• Title/Summary/Keyword: grid connection

Search Result 307, Processing Time 0.032 seconds

고주파링크 방식의 계통연계형 태양광발전시스템 (High frequency Linked Grid-Connected PV System for Residential Use)

  • 정영석;유권종;이수홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1281-1283
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors a net size, weight, and parts cost saying result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

아크발생에 따른 태양광 인버터의 효율 특성 연구 (The Study Efficiency Characteristics of PV Inverter by Series Arc)

  • 김승열;서현욱;권완성;이영진;한동화;반충환;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 추계학술대회 논문집
    • /
    • pp.159-160
    • /
    • 2012
  • For renewable energy has been studied by many research. among them, non-pollution and infinite solar energy using solar power system is newly spotlighed. the DC output characteristic of the solar cell, connection to grid and using the inverter is essential to the process of converter DC to AC. in this paper, study the corresponding changes in the efficiency of the inverter and arcing occurs in the inverter, depending on the conditions and regulations in the UL-1699 series arc occurs.

  • PDF

납 축전지 병렬운전시 발생하는 전류 불평형 현상분석 및 대책 (Unbalance load current of Operating in Parallel of Lead acid batteries connection condition)

  • 반한식;곽철훈;최규하;목형수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.210-213
    • /
    • 1999
  • A battery is the device that transforms the chemical energy into the direct-current electrical energy directly without a mechanical process. Unit cells are connected in series to obtain the necessary voltage, while being connected in parallel to organize capacity for load current and to decrease the internal resistance for corresponding the sudden shift of the load current. The circular-current, however, could be occurred when the system is driven in parallel. As a result, the new batteries are heated by over-change and discharge, and the over charge current makes to increase the rust of the positive grid and consequently the shortened life of the new batteris would be shown. In this paper, the internal resistance of charge and discharge will be balanced, through inserting the resistance into the system by way of calculation of the changed amount of internal resistance.

  • PDF

Sub-Synchronous Range of Operation for a Wind Driven Double-Fed Induction Generator

  • Saleh, Mahmoud Abdel Halim;Eskander, Mona Naguib
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.72-78
    • /
    • 2010
  • In this paper the operation of a double-fed wound-rotor induction machine, coupled to a wind turbine, as a generator at sub-synchronous speeds is investigated. A novel approach is used in the analysis, namely, the rotor power flow approach. The conditions necessary for operating the machine as a double-fed induction generator (DFIG) are deduced. Formulae describing the factors affecting the range of sub-synchronous speeds within which generation occurs are deduced. The variations in the magnitude and phase angle of the voltage injected to the rotor circuit as the speed of the machine changes to achieve generation at the widest possible sub-synchronous speed range is presented. Also, the effect of the rotor parameters on the generation range is presented. The analysis proved that the generation range could increase from sub-synchronous to super-synchronous speeds, which increases the amount of energy captured by the wind energy conversion system (WECS) as result of utilizing the power available in the wind at low wind speeds.

Development of an Unmanned Control System of Induction Generator for a Wave Power Plant

  • Hwan, Jeon-Bong;Lim, Yong-Kon;Hong, Seok-Won
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.74.5-74
    • /
    • 2001
  • The wave power plant is a generating system to convert the wave energy resources to electric energy. ´CHUJEON A´, which is a prototype of wave power plant developed by KORDI(Korea Ocean Research and Development Institute), has been launched for its performance test. A wound rotor induction machine is adopted as a generator for the power plant to acquire constant frequency and voltage over wide range of rotor speed. Because the generator of ´CHUJEON A´ has no connection to the power grid line on land, all of the processes to generate and consume the electricity have to be conducted on the floating plant. This paper deals with the design and implementation of the unmanned control system for ´CHUJEON A´. The system includes generator control system, power conversion and charging system, data acquisition and wireless communication system ...

