• 제목/요약/키워드: gradient coil

검색결과 78건 처리시간 0.024초

Localized MRI/MRS를 위한 차폐된 두뇌촬영용 $R^{2}$-경사자계코일 (Actively-Shielded Brain-Only $R^{2}$-Gradient Coil for Localized MRI/MRS)

  • 오창현;양윤정;김선경;이윤;이흥규;안창범
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.161-164
    • /
    • 1996
  • An actively-shielded $r^{2}$-gradient coil has been developed for brain localized MRI or MRS. Spatial localization is very useful for spatial volume selection in MRI or MR Spectroscopy(MRS). The radial(or $R^{2}-$) gradient coil is useful in reducing the artifact or in improving the SNR by selecting the volume with less number of RF pulses. It is, however, difficult to implement the coil with a gradient intensity strong enough to use it for practical whole-body MRI system. For example, the smallest volume size for selection is just 6 cm in diameter with a 250 Ampere of current driving for a whole-body system (in case of 70-cm-diameter). In this study, an asymetric $r^{2}$-coil with a small diameter of 35 cm has been designed and implemented for brain localized MRI or MRS. An 8-rod high-pass-type birdcage RF coil has also been implemented. The coil set has been developed for 1.0 Tesla Medison MRI system and its performance has been verified experimentally.

  • PDF

Magnetic Particle Separation by an Optimized Coil: A Graphical User Interface

  • Rouhi, Kasra;Hajiaghajani, Amirhossein;Abdolali, Ali
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.214-219
    • /
    • 2017
  • Magnetic separators that clean the fluid stream from impurities, protect the installations in numerous industries. This paper introduces a graphical user interface (GUI) which proposes an optimized coil separating magnetic particles with a radius from 1 up to 500 µm. High gradient magnetic fields are employed in an arbitrary user defined fluidic channel which is made of a nonmetallic material. The effects of coil parameters are studied and adjusted to design an optimum coil with a minimum Ohmic loss. In addition, to design the coil scheme based on the particle movements, a mathematical particle-tracing model within the fluid channels has been utilized. In comparison to conventional magnetic separators, this model is reconfigurable by the user, produces a weaker magnetic field, allows for continuous purifying and is easy to install, with high separation efficiency. The presented GUI is simple to use, where the coil's manufacturing limitations can be specified.

광섬유자이로의 고리 온도변화에 의한 바이어스 특성 및 온도 보상 (The Bias Drift Due to Fiber Coil Temperature Variation and the Temperature Compensation in Fiber Optic Gyroscope)

  • 조민식;정경호;도재철;최우석;송기원;강수봉;신원철
    • 한국군사과학기술학회지
    • /
    • 제12권2호
    • /
    • pp.222-227
    • /
    • 2009
  • The bias characteristics due to the changes of temperature and temperature gradient of fiber coil are investigated in fiber-optic gyroscope. The bias performance is degraded with the changes of temperature and temperature gradient of fiber coil. The temperature compensation using both the temperature-dependent bias measurement and the temperature-induced error model of fiber-optic gyroscope improves the bias stability about 3 times as much as the uncompensated original case, which leads to very stable bias performance over the temperature range from $-35^{\circ}C$ to $+77^{\circ}C$.

자기공명영상촬영용 경사자계코일의 3차원설계 (3-Dimensional Design of Gradient Coils for Magnetic Resonance Imaging)

  • 류연철;현정호;이흥규;오창현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.235-237
    • /
    • 2006
  • In this paper, the previous 2-D gradient coil design method using loop current elements is extended to 3-D or multi-layer structures which is useful for various MRI applications including MR microscopic imaging where relatively large space may be available for the implementation of the gradient coils. Either the power consumption or the stored energy (thus, inductance), or the combination of the two can be minimized with a set of chosen target field constraints. Complete 3-D design equations for the optimization as well as inductance or resistance calculation are derived. An effective coil shape correction method for a curved current pattern is also developed. The design method can also be easily extended to the active shielding structure.

  • PDF

고온초전도 선재와 정합회로를 이용한 RF coil 제작에 대한 기초연구 (Study on fabricated RF coil using high-temperature superconductor tape and matching circuit for low field MRI system)

  • 김동혁;고락길;강부민;하동우;손명환;문치웅
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권1호
    • /
    • pp.44-47
    • /
    • 2012
  • The substantial improvement of the signal-to-noise ratio (SNR) can be achieved with small-size samples or low-field MRI system by high-temperature superconducting(HTS) RF coil. The typical HTS RF coil made of HTS thin film is expensive and is limited the coil geometry to planar surface coil. In this study, commercial Bi-2223 HTS tapes was used as RF coil for a 0.35T permanent MRI system. It has advantages of both much lower cost and easier fabrication over HTS thin film coil. SNR gain of the image obtained from the HTS RF coil over a conventional Cu RF coil at room temperature was about 2.4-fold and 1.9-fold using the spin echo pulse sequence and gradient echo pulse sequence respectively.

