• Title/Summary/Keyword: greenhouse test

Search Result 434, Processing Time 0.028 seconds

Reinforcement Method of a Long Span Plastic Greenhouse using Tension-tie (인장타이를 이용한 광폭형 비닐하우스의 보강법)

  • Shin, Kyung-Jae;Shin, Dong-Hui;Lee, Swoo-Heon;Chae, Seoung-Hun
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • A long-span (more than 8m) plastic greenhouse is currently being used in farms due to its magnified benefits, such as the convenience of the farming equipment used, and the land usage efficiency. In this study, the reinforcing effects of the use of a pretension tie were shown. In a previous study, tests for a 6.5m single-span-type greenhouse announced by Rural Development Administration were carried out. The tests of symmetric and eccentrics now loading by the sun and wind were conducted for the 10.2m span with a ${\phi}48.1{\times}2.1$ section in this study, after which the load-deflection relationship was compared for the cases of reinforcement with a tie and without a tie. The results of the symmetric snow loading test showed that the strength increased by 68~93% in the case of the specimen with a tied arch. The failure mode of the specimen without a tie tended to be that with a sway failure mechanism, and that of the reinforcement specimens with a tie tended to be that with an arch buckling mechanism. The results of the eccentric snow loading test showed that the strength of the specimen with a tie increased by 10~20% compared to that of the specimen without a tie. For the failure mode of the latter, a combined failure mechanism was adapted, although the failure mode of the tied specimens tended to be that with an arch buckling mechanism.

A Field Study on Electrokinetic Removal of Salts from Greenhouse Soil (전기동력학 기술을 이용한 시설재배지 토양 염류제거 실증 연구)

  • Lee, You-Jin;Choi, Jeong-Hee;Sim, Seong-Ju;Ha, Tae-Hyun;Lee, Hyun-Goo
    • Korean Chemical Engineering Research
    • /
    • v.52 no.1
    • /
    • pp.126-132
    • /
    • 2014
  • A pilot-scale electrokinetic (EK) separation field test ($2{\times}3{\times}0.2m^3$, $W{\times}L{\times}D$) was performed in a greenhouse to remove salts from saline soil. Initially, the greenhouse soil had high electrical conductivity (EC), about 9 dS/m, and contained mainly $Ca^{2+}$, $Cl^-$ and $SO_4^{2-}$ ions. After 2 weeks of EK treatment, the soil EC was reduced to 52% compared with its initial value. The EC reduction was mostly achieved within the first week (47%) due to removal of $Na^+$ and $Cl^-$ ions, but ions with a high adsorption capacity such as $Ca^{2+}$ and $SO_4^{2-}$ ions were difficult to be removed. During the EK test, the soil temperature increased and it reached around $50^{\circ}C$ at some regions. For in situ application to soils in cultivation, the current should be controlled to limit increases in temperature, especially near the cathodes. In conclusion, the in situ EK technique is feasible for the restoration of saline greenhouse soils in or no cultivation and an appropriate strategy is necessary for more effective remediation.

Effects of the Cooling and Heating System with Seasonal Thermal Storage in Alluvial Aquifer on Greenhouse Heating (충적대수층 계간축열 냉난방 시스템의 온실 난방 효과)

