• Title/Summary/Keyword: gray correlation

Search Result 164, Processing Time 0.028 seconds

Binarization Based on the Spatial Correlation of Gray Levles (그레이 레벨의 공간적 상관관계 기반 이진화)

  • Seo, Suk-T.;Son, Seo-H.;Lee, In-K.;Jeong, Hye-C.;Kwon, Soon-H.
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.4
    • /
    • pp.466-471
    • /
    • 2007
  • Conventional thresholding methods including Otsu's thresholding method are based on the gray levels frequency histogram. But the gray levels frequency histogram is obtained by recomposing only frequency information from an input image, where frequency histogram dose not contain any other informations such as the distribution of gray levels and relation between gray levels. Therefore the methods using the gray levels frequency histogram occasionally present inappropriate threshold values because it cannot reflect informations of the given image sufficiently. In this paper, we define a correlation function of gray levels and propose a novel thresholding method using the gray levels frequency histogram and the spatial correlation information. The effectiveness of the proposed method will be shown through comparison with Otsu's thresholding method.

Development of an edge-based point correlation algorithm for fast and stable visual inspection system (고속 검사자동화를 위한 에지기반 점 상관 알고리즘의 개발)

  • 강동중;노태정
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.8
    • /
    • pp.640-646
    • /
    • 2003
  • We presents an edge-based point correlation algorithm for fast and stable visual inspection system. Conventional algorithms based on NGC(normalized gray-level correlation) have to overcome some difficulties in applying automated inspection systems to real factory environment. First of all, NGC algorithms involve highly complex computation and thus require high performance hardware for realtime process. In addition, lighting condition in realistic factory environments is not stable and therefore intensity variation from uncontrolled lights gives many troubles for applying NGC directly as pattern matching algorithm. We propose an algorithm to solve these problems, using thinned and binarized edge data, which are obtained from the original image. A point correlation algorithm with the thinned edges is introduced with image pyramid technique to reduce the computational complexity. Matching edges instead of using original gray-level image pixels overcomes problems in NGC method and pyramid of edges also provides fast and stable processing. All proposed methods are proved by the experiments using real images.

Construction Method of Binary Low Correlation Zone Sequence Set Using Gray Mapping (Gray 사상을 이용한 이진 낮은 상관구역 수열군의 생성법)

  • Jang, Ji-Woong;Kim, Young-Sik;Lim, Dae-Woon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.2C
    • /
    • pp.169-174
    • /
    • 2009
  • In this paper, we propose a new construction method of binary low correlation zone (LCZ) sequence set. New construction method applies Gray mapping to conventional quaternary LCZ sequence set that has specific property. The period of new binary sequence set is twice as that of used sequence set in construction, and maximum magnitude of correlation value within the LCZ and cardinality of new set is also twice as those of used quaternary sequence set. But the LCZ size is the same with that of used sequence set. If the used Quaternary sequence set is optimal, the constructed binary sequence set is optimal with high probability.

CORRELATION ASSESSMENT BETWEEN RESONANCE FREQUENCY ANALYSIS AND RADIOGRAPHIC METHOD ACCORDING TO PERI-IMPLANT BONE CHANGE

  • Lee Mi-Ran;Cho Lee-Ra;Yi Yang-Jin;Choi Hang-Moon;Park Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.6
    • /
    • pp.736-744
    • /
    • 2005
  • Statement of problem. Initial stability of implant is an important factor for predicting osseointegration. It requires a rapid, non-invasive, user-friendly technique to frequently assess the implant stability and the degree of osseointegration. Purpose. The aim of this study was to evaluate the correlation between the resonance frequency analysis (RFA) and the radiographic method for peri-implant bone change under in vitro conditions. Material and Method. Twenty implants of 3.75 mm in diameter(Neoplant, Neobiotech, Korea) were used. To simulate peri-implant bone change, 2 mm-deep $45^{\circ}$ range horizontal defect and 2 mm-deep $90^{\circ}$ range horizontal defect area were serially prepared perpendicular to the X-ray beam after conventional implant insertion. Customized film holding device was fabricated to standardize the projection geometry for serial radiographs of implants and direct digital image was obtained. ISQ values and gray values inside threads were measured before and after peri-implant bone defect preparation. Results. Within a limitation of this study, ISQ value of resonance frequency analysis was changed according to peri-implant bone change (p<0.05) and gray value of radiographic method was changed according to peri-implant bone change (p<0.05). There was no correlation between the ISQ value and the gray value for peri-implant bone change (p>0.05). But, in horizontal defect condition, relatively positive correlation were between ISQ and gray values(r=0.663). Conclusion. This results provided a possibility that peri-implant bone change may be evaluated by both RFA and radiographic method.

