Abstract
Presented in this paper is the behaviour of asymmetric building isolated by the double variable frequency pendulum isolator (DVFPI). The DVFPI is an adoption of single variable frequency pendulum isolator (VFPI). The geometry and coefficient of friction of top and bottom sliding surfaces can be unequal. The governing equations of motion of the building-isolation system are derived and solved in incremental form. The analysis duly considers the interaction of frictional forces in the two principal directions developed at each sliding surface of the DVFPI. In order to investigate the behaviour of the base isolation using the DVFPI, the coupled lateral-torsional response is obtained under different parametric variations for a set of six far-fault earthquake ground motions and criterion to optimize its performance is proposed. Further, influences of the initial time period, coefficient of friction and frequency variation factors at the two sliding surfaces are investigated. The numerical results of the extensive parametric study help in understanding the torsional behaviour of the structure isolated with the double sliding surfaces as in the DVFPI. It is found that the performance of the DVFPI can be optimized by designing the top sliding surface initially softer and smoother relative to the bottom one.
Keywords
double variable frequency pendulum isolator; seismic isolation; asymmetric building; eccentricity; torsional coupling;
Citations & Related Records

Times Cited By Web Of Science : 2  (Related Records In Web of Science)
Times Cited By SCOPUS : 2
연도 인용수 순위
1 Fenz, D.M. and Constantinou, M.C. (2008a), "Spherical sliding isolation bearings with adaptive behavior: Theory", Earthq. Eng. Struct. Dyn., 37(2), 163-183.   DOI   ScienceOn
2 Soni, D.P., Mistry, B.B., Jangid, R.S. and Panchal, V.R. (2009), "Seismic response of the double variable frequency pendulum isolator", Struct. Control Health Monit. (in press).
3 Tena-Colunga, A. and Escamilla-Cruz, J.L. (2007), "Torsional amplifications in asymmetric base- isolated structures", Eng. Struct., 29(2), 237-247.   DOI   ScienceOn
4 Pranesh, M. and Sinha, R. (2000), "VFPI: An isolation device for aseismic design", Earthq. Eng. Struct. Dyn., 29(5), 603-627.   DOI   ScienceOn
5 Pranesh, M. and Sinha, R. (2004), "Behavior of torsionally coupled structures with variable frequency pendulum isolator", J. Struct. Eng., ASCE, 130(7), 1041-54.   DOI   ScienceOn
6 Panchal, V.R., Jangid, R.S., Soni, D.P. and Mistry, B.B. (2009), "Response of double variable frequency pendulum isolator under triaxial ground excitations", J. Earthq. Eng. (in press).
7 Nagarajalah, S., Reinhorn, A.M. and Constantinou, M.C. (1993a), "Torsional coupling in sliding base isolated structures", J. Struct. Eng., ASCE, 119(1), 130-149.   DOI
8 Nagarajalah, S., Reinhorn, A.M. and Constantinou, M.C. (1993b), "Torsion in base isolated structures with elastomeric isolation systems", J. Struct. Eng., ASCE, 119(10), 2932-2951.   DOI
9 Pan, T.C. and Kelly, J.M. (1983), "Seismic response of torsionally coupled base isolated structures", Earthq. Eng. Struct. Dyn., 11(6), 749-770.   DOI
10 Park, Y.J., Wen, Y.K. and Ang, A.H.S. (1986), "Random vibration of hysteretic systems under bidirectional motions", Earthq. Eng. Struct. Dyn., 14(4), 543-557.   DOI
11 Kasalanati, A., Reinhorn, A.M., Constantinou, M.C. and Sanders, D. (1997), "Experimental study of ball-in-cone isolation system", Proc. Structures Congress XV, ASCE, Portland, Oregon.
12 Kelly, J.M. (1986), "Aseismic base isolation: Review and bibliography", Soil Dyn. Earthq. Eng., 5(4), 202-216.   DOI   ScienceOn
13 Buckle, I.G. (1986), "Development and application of base isolation and passive energy dissipation: A world review", ATC-17, Applied Technology Council, Redwood City, California.
14 Buckle, I.G. and Mayes, R.L. (1990), "Seismic isolation: History, application and performance-a world overview", Earthq. Spectra, 6(2), 161-201.   DOI
15 Constantinou, M.C., Mokha, A.S. and Reinhorn, A.M. (1990), "Teflon bearings in base isolation II: Modelling", J. Struct. Eng., ASCE, 116(2), 455-474.   DOI
16 Eisenberger, M. and Rutenberg, A. (1986), "Seismic base isolation of asymmetric shear buildings", Eng. Struct., 8(1), 2-8.   DOI   ScienceOn
17 Fan, F.G., Ahmadi, G. and Tadjbakhsh, I.G. (1990), "Multi-story base-isolated buildings under a harmonic ground motion-Part II: Sensitivity analysis", Nucl. Eng. Des., 123(1), 17-26.   DOI   ScienceOn
18 Fenz, D.M. and Constantinou, M.C. (2006), "Behaviour of the double concave friction pendulum bearing" Earthq. Eng. Struct. Dyn., 35(11), 1403-1424.   DOI   ScienceOn
19 Tsai, C.S., Chiang, T.C. and Chen, B.J. (2005), "Experimental evaluation of piecewise exact solution for predicting seismic responses of spherical sliding type isolated structures", Earthq. Eng. Struct. Dyn., 34(9), 1027-1046.   DOI   ScienceOn
20 Tena-Colunga, A. and Gomez-Soberon, L. (2002), "Torsional response of base-isolated structures due to asymmetries in the superstructure", Eng. Struct., 24(12), 1587-1599.   DOI   ScienceOn
21 Wen, Y.K. (1976), "Method for random vibration of hysteretic systems", J. Eng. Mech. Div., ASCE, 102(2), 249- 263.
22 Zayas, V., Low, S. and Mahin, S. (1987), "The FPS system: Experimental report", Report No. UCB/EERC-87- 01, Earthquake Engineering Research Centre, Berkeley, California.
23 Fenz, D.M. and Constantinou, M.C. (2008b), "Spherical sliding isolation bearings with adaptive behavior: Experimental verification", Earthq. Eng. Struct. Dyn., 37(2), 185-205.   DOI   ScienceOn
24 Kim, Y.S. and Yun, C.B. (2005), "Analysis and design of double friction pendulum systems for seismic isolation", The Second International Conference on Structural Health Monitoring of Intelligent Infrastructure, Korea.
25 Lee, D.M. (1980), "Base isolation for torsion reduction in asymmetric structure under earthquake loading", Earthq. Eng. Struct. Dyn., 8(4), 349-359.   DOI   ScienceOn
26 Naeim, F. and Kelly, J.M. (1999), Design of Seismic Isolated Structures: From Theory to Practice, Wiley, New York.
27 Jangid, R.S. (1995), "Seismic response of an asymmetric base isolated structure", Comput. Struct., 60(2), 261- 267.
28 Jangid, R.S. and Datta, T.K. (1994) "Non-linear response of torsionally coupled base isolated structure", J. Struct. Eng., ASCE, 120(1), 1-22.   DOI   ScienceOn
29 Jangid, R.S. and Kelly, J.M. (2000), "Torsional displacement in base-isolated buildings", Earthq. Spectra, 16(2), 443-454.   DOI   ScienceOn