• Title/Summary/Keyword: green-wall

Search Result 307, Processing Time 0.025 seconds

Comparison of the Characteristics of Green Screen and LED Wall in Virtual Production System

  • Shan, Xinyi;Chung, Jeanhun
    • International journal of advanced smart convergence
    • /
    • v.11 no.2
    • /
    • pp.64-70
    • /
    • 2022
  • In recent years, with the continuous innovation and upgrading of engine software, the real-time rendering technology in film and television has been continuously improved, and the virtual production technology has also developed rapidly. This paper introduces the green screen often used in traditional film production and a virtual production technology based on light-emitting-diode background wall that was proposed and implemented last year. We analyzed the two production methods of virtual production and compared their characteristics. Based on these results, we can better understand the differences and respective advantages of the two production methods. And we also can according to the production budget, production cycle and the creative and technical capabilities of the team make better choices during the production process. We believe virtual production technology will be production in the future to provide a more solid technical guarantee for the development of the film industry, and this work will pave the way for further research on virtual production technology.

Growth Response on the Euonymus fortunei 'Emelad' n 'Gold' as affected by Artificial Plantings Soil Properties during Dry Spring Season (봄철 건조기 용기형 벽면녹화에서 식재지반 조성에 따른 황금줄사철의 적응성)

  • Ju, Jin-Hee;Kim, Hea-Ran;Park, Heon;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.23 no.7
    • /
    • pp.1299-1305
    • /
    • 2014
  • For evaluating the effect of various artificial planting soil properties on the Euonymus fortunei 'Emelad'n Gold' growth, a container green wall system experiment was conducted in a wall of greenhouse at Konkuk University, Glocal campus. The experimental artificial planting grounds were prepared with different organic soil conditioner ratios (Control, $A_4O_1$, $A_2O_1$ and $A_1O_1$) and with drought tolerance and an ornamental value Euonymus fortunei 'Emelad'n Gold' was planted. The soil and plant characteristics were investigated from April to Jun 2010. The volumetric soil moisture contents were significantly increasing order as the amount of organic soil conditioner level increased in order to $A_1O_1$ > $A_2O_1$ > $A_4O_1$ > Control. At 4 treatment, soil chemical properties were inversely related to organic soil container ratios increase. The differences of root collar caliper, number of branch, and survival rate between the organic soil conditioner ratio were not significantly affected by organic soil conditioner. But, plant height, internode length, leaf length and leaf width were significantly shorter on plants planted $A_1O_1$ than plants planted other treatments. Therefore, Euonymus fortunei 'Emelad'n Gold' had good growth response regardless of organic soil conditioner ratio and the plant is expected to be a highly valuable shrub for the green wall system if it should be considered in integration with stormwater retention or as a soil conditioner for increasing soil water contents in artificial planting soil.

An Analysis of the Repetition Pattern in Green facade focusing on the Biophilic Design (벽면녹화의 패턴 표현방법에 따른 반복패턴 디자인 특성 분석)

  • Jung, HeeYoung;Lee, Hyunsoo
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.1
    • /
    • pp.81-92
    • /
    • 2016
  • Within green facades, the greening side of the wall is first recognized by people, leaving a visually lasting impression. As facades play a crucial factor in forming street image, their design can be considered most important. In modern days, 'patterns,' one of the popular elements of design, has developed into becoming a method of expressing architects' emotions or images as well as ways of seeking satisfaction. As opposed to recent overseas movement where patterned green facades have been widely utilized, the domestic trend still remains in outdoor green facades without patterns. This study, focusing on overseas patterned green facades, classifies the facade pattern's expressive methods into two greater parts, and four categories. Furthermore, among the elements and properties from Biophilic pattern guidelines, we specifically focus on 'Repetition Pattern,' which corresponds to 'Complexity & Order.' Biophilic design has the notion of pursuing an environment that aids modern people's comfort and well being. Providing information on patterned green facades that have largely gained popularity, this study also presents its aesthetic directions that may be applicable domestically in the future.