The Study of Standard Deviation of Gray Scale Histogram in Digital Subtraction Radiography as a Test Parameter for SuperimpoSition Error (중첩 불일치 평가기준으로서의 계수공제영상의 계조도 표준편차 연구)

  • Cho Bong-Hae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.417-422
    • /
    • 1999
  • Purpose : The aim of this study was to assess the validity of standard deviation of gray scale histogram in digital subtraction radiography as a test parameter for superimposition error. Materials and Methods : Twenty periapical radiographs were used as baseline images and they were copied to exclude the influence of exposure geomety and contrast differences. These subsequent images were linearly displaced by 0.1-0.5 mm in the x-. y- and xy-directions, rotated by 0.5-3° and distorted by angular contraction of 1-5° in x- and y-axis before subtraction. The standard deviations of gray levels in the subtraction images were obtained and paired t-tests were performed. Pearson correlation coefficients(r) were calculated between the standard deviations and the superimposition errors. Results : Linear displacement showed high correlation coefficients of 0.997, 0.997 and 0.995 in x-. y- and xy-axis respectively. Statistically significant different standard deviation existed among all linearly displaced groups(p<0.05). Distortion showed relatively low correlation coefficients of 0.982 and 0.959 in x- and y-axis. The standard deviations between the two distortion groups were statistically significant different(p<0.05). Conclusion : Standard deviation of gray level distribution in digital subtraction images is satisfactory but not perfect similarity measure to assess the superimposition errors.

  • PDF

Damage characterization in fiber reinforced polymer via Digital Volume Correlation

  • Vrgoc, Ana;Tomicevic, Zvonimir;Smaniotto, Benjamin;Hild, Francois
    • Coupled systems mechanics
    • /
    • v.10 no.6
    • /
    • pp.545-560
    • /
    • 2021
  • An in situ experiment imaged via X-ray computed tomography was performed on a continuous glass fiber mat reinforced epoxy resin composite. The investigated dogbone specimen was subjected to uniaxial cyclic tension. The reconstructed scans (i.e., gray level volumes) were registered via Digital Volume Correlation. The calculated maximum principal strain fields and correlation residual maps exhibited strain localization areas within the material bulk, thus indicating damage inception and growth toward the specimen surface. Strained bands and areas of elevated correlation residuals were mainly concentrated in the narrowest gauge section of the investigated specimen, as well as on the specimen ligament edges. Gray level residuals were laid over the corresponding mesostructure to highlight and characterize damage development within the material bulk.

The Study of Visual Fatigue by Monitor Letter Contrast with an Eye Tracker (아이트래커를 이용한 모니터 글자 대비도에 따른 눈의 피로도 연구)

  • Kim, Ha-Rim;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.533-538
    • /
    • 2014
  • Purpose: This study is to investigate correlation between eye fatigue and letter contrast according to letter contrast changes on monitor display. Methods: Reading speed test were carried out for 53 subjects (mean age: $22.68{\pm}1.85$ years) who have over Best-corrected visual acuity (BCVA) 1.0, and 45 subjects, who could read over 123 out of 163 letters among 53 subjects were selected. They were asked to read the letters which were composed of Black (contrast 100%), Dark gray (contrast 80%), Gray (contrast 80%), Light gray (contrast 30%) randomly. The change of their eye fatigue by letter contrast on monitor display was measured by monitoring their eyes with an eye-tracker while they were reading letters. Results: Event Duration (sec) was 33.635 for Black, 32.266 Dark gray, 33.936 for Gray, and 34.848 for Light gray. Average of Fixation Duration (sec) was 0.224 for Black, 0.218 for Dark gray, 0.239 for Gray and 0.243 for Light gray. Average of Pupil diameter (mm) was 41.133 mm for Black, 41.160 mm for Dark gray, 40.880 mm for Gray and 40.459 mm for Light gray. Frequency (blinks/sec) was 0.211 for Black, 0.206 for Dark gray, 0.221 for Gray, and 0.238 for Light gray. Conclusions: Event Duration and average of Fixation Duration were the shortest for Dark gray and the longest for Light gray. In average Pupil diameter was the biggest Dark gray and the smallest for Light gray. Blink Frequency (blinks/sec) was the lowest for Dark gray and the highest for Light gray. Visual fatigue by brightness of letters on monitor display was the least for Dark gray followed by Black, Gray and Light gray.