  • PDF

STRUCTURAL INTEGRITY EVALUATION OF NUCLEAR FUEL WITH REDUCED WELDING CONDITIONS

  • Park, Nam-Gyu;Park, Joon-Kyoo;Suh, Jung-Min;Kim, Kyu-Tae;Jeon, Kyeong-Lak
    • Nuclear Engineering and Technology
    • /
    • 제41권3호
    • /
    • pp.347-354
    • /
    • 2009
  • Welding is required for a connection between two different components in the nuclear fuel of a pressurized water reactor. This work relies on a mechanical experiment and analytic results to investigate the structural integrity of nuclear fuel in a situation where some components are not welded to each other. A series of lateral vibration tests are performed in a test facility, and the test structures are examined in terms of dynamic behavior. In the tests, the displacement signal at every grid structure that sustains fuel rods is measured and processed to identify the dynamic properties. The fluid-elastic stability of the structure is also analyzed to evaluate susceptibility to a cross flow with an assumed conservative cross flow distribution. The test and analysis results confirm that the structural integrity can be maintained even in the absence of some welding connections.

2MW급 DFIG 최적 설계 및 성능 평가에 관한 연구 (The Performance Evaluation and the Optimal Design of 2MW DFIG)

  • 조성호;오영진;문병선;이승구
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.382-385
    • /
    • 2007
  • The optimal design and characteristic analysis of Double Fed Induction Generator(DFIG) was performed. The purpose of the paper is to verify the accuracy of design and the reliability of DFIG by experiment. A grid connection experiment is performed to confirm generating performance in wide operating range. In this experiment, 2.7MW M/G set is used. The finite element method is applied to calculate parameters and characteristic analysis of DFIG. And in order to reduce design time and efforts, Design of Experiment(DOE) is used. The experimental results are compared with the optimum design results.

  • PDF

3kW 계통연계형 태양광발전시스템의 운전특성 (The Operating Characteristics of 3kW Utility Interconnected Photovoltaic System)

  • 김형석;박정민;나종덕;백형래;조금배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.201-204
    • /
    • 2004
  • Consider the optimal design for PV system, it is apply to 3kW interconnected electric power PV system, that is a point of reference for 3kW PV the spread residential section system. Through the driving various practical system, we look into that for efficiency of generation and stability of interconnected system. Using obtained data acquisition, It can be suggest that installation and management for system parameter to optimal design maximum generation electric power. PV system have some losses that are variation radiation, shadow, change temperature, unbalanced grid connection, serial circuit loss, MPP deference loss, PCS loss and so forth. Using obtained various performance characteristic result, we can make database in the future, through the this study, we can get the reliance and have regard to spread PV system.

  • PDF

DVR의 특성을 고려한 매칭변압기의 자속포화 해석 (Magnetic Flux Saturation Analysis of Matching Transformer Considering Characteristic of Dynamic Voltage Restorer(DVR))

  • 손진근;김동준;강민구;전희종
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.236-243
    • /
    • 2008
  • This paper analyses magnetic flux saturation of matching transformer considering characteristic of dynamic voltage restorer(DVR) system to solve voltage sags which are considered the dominant disturbances affecting power quality. This DVR consist of PWM inverter to inject arbitrary voltage, LC low pass filter and matching transformer for isolation and grid connection. However, the matching transformer has an excess of inrush current by magnetic flux saturation in the core of transformer. Due to this inrush current, the rating of matching transformers is double for needed nominal rating for protection of DVR. Therefore, in this paper, an advanced modeling method of magnetic flux saturation is used to analyze a magnitude and characteristic of magnetizing current. Simulation and experimental results considering characteristic of DVR system are provided to demonstrate the validity of the proposed analysis method.

CNT 및 Pt을 상대전극으로 하는 DSSC의 직병렬연결에 관한 비교특성 (Comparative properties for a serial-parallel connection of DSSC with CNT and Pt counter electrodes)

  • 김희제;김정훈;박성준;최진영;홍지태;이동윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1236-1237
    • /
    • 2008
  • Carbon nanotube(CNT) materials are expected a stable current collector without the phenomena such as oxidizing and melting of grid by redox electrolyte and with low cost. In this paper, two types of dye-sensitized solar cells(DSSCs) with Pt abd CNT as a counter electrode were fabricated, then the energy conversion efficiency characteristics were investigated. The main purpose of this study is to find out the possibility of CNT material as cheap current collector of a large scale DSSC module. In addition, the Hall coefficient were measured by using FCM analysis.

  • PDF