Experimental Study on Hydrodynamic Characteristics of Dam Break Flow for Estimation of Green Water Loading (청수현상 추정을 위한 댐 붕괴 흐름의 유체동역학적 특성에 관한 실험적 연구)

  • Hyung Joon Kim;Jong Mu Kim;Jae Hong Kim;Kwang Hyo Jung;Gang Nam Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.2
    • /
    • pp.120-134
    • /
    • 2023
  • In this study, hydrodynamic characteristics of dam break flow were investigated by a series of experiments. The experiments were performed in a 2-D rectangular flume with obtaining instantaneous images of dam break flow to capture the free surface elevation, and pressure distributions on vertical wall and bottom of the flume. The initial water depth of the dam break flow was changed into 3 different heights, and the gate opening speed was changed during the experiments to study the effect of the gate speed in the dam break flow. Generation of dam break phenomena could be classified into three stages, i.e., very initial, relatively stable, and wall impact stages. The wall impact stage could be separated into 4 generation phases of wall impinge, run-up, overturning, and touchdown phases based on the deformation of the free surface. The free surface elevation were investigated with various initial water depth and compared with the analytic solutions by Ritter (1892). The pressures acting on the vertical wall and bottom were provided for the whole period of dam break flow varying the initial water depth and gate open speed. The measurement results of the dam break flow was compared with the hydrodynamic characteristics of green water phenomena, and it showed that the dam break flow could overestimate the green water loading based on the estimation suggested by Buchner (2002).

The analysis study of mural painting pigments at Pongjongsa Kuknakjon (봉정사 극락전 벽화 안료의 재질 분석 연구(II))

  • Cho, Nam-Chu;Hong, Jong-Ouk;Moon, Whan-Suk;Hwang, Jin-Ju
    • 보존과학연구
    • /
    • s.21
    • /
    • pp.119-143
    • /
    • 2000
  • The pigments composition and structure of the mural painting at Pongjongsa Kuknakjon is discussed. The structure of inner wall is consisited of Paint layer, Ground divided two layers of yellow and white pigments, Support. In case of outer wall, it is consisted of Paint layer, Ground divided three layers of yellow and green pigments, a layer mixed green pigments and paint layer, Support. As a result of compositon analysis of mural painting pigments at Pongjongsa Kuknakjon using Micro-area X-ray diffraction system, the red pigment on inner wall is consisted of Heamatite($Fe_2O_3$), Magnetite($Fe_3O_4$)of deep black pigment, and Chalcocite($Cu_2S$) of light black pigment. The white pigment on outer wall is consisted of Anglesite($PbSO_4$) and Atacamite($Cu_2CI(OH)_3$) of green pigment. We found out that natural pigments painted in the mural painting at Pongjongsa Kuknakjon has kept up its own color for a long time due to using the natural pigment not to artificial synthetic pigment.

  • PDF

Changes of the Cell Wall Structures during Maturation of Jujube Fruits (성숙 중 대추의 세포벽 조직 변화)

  • 신승렬;손미애;김주남;김광수
    • Food Science and Preservation
    • /
    • v.5 no.4
    • /
    • pp.342-345
    • /
    • 1998
  • This study was investigated to the structure of cell wall during maturation for the research of softening of jujube fruits. Cell was hardly combined with each other untill turning stage, but middle lamella of cell wall was splited at mature stage and was observed splited cell. The middle lamella of cell wall was not observed at green mature stage, but was observed at turning stage. Cell wall was degraded at mature stage. It was observed mitochondria, endoplasmic reticulum et. at in jujube fruit of green mature stage, but cytoplasm and organelle was attached on cell wall as vacuole was grown up after turning stage.

  • PDF

Influence of Air-tightness on Heat Energy Performance in Post and Beam Building with Exposed Wood Frame

  • Kim, Hyun-Bae;Kim, Se-Jong;Oh, Jung-Kwon;Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.40 no.5
    • /
    • pp.319-326
    • /
    • 2012
  • Han-green building is one of the modernized Korean traditional buildings developed by Korea Forest Research Institute. This building was developed to increase the competitiveness of Korean traditional building using state-of-art technologies; hence Han-green building has the inherent characteristics of traditional building such as exposed wood frame in wall. Because of discontinuity in wall by the exposed wood frame, there is a concern on heat-air leaking in terms of energy performance. In this study, air-tightness of Han-green building was evaluated to investigate the influence of gaps between frames and in-fill walls. Blower door test was carried out to evaluate the air-tightness, and air-change rate (ACH50) was evaluated by averaging four set of pressurization and depressurization test. The air-change rate of Han-green house was 5.91 $h^{-1}$. To improve energy performance of Han-green house, thermal infrared images of Han-green house were taken in winter with heating to find out where the heat loss occurred. It was found that the building lost more heat through gaps between frames and in-fill walls rather than through other parts of this building. After covering all the gaps by taping, the blower door test was performed again, and the air-change rate was improved to 5.25 $h^{-1}$. From this analysis, it was concluded that the heated air can leak through the gaps between frames and walls. Therefore, when one designs the post and beam building with exposed frame, the detail design between frame and wall needs to be carefully dealt. However, Han-green building showed relatively high air-tightness comparing with other country research results.

