Abstract
A long-span (more than 8m) plastic greenhouse is currently being used in farms due to its magnified benefits, such as the convenience of the farming equipment used, and the land usage efficiency. In this study, the reinforcing effects of the use of a pretension tie were shown. In a previous study, tests for a 6.5m single-span-type greenhouse announced by Rural Development Administration were carried out. The tests of symmetric and eccentrics now loading by the sun and wind were conducted for the 10.2m span with a ${\phi}48.1{\times}2.1$ section in this study, after which the load-deflection relationship was compared for the cases of reinforcement with a tie and without a tie. The results of the symmetric snow loading test showed that the strength increased by 68~93% in the case of the specimen with a tied arch. The failure mode of the specimen without a tie tended to be that with a sway failure mechanism, and that of the reinforcement specimens with a tie tended to be that with an arch buckling mechanism. The results of the eccentric snow loading test showed that the strength of the specimen with a tie increased by 10~20% compared to that of the specimen without a tie. For the failure mode of the latter, a combined failure mechanism was adapted, although the failure mode of the tied specimens tended to be that with an arch buckling mechanism.
폭이 8m이상인 광폭형 비닐하우스는 농기구 사용의 편리성과 토지 활용성 등의 장점이 부각되면서 농가에 점차 보급되고 있는 실정이다. 이 논문은 광폭형 비닐하우스의 인장타이보강에 따른 효과에 관한 실험결과를 제공한다. 이미 앞선 연구에서는 농촌진흥청에서 고시된 폭이 6.5m인 단동형 비닐하우스 모델을 선정하여 인장타이보강효과에 대한 실험을 수행한바 있다. 본 연구에서는 ${\phi}48.1{\times}2.1$ 단면, 폭이 10.2m인 광폭형 비닐하우스를 선정하여 대칭하중 가력실험과, 햇빛에 의한 열이나 바람에 의한 불균형 적설하중을 산정한 편심하중 가력실험을 수행하였다. 타이를 보강하지 않은 실험체와 인장타이를 보강한 실험체의 하중-변위 관계를 비교 분석하였다. 대칭하중 가력실험에서 인장타이로 보강되어진 모델은 내력이 68~93%정도 증가하였다. 파괴모드는 무보강시에는 sway붕괴 메카니즘이 일어났으나 타이 보강시에는 아치 좌굴 메카니즘이 일어났다. 편심하중 가력실험 결과 타이로 보강하였을 경우 내력이 10~20%정도 증가하였다. 파괴모드는 무보강시에는 조합 붕괴 메카니즘이 일어났지만 타이보강시에는 아치 좌굴 메카니즘이 일어났다.