Texture analysis of Thyroid Nodules in Ultrasound Image for Computer Aided Diagnostic system (컴퓨터 보조진단을 위한 초음파 영상에서 갑상선 결절의 텍스쳐 분석)

  • Park, Byung eun;Jang, Won Seuk;Yoo, Sun Kook
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.1
    • /
    • pp.43-50
    • /
    • 2017
  • According to living environment, the number of deaths due to thyroid diseases increased. In this paper, we proposed an algorithm for recognizing a thyroid detection using texture analysis based on shape, gray level co-occurrence matrix and gray level run length matrix. First of all, we segmented the region of interest (ROI) using active contour model algorithm. Then, we applied a total of 18 features (5 first order descriptors, 10 Gray level co-occurrence matrix features(GLCM), 2 Gray level run length matrix features and shape feature) to each thyroid region of interest. The extracted features are used as statistical analysis. Our results show that first order statistics (Skewness, Entropy, Energy, Smoothness), GLCM (Correlation, Contrast, Energy, Entropy, Difference variance, Difference Entropy, Homogeneity, Maximum Probability, Sum average, Sum entropy), GLRLM features and shape feature helped to distinguish thyroid benign and malignant. This algorithm will be helpful to diagnose of thyroid nodule on ultrasound images.

A Performance Improvement of GLCM Based on Nonuniform Quantization Method (비균일 양자화 기법에 기반을 둔 GLCM의 성능개선)

  • Cho, Yong-Hyun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.2
    • /
    • pp.133-138
    • /
    • 2015
  • This paper presents a performance improvement of gray level co-occurrence matrix(GLCM) based on the nonuniform quantization, which is generally used to analyze the texture of images. The nonuniform quantization is given by Lloyd algorithm of recursive technique by minimizing the mean square error. The nonlinear intensity levels by performing nonuniformly the quantization of image have been used to decrease the dimension of GLCM, that is applied to reduce the computation loads as a results of generating the GLCM and calculating the texture parameters by using GLCM. The proposed method has been applied to 30 images of $120{\times}120$ pixels with 256-gray level for analyzing the texture by calculating the 6 parameters, such as angular second moment, contrast, variance, entropy, correlation, inverse difference moment. The experimental results show that the proposed method has a superior computation time and memory to the conventional 256-level GLCM method without performing the quantization. Especially, 16-gray level by using the nonuniform quantization has the superior performance for analyzing textures to another levels of 48, 32, 12, and 8 levels.

Comparisons of Object Recognition Performance with 3D Photon Counting & Gray Scale Images

  • Lee, Chung-Ghiu;Moon, In-Kyu
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.388-394
    • /
    • 2010
  • In this paper the object recognition performance of a photon counting integral imaging system is quantitatively compared with that of a conventional gray scale imaging system. For 3D imaging of objects with a small number of photons, the elemental image set of a 3D scene is obtained using the integral imaging set up. We assume that the elemental image detection follows a Poisson distribution. Computational geometrical ray back propagation algorithm and parametric maximum likelihood estimator are applied to the photon counting elemental image set in order to reconstruct the original 3D scene. To evaluate the photon counting object recognition performance, the normalized correlation peaks between the reconstructed 3D scenes are calculated for the varied and fixed total number of photons in the reconstructed sectional image changing the total number of image channels in the integral imaging system. It is quantitatively illustrated that the recognition performance of the photon counting integral imaging system can be similar to that of a conventional gray scale imaging system as the number of image viewing channels in the photon counting integral imaging (PCII) system is increased up to the threshold point. Also, we present experiments to find the threshold point on the total number of image channels in the PCII system which can guarantee a comparable recognition performance with a gray scale imaging system. To the best of our knowledge, this is the first report on comparisons of object recognition performance with 3D photon counting & gray scale images.