• 제목/요약/키워드: grid model

검색결과 2,483건 처리시간 0.032초

GCI와 벽면격자거리를 고려한 2차원 분사유동의 검증 (VERIFICATION OF 2D INJECTION FLOWS WITH GCI AND NEAR-WALL GRID LINE SPACINGS)

  • 원수희;정인석;최정열
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 추계 학술대회논문집
    • /
    • pp.287-292
    • /
    • 2005
  • The flowfields generated by gaseous slot injection into a supersonic flow at a Mach number of 3.75 and a Reynolds number of $2.07{\times}10^7$ are simulated numerically. Fine-scale turbulence effects are represented by a two-equation(k-w SST model) closure model which includes $y^+$ effects on the turbulence model. Grid convergence index(GCI) is also considered to provide a measure of uncertainty of the grid convergence. Comparison is made with experimental data and other turbulence model in term of surface static pressure distributions, the length of the upstream separation region, and the penetration height. Results indicate that the k-w SST model correctly predicts mean surface pressure distribution and upstream separation length. However, it is also observed that the numerical simulation over predicts the pressure spike and penetration height compared with experimental data. All these results are taken within $1\%$ error band of grid convergence.

  • PDF

과냉 비등유동에 대한 CFD 모의 계산에서의 벽 인접격자 영향 (NEAL-WALL GRID DEPENDENCY OF CFD SIMULATION FOR A SUBCOOLED BOILING FLOW)

  • 인왕기;신창환;전태현
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.320-325
    • /
    • 2010
  • A multiphase CFD analysis is performed to investigate the effect of near-wall grid for simulating a subcooled boiling flow in vertical tube. The multiphase flow model used in this CFD analysis is the two-fluid model in which liquid(water) and vapor(steam) are considered as continuous and dispersed fluids, respectively. A wall boiling model is also used to simulate the subcooled boiling heat transfer at the heated wall boundary. The diameter and heated length of tube are 0.0154 m and 2 m, respectively. The system pressure in tube is 4.5 MPa and the inlet subcooling is 60 K. The near-wall grid size in the non-dimensional wall unit ($y_{w}^{+}$) was examined from 64 to 172 at the outlet boundary. The CFD calculations predicted the void distributions as well as the liquid and wall temperatures in tube. The predicted axial variations of the void fraction and the wall temperature are compared with the measured ones. The CFD prediction of the wall temperature is shown to slightly depend on the near-wall grid size but the axial void prediction has somewhat large dependency. The CFD prediction was found to show a better agreement with the measured one for the large near-wall grid, e.g., $y_{w}^{+}$ > 100.

  • PDF

격자기반 운동파 강우유출모형 KIMSTORM의 개선(I) - 이론 및 모형 - (A Modified grid-based KIneMatic wave STOrm Runoff Model (ModKIMSTORM) (I) - Theory and Model -)

  • 정인균;이미선;박종윤;김성준
    • 대한토목학회논문집
    • /
    • 제28권6B호
    • /
    • pp.697-707
    • /
    • 2008
  • 격자기반 운동파 강우유출모형 KIMSTORM(grid-based KIneMatic wave STOrm Runoff Model)은 유역의 지표흐름, 지표하흐름 및 하천흐름의 시간적 변화와 공간적 분포를 모의할 수 있다. 본 모형은 유닉스 운영체제의 C++언어로 개발되었으며, 각 셀에서의 흐름을 모의하기 위하여 단방향흐름 알고리즘과 격자기반 수문학적 물수지요소를 채택하고 있으나 운영에 몇몇 제약사항이 있다. 본 연구에서는 기존모형을 개선하고자 하였으며, MS Windows 운영체제에서 실행 가능하도록 FORTRAN 90 언어를 이용하여 ModKIMSTORM을 개발하였다. 기존모형에 비해 개선된 주요사항으로, 물리적 기반의 침투기법인 GAML(Green-Ampt & Mein-Larson) 침투모형 추가, 격자 유출심과 Manning 조도계수에 의한 논에서의 지표유출 제어, 지표격자의 기저유출 요소 추가, 공간강우와 지점강우의 처리, 전 후 처리부문 개발, 5개 평가항목(피어슨의 결정계수 $R^2$, Nash & Sutcliffe 모형효율 E, 유출용적 편차 $D_v$, 첨두유출의 상대오차 $EQ_p$, 첨두시간의 절대오차 $ET_p$)을 이용한 모의결과의 자동 평가 기능을 개발하였다. 추가적으로, 모형의 계산효율을 향상시키고 지표격자의 기저유출을 하천격자로 이송하기 위하여 쉘정렬 알고리즘을 채택하였다. 모형의 입력자료는 ESRI ArcInfo W/S 또는 ArcView와 같은 GIS 소프트웨어 및 MS Excel을 이용하여 간단히 구축할 수 있으며, 모의결과의 공간적 분포를 확인할 수 있는 토양수분, 지표유출, 유출심 및 유속분포도는 BSQ, ESRI ASCII Grid, ESRI Binary Grid 및 IDRISI Raster 형식으로 출력할 수 있도록 개선하였다.

