• Title/Summary/Keyword: gold needle

Search Result 17, Processing Time 0.02 seconds

The Study on Temperature Measurement of Warm Needling Using Stainless Steel Needle and Gold Needle (금침과 스테인레스침을 이용한 온침에서의 부위별 온도측정 연구)

  • Yeo, Sujung
    • Korean Journal of Acupuncture
    • /
    • v.30 no.3
    • /
    • pp.178-184
    • /
    • 2013
  • Objectives : The warm needling technique is the method combining the effects of acupuncture needle with those of moxibustion. We need to standardize the characteristics of the warm needling technique, in order to get more systematic and objective results in operation and effects and then get more clinical abilities in these fields. Methods : In this study, using labview system on the warm needling technique, we measured and compared partial temperature changes according to the kind of needle. We studied relations of moxa cones of various sizes with the peak combustion temperature. Results and Conclusions: When we measured the warm needling's partial temperature, temperature measured at 1 and 2 cm below the head, according to the kind of needle, gold needle got the higher result on the peak than SS304 stainless steel needle. In the case of combustion of the moxa cones, cones weighing 0.4 g and 0.8 g, respectively, and the apex ignition method with gold needle showed the higher result than the apex ignition method with stainless steel needle, when we measured the effective stimulus time at 2 cm below the head and the mean temperature during the effective stimulus time. Although more research to standardize the characteristics of the warm needling technique will be needed, we suggest, according to these results, that warm needling of gold needle combined with moxa cone of 0.4 or 0.8 g is effective.

A Review of Research Trends in Gold Implantation Therapy Focused on Gold Thread, Gold Needle and Gold Bead (금사, 금침, 금주를 중심으로 한 금(金)의 인체 내 매장요법에 대한 연구동향 고찰연구)

  • Jo, Dae Hyun;Baatarkhuyag, Ariunchimeg;Jo, Ye Eun;Lee, Sang Hoon;Lee, Jae Dong
    • Journal of Acupuncture Research
    • /
    • v.33 no.1
    • /
    • pp.79-93
    • /
    • 2016
  • Objectives : The purpose of this study is to explore research trends in gold implantation therapy performed on the animal and human body, through a review of clinical studies focused on gold thread, gold needle and gold bead. Methods : Medical databases, including Pubmed, CENTRAL, MEDLINE, EMBASE, RISS4u, KISTI, OASIS and KTKP, were searched for relevant articles published from their launch to December 31, 2015 using the key word 'gold' with '$thread^*$', '$needle^*$', '$acupuncture^*$', '$wire^*$', '$bead^*$', '$embed^*$', '$implant^*$', or '$insert^*$'. The results were classified into in vivo studies, clinical trials and clinical reports. Analysis of the results was conducted in several research areas, from the identity of studies such as nationality and published year, to the gold preparations-features and implanted locations and to the outcomes that reflect the clinically favorable or adverse effect of gold implantation therapy. Results : A total of 30 studies including 11 in vivo studies, 4 clinical trials and 15 case reports, were found in the search. We observed certain research trends according to the research time, nationality and target indication of the studies. The studies primarily revealed a chronic local inflammatory response which could be a useful mechanism for pain-relief in musculoskeletal diseases and facial rejuvenation. Researches concerning long-term reactions or adverse effects were rare. Conclusion : The results show that the efforts to discover the level of clinical efficacy of gold implantation therapy were steady and worldwide. However, further researches on the longterm effect, and more importantly, the safety of gold implantation therapy are required.

The Characteristics of Temperature Variation in Electronic Warm Acupuncture Device (전기식 온침기의 온도 변화 특성에 관한 연구)

  • Ja-Ha Lee;Jeong-Hyun Moon;U-Ryeong Chung;Soo-Hwa Hong;Gyoungeun Park;Byung Wook Lee;Won-Suk Sung;Jong-Hwa Yoon;Eun-Jung Kim
    • Korean Journal of Acupuncture
    • /
    • v.40 no.4
    • /
    • pp.184-193
    • /
    • 2023
  • Objectives : The purpose of this study is to understand the temperature characteristics depending on the thickness and material of the needle used with the Electronic Warm Acupuncture Device (EWAD). Methods : We controlled experimental environment and measured temperature changes of a silicon phantom in which K-type thermocouples were inserted at depths of 2, 7 mm. EWAD perfomed with acupuncture needles of various thicknesses (0.25×60 mm, 0.40×60 mm, and 0.50×60 mm) and materials (Gold 0.40×50 mm). We set non-needle (only heated with EWAD skin heater) group as a control group. Results : The maximum temperature and temperature changes of 0.40 mm, 0.50 mm needle group were significantly higher than the non-needle group. The highest temperature range in all needle groups was 0.50 mm needle group (41.44±0.31℃). However, the 0.25 mm needle group was not significantly different from the non-needle group. Maximum temperature of gold needle group was significantly higher than stainless steel needle group. Temperature changes of gold needle group were higher than stainless steel group at the depth of 7 mm. Conclusions : It was found that needle thickness and material of acupuncture had an effect on the temperature of the EWAD. When performing EWAD treatment, consideration of thickness and material of acupuncture is needed. Future research is needed using phantoms that can reflect actual clinical situations and better mimic the human body.

