• Title/Summary/Keyword: gradient reduction

Search Result 309, Processing Time 0.022 seconds

Load Frequency Control of Power System using Self Organizing Fuzzy Controller (자기조직화적 퍼지제어기를 이용한 전력계통의 부하주파수제어)

  • Lee, J.T.;Chung, D.I.;An, B.C.;Joo, S.M.;Chung, H.H.
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.23-25
    • /
    • 1993
  • This paper presents a design technique of self-organizing fuzzy controller using a learning method of fuzzy inference rule by a gradient method for load frequency control of power system. The membership functions in antecedent part and in consequent part of fuzzy inference rules are tuned by the gradient method. The related simulation results show that the proposed fuzzy controller are more powerful than the conventional ones for reduction of undershoot and deviation of load frequency in steady-state, and for minimization of settling time.

  • PDF

Boundary Layer Separation Control with Fairing at the Junction of 3D Wings Under Ground Effect (페어링을 이용한 지면효과를 받는 3차원 날개 접합부의 경계층 박리 제어)

  • Cho Ji. H.;Moon Young. J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.57-64
    • /
    • 2005
  • Aerodynamic characteristics of three-dimensional wings in ground effect for Aero-levitation Electric Vehicle(AEV) are numerically investigated for various fairing shapes at the junctions of 3D Wings. Numerical results show that a sizeable three-dimensional comer flow separation occurs with formation of an arch vortex at the junction of main and vertical wings, and also that this is predicted the main cause of the high lift-to-drag(L/D) reduction rate of the main wing. To avoid the comer flow separation, the main idea of this study is to reduce the cross section gradient of the comer flow tube near the trailing edge for various fairing shapes. Improvements on L/D ratios of the wings are pursued by breaking the coherence of superimposed adverse pressure gradients at the wing junction when the cross section gradient is changed slowly at the trailing edge.

  • PDF

A Simple Algorithm for Measuring the Position and Time Interval of the ECG Wave Components (ECG 파형 성분의 위치와 time interval 측정알고리즘)

  • 이명호;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.53-62
    • /
    • 1985
  • The position and time interval of wave components of the electrocardiogram are used as important data for physician's diagnosis. In case of using the existing definition of the onset of the wave component of the electrocardiogram, they have some problems of defining the precise position of the isoelectric line, of defining the limit of the gradient accepted as the onset, and of the gradient being changed by noise. Therefore, in this paper all time intervals and positions of wave components needed for data of diagnosis were obtained correctly by turning point data reduction algorithm and linear regression intersection algorithm, and the viability of the method of intersecting lines was established in comparison to the four methods of calculating the PR interval.

  • PDF

Electric double layers interactions under condition of variable dielectric permittivity

  • Payam, Amir Farrokh;Fathipour, Morteza
    • Interaction and multiscale mechanics
    • /
    • v.3 no.2
    • /
    • pp.157-171
    • /
    • 2010
  • In this paper, a theoretical method has been developed for the electric double layer interaction under condition of the variable dielectric permittivity of water. Using Poisson-Boltzmann equation (PBE), for one plate and two plates having similar or dissimilar constant charge or constant potential, we have investigated the electric double layer potential, its gradient and the disjoining pressure as well as the effect of variation of dielectric permittivity on these parameters. It has been assumed that plates are separated by a specific distance and contain a liquid solution in between. It is shown that reduction of the dielectric permittivity near the interfaces results in compression of electric double layers and affects the potential and its gradient which leads to a decreased electrostatic repulsion. In addition, it is shown that variation of dielectric permittivity in the case of higher electrolyte concentration, leads to a greater change in potential distribution between two plates.

The application of DGTs for assessing the effectiveness of in situ management of Hg and heavy metal contaminated sediment

  • Bailon, Mark Xavier;Park, Minoh;Choi, Young-Gyun;Reible, Danny;Hong, Yongseok
    • Membrane and Water Treatment
    • /
    • v.11 no.1
    • /
    • pp.11-23
    • /
    • 2020
  • The effectiveness of in situ sediment capping as a technique for heavy metal risk mitigation in Hyeongsan River estuary, South Korea was studied. Sites in the estuary were found previously to show moderate to high levels of contamination of mercury, methylmercury and other heavy metals. A 400 m × 50 m section of the river was selected for a thin layer capping demonstration, where the total area was divided into 4 sections capped with different combinations of capping materials (zeolite, AC/zeolite, AC/sand, zeolite/sand). Pore water concentrations in the different sites were studied using diffusive gradient in thin film (DGT) probes. All capping amendments showed reduction in the pore water concentration of the different heavy metals with top 5 cm showing %reduction greater than 90% for some heavy metals. The relative maxima for the different metals were found to be translated to lower depths with addition of the caps. For two-layered cap with AC, order of placement should be considered since AC can easily be displaced due to its relatively low density. Investigation of methylmercury (MeHg) in the site showed that MeHg and %MeHg in pore water corresponds well with maxima for sulfide, Fe and Mn suggesting mercury methylation as probably coupled with sulfate, Fe and Mn reduction in sediments. Our results showed that thin-layer capping of active sorbents AC and zeolite, in combination with passive sand caps, are potential remediation strategy for sediments contaminated with heavy metals.

