• Title/Summary/Keyword: green energy

Search Result 2,722, Processing Time 0.04 seconds

Study on the palstic green houses depending on regional weather conditions (지역기후특성을 고려한 비닐온실에 관한연구)

  • Woo, Byung Kwan;Lee, Sung;Kim, Se Hwan;Kim, Sam Yeol
    • KIEAE Journal
    • /
    • v.9 no.5
    • /
    • pp.39-46
    • /
    • 2009
  • Most Plastic Green Houses in Korea are made according the European weather condition, which lead to have very low solar energy efficiency. Moreover, the function of green houses, as well as the structure of them, has not changed for Korean weather condition. Therefore, the structure and function of them should adopt the regional weather condition in order to improve the energy efficiency. This paper investigates the current plastic green housesin Korea, and presents an alternative for improving the energy efficiency. The elements of green houses were investigated. When using a partial opaque insulation with a thermal storage body, the difference of indoor air temperature became 20C during daytime, and 5C during night, which will save massive fossil fuels.

A Study on the Estimation of Green Remodeling Energy Reduction Tool in Building Construction - Office Building - (그린리모델링 에너지저감 효과 예측 Tool 구축에 관한 기초연구 - 업무시설 대상 -)

  • Ju, Jung-Hoon;Lee, Keon-Ho;Koo, Bo-Koung;Kim, Ki-Tae
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.8
    • /
    • pp.13-18
    • /
    • 2018
  • The purpose of this study was to study on the estimation of green remodeling energy reduction tool in building construction. Green Remodeling Decision System that can predict the energy reduction effect in green remodeling is developed as a tool for simple remodeling of green remodeling considering users' convenience, so that it can quickly and comprehensively determine power peak load reduction factor technology. A preliminary simulation result of a short preliminary remodeling evaluation is DB. It will be developed as a tool that can be easily accessed by users such as web and apps.

Performance of the Electrode for All-vanadium Redox Flow Battery (바나듐 레독스 흐름 전지용 전극의 성능 평가)

  • IN, DAE-MIN;SONG, YOUNG-JOON;LEE, DAE-YEOP;RYU, CHEOL-HWI;HWANG, GAB-JIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.2
    • /
    • pp.200-205
    • /
    • 2017
  • The three electrodes (carbon felt) were tested in all-vanadium redox flow battery (VRFB) to confirm the its usefulness. The electrode property was measured by the CV (cyclic voltammetry) method. The current ratio of maximum peak(IPA/IPC) in GF040BH5 and GF051BH3 had almost the same value compared to that in XF30A. The performances of VRFB using the each electrode were measured during 5 cycles of charge-discharge at the current density of $60mA/cm^2$. An average energy efficiency of the VRFB was 77.8%, 77.3%, and 79.2% for XF30A, GF040BH5 and GF051BH3, respectively. It was confirmed from the data that GF040BH5 and GF051BH3 is well suited for use in a VRFB as a electrode, like XF30A.

The Analysis of Green Roof during the Summer by Numerical Method (모델을 이용한 하절기 옥상정원 해석)

  • Byun, Kihong
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.5
    • /
    • pp.51-62
    • /
    • 2016
  • The purpose of this paper is to study the effectiveness of a green roof by simple mathematical model. The developed model simulates a green roof during the summer. The results explain and support the claims in the literature such that effectiveness of a green roof depends on the climate condition, and on the insulation condition of the roof. If insolation can not be reduced more than 60% by the shading effects of a green roof, more active measures than green roof seem necessary. The analysis tools like presented in the paper is necessary especially to consider climate effect, to design, and also to test green roof.

Analysis of the Passive Design Application Status for the Improvement of G-SEED (G-SEED 개선을 위한 패시브디자인 적용현황 분석)

  • Kim, Hye-Won;Tae, Choon-Seob;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.6
    • /
    • pp.35-42
    • /
    • 2015
  • The proper use of the passive and active design elements are important for the realization of green buildings. The G-SEED (Green Standard for Energy and Environmental Design) has been implemented in Korea to promote green building construction reflecting these design elements. In this paper, evaluation items of G-SEED which related to the passive design were selected. And improvement direction for the G-SEED was proposed through the analysis of the application status of the passive design elements for the G-SEED certified buildings. This results can be used for developing study on the future improvement of the assessment criteria of G-SEED.

