relative to the bottom one.

Fiber element-based nonlinear analysis of concrete bridge piers with consideration of permanent displacement

  • Ansari, Mokhtar;Daneshjoo, Farhad;Safiey, Amir;Hamzehkolaei, Naser Safaeian;Sorkhou, Maryam
    • Structural Engineering and Mechanics
    • /
    • 제69권3호
    • /
    • pp.243-255
    • /
    • 2019
  • Utilization of fiber beam-column element has gained considerable attention in recent years due mainly to its ability to model distributed plasticity over the length of the element through a number of integration points. However, the relatively high sensitivity of the method to modeling parameters as well as material behavior models can pose a significant challenge. Residual drift is one of the seismic demands which is highly sensitive to modeling parameters and material behavior models. Permanent deformations play a prominent role in the post-earthquake evaluation of serviceability of bridges affected by a near-fault ground shaking. In this research, the influence of distributed plasticity modeling parameters using both force-based and displacement-based fiber elements in the prediction of internal forces obtained from the nonlinear static analysis is studied. Having chosen suitable type and size of elements and number of integration points, the authors take the next step by investigating the influence of material behavioral model employed for the prediction of permanent deformations in the nonlinear dynamic analysis. The result shows that the choice of element type and size, number of integration points, modification of cyclic concrete behavior model and reloading strain of concrete significantly influence the fidelity of fiber element method for the prediction of permanent deformations.

Current Limiting and Interrupting Operation of Hybrid Self-Excited Type Superconducting DCCB

  • Choi, S.J.;Lim, S.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권4호
    • /
    • pp.55-59
    • /
    • 2018
  • Currently, the development of industry makes needs larger electric supply. Providers must consider the efficiency about losses and reliability of the system. In this case, DC power system can save electrical energy; long-distance transmission line losses. Relevance to switch technology with a voltage-source converter (VSC) in AC-DC conversion system have been researched. But, protection device of DC-link against fault current is still needed to study much. VSC DC power system is vulnerable to DC-cable short-circuit and ground faults, because DC-link has a huge size of capacitor filter which releases extremely large current during DC faults. Furthermore, DC has a fatal flaw that current zero crossing is nonexistence. To interrupt the DC, several methods which make a zero crossing is used; parallel connecting self-excited series LC circuit with main switch, LC circuit with power electronic device called hybrid DC circuit breaker. Meanwhile, self-excited oscillator needs a huge size capacitor that produces big oscillation current which makes zero crossing. This capacitor has a quite effective on the price of DCCB. In this paper, hybrid self-excited type superconducting DCCB which are using AC circuit breaker system is studied by simulation tool PSCAD/EMTDC.

Distributed plasticity approach for the nonlinear structural assessment of offshore wind turbine

  • Tran, Thanh-Tuan;Hussan, Mosaruf;Kim, Dookie;Nguyen, Phu-Cuong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제12권1호
    • /
    • pp.743-754
    • /
    • 2020
  • This study provides an insight of the nonlinear behavior of the Offshore Wind Turbine (OWT) structure using the distributed plasticity approach. The fiber section beam-column element is applied to construct the finite element model. The accuracy of the proposed model is verified using linear analysis via the comparison of the dynamic characteristics. For collapse risk assessment of OWT, the nonlinear effects considering the earthquake Incident Angle (IA) have been evaluated first. Then, the Incremental Dynamic Analysis (IDA) has been executed using a set of 20 near-fault records. Lastly, fragility curves are developed to evaluate the vulnerability of structures for different limit states. Attained results justify the accuracy of the proposed approach for the structural response against the ground motions and other environmental loads. It indicates that effects of static wind and wave loads along with the earthquake loads should be considered during the risk assessment of the OWT structure.

Damages to Rubble Stone Masonry Structures during the January 24, 2020, Sivrice (Elazığ) Earthquake in Turkey

  • Ural, Ali;Firat, Fatih K.;Kara, Mehmet E.;Celik, Tulin;Tanriverdi, Sukran
    • Earthquakes and Structures
    • /
    • 제23권3호
    • /
    • pp.231-243
    • /
    • 2022
  • The earthquake with a magnitude of Mw 6.8, which occurred on January 24, 2020, hit Sivrice (Elazığ) province of Turkey. The earthquake area takes place on the East Anatolian Fault Zone (EAFZ) located between the Arabian and Turkish plates, one of the most active seismic regions in Turkey. According to the Disaster and Emergency Management Presidency of Turkey (AFAD), 584 buildings collapsed, 6845 were heavily damaged, 1207 were moderately damaged, and 14389 were slightly damaged. The authors went to the region of earthquake after the mainshock to investigate the earthquake performances of masonry buildings. This paper presents the seismological aspects of the earthquake, acceleration records, and response spectra with different damping ratios. Furthermore, some typical damages and failure mechanisms on masonry buildings like rubble stone dwellings and minarets are discussed with illustrative photos. Although many major earthquakes have occurred in the region, similar mistakes are still being made in masonry building construction. In consequence, some suggestions viewpoint of the wooden tie beams, the corner details of masonry walls, the door and window openings, the metal fasteners and the earthquake codes are made to be more careful in masonry constructions at the end of the article.

전자기파를 이용한 터널전방 예측 -해석기법 중심으로 (Prediction of ground-condition ahead of tunnel face using electromagnetic wave - analytical study)

  • 최준수;조계춘;이근하;윤지남
    • 한국터널지하공간학회 논문집
    • /
    • 제6권4호
    • /
    • pp.327-343
    • /
    • 2004
  • 터널 시공 도중이나 터널 굴착 직후 주지보재에 의한 보강 전에 터널막장 전방에 존재하는 연약암반 혹은 단층파쇄대로 인해 유발되는 터널막장의 붕괴사고가 빈번이 일어나고 있다. 기존의 지반탐사방법으로는 터널막장부근에 있는 연약암반이나 단층파쇄대를 찾기 어렵다. 본 연구에서는 이러한 문제점들을 극복하고 기존의 탐사방법들을 보완하기 위해 전자기파를 이용한 터널전방 예측방법을 제안하였다. 전기장의 특성을 고려한 Coulomb 및 Gauss 법칙을 이용하여 절리를 가지는 암반에서의 전기장을 해석하였다. 이를 바탕으로 터널막장 전방에 구형연약암반과 단층파쇄대가 존재하는 경우에 대하여 각각 전기장해석을 수행하여 이론식을 도출하였다. 또한 개발된 해석기법을 작용하여 터널 전방에 구형연약이역과 단층파쇄대가 존재하는 경우에 대하여 예제해석을 수행하였다. 해석결과는 터널 전방에 부착된 몇 개의 전극에서 측정된 암반의 저항으로부터 역함수기법을 이용하여 터널 전방에 존재하는 연약지역의 등가 크기, 위치 및 성질을 정확하게 예측할 수 있음을 보여주었다. 암반에서의 전기저항 가탐심도는 터널막장의 크기, 자연전위 및 기타 전기적 신호에 의해 영향을 받음을 알 수 있었다. 제시된 해석기법은 실내시험을 통하여 검증하였다. 가로, 세로, 높이가 각각 5cm인 콘크리트 블록 1800여 개를 가지고서 3방향 절리를 가진 암반상태를 구현하였고 터널 전방에 전기전도도가 콘크리트 블록보다 상대적으로 높은 물질을 이용하여 연약지반을 구현하였다. 모델링을 통한 실험결과는 해석결과와 거의 일치함을 보여주었다.

  • PDF