A Study on the Changes in Microstructures and Mechanical Properties of Unidirectionally Solidified Al-Cu Alloys due to Cold-Rolling (Al-Cu 합금의 일방향 응고조직과 기계적 성질에 미치는 냉간압연의 영향)

  • Oh, Myung-Hwan;Ra, Hyong-Yong
    • Journal of Korea Foundry Society
    • /
    • v.3 no.1
    • /
    • pp.3-12
    • /
    • 1983
  • The influence of columnar dendirtes on the mechanical properties of Al-1% Cu alloys as unifirectionalloy solidified under the conditions of controlled crystal growth rate (R) and temperature gradient (G) was investigated. And the change of metallography and mechanical properties when unifirectionalloy solidified alloys and cast alloys were cold-rolled from 10% to 90% in reduction ratio was studied. The results are as follows: 1. The elongation and yield strength of unifirectionalloy solidified alloy are higher then those of cast alloy, but there is a little decrease in ultimate tensile strength. 2. The metallography and mechanical properties are changeable with the primary arm spacings when the unidirectionalloy solidified alloys were cold-rolled from 10% to 90% in reduction ratio. An alloy with larger primary arm spacings was easily changeable in metallography and mechanical properties when it was cold-rolled. 3. The tensile strength of transversely cold-rolled to 90% in reduction ratio was higher then that of longitudionalloy cold-rolled to 90% in reduction ratio. In the case, the fractorgraphs of fractured surface showed that the cast alloy and the unifirectionalloy solidified alloy was ductile-fractured, but the surface of transversely cold-rolled to 90% reduction of unidirection alloy solidified was slip plane qracture.

  • PDF

Role of $Na^+/Ca^{2+}$ Exchange in the Control of Contractility in Rabbit Basilar Arterial Smooth Muscle

  • Kim, Eui-Yong;Han, Jin
    • The Korean Journal of Physiology
    • /
    • v.28 no.2
    • /
    • pp.159-167
    • /
    • 1994
  • The contraction of rabbit basilar artery was examined as a function of changes in the $Na^+$ electrochemical gradient in order to determine the contribution of $Na^+/Ca^{2+}$ exchange to the modulation of contractility. Ouabain $(10^{-5}\;M)$ or $K^+-free$ Tyrode solution caused an increase in tonic tension even in the presence of a $Ca^{2+}$ channel blocker $(10^{-6}\;M\;verapamil)$ and an ${\alpha}-receptor$ blocker $(10^{-5}\;M\;phentolamine)$. After treatment with ouabain $(10^{-5}\;M)$, contractions were augmented by reduction of external $Na^+$ concentration. The longer the treatment with ouabain $(10^{-5}\;M)$ was, the larger the amplitude of $Na^+-free$ contracture was. $Na^+-free$ contracture wag induced by either substitution of equimolar Tris for $Na^+$ or substitution of equimolar $Li^+\;for\;Na^+$. The competition between $Na^+\;and\;Ca^{2+}$ for the $Na^+/Ca^{2+}$ exchange carrier would exist, because it was observed that contractility was dependent on the $Na^+$ electrochemical gradient or the extracellular $Ca^{2+}$ concentration (2 mM, 4 mM). Ryanodine $(10^{-7}\;M)$, the blocker of intracellular $Ca^{2+}$ release from the sarcoplasmic reticulum, did not suppress the development of $Na^+-free$ contracture. The contractile response to norepinephrine $(10^{-6}\;M)$ was augmented by reducing the extracellular $Na^+$ concentration. The relaxation rate from caffeine-induced contraction was dependent on the extracellular $Na^+$ concentration (0 mM, 140 mM). From the above results, it could be suggested that $Na^+/Ca^{2+}$ exchange can move $Ca^{2+}$ either into or out of rabbit basilar arterial smooth muscle. $Ca^{2+}$ entry or extrusion is dependent upon the $Na^+$ electrochemical gradient. $Na^+/Ca^{2+}$ exchange plays a significant role in the regulation of contractility in rabbit basilar arterial smooth muscle.