Radiofrequency Coil Design for in vivo Sodium Magnetic Resonance Imaging of Mouse Kidney at 9.4T

  • Lim, Song-I;Woo, Chul-Woong;Kim, Sang-Tae;Choe, Bo-Young;Woo, Dong-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권1호
    • /
    • pp.65-70
    • /
    • 2018
  • The objective of this study was to describe a radiofrequency (RF) coil design for in vivo sodium magnetic resonance imaging (MRI) for use in small animals. Accumulating evidence has indicated the importance and potential of sodium imaging with improved magnet strength (> 7T), faster gradient, better hardware, multi-nucleus imaging methods, and optimal coil design for patient and animal studies. Thus, we developed a saddle-shaped sodium volume coil with a diameter/length of 30/30 mm. To evaluate the efficiency of this coil, bench-level measurement was performed. Unloaded Q value, loaded Q value, and ratio of these two values were estimated to be 352.8, 211.18, and 1.67, respectively. Thereafter, in vivo acquisition of sodium images was performed using normal mice (12 weeks old; n = 5) with a two-dimensional gradient echo sequence and minimized echo time to increase spatial resolution of images. Sodium signal-to-noise ratio in mouse kidneys (renal cortex, medulla, and pelvis) was measured. We successfully acquired sodium MR images of the mouse kidney with high spatial resolution (approximately 0.625 mm) through a combination of sodium-proton coils.

개방형 자기공명영상시스템을 위한 평면형 경사자계코일 (Planar Gradient Coils for an Open MRI System)

  • 이수열;박부식;이정한;이완
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.165-168
    • /
    • 1996
  • Though the planar gradient coils, designed by the magnetic energy minimization procedure, have smaller inductance than conventional gradient coils, the planar gradient oils often suffer from their poor magnetic field linearity. Scaling the spatial frequencies of the current density function designed by the magnetic energy minimization procedure, magnetic field linearity of the planar gradient coils can be featly improved with small sacrifice of gradient coil inductance.

  • PDF

Target Field Approach를 사용한 방사형 표면 경사자계코일의 설계 (Radial Surface Gradient Coil Design Using Target Field Approach)

  • 이종권;양윤정;오창현
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.250-252
    • /
    • 1995
  • 이 논문의 목적은 Target field approach를 사용하여 2차원적인 공간선택을 할 수 있는 방사형 표면 경사 자계코일 (Radial SGC : Radial Surface Gradient Coil)을 설계하는 것이다. 지금까지 쓰이던 원통형의 고차경사자계코일을 이용한 2차원적 원형 선택방법은 한개의 RF Puise로 2차원적인 공간 선택을 할 수 있는 장점이 있었으나 선택되어지는 체적의 지름이 6-8cm로 너무 크다는 단점이 있었다. 이 논문에서는 이와같은 단점을 극복하기 위해 영상을 얻고자하는 부분에 코일을 좀 더 가까이 붙일 수 있으며 선택되어지는 체적의 지름을 1-4cm까지 줄일 수 있는 표면 고차자계코일을 Target field approach 방법을 이용하여 설계하였으며 Phantom과 인체영상을 통해 제작된 코일의 성능을 확인해 보았다. 과거에 사용되었던 Field component method에서는 선택되는 부분이 찌그러지는 경우가 있었으나 Target field approach 방법에 의해 설계된 코일에 의하여 선택되는 부분은 이상적인 원에 가까운 모양이 되었다.

  • PDF

부분적인 경사자계를 이용한 고속 자기공명 영상촬영기법 (Fast MR Imaging Technique by Using Locally-Linear Gradient Field)

  • 양윤정;이종권
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.93-98
    • /
    • 1996
  • The purpose of this paper is to propose a new localized imaging method of reduced imaging time luting a locally-linear gradient. Since most fast MR(Magnetic Resonance) imaging methods need the whole $\kappa$-space(Spatial frequency space) data corresponding to the whole imaging area, there are limitstions in reducing the minimum imaging time. The imaging method proposed in this paper uses a specially-made gradient coil generating a local ramp-shape field and uniform field outside of the imaging areal Conventional imaging sequences can be used without any RF/gradient pulse sequence modifiestions except the change in the number of encoding steps and the field of view.

  • PDF

자기공명분석과 영상촬영을 위한 차폐된 고차경사자계코일의 설계 (Shielded High-Order Gradient Coil Design for Magnetic Resonance Spectroscopy and Imaging)

  • 오창현;;이윤;김민기
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 춘계학술대회
    • /
    • pp.45-48
    • /
    • 1993
  • High-order field gradients are useful for spatial localization of a volume of interest and dynamic range improvement of signal detection in NMR (Nuclear Magnetic Resonance) spectroscopy and imaging. This paper proposes a design method of shielded high-order gradient coils to reduce tile effect of eddy current on tile spectroscopy and imaging results. According to the experimental results, the shielded gradient coils produce less than 2 % eddy current compared to non-shielded coils. Two shielded $z^2$ gradient coils have been designed and constructed for 1.5 T whole-body and 3.0 T animal NMR imaging systems. Experimental results are in good agreement with the theoretically expected behavior and show the utility of the shielded high-order gradient coils.

  • PDF