• Title/Summary/Keyword: grid-based

Search Result 3,563, Processing Time 0.032 seconds

Ontology-based Grid Resource Selection System (온톨로지 기반의 그리드 자원선택 시스템)

  • Noh, Chang-Hyeon;Jang, Sung-Ho;Kim, Tae-Young;Lee, Jong-Sik
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.3
    • /
    • pp.169-177
    • /
    • 2008
  • Grid resources are composed of various communication networks and operation systems. When a grid system searches and selects grid resources, which meet requirements of a grid user, existing grid resource selection systems are limited due to their storage methods for resource information. In order to select grid resources suitable for requirements of a grid user and characteristics of data, this paper constructs an ontology for grid resources and proposes an ontology-based grid resource selection system. This system provides an inference engine based on rules defined by SWRL to create a resource list. Experimental results comparing the proposed system with existing grid resource selection systems, such as the Condor-G and the Nimrod-G, verify the effectiveness of the ontology-based grid resource selection system with improved job throughput and resource utilization and reduced job loss and job processing time.

  • PDF

Grid Coverage Component Development Reusing Existing Grid Coverage Components

  • Kim, Hong-Gab;Lim, Young-Jae;Kim, Kyung-Ok
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1105-1107
    • /
    • 2003
  • Remote sensing data processing and analysis system can be developed based on the Grid Coverage Specification and this kind of system is also can be easily interoperate with GIS systems conforming OpenGIS specification. This paper proposes a method to implement easily and quickly the new grid coverages that provide new operations, or services, by reusing the existing grid coverage components, which is based on the fact that the pipeline constructed by grid coverages can be represented in one grid coverage. This method complements easily the deficiency of the existing grid coverage components and enables quick implementation of the new grid coverage that provides complex processing operations.

  • PDF

FREE SURFACE FLOW ANALYSIS BY SOROBAN GRID BASED CIP MEHTOD (Soroban grid 기반 CIP법을 이용한 자유표면 유동해석)

  • Im, H.N.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.326-334
    • /
    • 2010
  • In this study, we provide a comprehensive review of the CIP(Constrained Interpolation Pro file/Cubic Interpolated Propagation) method with a pressure-based algorithm that is known as a general numerical solver for soled liquid, gas and plasmas. And also we introduce a body-fitted grid system(Soroban grid) for computation of strongly nonlinear marine hydrodynamic problems such as slamming water on deck, wave impact by green water. This grid system can keep the third-order accuracy in time and space with the help of the CIP method. The grid system consists of the straight lines and grid points. In the 2-dimensional grid case, each grid points moving in these lines like abacus - Soroban in Japanese. The length of each line can be different and the number of grid points in each line can be different. Mesh generation and searching of upstream departure point are very simple and possible to mesh-free treatment. To optimize computation of free-surface and multi-fluid flows, We adopt the C-CUP method. In most of the earlier computations, the C-CUP method was used with a staggered-grid approach. Here, because of the mesh free nature of the Soroban grid, we use the C-CUP method with a collocated-grid approach.

  • PDF

Exploring Low-Cost Grid-based Tactile Instruments for Understanding and Reproducing Shapes for People with Visual Impairments

  • Yeojin Kim;Jiyeon Han;Uran Oh
    • International journal of advanced smart convergence
    • /
    • v.12 no.3
    • /
    • pp.127-140
    • /
    • 2023
  • While tools exist for blind people to understand shapes, these are not commercially available nor affordable and often require the assistance of sighted people. Thus, we designed two low-cost grid-based tactile tools using toggle buttons (TogGrid) and cotton balls (CottonGrid). To assess the potential of these as an educational tool, we conducted a user study with 12 people with visual impairments where they were asked to understand and reproduce shapes under different conditions. Although CottonGrid is relatively cheap and easy to make, findings show that TogGrid was perceived to be better in terms of perceived easiness, task completion time, accuracy, and preference in general. Particularly, participants valued TogGrid for enabling them to identify and correct errors. Based on the findings, we provide implications for utilizing toggle buttons for designing educational instruments for learning and expressing shapes for blind people.

Characteristic of Data Distribution and Data Replication based Model of LDAP System in High Performance Grid Environments (고성능 Grid 환경에서의 LDAP 시스템의 분산모델과 복제모델의 특성)

  • 권성호;김희철
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.9 no.1
    • /
    • pp.77-84
    • /
    • 2004
  • Recently, as the number of entities participating in the Grid system increased, the response time of LDAP system became inadequate. Consequently, we have to design new LDAP that suitable for high performance Grid environments. For this, researches about analysis of performance LDAP system are needed firstly. However, because researches are focused mostly on read operation optimized environments, so these result of researches are not directly applied to high performance Grid environments that write operation occupies most. In this paper, we provide overall results of analysis of performance of LDAP system with respect to number of node, query arrival rate, probability of read and so on. The analysis is based on in analytic performance model by applying the M/M/1 queuing model. Finally, based on the results, we suggest the direction for the design of high performance LDAP system and this research results can be applied as basic materials to design of GIS in high performance Grid environments as well as.

