• 제목/요약/키워드: grid voltage

검색결과 1,134건 처리시간 0.028초

Development and Testing of a 10 kV 1.5 kA Mobile DC De-Icer based on Modular Multilevel Converter with STATCOM Function

  • Hu, Pengfei;Liang, Yiqiao;Du, Yi;Bi, Renming;Rao, Chonglin;Han, Yang
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.456-466
    • /
    • 2018
  • This paper introduces the development of a de-icer based on a full-bridge modular multilevel converter (FMMC). The FMMC can generate a wide range of DC voltages owing to its modularity, scalability, and redundancy, which makes it suitable for ice-melting applications. First, operating principles and voltage ranges are analyzed when FMMC is applied as a mobile de-icer. Second, two new startup strategies, constant modulation index and constant power startup strategies, are proposed. Third, the main control strategies of the de-icer are proposed. Fourth, a novel rated-current zero-power test scheme is proposed to simplify test conditions. Finally, a 10 kV 1.5 kA mobile MMC de-icer is designed and built, and experiments are carried out to validate the proposed startup, control strategies, and rated-current zero-power test scheme.

ESS 배터리 충방전 시스템을 위한 8kW급 LLC 절연형 컨버터 설계 (8kW LLC Isolated Converter Design for ESS Battery Charge/Discharge System)

  • 김진우;백승훈;조영훈;구태근
    • 전력전자학회논문지
    • /
    • 제23권3호
    • /
    • pp.161-167
    • /
    • 2018
  • In battery-operated systems, an isolated converter is used to interface the utility grid with the system to increase stability when charging and discharging batteries. Systems such as vehicle-to-grids (V2Gs), on-board chargers, and energy storage systems (ESSs) have recently become popular, and the roles of isolated converters have become important considerations in fabricating such devices. A fixed-frequency LLC converter, which is a type of isolated converter, presents the advantages of high efficiency and high power density by performing zero-voltage switching (ZVS) over wide frequency ranges. However, the magnetizing inductance of the LLC converter should be designed to enable ZVS in all switching devices. Therefore, in this study, the operating characteristics of the LLC circuit are analyzed, and an optimal design method for ZVS operation is established. Moreover, an 8 kW LLC high-efficiency and high-power-density resonant converter is designed and tested for ESS application. The LLC converter achieves 98% efficiency at rated power.

A New Reclosing and Re-breaking DC Thyristor Circuit Breaker for DC Distribution Applications

  • Kim, Jin-Young;Choi, Seung-Soo;Kim, In-Dong
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.272-281
    • /
    • 2017
  • The DC circuit breaker is essential for supplying stable DC power with the advent of DC transmission/distribution and sensitive loads. Compared with mechanical circuit breakers, which must interrupt a very large fault current due to their slow breaking capability, a solid-state circuit breaker (SSCB) can quickly break a fault current almost within 1 [ms]. Thus, it can reduce the damage of an accident a lot more than mechanical circuit breakers. However, previous DC SSCBs cannot perform the operating duty, and are not economical because many SCR are required. Therefore, this paper proposes a new DC SSCB suitable for DC grids. It has a low semiconductor conduction loss, quick reclosing and rebreaking capabilities. As a result, it can perform the operating duties of reclosing and rebreaking. The proposed DC SSCB is designed and implemented so that it is suitable for home dc distribution at a rated power of 5 [kW] and a voltage of 380 [V]. The operating characteristics are confirmed by simulation and experimental results. In addition, this paper suggests design guidelines so that it can be applied to other DC grids. It is anticipated that the proposed DC SSCB may be utilized to design and realize many DC grid systems.

Protection of the MMCs of HVDC Transmission Systems against DC Short-Circuit Faults

  • Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.242-252
    • /
    • 2017
  • This paper deals with the blocking of DC-fault current during DC cable short-circuit conditions in HVDC (High-Voltage DC) transmission systems utilizing Modular Multilevel Converters (MMCs), where a new SubModule (SM) topology circuit for the MMC is proposed. In this SM circuit, an additional Insulated-Gate Bipolar Translator (IGBT) is required to be connected at the output terminal of a conventional SM with a half-bridge structure, hereafter referred to as HBSM, where the anti-parallel diodes of additional IGBTs are used to block current from the grid to the DC-link side. Compared with the existing MMCs based on full-bridge (FB) SMs, the hybrid topologies of HBSM and FBSM, and the clamp-double SMs, the proposed topology offers a lower cost and lower power loss while the fault current blocking capability in the DC short-circuit conditions is still provided. The effectiveness of the proposed topology has been validated by simulation results obtained from a 300-kV 300-MW HVDC transmission system and experimental results from a down-scaled HVDC system in the laboratory.

태양광용 부스트 컨버터의 2중 루프 제어 및 단일 루프 제어의 특성 비교 (Comparative Study between Two and Single-loop Control of Boost Converter for PVPCS)

  • 김동환;임지훈;송승호;최주엽;안진웅;이상철;이동하
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.153-159
    • /
    • 2012
  • In photovoltaic system, the characteristic of photovoltaic module such as open circuit voltage and short circuit current will be changed because of cell temperature and solar radiation. Therefore, a boost converter of the PV system connects between the output of photovoltaic system and DC link capacitor of grid connected inverter as controlling duty ratio for maximum power point tracking(MPPT). This paper shows the dynamic characteristic of the boost converter by comparing single-loop control algorithm and two-loop control algorithm using both analog and digital control. The proposed both compensation method has been verified with computer simulation and simulation results obtained demonstrate the validity of the proposed control schemes.