  • Moon, Jong Pil;Kang, Geum Choon;Kim, Hyung Gweon;Lee, Tae Seok;Oh, Sung Sik;Jin, Byung Ok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.6
    • /
    • pp.127-135
    • /
    • 2017
  • In this study, a cold well and a warm one with the distance of 100 m were installed in the alluvial aquifer. Groundwater used as the heat and the cold source of heat pump was designed to flow into the warm and the cold well with a diameter of 200 mm. In order to increase the heat and cold storage in aquifer, six auxiliary wells with the diameter of 50 mm and the depth of 30 m were installed at an interval of 5 m from the main well. Also, heat pump 50 RT, the thermal tank $40m^3$, and a remote control and monitoring system were installed in three single-span greenhouses ($2,100m^2$) for growing tomato in Buyeo, Chungcheongnam-do. According to the aquifer heat storage test which had been conducted from Aug. 31 to Sep. 22, 2016, warm water of $850m^3$ was found to flow into warm well. The temperature of the injected water was $30^{\circ}C$ (intake temperature : $15^{\circ}C$), and the heat of 12.8 Gcal was stored. The greenhouse heating test in winter had been conducted from Nov. 21, 2016 to Apr. 30, 2017. On Nov. 21, 2016 when heating greenhouse started, the aquifer temperature of the warm well was $18.5^{\circ}C$. The COP for heating with water source at $18.5^{\circ}C$ was 3.8. The intake water temperature of warm well was gradually lowered to the temperature of $15^{\circ}C$ on Jan. 2, 2017 and the heat pump COP was measured to be 3.2 at that time. As a result, the heat pump COP was improved by 18 %. and retrieval heat was 8 Gcal, the retrieval rate of heat stored in aquifer was estimated at 63 %.

Identification of Sweet Pepper Greenhouse by Analysis of Environmental Data in Greenhouse (온실 내 환경데이터 분석을 통한 파프리카 온실의 식별)

  • Kim, Na-eun;Lee, Kyoung-geun;Lee, Deog-hyun;Moon, Byeong-eun;Park, Jae-sung;Kim, Hyeon-tae
    • Journal of Bio-Environment Control
    • /
    • v.30 no.1
    • /
    • pp.19-26
    • /
    • 2021
  • In this study, analysis was performed to identify three greenhouses located in the same area using principal component analysis (PCA) and linear discrimination analysis (LDA). The environmental data in the greenhouse were from 3 farms in the same area, and the values collected at 1 hour intervals for a total of 4 weeks from April 1 to April 28 were used. Before analyzing the data, it was pre-processed to normalize the data, and the analysis was performed by dividing it into 80% of the training data and 20% of the test data. As a result of PCA and LDA analysis, it was found that PCA classification accuracy was 57.51% and LDA classification was 67.06%, indicating that it can be classified by greenhouse. Based on the farmhouse data classified in advance, the data of the new environment can be classified into specific groups to determine the tendency of the data. Such data is judged to be a way to increase the utilization of data by facilitating identification.

Analysis on the Displacement Constraints of Frames for Plastic Film Greenhouse (플라스틱 필름 온실용 구조재의 변위제한 검토)

  • Yun, Sung-Wook;Choi, Man-Kwon;Lee, Siyoung;Kang, Donghyeon;Kim, Hyeon-Tae;Yoon, Yong-Cheol
    • Journal of agriculture & life science
    • /
    • v.50 no.1
    • /
    • pp.273-281
    • /
    • 2016
  • In this study, after carrying out a bending test that targeted the frames of plastic film greenhouse, the load-displacement relationship was analyzed to be used as basic data to develop greenhouse construction and maintenance guidelines. As a result, regardless of the shapes of the specimen, the yield and the maximum load increased as the size of the specimen increased. The displacement also showed the same pattern. A steel pipe showed lower yield and maximum load than a square pipe, and the displacement was large. In the steel pipe case, the displacement under the yield and maximum load was in the range of approximately 1.42-4.20mm and 5.80-24.13mm, respectively. In the square pipe case, the displacement under the yield and maximum load was in the range of approximately 1.62-3.00mm and 3.13-8.01mm, respectively. Further, a large difference was observed between the result of this test and the values calculated by a conventionally provided standard. In particular, not much difference was found from the result of this test in the case of a purlin member from the values provided by previous researches. However, a large difference was observed in the column or main rafter members. Furthermore, when a wide-span and venlo type, which is a glasshouse, was used as a target(h/100 and h/80), the displacement under the yield and maximum load was approximately 28.0mm and 35.0mm, respectively, which showed a large difference compared with the Netherlands standard(14.0mm) of a glasshouse. Further, in the main rafter case, a large difference was observed in the displacement limit according to the width(i.e., span) of the greenhouse where members are used. Therefore, because the displacement limit can vary depending on various factors such as type, form, and size of a greenhouse, we determined that studies or tests that consider these factors should be carried out to reflect them in the construction and maintenance of greenhouses.

