• Title/Summary/Keyword: ground characterization

Search Result 180, Processing Time 0.028 seconds

Separation and Characterization of Dust and Ground Water Particulates Using Gravitational SPLITT Fractionation.

  • Lee, Seung Ho;Park, Hui Yeong;Lee, Sang Geun;Yong, Seong Gwon;Eum, Cheol Hun
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.6
    • /
    • pp.616-622
    • /
    • 2001
  • Split-flow thin (SPLITT) cell Fractionation(SF) is a technique that allows separation of particulates and macromolecules into two fractions. A gravitational SF(GSF) system is constructed and tested for its applicability for separation of dust and ground water particulates. When tested with polystyrene latex particles, experimental data were in good agreements with theory. The 9.8 and 21.4㎛ polystyrene particles were successuflly separated in a continuous mode, where the mixture is continuously fed into the GSF channel allowing separation in a large sacle. The GSF system is successfully applied to continuous separation of dust and ground water particels based on the sedimentation coefficient, which is closely related to the particle size. The separations were confirmed by microscopy and energy-dispersive X-ray (EDX) analysos.

Characterization of Airborne Bioaerosol Concentration in Public Facilities (다중이용시설내 공기중 바이오에어로졸 농도분포 특성에 관한 연구)

  • Lee, Cheol Min;Kim, Yun Sin;Lee, Tae Hyeong;Park, Won Seok;Hong, Seung Cheol
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.215-222
    • /
    • 2004
  • This study was conducted to evaluate the characterization of airborne bioaerosol in public facilities in Seoul. A total of 17 public facilities were investigated from December, 2002 to February, 2003. As results of the survey, the mean concentrations of bacteria and fungi in indoor air of public facilities were $378.08\pm296.33$ CFU/㎥ by RCS and $106.38\pm171.63$ CFU/㎥ and $347.46\pm335.32$ CFU/㎥ and $95.23\pm62.61$ CFU/㎥, by Six-stage cascade air sampler respectively. The mean concentrations of bacteria in indoor air (by ventilation method) were $517.14\pm343.93$ CFU/㎥ of natural ventilation and $215,83\pm100.71$ CFU/㎥ of mechanical ventilation. The mean concentrations of fungi in indoor air (by ventilation method) were $83.14\pm79.16$ CFU/㎥ of natural ventilation and $133.50\pm248.07$ CFU/㎥ of mechanical ventilation. The mean concentrations of bacteria in indoor air were 449.44 CFU/㎥ for the ground and $217.50\pm103.68$ CFU/㎥ for the underground. The mean concentrations of fungi in indoor air were $63.89\pm77.66$ CFU/㎥ for the ground and $202.00\pm290.08$ CFU/㎥ for the underground.

Probabilistic Q-system for rock classification considering shear wave propagation in jointed rock mass

  • Kim, Ji-Won;Chong, Song-Hun;Cho, Gye-Chun
    • Geomechanics and Engineering
    • /
    • v.30 no.5
    • /
    • pp.449-460
    • /
    • 2022
  • Safe underground construction in a rock mass requires adequate ground investigation and effective determination of rock conditions. The estimation of rock mass behavior is difficult, because rock masses are innately anisotropic and heterogeneous at different scales and are affected by various environmental factors. Quantitative rock mass classification systems, such as the Q-system and rock mass rating, are widely used for characterization and engineering design. The measurement of rock classification parameters is subjective and can vary among observers, resulting in questionable accuracy. Geophysical investigation methods, such as seismic surveys, have also been used for ground characterization. Torsional shear wave propagation characteristics in cylindrical rods are equal to that in an infinite media. A probabilistic quantitative relationship between the Q-value and shear wave velocity is thus investigated considering long-wavelength wave propagation in equivalent continuum jointed rock masses. Individual Q-system parameters are correlated with stress-dependent shear wave velocities in jointed rocks using experimental and numerical methods. The relationship between the Q-value and the shear wave velocity is normalized using a defined reference condition. This relationship is further improved using probabilistic analysis to remove unrealistic data and to suggest a range of Q-values for a given wave velocity. The proposed probabilistic Q-value estimation is then compared with field measurements and cross-hole seismic test data to verify its applicability.