Analysis of Building Energy Reduction Effect based on the Green Wall Planting Foundation Type Using a Simulation Program (건물일체형 패널형 벽면녹화 식재기반 유형별 건물에너지 성능 분석)

  • Kim, Jeong-Ho;Kwon, Ki-Uk;Yoon, Yong-Han
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.6
    • /
    • pp.936-946
    • /
    • 2015
  • This study is aimed to analyze the reduction performance of building energy consumption according to planting base types of panel-type green walls which can be applied to existing buildings. The performance was compared to the general performance of green walls that have demonstrated effects of improving the thermal environment and reducing building energy consumption in urban areas. The number of planting base types was 4 in total, and simulations were conducted to analyze the thermal conductivity, thermal transmittance, and overall building energy consumption rate of each planting base type. The highest thermal conductivity by the planting base type was Case C (0.053W/mK), followed by Case B (0.1W/mK) and Case D (0.17W/mK). According to the results of energy simulation, the most significant reduction of cooling peak load per unit area was Case C (1.19%), followed by Case B (1.14%) and Case D (1.01%) when compared to Case A to which green wall was not applied; and the most significant reduction of heating peak load per unit area was estimated to be Case C (2.38%), followed by Case B (1.82%) and case D (1.50%) when compared to Case A. The amount of yearly cooling and heating energy use per unit area showed 3.04~3.22% of reduction rate. The amount of the 1st energy use showed 5,844 kWh/yr of decrease on average for other types when compared to Case A. The amount of yearly $CO_2$ emission showed 996kg of decrease on average when compared to Case A to which the green wall was not applied. According to the results of energy performance evaluation by planting location, the most efficient energy performance was eastward followed by westward, southward and northward. According to the results of energy performance evaluation by planting location by green wall ratio, it was found that as the ratio of green wall increased, the energy performance displayed better results, showing approx. double reduction rate in energy consumption at 100% of green wall ratio than the reduction rate at 20% to 80% of green wall ratio.

A Study on The Color Examination and Color Planning in the Different Type of Classroom (학교 교실의 용도별 색채분포 및 색채계획에 관한 연구)

  • 김은정;김기환
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2003.05a
    • /
    • pp.65-68
    • /
    • 2003
  • The purpose of this study is examine the color planning in the different type of classroom to establish interior color planning. This study also uses environmental planning and practical use of basic data for color planning to future school facilities. The summary of this study is as followed. The primary school and middle school classrooms as well as the open space classrooms floor color recommended of brown and the primary school wall color is light yellow, middle school wall color is light yellow and brown. The high school classroom color is recommended brown and wall color to light yellow and green system. The recommended floor color of primary school which includes in computer room and language study room, library of the multi-purpose of media room recommended are gray, brown and pink. The recommended wall color in primary school is light gray. The middle school floor color propose gray and light brown and wall recommended color is light brown, gray, ivory with the high school the computer room, language study room and library. The floor color is recommended gray, green and the wall propose blue. Moreover, recognize that importance of color effectiveness in school interior facilities considering with Interior covering material in class room.

  • PDF

Shear Performance of Hybrid Post and Beam Wall System Infilled with Structural Insulation Panel (SIP)

  • Shim, Kug-Bo;Hwang, Kweon-Hwan;Park, Joo-Saeng;Park, Moon-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.5
    • /
    • pp.405-413
    • /
    • 2010
  • A hybrid post and beam shear wall system with structural insulation panel (SIP) infill was developed as a part of a green home 'Han-green' project through post and beam construction for contemporary life style. This project is on-going at the Korea Forest Research Institute to develop a new building system which improves Korean traditional wet-type building system and stimulates industrialized wood construction practice with pre-cut system. Compared to the traditional wet-type infill wall components, the hybrid wall system has benefits, such as, higher structural capacity, better thermal insulation performance, and shorter construction term due to the dry-type construction. To build up the hybrid wall system, in previous, SIP infill wall components can be manufactured at factory, and then inserted and nailed with helically threaded nails into the post and beam members at site. Shear performance of the hybrid wall system was evaluated through horizontal shear tests. The SIP hybrid wall system showed higher maximum shear strength, initial stiffness, ductility, yield strength, specified strength, and the specified allowable strength than those of post and beam with light-frame wall system. In addition to this, the hybrid wall system can provide speedy construction and structural and functional advantages including energy efficiency in the building system.