  • PDF

A Study on theProperty of Seepage in the Curved Levee by Numerical Analysis (제방만곡부에서의 침투특성에 관한 수치해석적 연구)

  • Park, Choon-Sik;An, Byeong-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.4
    • /
    • pp.5-17
    • /
    • 2021
  • In this paper, three-dimensional analysis of the curved levee was performed according to curvature angle, and radius of curvature to investigate the property of seepage. The hydraulic gradients in the curved parts of levees decreased in the outer levee and increased in the inner levee, compared to the two-dimensional analysis. The smaller the curvature angle and the radius of curvature, the larger the change of the hydraulic gradient, compared to the two-dimensional analysis. The effect of curvature radius on the hydraulic gradient was greater than the curvature angle. As a result of evaluating the piping safety factor for the critical hydraulic gradient, the safety factor was increased by 2~5% in the outer levee and decreased by 4~12% in the inner levee, compared to the two-dimensional analysis. Considering this reduction, if the two-dimensional analysis is performed on the curved part of the levee, and if designed the safety factor for piping is 0.1~0.3 greater than allowable FS=2.0, the safety factor of the curved part is slightly reduced, but there is no difficulty in securing stability.

A Study on GPU Computing of Bi-conjugate Gradient Method for Finite Element Analysis of the Incompressible Navier-Stokes Equations (유한요소 비압축성 유동장 해석을 위한 이중공액구배법의 GPU 기반 연산에 대한 연구)

  • Yoon, Jong Seon;Jeon, Byoung Jin;Jung, Hye Dong;Choi, Hyoung Gwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.9
    • /
    • pp.597-604
    • /
    • 2016
  • A parallel algorithm of bi-conjugate gradient method was developed based on CUDA for parallel computation of the incompressible Navier-Stokes equations. The governing equations were discretized using splitting P2P1 finite element method. Asymmetric stenotic flow problem was solved to validate the proposed algorithm, and then the parallel performance of the GPU was examined by measuring the elapsed times. Further, the GPU performance for sparse matrix-vector multiplication was also investigated with a matrix of fluid-structure interaction problem. A kernel was generated to simultaneously compute the inner product of each row of sparse matrix and a vector. In addition, the kernel was optimized to improve the performance by using both parallel reduction and memory coalescing. In the kernel construction, the effect of warp on the parallel performance of the present CUDA was also examined. The present GPU computation was more than 7 times faster than the single CPU by double precision.

Hydrogenotrophic Sulfate Reduction in a Gas-Lift Bioreactor Operated at $9^{\circ}C$

  • Nevatalo, Laura M.;Bijmans, Martijn F. M.;Lens, Piet N. L.;Kaksonen, Anna H.;Puhakka, Jaakko A.
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.3
    • /
    • pp.615-621
    • /
    • 2010
  • The viability of low-temperature sulfate reduction with hydrogen as electron donor was studied with a bench-scale gas-lift bioreactor (GLB) operated at $9^{\circ}C$. Prior to the GLB experiment, the temperature range of sulfate reduction of the inoculum was assayed. The results of the temperature gradient assay indicated that the inoculum was a psychrotolerant mesophilic enrichment culture that had an optimal temperature for sulfate reduction of $31^{\circ}C$, and minimum and maximum temperatures of $7^{\circ}C$ and $41^{\circ}C$, respectively. In the GLB experiment at $9^{\circ}C$, a sulfate reduction rate of 500-600 mg $l^{-1}d^{-1}$, corresponding to a specific activity of 173 mg ${SO_4}^{2-}g\;VSS^{-1}d^{-1}$, was obtained. The electron flow from the consumed $H_2$-gas to sulfate reduction varied between 27% and 52%, whereas the electron flow to acetate production decreased steadily from 15% to 5%. No methane was produced. Acetate was produced from $CO_2$ and $H_2$ by homoacetogenic bacteria. Acetate supported the growth of some heterotrophic sulfate-reducing bacteria. The sulfate reduction rate in the GLB was limited by the slow biomass growth rate at $9^{\circ}C$ and low biomass retention in the reactor. Nevertheless, this study demonstrated the potential sulfate reduction rate of psychrotolerant sulfate-reducing mesophiles at suboptimal temperature.