The Analysis on the Evaluation Items of Korea Green Building Certification Criteria by the Case Studies of Collective Housing (국내 공동주택 부문의 친환경건축 인증 평가 항목 및 사례 분석)

  • Kim, Chang-Sung
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.93-100
    • /
    • 2013
  • Many countries have made their best to protect the earth from global warming and to find solutions for the reduction of carbon dioxide emittion and energy consumption. Especially, buildings have emitted over 40% of carbon dioxide against whole quantities emitted to the earth. Therefore, the reduction of carbon dioxide emitted from buildings require to save the earth environment. Energy consumption of buildings in Korea has reached 24% of total energy quantities, and energy consumption of collective housing has been continuously increasing. So, Korea government has also executed the Green Building Certification Criteria(GBCC). The GBCC evaluates the 8 types of buildings - collective housing, office, school, etc - to certificate the green building. In this paper, the evaluation items of collective housing in GBCC were reviewed to be used as the reference data for future revisions by the case studies. According to the results of this study, current version of GBCC requires additional revisions about the evaluations of energy consumption monitoring, commissioning and existing building.

Green Energy Harvester using a Piezoelectric Regenerated Paper (압전종이를 이용한 그린에너지 하베스터)

  • Koh, Hyun-Woo;Kwon, Yeon-Ho;Yun, Gyu-Young;Kim, Joo-Hyung;Kim, Jae-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.198-201
    • /
    • 2009
  • Due to piezoelectric property of regenerated cellulose paper, a green energy harvester using an electro-active paper (EAPap) was studied. In order to design the green energy harvester, we simulated cymbal type energy harvesting structures for single and multi-stacked layers of EAPap films. From the simulation, the optimized material orientation, thickness of harvesting structure was selected. By measuring of the induced output voltage by applying stress on energy harvester will be explained in detail. Therefore we propose the feasibility of the nature-friendly piezoelectric EAPap as a new green energy harvesting material.

  • PDF

A Case Study on the Design Variables Evaluation of Green Roof System effecting on Building Energy Conservation (건물 에너지 소비량에 영향을 미치는 옥상녹화시스템 설계변수 평가에 관한 사례 연구)

  • Choi, Jeong-Min
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.3
    • /
    • pp.41-48
    • /
    • 2015
  • This study is to find out the major design variables of Green roof system effecting on the building energy consumption. Therefore, in three categories of green roof system, namely, foliage layer, soil layer and irrigation, 10 design variables are selected and simulated with one-story case building. Simulation is carried out with Design Builder and EnergyPlus. Finally, it was found out the effects of major variables affecting on the building heating and cooling energy and how they are affecting on the heating and cooling seasons respectively.

Synthesis and Characteristics of Type-II ZnO/ZnSe Core/Shell Heterostructures for High Efficient Photocatalytic Activity (Type-II ZnO/ZnSe 코어/쉘 이종 구조 합성 및 광촉매활성 평가)

  • Lee, Woo-Hyoung;Choi, Kwang-Il;Kang, Dong-Cheon;Beak, Su-Woong;Lee, Suk-Ho;Lim, Cheol-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.3
    • /
    • pp.178-183
    • /
    • 2014
  • Recently, various type of nanomaterials such as nanorod, nanowire, nanotube and their core/shell nanostructures have attracted much attention in photocatalyst due to their unique properties. Among them, Type-II core/shell heterostructures have extensively studied because it has exhibited improved electrical and optical properties against their single-component nanostructure. Such structures are expected to offer high absorption efficiency and fast charge transport due to their stepwised energetic combination and large internal surface area. Thus, it has been considered as potential candidates for high efficient photocatalytic activity. In this work, we introduce a novel chemical conversion process to synthesize Type-II ZnO/ZnSe core/shell heterostructures. A plausible conversion mechanism to ZnO/ZnSe core/shell heterostructres was proposed based on SEM, XRD, TEM and XPS analysis. The ZnO/ZnSe heterostructures exhibited excellent photocatalytic activity toward the decomposition of RhB dye compared to the ZnO nanorod arrays due to enhanced light absorption and the type-II cascade band structure.

A Study on the Development of Energy Simulation Program for Non-specialist to Enhance Green Remodeling (그린리모델링 활성화를 위한 비전문가용 에너지 소비량 산정 프로그램 개발연구)

  • Bang, Sun-Kyu;Yoo, Jung-Hyun;Kim, Du-Hwan
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.11
    • /
    • pp.55-62
    • /
    • 2018
  • To receive financial support for the Green Remodeling, applicants must submit an energy simulation report. However, many of the applicants are not green remodeling specialist and energy simulation services are too expensive for them. For this reason, this study was to develop an energy simulation program to enhance green remodeling for the non-specialist such as housewives. Firstly, to enhance understanding and accessibility improvement energy simulation, simulation process was designed four steps and reducing input data. Specifically, input data was reduced by categorizing the following for the area, plan type, hot water load, electricity load, statistical inference. And then, to accurately verify the calculation result, the heat and hot water demand were derived and compared with ECO2 and Energy # program. Lastly, the calculation shows that there is a difference of 4% for the heat load and 15% to 33% for the hot water load respectively.