Power Loss and Junction Temperature Analysis in the Modular Multilevel Converters for HVDC Transmission Systems

  • Wang, Haitian;Tang, Guangfu;He, Zhiyuan;Cao, Junzheng
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.685-694
    • /
    • 2015
  • The power loss of the controllable switches in modular multilevel converter (MMC) HVDC transmission systems is an important factor, which can determine the design of the operating junction temperatures. Due to the dc current component, the approximate calculation tool provided by the manufacturer of the switches cannot be used for the losses of the switches in the MMC. Based on the enabled probabilities of each SM in an arm, the current analytical models of the switches can be determined. The average and RMS currents can be obtained from the corresponding current analytical model. Then, the conduction losses can be calculated, and the switching losses of the switches can be estimated according to the upper limit of the switching frequency. Finally, the thermal resistance model of the switches can be utilized, and the junction temperatures can be estimated. A comparison between the calculation and PSCAD simulation results shows that the proposed method is effective for estimating the junction temperatures of the switches in the MMC.

New Control Scheme for the Wind-Driven Doubly Fed Induction Generator under Normal and Abnormal Grid Voltage Conditions

  • Ebrahim, Osama S.;Jain, Praveen K.;Nishith, Goel
    • Journal of Power Electronics
    • /
    • 제8권1호
    • /
    • pp.10-22
    • /
    • 2008
  • The wind-driven doubly fed induction generator (DFIG) is currently under pressure to be more grid-compatible. The main concern is the fault ride-through (FRT) requirement to keep the generator connected to the grid during faults. In response to this, the paper introduces a novel model and new control scheme for the DFIG. The model provides a means of direct stator power control and considers the stator transients. On the basis of the derived model, a robust linear quadratic (LQ) controller is synthesized. The control law has proportional and integral actions and takes account of one sample delay in the input owing to the microprocessor's execution time. Further, the influence of the grid voltage imperfection is mitigated using frequency shaped cost functional method. Compensation of the rotor current pulsations is proposed to improve the FRT capability as well as the generator performance under grid voltage unbalance. As a consequence, the control system can achieve i) fast direct power control without instability risk, ii) alleviation of the problems associated with the DFIG operation under unbalanced grid voltage, and iii) high probability of successful grid FRT. The effectiveness of the proposed solution is confirmed through simulation studies on 2MW DFIG.

Parameter Identification of 3R-C Equivalent Circuit Model Based on Full Life Cycle Database

  • Che, Yanbo;Jia, Jingjing;Yang, Yuexin;Wang, Shaohui;He, Wei
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1759-1768
    • /
    • 2018
  • The energy density, power density and ohm resistance of battery change significantly as results of battery aging, which lead to decrease in the accuracy of the equivalent model. A parameter identification method of the equivale6nt circuit model with 3 R-C branches based on the test database of battery life cycle is proposed in this paper. This database is built on the basis of experiments such as updating of available capacity, charging and discharging tests at different rates and relaxation characteristics tests. It can realize regular update and calibration of key parameters like SOH, so as to ensure the reliability of parameters identified. Taking SOH, SOC and T as independent variables, lookup table method is adopted to set initial value for the parameter matrix. Meanwhile, in order to ensure the validity of the model, the least square method based on variable forgetting factor is adopted for optimizing to complete the identification of equivalent model parameters. By comparing the simulation data with measured data for charging and discharging experiments of Li-ion battery, the effectiveness of the full life cycle database and the model are verified.

통합 재해지도 작성 기법 개발(I) : 그리드 기반 모형의 확장 및 검증 (Development of integrated disaster mapping method (I) : expansion and verification of grid-based model)

