• Title/Summary/Keyword: grid voltage

Search Result 1,134, Processing Time 0.027 seconds

A Study on the Optimization for a V-groove GMA Welding Process Using a Dual Response Method (듀얼 반응표면법을 이용한 V-그루브 GMA 용접공정 최적화에 관한 연구)

  • Park, Hyoung-Jin;Ahn, Seung-Ho;Kang, Mun-Jin;Rhee, Se-Hun
    • Journal of Welding and Joining
    • /
    • v.26 no.2
    • /
    • pp.85-91
    • /
    • 2008
  • In general, the quality of a welding process tends to vary with depending on the work environment or external disturbances. Hence, in order to achieve the desirable quality of welding, we should have the optimal welding condition that is not significantly affected by these changes in the environment or external disturbances. In this study, we used a dual response surface method in consideration of both the mean output variables and the standard deviation in order to optimize the V-groove arc welding process. The input variables for GMA welding process with the dual response surface are welding voltage, welding current and welding speed. The output variables are the welding quality function using the shape factor of bead geometry. First, we performed welding experiment on the interested area according to the central composite design. From the results obtained, we derived the regression model on the mean and standard deviation between the input and output variables of the welding process and then obtained the dual response surface. Finally, using the grid search method, we obtained the input variables that minimize the object function which led to the optimal V-groove arc welding process.

A Study on Future System Construction Using WSCR Strengthness Index based on Python (Python 기반 WSCR 강건 지수를 이용한 미래계통 구축에 관한 연구)

  • Park, Seong-Jun;Hur, Jin;Kim, Hyun-Jin;Cho, Yoon-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.994-1001
    • /
    • 2018
  • In this paper, to studied about future power system construction using PSS / E-Python API. Python-based future system automatical construction methods and modeling of renewable sources. it confirmed the stability of the powert system for each renewable area by calculating the weighted short circuit ratio (WSCR) index. it calculated the short circuit ratio (SCR) and selected the transmission line linkage scenario to improve the stability of vulnerable areas. it confirmed the WSCR index improvement through the selected transmission line linkage of scenario, and analyzed the stability of the renewable power system applying the scenario. It describes Facts and Shunt devices adjustment for the load flow convergence. It describes the stable methed of the bus voltage through the transformer Ratio Tap adjustment. By performing PSS/E ASCC using the Python it was performed three-phase short circuit fault capacity analysis, it is confirmed whether excess of the fault current circuit breaker capacity. In order to contingency accident analysis, it have described the generation of one or two line list of each areas using the Python. The list is used to contingency analysis and describe the soluted of the transmission line overload through comparison before and after adding the scenario line.

Dipole Antennas and Radiation Patterns in the Three-Dimensional GPR Modeling (쌍극자 안테나를 고려한 3차원 지표레이다 탐사 모델링과 방사 패턴에 대한 고찰)

  • Choi Yun-Gyoung;Seo1 Soon-Jee;Suh Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.4 no.2
    • /
    • pp.45-54
    • /
    • 2001
  • A three-dimensional finite difference time-domain modeling algorithm based on staggered grid and considering transmitting and receiving antennas has been developed to simulate Ground Penetrating Radar (GPR) survey. This algorithm adopted the subcellular method to simulate the dipole antennas being used in GPR system and added resistors to reduce ringing caused by the reflections at the ends of an antenna. Comparison of the output voltages in the presence of the resistors for half-space said that the ringing and the amplitude of output voltage decreased as the number of resistors increased, and the antenna was designed based upon this result. Radiation patterns were derived to understand the distribution of electric field energy in the planes including or normal to the antenna. The electric field energy concentrated on vertical direction in the plane including antenna more than in normal plane.

