• Title/Summary/Keyword: grip system

Search Result 124, Processing Time 0.027 seconds

Research of Grip Forces and Subjective Preferences for Various Individual Finger Grip Spans by using an (MFFM System을 이용한 손가락 별 파지 폭들의 변화에 따른 악력 및 개인 선호도에 대한 연구)

  • Kim, Dae-Min;Kong, Yong-Ku
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.3
    • /
    • pp.1-6
    • /
    • 2008
  • Individual finger/total grip forces, and subjective preferences for various individual finger grip spans (i.e., four fingers had identical grip spans or different grip spans) were evaluated by using an "Adjustable Multi-Finger Force Measurement (MFFM) System". In this study, three grip spans were defined as follows: a 'favorite grip span' which is the span with the highest subjective preference; a 'maximum grip span' which is the span with the highest total grip force; a 'maximum finger grip span' which is a set of four grip spans that had maximum finger grip forces associated with the index, middle, ring, and little fingers, respectively. Ten males were recruited from university population for this study. In experiment I, each participant tested the maximum grip force with five grip spans (45 to 65mm) to investigate grip forces and subjective preferences for three types of grip spans. Results showed that subjective preferences for grip spans were not coincidence with the performance of total grip forces. It was noted that the 'favorite grip span' represented the lowest total grip force, whereas the 'maximum finger grip span' showed the lowest subjective preferences. The individual finger forces and the average percentage contribution to the total finger force were also investigated in this study. The findings of this study might be valuable information for designing ergonomics hand-tools to reduce finger/hand stress as well as to improve tool users' preferences and performance.

Detecting Driver Fatigue by Steering Wheel Grip Force

  • LEE, KYEHOON;HYUN, SUNG-AE;OAH, SHEZEEN
    • International Journal of Contents
    • /
    • v.12 no.1
    • /
    • pp.44-48
    • /
    • 2016
  • Driver fatigue is a major cause of fatal road accidents and has significant implications in road safety. In recent years, researchers have investigated steering wheel grip force as an alternative method to detect driver fatigue noninvasively and in real time. In this study, a fatigue detection system was developed by monitoring the grip force and changes in the grip force were measured while participants' engaged in an interactive simulated driving task. The study also measured the participants' subjective sleepiness to ensure the validity of measuring grip force. The results indicated that while participants engaged in a driving task, steering wheel grip force decreased and subjective sleepiness increased concurrently over time. The possible applications of the driver fatigue detection system by steering wheel grip force and future guidelines are discussed.

Evauation of Hygienic Status of High School Foodservice using ATP Bioluminescence Assay & Microorganism Test Strips (ATP Bioluminescence와 간이미생물배지를 이용한 고등학교 급식시설의 위생상태 조사연구)

  • Jang, Jae-Seon;Hwang, Seong-Hee
    • The Korean Journal of Food And Nutrition
    • /
    • v.28 no.5
    • /
    • pp.918-925
    • /
    • 2015
  • An investigation was conducted to evaluate the hygienic status of 33 high school foodservice systems in Yongin city by using hygiene management guide checklist, ATP bioluminescence assay and microbe inspection petrifilm (APC, coliform group, Staphylococcus aureus) of food utensils during use. The 22 hygiene management guide checklist items about facilities, personal hygiene, food control, distribution, washing and disinfection had good grade but there were some inadequate behaviors on observation. The inspection results showed their sanitary condition met the level B of the recommendation of Korea method, it means sanitary management system get settled but more practical CCP system was needed. ATP bioluminescence assay was conducted on surface of food facilities, ATP ranged 425~2,552 RLU on gloves, 541~70,251 RLU on apron, 1,596~88,490 RLU on working desk, 1,177~263,813 RLU on sterilizer grip, 715~32,814 RLU on sterilizer shelf, 114~619,725 RLU on refrigerator grip, 677~319,007 RLU on refrigerator shelf, 71~196,725 RLU on freezer grip, 1,535~233,375 RLU on freezer shelf. APC ranged $66.7{\pm}29.0CFU$ on freezer grip, $102.1{\pm}35.9CFU$ on refrigerator grip, $45.4{\pm}28.2CFU$ on heating cabinet grip, $58.8{\pm}40.4CFU$ on sterilizer grip, the number of coliform group ranged $5.6{\pm}4.9CFU$ on freezer grip, $9.1{\pm}8.7CFU$ on refrigerator grip, $1.2{\pm}1.1CFU$ on heating cabinet grip, $4.5{\pm}4.4CFU$ on sterilizer grip. S. aureus ranged $8.0{\pm}5.6CFU$ on freezer grip, $12.2{\pm}9.6CFU$ on refrigerator grip, $2.1{\pm}1.6CFU$ on heating cabinet grip, $11.6{\pm}6.4CFU$ on sterilizer grip.