Near-ground wind and its characterization for engineering applications

  • Crandell, Jay H.;Farkas, William;Lyons, James M.;Freeborne, William
    • Wind and Structures
    • /
    • v.3 no.3
    • /
    • pp.143-158
    • /
    • 2000
  • This report presents the findings of a one-year monitoring effort to empirically characterize and evaluate the nature of near-ground winds for structural engineering purposes. The current wind engineering practice in the United States does not explicitly consider certain important near-ground wind characteristics in typical rough terrain conditions and the possible effect on efficient design of low-rise structures, such as homes and other light-frame buildings that comprise most of the building population. Therefore, near ground wind data was collected for the purpose of comparing actual near-ground wind characteristics to the current U.S. wind engineering practice. The study provides data depicting variability of wind speeds, wind velocity profiles for a major thunderstorm event and a northeaster, and the influence of thunderstorms on annual extreme wind speeds at various heights above ground in a typical rough environment. Data showing the decrease in the power law exponent with increasing wind speed is also presented. It is demonstrated that near-ground wind speeds (i.e., less than 10 m above ground) are likely to be over-estimated in the current design practice by as much as 20 percent which may result in wind load over-estimate of about 50% for low-rise buildings in typical rough terrain. The importance of thunderstorm wind profiles on determination of design wind speeds and building loads (particularly for buildings substantially taller than 10 m) is also discussed. Recommendations are given for possible improvements to the current design practice in the United States with respect to low-rise buildings in rough terrain and for the need to study the impact of thunderstorm gust profile shapes on extreme value wind speed estimates and building loads.

Sensory Characterization of Fish Jerky Produced from Frame Muscle of the Sea Rainbow Trout Oncorhynchus mykiss (해수산 무지개송어(Oncorhynchus mykiss) 프레임 육포의 관능 특성)

  • Kim, Yong Jung;Kim, Min Woo;Kim, Min Joo;Lee, Su Gwang;Park, Sun Young;Kim, Jin-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.49 no.3
    • /
    • pp.270-276
    • /
    • 2016
  • This study investigated the sensory characteristics (texture, odor, taste and color) of jerky produced from ground sea rainbow trout (SRT) Oncorhynchus mykiss frame muscle (FM). The hardness of the ground SRT-FM jerky was 453.9±91.0 g/cm2, which was lower than that of commercial animal jerky (893.5±404.6 g/cm2) and commercial fish jerky (1,394.4±363.5 g/cm2). The difference in the hardness values of the ground SRT-FM jerky and commercial animal jerky was not significant. The volatile basic nitrogen content of the ground SRT-FM jerky was 48.3±1.6 mg/100 g, which was higher than that of commercial fish jerky (21.6±6.2 mg/100 g) and commercial animal jerky (18.2±6.3 mg/100 g). However, the fish odor of the ground SRT-FM jerky was masked by the presence of various additives. The hydrophilic and lipophilic browning indices of the ground SRT-FM jerky were higher than those of the commercial jerky. The total taste value of the ground SRT-FM jerky was 169.0, and the major amino acids were glutamic acid and aspartic acid. These results suggest that ground SRT-FM jerky would be acceptable to consumers.

Study on the size-based separation of nano to micron particles in natural water and soil using flow and sedimentaion Field-flow fractionation (흐름 및 침강 장-흐름 분획법에 의한 자연수 및 토양 중 나노 크기로부터 마이크론 입자들의 크기별 분리에 관한 연구)

  • Eum, Chul Hun;Kang, Dong Young;Lee, Tae Woo;Lee, Seungho
    • Analytical Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.75-81
    • /
    • 2009
  • A flow and sedimentation field-flow fractionation method has been used to characterize colloidal particles in environmental samples. The opposed flow sample concentration (OFSC) method was employed. The OFSC procedure was optimized for the analysis of particles in ground water with respect to various experimental parameters including sample introduction time, flow rates, etc. The effectiveness in low concentration and characterization of the OFSC-FlFFF was demonstrated with GW-1 and GW-2 ground water samples. Ground water of upto 100 mL has been successfully loaded, concentrated, and characterized by OFSC-FlFFF. The OFSC technique allow the application of FlFFF possible for the separation and characterization of colloidal particles in very low concentrations. The results show FFF provides a simplified alternative to existing off-line concentration procedures, and shows a high potential for the applications to the analysis of dilute colloidal particles in the environmental samples.