  • 박준형;한건연;김병현
    • 한국수자원학회논문집
    • /
    • 제55권1호
    • /
    • pp.71-84
    • /
    • 2022
  • 본 연구의 목적은 간단한 입력자료로 정확한 홍수해석을 수행할 수 있는 2차원 침수모형을 개발하는데 있다. 현재 침수예상도 작성을 위해 사용되는 2차원 침수해석 모형들은 복잡한 입력자료 및 격자 생성 도구를 필요로 한다. 이는 때때로 침수 모델링을 위해 많은 시간과 노력이 요구되며, 상황에 따라서는 입력자료의 구축에 어려움이 있을 수도 있다. 이러한 단점들을 보완하기 위해, 본 연구에서는 정확한 지형자료를 간단한 입력자료로 반영하여, 정확하고 신속한 침수해석을 도출할 수 있는 그리드 기반 모형을 개발하였다. 기존의 2×2 Sub-grid 모형을 5×5 Sub-grid까지 확장하여 계산의 효율성을 개선하였다. 모형의 정확성 및 적용성을 검토하기 위해, 태풍 루사로 인해 내수침수와 외수범람이 동시에 발생한 감천유역에 적용하였다. 사용자의 선택에 따른 효율적인 홍수분석을 위해, 격자 크기와 Sub-grid 개수에 따른 홍수파 전파양상, 침수해석의 정확성, 모형의 수행시간을 조사하였다. 개발된 모형은 정확한 침수해석 결과를 보여주는 침수예상도에서부터 대략적인 침수여부만을 보여주는 홍수위험도까지 다양한 상황에 맞는 침수해석 결과를 제시할 수 있으며, 재해지도 작성에도 활용성이 높을 것으로 기대된다.

Grid Based Nonpoint Source Pollution Load Modelling

  • Niaraki, Abolghasem Sadeghi;Park, Jae-Min;Kim, Kye-Hyun;Lee, Chul-Yong
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 한국공간정보시스템학회 2007년도 GIS 공동춘계학술대회 논문집
    • /
    • pp.246-251
    • /
    • 2007
  • The purpose of this study is to develop a grid based model for calculating the critical nonpoint source (NPS) pollution load (BOD, TN, TP) in Nak-dong area in South Korea. In the last two decades, NPS pollution has become a topic for research that resulted in the development of numerous modeling techniques. Watershed researchers need to be able to emphasis on the characterization of water quality, including NPS pollution loads estimates. Geographic Information System (GIS) has been designed for the assessment of NPS pollution in a watershed. It uses different data such as DEM, precipitation, stream network, discharge, and land use data sets and utilizes a grid representation of a watershed for the approximation of average annual pollution loads and concentrations. The difficulty in traditional NPS modeling is the problem of identifying sources and quantifying the loads. This research is intended to investigate the correlation of NPS pollution concentrations with land uses in a watershed by calculating Expected Mean Concentrations (EMC). This work was accomplished using a grid based modelling technique that encompasses three stages. The first step includes estimating runoff grid by means of the precipitation grid and runoff coefficient. The second step is deriving the gird based model for calculating NPS pollution loads. The last step is validating the gird based model with traditional pollution loads calculation by applying statistical t-test method. The results on real data, illustrate the merits of the grid based modelling approach. Therefore, this model investigates a method of estimating and simulating point loads along with the spatially distributed NPS pollution loads. The pollutant concentration from local runoff is supposed to be directly related to land use in the region and is not considered to vary from event to event or within areas of similar land uses. By consideration of this point, it is anticipated that a single mean estimated pollutant concentration is assigned to all land uses rather than taking into account unique concentrations for different soil types, crops, and so on.

  • PDF

벽 비등모델을 이용한 과냉비등 유동에 대한 CFD 모의계산에서 벽 인접격자의 영향 (NEAR-WALL GRID DEPENDENCY OF CFD SIMULATION FOR A SUBCOOLED BOILING FLOW USING WALL BOILING MODEL)

  • 인왕기;신창환;전태현
    • 한국전산유체공학회지
    • /
    • 제15권3호
    • /
    • pp.24-31
    • /
    • 2010
  • boiling flow in vertical tube. The multiphase flow model used in this CFD analysis is the two-fluid model in which liquid(water) and gas(vapour) are considered as continuous and dispersed fluids, respectively. A wall boiling model is also used to simulate the subcooled boiling heat transfer at the heated wall boundary. The diameter and heated length of tube are 0.0154 m and 2 m, respectively. The system pressure in tube is 4.5 MPa and the inlet subcooling is 60 K. The near-wall grid size in the non-dimensional wall unit for lqiuid phase ($y^+_{w,l}$) was examined from 101 to 313 at the outlet boundary. The CFD calculations predicted the void distributions as well as the liquid and wall temperatures in tube. The predicted axial variations of the void fraction and the wall temperature are compared with the measured ones. The CFD prediction of the wall temperature is shown to slightly depend on the near-wall grid size but the axial void prediction has somewhat large dependency. The CFD prediction was found to show a better agreement with the measured one for the large near-wall grid, e.g., $y^+_{w,l}$ > 300 at the tube exit.