  • PDF

A Study on the Low Power Line Modulation and Power Line Channel Modeling (저압 전력선 통신 변조 기법 및 전력선 채널 특성)

  • Kand Duk-Ha;Heo Yoon-Seok;Cho Ki-Hyung;Lee Dae-Young
    • The Journal of Information Technology
    • /
    • v.5 no.4
    • /
    • pp.1-8
    • /
    • 2002
  • This thesis is about power line communication(PLC) over the low voltage grid. The main advantage with power line communication is the use of an existing infrastructure. The PLC channel can be modeled as having multi-path propagation with frequency-selective fading, typical power lines exhibit signal attenuation increasing with length and frequency. OFDM(Orthogonal Frequency Division Multiplexing) is a modulation technique where multiple low data rate carriers are combined by a transmitter to form a composite high data rate transmission. To implement the multiple carrier scheme using a bank of parallel modulators would not be very efficient in analog hardware. Each carrier in an OFDM is a sinusoid with a frequency that is an integer multiple of a base or fundamental sinusoid frequency. Therefore, each carrier is a like a Fourier series component of the composite signal. In fact, it will be shown later that an OFDM signal is created in the frequency domain, and then transformed into the time domain via the Discrete Fourier Transform(DFT).

  • PDF

Linearity Optimization of DC CT and a Study on the Application of HVDC System (HVDC DC CT 선형성 최적화 및 시스템 적용에 대한 연구)

  • Choi, Yong-Kil;Lee, Eun-Jae;Choi, Ho-Seok;Lee, Wook-Hwa
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.6
    • /
    • pp.758-763
    • /
    • 2014
  • These days, the advantages of DC power system are consistently stand out in korea that was a small power loss and high stability. Needs of DC power transmission technology is focused In the midst of a smart grid and environment friendly generation technology boom that is needed for next generation technology. Researches and businesses for HVDC(High Voltage Direct Current) system has been began. But, Needs of HVDC equipment and system commissioning technology are not on the rise until now. In particular, South Korea's HVDC technology is after the foot runner of advanced country and company. In addition, There is no experience for equipment verification and commissioning technology. And Experts of HVDC are rare. Who has been fully understood hardware and system as a whole, and identified all the equipment's characteristic. Recently, Academia and industry are recognized a needs of HVDC technology. But it does not received a recognition of technical value. In this paper, introduce issues when we apply the IEEE's verification method for HVDC system, especially DC current measurement system, DC CT(Direct Current Transformer), among the HVDC equipments. And Proposes remedial methods on the issue in order to recognize the necessity that was HVDC equipments's verification and commissioning technology research should be focused on.

Electroless plating of buried contact solar cell (전극함몰형 태양전지의 무전해도금)

  • Dong Seop Kim;Eun Chel Cho;Soo Hong Lee
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.6 no.1
    • /
    • pp.88-97
    • /
    • 1996
  • The metallization is the key to determining cell costs, cell performance, and system reliability. Screen printing technology suffers from several limitations affecting mainly the front grid. The buried contact solar cell (BCSC) was specifically desinged to be compatible with low cost, mass production techniques and avoid the conventional metallization problem. By using electroless plating technique, we performed this metallization inexpensively and reliably. This paper presents the details of the optimization procedure of metallization schemes on laser grooved cell surfaces. Commercially available Ni, Cu and Ag plating solutions were applied for the cell metallization. The application of those solutions on the buried contact front metallization has resulted in an cell efficiency of 18.8%. The cell parameters are an open circuit voltage of 651 mV, short circuit current density of 37.1 mA/$\textrm{cm}^2$, and fill factor of 77.8 %. The efficiency of over 18 % was achieved in the above 90% of the batch.

  • PDF

Development and Test of a Cooling System for a 154 kV Superconducting Fault Current Limiter

  • Kim, Heesun;Han, Young Hee;Yang, Seong-Eun;Yu, Seung-Duck;Park, Byung Jun;Park, Kijun;Yoo, Jaeun;Kim, Hye-Rim;In, Sehwan;Hong, Yong Joo;Yeom, Hankil
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.141-144
    • /
    • 2015
  • The superconducting fault current limiter (SFCL) is an electric power device that limits the fault current immediately in a power grid. Korea Electric Power Corporation (KEPCO) has been developing a 154 kV, 2 kA SFCL since 2011 to protect power grids from increasing fault current and improve the stability and quality of electric power. This SFCL adopts 2G YBCO wires and operates at 71 K and 5 bars. In this paper, a cooling system for the 154 kV SFCL and its cooling test results are reported. This cooling system uses a Stirling-type cooler to make sub-cooled liquid nitrogen ($LN_2$), which cools the superconductor modules of the SFCL. The $LN_2$ is circulated between the cooler and the cryostat that contains superconductor modules. The $LN_2$ also plays the role of a high voltage insulator between the modules and the cryostat, so the pressure was maintained at 5 bars for high insulation performance. After installation in a test site, the cooling characteristics of the system were tested. In this operation test, some important data were measured such as temperature distribution in $LN_2$, pressure change, performance of the heat exchanger, and cooling capacity of the total system. Consequently, the results indicate that the cooling system operates well as designed.