Evaluation of Resistance to the Aphid (Aphis glycines Matsumura) in Soybean Cultivars and Germplasms

  • Kim, Myung Sik;Sung, Mi Kyung;Baek, Woon Jang;Kim, Min Hwan;Chung, Jong Il
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.57 no.4
    • /
    • pp.365-372
    • /
    • 2012
  • Native of soybean aphid (Aphis glycines Matsumura) is an Asia and aphid is one of the dangerous pests in soybean [Glycine max (L.) Merr.]. High density aphid populations can reduce crop production by causing severe damage. The objective of this study was evaluation of resistance to the soybean aphid in soybean cultivars and germplasms. A total of fifty five soybean cultivars or germplasms, including two susceptible and two resistant check varieties, were infested to evaluate their resistance in the field cage and greenhouse test by aphid colonies which derived from wild collected one soybean aphid biotype in Korea. The average number of reproduced soybean aphid was evaluated with 62.7 aphids in the resistant check variety PI 567598B and also estimated with 1,807 aphids for susceptible check variety Williams 82. In soybean varieties and germplasms, the average reproduced soybean aphid populations ranged from the lowest 497 aphids for Junjeori to the highest 3,862 aphids for Mansu. About seventy six percent of soybean cultivars and germplasms were shown high density soybean aphid populations when compared with another susceptible check variety PI 567543C in the field cage test. From the greenhouse test to evaluate aphid index, 87.3% of soybean cultivars or germplasms presented aphid index with 9.0. No soybean cultivars and germplasms were observed with soybean resistant phenotype when regarded a aphid resistant level as less than 10% aphid reproductions compared with susceptible check Williams 82. Although no Korean soybean cultivars were identified with resistant trait to the soybean aphid, we found one great resistant genetic resource PI 567598B in this study. This result will be helpful to further study for providing useful genetic information for soybean researchers.

Analysis on Heat Loss of Single-span Greenhouse Using Small-scaled Wind Tunnel (소형풍동을 이용한 단동 비닐온실의 열손실 분석)

  • Kim, Young Hwa;Kim, Hyung kow;Lee, Tae suk;Oh, Sung sik;Ryou, Young sun
    • Journal of Bio-Environment Control
    • /
    • v.29 no.1
    • /
    • pp.73-79
    • /
    • 2020
  • The objective of this study is to analyze the heat transfer loss of covering materials in a single-span plastic greenhouse under the steady-state wind environment. To achieve this objective, the following were conducted: (1) design of a small-scaled wind tunnel (SCWT) to analyze heat losses of the greenhouse and its performance; (2) determination of the overall heat transfer coefficient (OHTC) for the covering materials using a small-scaled greenhouse model. The SCWT consists of the blowing, dispersion, steady flow, reduction and testing areas. Each part of the SCWT was customized and designed to maintain air flow at steady state and to minimize the variances in the SCWT test. In this study, the OHTCs of the covering materials were calculated by separating each with the roof, side wall, front and back of the small-scaled greenhouse model. The results of this study show that the OHTC of the roof increases as wind speed increases but the zones in which the increase rate of the OHTC decreased, were distinguished by wind tunnel wing speed of 2 ms-1. For the side wall, the increase rate of the OHTC was particularly higher in the 0-1 ms-1 zone.