  • PDF

대용량 태양광 발전용 멀티센트럴 시스템 (Multi-Central System for Large Scale PV Power Generation)

  • 박종형;고광수;김흥근;노의철;전태원
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.427-432
    • /
    • 2012
  • This paper proposes efficient operation method of PV system consisted of multi-central which is suitable for large scale system. The multi-central system used switch at a DC-link and applied proposed algorithm can improve the efficiency and the reliability on the existing system. This algorithm, with advantage of Multi-Central system can minimize the effect of different characteristic of each PV array due to a shadow or damaged PV cell. Each system is analysed and maximum power point tracking control, DC-link voltage control and output current control is used commonly. The validity is verified after comparing of the existing system and proposed system by simulation.

  • PDF

풍력발전기의 출력 안정화를 위한 에너지 저장장치 용량 산정 사례연구 (Analysis on Required Capacity of Energy Storage System to Mitigate Wind Power Fluctuation)

  • 강민혁;채상헌;안진홍;김일환
    • 한국태양에너지학회 논문집
    • /
    • 제37권6호
    • /
    • pp.59-68
    • /
    • 2017
  • In accordance with the policy of local government, the large scale of wind farms have been installed in Jeju power system. However, The intermittent characteristics of wind power output may cause grid voltage and frequency variation, especially in weak power system. One of the solution to solve this problem is installation of Energy storage system (ESS). In this case, the ESS will regulate the active power generated from wind farm to mitigate fluctuation. Actually, the local government of Jeju island constructed ESS connected to Hangwon wind turbine in 2016. From this point, this paper analyzes requirement capacity of ESS to mitigate wind power fluctuation based on measured data from Hangwon wind turbine and ESS. The simulation results will be carried out by Matlab program.

전력선 채널에서 음향신호의 OFDM 변조 전송 특성 (OFDM Modulation Transmission Characteristic of Acoustic Signal on Power Line Channel)

  • 허윤석
    • 정보학연구
    • /
    • 제6권4호
    • /
    • pp.1-9
    • /
    • 2003
  • 본 연구는 저압 전력선 망을 통한 전력선 통신(PLC: Power Line Communication)에 관한 내용이다. 전력선 통신이 가지는 주요 잇점은 기존의 인프라구조의 사용이다. 전력선 통신 채널은 전형적으로 전력선의 길이와 주파수가 증가함에 의해 신호 감쇠를 나타내는 주파수 선택적 페이딩(Frequency-Selective Fading)을 가지는 다중경로 반사 전파로 모델링 할 수 있다. OFDM(Orthogonal Frequency Division Multiplexing)은 다수개의 낮은 데이터 율의 반송파들이 높은 전송율을 이루는 형태로 송신기에서 조합되는 변조 기법이다. 모델링한 다중 경로 반사 전력선 채널에 음향 신호를 입력하여 체계의 성능을 모의 실험을 통해 분석, 검증하였다.

  • PDF

풍력발전 계통연계시 선로정수에 따른 계통 영향 분석 (Influence Analysis of Grid Connected Wind Power Generator by Line Constants)

  • 최영도;곽노홍;전영수;전동훈;한병문;윤동진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.249-250
    • /
    • 2008
  • 본 논문은 고창 전력품질 실증시험장에서 실 계통 연계를 위해 시험 중인 1.5M급 풍력발전 시뮬레이터의 선로정수를 PSCAD/EMTDC를 이용하여 모의하고 선로정수에 따른 풍력발전시스템이 계통에 미치는 영향을 분석하는데 중점을 두었다. 현재 고창에 설치되어있는 전력품질 실증시험장은 22.9kV 급전선에 SSTS(Synchronous Static Transfer Switch)의 한쪽 스위치로 직접 연결되어있으며 다른 한 쪽은 전력계통에서 발생되는 다양한 형태의 이벤트를 발생시키는 SSHG(Sag Swell Harmonics Generator)를 통하여 연결되어있다. 전력품질 향상기기중 하나인 DVR(Dynamic Voltage Restorer)는 SSTS의 부하쪽으로 직렬로 연결되어있으며 delta-wye 변압기를 통해 정류기 부하와 APF(Active Power Filter), 그리고 순저항부하와 유도성부하가 연결되어 있고 또한 SSHG를 통하여 연결된 배전선에는 DSTATCOM(Distribution Static Compensator)가 병렬로 연결되어있다. 본 논문에서는 고창에 있는 풍력발전 시뮬레이터와 동일하게 PSCAD/EMTDC로 구성하였으며 선로정수를 모델링 하기 위해 선로모델을 10Km, 20Km, 30Km, 40Km,로 설정하여 선로정수에 따른 계통영향을 분석하여 풍력발전 시뮬레이터에서 모의가능 한 선로정수 값을 제시한다.

  • PDF

PV Output Sensorless(POS) MPPT법이 적용된 3상 계통연계형 태양광 발전시스템의 특성해석 (The characteristic analysis of POS (PV Output Sensorless) MPPT based 3 phase grid connected PV system)

  • 박상수;김경훈;김상용;장성재;서효룡;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1081-1082
    • /
    • 2008
  • Photovoltaic (PV) power generation system has been widely studied as a clean and renewable power source. The purpose of this study is to keep the output power of photovoltaic cells maximum under any weather conditions. There are so many MPPT (Maximum Power Point Tracking) methods. P&O method has been used as a key MPPT method, both voltage and current coming out from PV array have to be feedback in the method. Thus, the system has a complex structure, and may fail to track MPP of PV array when unexpected weather conditions happen. In order to reduce the feedback components, POS MPPT control method was proposed by the authors. In this paper, the authors apply the POS MPPT control method to three phase PCS system. And the effectiveness of the proposed control scheme is demonstrated through PSCAD/EMTDC simulation.

  • PDF