저압 전력선 채널 특성을 고려한 OFDM변조 전송

  • Kang Duk-Ha;Heo Yoon-Seok;Cho Ki-Hyung;Lee Dae-Young
    • The Journal of Information Technology
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 2003
  • This paper is about power line communication(PLC) over the low power voltage grid. The main advantage with power line communication is the use of an existing infrastructure. The PLC channel can be modeled as having multi-path propagation with frequency-selective fading, typical power lines exhibit signal attenuation increasing with length and frequency. OFDM(Orthogonal Frequency Division Multiplexing) is a modulation technique where multiple low data rate carriers are combined by a transmitter to form a composite high data rate transmission. To implement the multiple carrier scheme using a bank of parallel modulators would not be very efficient in analog hardware. Each carrier in an OFDM is a sinusoid with a frequency that is an integer multiple of a base or fundamental sinusoid frequency. Therefore, each carrier is a like a Fourier series component of the composite signal. In fact, it will be shown later that an OFDM signal is created in the frequency domain, and then transformed into the time domain via the Discrete Fourier Transform(DFT).

  • PDF

Supercapacitor Energy Storage System for the Compensation of Fuel Cell Response Characteristics (연료전지 응답특성 보상용 슈퍼커패시터 에너지 저장 시스템)

  • Song, Woong-Hyub;Jung, Jae-Hun;Kim, Jin-Young;Nho, Eui-Cheol;Kim, In-Dong;Kim, Heung-Geun;Chun, Tae-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.440-447
    • /
    • 2011
  • This paper deals with supercapacitor energy storage system for the compensation of the slow response characteristics of a fuel cell generation system for grid connection. A bidirectional dc/dc converter is used for the charging and discharging of the supercapacitor. The conventional converters use additional clamping circuit, etc. to reduce a voltage spike at the instant of switching and to provide wide range of soft switching. The proposed method provides simplified hardware implementation without any clamping circuit, and soft switching condition for both charging and discharging mode with proper switching patterns. The usefulness of the proposed scheme is verified through simulation and experimental results with 1 kW system.

A Study on Power Factor Control of Inverter-based DG System with Considering the Capacity of an Active Harmonic Filter and an Inverter (고조파 필터 및 인버터의 용량을 고려한 분산전원 시스템의 역률 제어에 관한 연구)

  • Kim, Young-Jin;Hwang, Pyeong-Ik;Moon, Seung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2149-2154
    • /
    • 2009
  • Electric power quality in power transmission/distribution systems has considerably been deteriorated with the increase in the capacity of distributed generators (DGs). It is because inverters, connecting DGs to conventional power grids, tend to generate harmonic current and voltage. For harmonic mitigation, a large amount of research has been done on passive and active filters, which have been operating successfully in many countries. This paper, therefore, presents how to adopt the filters to an inverter-based DG, with considering a system consisting of both inverter-based DG and harmonic filters. In particular, this paper describes the simulation results using the PSCAD/EMTDC: firstly, the relationship between total harmonic distortion(THD) of current and output power of DG: secondly, the harmonic mitigation ability of passive and active filters. The system, furthermore, is obliged to satisfy the regulations made by Korean Electric Power Corporation(KEPCO). In the regulations, power factor should be maintained between 0.9 and 1 in a grid-connected mode. Thus, this paper suggests two methods for the system to control its power factor. First, the inverter of DG should control power factor rather than an active filter because it brings dramatic decrease in the capacity of the active filter. Second, DG should absorb reactive power only in the range of low output power in order to prevent useless capacity increase of the inverter. This method is expected to result in the variable power factor of the system according to its output power.