Preparation and Characterization of Polypropylene/Waste Ground Rubber Tire Powder Microcellular Composites by Supercritical Carbon Dioxide

  • Zhang, Zhen Xiu;Lee, Sung-Hyo;Kim, Jin-Kuk;Zhang, Shu Ling;Xin, Zhen Xiang
    • Macromolecular Research
    • /
    • v.16 no.5
    • /
    • pp.404-410
    • /
    • 2008
  • In order to obtain 'value added products' from polypropylene (PP)/waste ground rubber tire powder (WGRT) composites, PP/WGRT microcellular foams were prepared via supercritical carbon dioxide. The effects of blend composition and processing condition on the cell size, cell density and relative density of PP/WGRT micro-cellular composites were studied. The results indicated that the microcellular structure was dependent on blend composition and processing condition. An increased content of waste ground rubber tire powder (WGRT) and maleic anhydride-grafted styrene-ethylene-butylene-styrene (SEBS-g-MA) reduced the cell size, and raised the cell density and relative density, whereas a higher saturation pressure increased the cell size, and reduced the cell density and relative density. With increasing saturation temperature, the cell size increased and the relative density decreased, whereas the cell density initially increased and then decreased.

Analisys about the Earth Fault Characteristics in the Wireless Power Transmission System of the Electric Vehicle (무선충전 전기자동차 전력공급장치에서의 지락사고 특성 분석)

  • Jung, Jin-Soo;Han, Woon-Ki;Park, Chan-Um;Song, Young-Sang;Lim, Hyun-Sung;Cho, Min-Ho;Lyu, Ji-Yun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.13-17
    • /
    • 2014
  • In this paper, the risk of electric shock is analyzed through analysis for characterization of potential distribution analysis and ground fault current analysis near the area where there are occurred a ground fault at electric vehicle wireless charging system using 20kHz. Studies for electric vehicle wireless charging system are in the works for development of efficiency increase, pickup shape design and communication module as a fundamental research step. But the research related to electrical safety and is still scarce state so that more studies are necessary to commercialize. As a result of analysis, it is verified that induced voltage is arisen more up to 45V near the a area of accident during ground fault and fault current has been maintained continuously without clearing fault condition by operating characteristics for circuit breaker and inverter.

환경물리탐사 기법을 이용한 유류오염 주유소 부지 특성 조사

  • Kim Chang-Ryeol;Go Gyeong-Seok;Kim Jeong-Ho;Park Sam-Gyu;Son Jeong-Sul;Jeong Ji-Min
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.429-432
    • /
    • 2005
  • Geophysical investigations, as a non-invasive method, were conducted at the former gas station site contaminated with fuel hydrocarbons. GPR (Ground Penetrating Radar) survey was performed to locate buried objects such as USTs (Underground Storage Tanks) and fuel pipes which might serve as a origin of the site contamination. Additional GPR investigation and a resistivity survey were conducted to map water table and to characterize shallow geologic structures of the site. The results of the study have shown that seven USTs including one unknown UST and buried fuel pipes are present, and that the groundwater elevation varies with topography from approximately 1.5 to 3m below the surface and the water table is located in the residual soils above the bedrock in the site. The results also show that the geophysical methods can be a very useful tool for the characterization of the contaminated site.

  • PDF

Interconnect Characterization for High Speed MCM Application (High Speed MCM 적용을 위한 Interconnect Characterization 에 대한 연구)

  • 이경환
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.4 no.2
    • /
    • pp.25-32
    • /
    • 1997
  • 대용량, 고속 정보처리가 요구되는 System의 모듈은 Data 처리의 고속성 및 회로의 고집적이 가능한 MCM의 형태로 구현되어 ATM, GPS 및 PCS 등의 분야에 광범위하게 응 용되고 있다. 위와 같은 High Speed 응용분야에서의 System 성능은 Interconnect Line의 전달지연, 임피던스 부정합에 의한 신호 반사 손실. 신호선 간의 Crosstalk, Ground Bounce 등의 현상에 대한 최적화 여부에 결정적인 영향을 받는다. 그러나 Interconnect의 특성상 정 형이 존재하지 않으므로 추상적인 Library를 구축하는 형식으로 접근할 수밖에 없으며 이를 위하여 여러기본 구조를 정의한후 각 Dimension을 변수로 두고 해석 결과를 합성하여 Database화하는 접근방식이다. 본 논문에서는 MCM-D 공정을 이용하여 Interconnect Line 특성을 분석하고 Database화 하기 위한 Test Pattern을 구현하고 Time Domain reflectometry(TDR)을 이용하여 그특성들을 측정 분석하였다. Test pattern 제작은 MCM-D 공정으로 최소선폭 27$\mu$m, Via Hole 75$\mu$m으로 형성하였고 2 Layer Signal과 GND로 총 3Layer를 구현하였다. 특성분석을 위해 TDR장비와 모데링 및 Simulation S/W인 IPA 510 을 사용하였다. 이를 통해 MCM-D를 이용한 공정에서 Interconcet Line의 고주파 특성을 측정하고 정량화하여 LIbrary를 제작할수 있었다.