Analysis on the Effect of Greenhouse Humidity Control by Counter-flow Ventilator in Winter (동절기 대향류형 환기장치의 온실 내 습도 조절 효과 분석)

  • Lee, Taeseok;Kang, Geumchoon;Jang, Jaekyung;Paek, Yee;Lim, Ryugap
    • Journal of Bio-Environment Control
    • /
    • v.29 no.3
    • /
    • pp.259-264
    • /
    • 2020
  • In this study, the humidity control effect of a counter-flow ventilator was analyzed in a greenhouse with high relative humidity at night in the winter season. A case of the counter-flow ventilator was 0.96 × 0.65× 0.82(W × D × H, m) and there were heat transfer element and two fans for air supply and exhaust in the counter-flow ventilator. Two counter-flow ventilators were used in this study and the setting humidity of the ventilators was 80%. The temperature and relative humidity at night(18:00-8:00) in the greenhouse were measured. In a greenhouse without a counter-flow ventilator, the average temperature and humidity was 14.9℃, 82.8%, respectively. When the counter-flow ventilator was operated, the corresponding averages were 15.1℃, 79.9%. The independent sample t test of monthly temperature and relative humidity showed no difference in temperature, and a significant difference in relative humidity with 1% of the significance level. Therefore, using the counter-flow ventilator helps to control relative humidity in greenhouse and increase yield.. And further research considering the pros and cons of using the counter-flow ventilator is needed.

Effect of the Pipe Joint on Structural Performance of a Single-span Greenhouse: A Full-scale Experimental and Numerical Study (파이프 이음부가 단동온실 구조성능에 미치는 영향: 실대형 실험적 및 해석적 연구)

  • Shin, Hyun Ho;Ryu, Hee Ryong;Yu, In Ho;Cho, Myeong Whan;Seo, Tae Cheol;Kim, Seung Yu;Choi, Man Kwon
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.410-418
    • /
    • 2021
  • This study was conducted in 8.2m wide single-span greenhouse to investigate the effect of presence or absence of rafter steel pipe joint and foundation conditions on greenhouse structural performance. Structural performance was evaluated by static loading test using the structural performance evaluation system for single-span greenhouse. The measured displacement was compared with the predicted result by numerical analysis. The displacement of each measurement location showed a significant difference regardless of the conditions of the foundation and presence or absence of rafter steel pipe joint. Compared to the hinge conditions, the difference in structural performance of the greenhouse in the fixed conditions was seen to be relatively large. The difference in structural performance according to presence or absence of rafter steel pipe joints, the lateral stiffness of the joint was 8.1% greater.

Comparison of insecticide susceptibility and enzyme activities of biotype B and Q of Bemisia tabaci (담배가루이 Biotype B와 Q의 약제감수성과 효소활성 비교)

  • Kim, Eun-Hee;Sung, Jae-Wook;Yang, Jeong-Oh;Ahn, Hee-Geun;Yoon, Chang-Mann;Seo, Mi-Ja;Kim, Gil-Hah
    • The Korean Journal of Pesticide Science
    • /
    • v.11 no.4
    • /
    • pp.320-330
    • /
    • 2007
  • Mitochondrial 16S DNA sequences of Bemisia tabaci which were collected on rose greenhouse of Iwol and Jinchen in Chungbuk and red pepper field of Miryang, Gyeongnam, were analyzed. The mtCOI PCR product of B. tabaci collected on red pepper field of Miryang were digested with EcoT14I (Sty I) into two fragments 555bp and 311bp, while the PCR product of B. tabaci collected on rose greenhouse of Iwol were digested with Sty I into two fragments of 560bp and 306bp. As a result, B. tabaci collected on red pepper reveal biotype Q and those on rose greenhouse was biotype B. These was difference between two biotypes in insecticide susceptibility, and the biotype B was more susceptible than biotype Q. As a result of foliar systemic test, root-uptake systemic test and residual effect, the biotype B was more susceptible. In case of inhibition effect on enzyme activities of fenitrothion (organophosphorous) and fenothiocarb (carbamate), those of biotype Q was higher than those of biotype B. These results indicate that biotype Q was more resistant than biotype B against 12 insecticides.