A Comparative Study on the Testing Methods for the Analysis of Tensile Strength of GERP Rebars (GFRP 보강근의 인장강도 분석을 위한 시험방법 비교 연구)

  • You, Young-Chan;Park, Ji-Sun;You, Young-Jun;Park, Young-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.303-312
    • /
    • 2006
  • The main objective of this experimental study is to examine the feasibilities of each testing method with various kinds of grip systems for the analysis of tensile strength of GFRP(glass fiber reinforced polymer) reinforcing bars. Three types of grip systems were examined such as resin-sleeved pipe-type grip proposed by CSA(Canadian Standard Association), frictional resistance type metal grip by ASTM(American Standard for Testing and Materials) and wedge-inserted cone-type grip normally used in prestressing tendons. Also, mechanical properties of GFRP rebars with different surface deformations were investigated for each different type of testing grip used in this study. All testing procedures including specimens preparation, set-up of test equipments and measuring devices were made according to the CSA S806-02 recommendations. From the test results, it was found that the highest tensile strengths of GFRP rebars were observed when tested by resin-sleeved grip system regardless of their different surface deformations. But tensile strengths of GFRP rebars by ASTM grip system are only 10% less than those by CSA grip system. On the other hand, CSA grip is not only difficult to prepare but also not disposable. Therefore, ASTM grip system is recommended as a practical alternative to estimate the tensile strength of GFRP rebars.

Development of Putting Grip Sensor System (퍼팅그립 악력 측정시스템의 개발에 관한 연구)

  • Tack, Gye-Rae;Lim, Young-Tae;Yoon, Jeong-Min;Kim, Hyung-Sik;Yi, Jeong-Han
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.2
    • /
    • pp.113-117
    • /
    • 2005
  • As a preliminary study of finding the relationship between the force at the grip and the success rate during putting stroke, the putting grip sensor system using FSR sensors was developed. The system consisted of the hardware which had the sensor part with 8 sensors per putting glove and data acquisition part as well as the software which had the real-time monitoring program and the offline post-processing program. After experiments with elite-golfer using this system, it is possible to suggest the proper force ranges at the grip during putting stroke.

Simultaneous Measurement of Vibration and Applied Forces at a Power Tool Handle for the Reduction of Random Error When valuating Hand-transmitted Vibration (수전달 진동평가량의 랜덤오차 저감을 위한 공구 핸들에서의 진동과 작용력의 동시 측정)

  • Choi, Seok-Hyun;Jang, Han-Kee;Park, Tae-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.4 s.97
    • /
    • pp.404-411
    • /
    • 2005
  • To increase accurateness and reliability of the evaluation of power tool vibration transmitted to an operator, it is necessary to measure the grip and feed forces during the measurement of hand-transmitted vibration. In the study a system was invented to measure the vibration and the grip and/or feed force, which consists of a measurement handle and a PC with a data acquisition system and the corresponding software. Strain gauges and an accelerometer were mounted on the handle surface for the simultaneous measurement of the forces and the vibration. The program in the system makes it possible to monitor the grip and feed force during the tool operation so that the operator keeps the applying forces within the pre-determined range. Investigating the vibration total values, frequency-weighted root-mean-square accelerations at the handle, obtained in repetition for each power tool with control of the grip and feed force showed more consistency than those measured without force control. By using the system the experimenter can reduce random error of the measured vibration.