  • PDF

Decentralized Vehicle-to-Grid Design for Frequency Regulation within Price-based Operation

  • Kim, Seung Wan;Jin, Young Gyu;Song, Yong Hyun;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1335-1341
    • /
    • 2015
  • The utilization of electric vehicles has been suggested to support the frequency regulation of power system. Assuming that an intermediate aggregator exists, this study suggests a decentralized vehicle-to-grid operation scheme in which each vehicle-to-grid aggregator can behave independently of the power system operator. To implement this type of decentralized operation, this study adopts a price-based operation that has been proposed by many researches as an alternative operation scheme for the power system. In this environment, each vehicle-to-grid aggregator can determine its participation in vehicle-to-grid service in consideration of its residual energy of aggregated system and real-time market price. Consequently, the main purpose of this study is to verify whether or not the vehicle-to-grid power can effectively support the current frequency regulation function within the price-based operation scheme. Specifically, a frequency regulation method is proposed based on the real-time price signal, and a feedback controller for battery management is designed for decentralized vehicle-to-grid operation.

Communication Architecture of the IEC 61850-based Micro Grid System

  • Yoo, Byong-Kwan;Yang, Seung-Ho;Yang, Hyo-Sik;Kim, Won-Yong;Jeong, Yu-Seok;Han, Byung-Moon;Jang, Kwang-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.605-612
    • /
    • 2011
  • As the power grids are integrated into one big umbrella called a "smart grid," communication protocol plays a key role in successful operations. The successful deployment of smart grid interoperability is a major hurdle that must be overcome. The micro grid, a small power system that distributes energy resource, is operated in diverse regions. Different vendors use different communication protocols in the operation of the micro grid. Recently, the IEC 61850 has been legislated to solve the interoperability problems in power utility automation. The present paper presents a micro grid system based on the IEC 61850 protocol. It consists of a micro grid monitoring system, a protocol converter that transforms serial data to IEC 61850 data, and distributed energy resource controllers for diverse DER nodes. A developed communication gateway can be deployed for DER controllers with serial links to exchange data with IEC 61850-based devices. The gateway can be extended to IEC 61850-based distribution automation systems, substation automation systems, or SCADA.

Virtual Flux and Positive-Sequence Power Based Control of Grid-Interfaced Converters Against Unbalanced and Distorted Grid Conditions

  • Tao, Yukun;Tang, Wenhu
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1265-1274
    • /
    • 2018
  • This paper proposes a virtual flux (VF) and positive-sequence power based control strategy to improve the performance of grid-interfaced three-phase voltage source converters against unbalanced and distorted grid conditions. By using a second-order generalized integrator (SOGI) based VF observer, the proposed strategy achieves an AC voltage sensorless and grid frequency adaptive control. Aiming to realize a balanced sinusoidal line current operation, the fundamental positive-sequence component based instantaneous power is utilized as the control variable. Moreover, the fundamental negative-sequence VF feedforward and the harmonic attenuation ability of a sequence component generator are employed to further enhance the unbalance regulation ability and the harmonic tolerance of line currents, respectively. Finally, the proposed scheme is completed by combining the foregoing two elements with a predictive direct power control (PDPC). In order to verify the feasibility and validity of the proposed SOGI-VFPDPC, the scenarios of unbalanced voltage dip, higher harmonic distortion and grid frequency deviation are investigated in simulation and experimental studies. The corresponding results demonstrate that the proposed strategy ensures a balanced sinusoidal line current operation with excellent steady-state and transient behaviors under general grid conditions.

PARALLEL IMPROVEMENT IN STRUCTURED CHIMERA GRID ASSEMBLY FOR PC CLUSTER (PC 클러스터를 위한 정렬 중첩 격자의 병렬처리)

  • Kim, Eu-Gene;Kwon, Jang-Hyuk
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.157-162
    • /
    • 2005
  • Parallel implementation and performance assessment of the grid assembly in a structured chimera grid approach is studied. The grid assembly process, involving hole cutting and searching donor, is parallelized on the PC cluster. A message passing programming model based on the MPI library is implemented using the single program multiple data(SPMD) paradigm. The coarse-grained communication is optimized with the minimized memory allocation because that the parallel grid assembly can access the decomposed geometry data in other processors by only message passing in the distributed memory system such as a PC cluster. The grid assembly workload is based on the static load balancing tied to flow solver. A goal of this work is a development of parallelized grid assembly that is suited for handling multiple moving body problems with large grid size.

  • PDF

An Improvement in Synchronously Rotating Reference Frame-Based Voltage Sag Detection under Distorted Grid Voltages

  • Sillapawicharn, Yutthachai;Kumsuwan, Yuttana
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1283-1295
    • /
    • 2013
  • This study proposed an improvement in synchronously rotating reference frame-based voltage sag detection under distorted grid voltages. In the past, the conventional synchronously rotating reference frame (CSRRF)-based voltage sag detection was generally used in the voltage sag compensation applications. Its disadvantage is a long delay of detection time. The modified synchronously rotating reference frame (MSRRF)-based voltage sag detection is able to detect the voltage sag with only a short delay in detection time. However, its operation under distorted grid voltage conditions is unavailable. This paper proposed the improvement of modified synchronously rotating reference frame (IMSRRF)-based voltage sag detection for use in distorted grid voltages with very fast operation of voltage sag detection. The operation of the proposed voltage sag detections is investigated via simulations and experimentations to verify the performance of the IMSRRF-based voltage sag detection.