The Simultaneous Measurement of Vibration and Applied forces at a Power tool handle for the Evaluation of Hand-transmitted Vibration (수전달 진동 평가를 위한 공구 핸들에서의 진동과 작용력의 동시 측정)

  • Choi, Seok-Hyun;Jang, Han-Kee;Park, Tae-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.689-694
    • /
    • 2004
  • To increase accurateness and reliability of the evaluation of power tool vibration transmitted to an operator, it is necessary to measure grip and feed forces during the measurement of hand-transmitted vibration. In the study a system was invented to measure the vibration and the grip and/or feed force, which consists of a measurement handle and a PC with data acquisition system and the software. Strain gauges and an accelerometer were mounted on the handle for the simultaneous measurement of the forces and the vibration. The program in the system makes it possible to monitor the grip and feed force during the tool operation so that the operator keeps the applying forces within the pre-determined range. Investigating the vibration total values, frequency-weighted root mean square accelerations at the handle, obtained at various conditions with control of the grip and feed force showed more consistency than those measured without force control. By using the system the experimenter can reduce uncertainty of the measured vibration.

  • PDF

Development of Grip Strength Training and Evaluation System of Hand Functions (악력 훈련 및 평가를 위한 측정 시스템 개발에 관한 연구)

  • Kang, Han-Su;Chung, Sung-Taek
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.3
    • /
    • pp.611-617
    • /
    • 2009
  • The primary purpose of this study was to analysis quantitatively the degree of injury and/or the progress of treatment for physical impairment. This study provided a more detailed study that evaluates all test parameters including maximum grip strength, duration of operation, average grip strength, acceleration work, dynamic endurance time and percent change in static endurance. Also, a complete database management system is developed and used to store related training, evaluation, and personal information. In addition, the system is developed a grip sensor using load.cell transducer (${\leq}60kg$). The system will be efficient to operate and convenient to use, furthermore, it can be helped for understanding and analysis the progress of a patient during a doctor's rehabilitation program.

The Effect of Various Wheelchair Handle Directions on Muscle Activity of Adult Male Trunks When Climbing Ramps

  • Ahn, Su-Hong;Lee, Su-Kyong
    • PNF and Movement
    • /
    • v.17 no.3
    • /
    • pp.379-389
    • /
    • 2019
  • Purpose: This study examined the effects of wheelchair handle directions on the trunk muscle activity of adult males when climbing ramps. It also evaluated the wheelchair attendant's physical discomfort during tasks. Methods: Healthy males aged over 20 years were chosen and the direction of wheelchair handle grip was randomly selected. The grips included a general grip with ulnar deviation, a medial grip with wrist pronation, and a neutral grip with a neutral wrist. The trunk muscle activity was measured using surface electromyography. Furthermore, the physical discomfort of wheelchair attendants was subjectively evaluated using the Borg CR-10 Scale, which rates the perceived exertion. In addition, the SPSS 18.0 program was used perform repeated measure ANOVA to compare muscle activity and subjective discomfort during the interventions. The contrast test was also conducted with a significance level (α) of 0.05. Results: There was significant difference between the general grip and the medial grip in the rhomboid major muscle and the lumbar erector spinae muscle (p<0.05). In addition, there was significant difference between the general grip and the neutral grip in the rhomboid major muscle and the lumbar erector spinae muscle (p<0.05). Further, there was significant difference between the general grip and the neutral grip in subjective discomfort (p<0.05). Conclusion: In this study, adult male trunk muscle activity and subjective discomfort were lowest when using the neutral grip while climbing ramps. Accordingly, we suggest that neutral grips will help improve the function of the musculoskeletal system and reduce the subjective discomfort by putting less strain on the trunk muscles and maximizing efficiency with less force.

A Study on Grip Force and Angular Kinematics during Golf Putting Stroke (그립악력과 각운동학을 이용한 골프 퍼팅 분석)

  • Choi, Jin-Seung;Kim, Hyung-Sik;Lim, Young-Tae;Yi, Jeong-Han;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.125-131
    • /
    • 2007
  • The purpose of this study was to evaluate the difference in grip force and angular kinematic variables between elite (handicap${\leq}2$) and novice golfers. Three-dimensional motion analysis system with synchronized grip force measurement system was used. The participants consisted of two groups based on their playing ability: 10 elite golfers and 10 novice golfers. Each subject performed 5 putting strokes at the distance of 1, 3, and 5m with randomly selected order. During entire putting phase, elite group showed relatively constant grip force but novice group showed continuously increasing grip force pattern. There existed a clear difference in the trajectory of shoulder line between two groups. As for novice group the rotational center did not converge into one point, for elite group the rotational center converged into precise single point. And there was a clear difference pattern in anterior-posterior directional movement at shoulder between two groups. These difference might be helpful for improving consistent putting skills.