A Review on the Characteristics of Temperature Variation in Warm Needle (온침의 온도변화 특성에 대한 문헌 고찰 연구)

  • Lee, Ju Hyun;Jo, Hyo Rim;Kim, Seon Hye;Lee, Yeon Sun;Park, Se Won;Moon, So Ri;Jung, Chan Yung;Sung, Won Suk;Cho, Hyun Seok;Kim, Kyung Ho;Lee, Byung Wook;Kim, Eun-Jung
    • The Journal of Korean Medicine
    • /
    • v.40 no.3
    • /
    • pp.112-138
    • /
    • 2019
  • Objectives: The purpose of this study is to organize the research methods and results of studies related to the temperature of the warm needle for systematic utilization of warm needling technique. Methods: This study used the databases of nine (Pubmed, Science Direct, Cochrane Central, 4 Korean databases, CNKI, CiNii) to analyze temperature-related studies of the warm needle from 2000 to June 2019. Results: A total of 19 papers were included. Of these, 15 were used for mugwort, 2 for high frequency, and 1 for both mugwort and high frequency, and the other one for a ceramic heater. The maximum temperature rises as the amount of moxibustion increases. It is also affected by the density of moxa and the ignition part. There were 16 papers using stainless steel needles and 4 papers using a needle made of gold or silver to compare. In the area of the needle, the closer it is to moxibustion, the hotter it is. Compared to stainless steel needles, gold and silver needles showed almost twice the temperature. The effects of environment and radiant heat should be considered during warm needle procedures. Conclusions: There are various experimental methods such as warm needle technique materials, methods, measuring parts, measuring instruments, etc. The results were also very diverse. When setting the heating source, ignition part, size of moxibustion, etc. of warm needles, it should be implemented in a way that takes safety and validity into account. Considerations for temperature characteristics, radiant heat, etc. of warm needles will be needed when making warm needle apparatus.

A STUDY ON SURFACE OF VARIOUS ABUTMENT SCREWS

  • Park Chan-Ik;Chung Chae-Heon;Choi Han-Cheol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.351-359
    • /
    • 2003
  • Statement of problem: Regardless of any restoration, most of case, we used in screw connection between abutment and implant. For this reason, implant screw loosening has been remained problem in restorative practices. Purpose: The purpose of this study was to compare surface of coated/plated screw with titanium and gold alloy screw and to evaluate physical property of coated/plated material after scratch test in FESEM investigation Material and methods: GoldTite, titanium screw provided by 3i (Implant Innovation, USA) and TorqTite, titanium screw by Steri-Oss (Nobel Biocare, USA) and gold screw, titanium screw by AVANA (Osstem Implant, korea) - were selected for this study. Each abutment screw surface was observed at 100 times, and then screw crest, root, and slope were done more detailed numerical value, at 1000 times with FESEM. A micro-diamond needle was also prepared for the scratch test. Each abutment screw was fixed, micro-diamond scratch the surface of head region was made at constant load and then was observed central region and periphery of fine trace through 1000 times with FESEM. Results: The surface of GoldTite was smoother than that of other kinds of screw and had abundant ductility and malleability compared with titanium and gold screw. The scratch test also showed that teflon particles were exfoliated easily in screw coated with teflon. Titanium screw had a rough surface and low ductility. Conclusion: It was recommended that the clinical use of gold-plated screw would prevent a screw from loosening. CLINICAL IMPLICATIONS Clinical use of gold-plated screw would prevent a screw from loosening because it had abundant ductility and malleability compared with titanium and gold screw.

Effect of Nozzle Material on Drop Size Distribution in Electrohydrodynamic Spraying (전기수력학적 분무에서 노즐재질이 입경분포에 미치는 영향)

  • 김명찬;이상용
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.10
    • /
    • pp.1451-1457
    • /
    • 2002
  • When an aqueous liquid such as water having high electric conductivity and high surface tension is discharged from a nozzle under a strong DC electric field, fine drops ranging from 30 to 450 microns can be obtained only through the spindle mode. In the present study, effects of the electric conductivity and the surface wettability of nozzle materials on formation of drops with this mode were investigated. For that, three nozzles with the same size but with different materials were prepared and tested; a stainless steel needle, and a plain and a metal (gold)-coated (except for the tip portion) silica needles. Uniform drops were obtained with the gold-coated silica nozzle over the wider range of the DC voltage input. That is, formation of the liquid cone and detachment of the liquid spindle (ligament) can be more stabilized and frequent with the needles having high electric conductivity but with low surface wettability at their tips.

Interstitial Radium Implantation and Cobalt-60 Irradiation of the Tongue Cancer (IbidI) (설암의 조직간내 라디움치료에 관하여)

  • 안경성;박주방;윤용규
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.16.1-16
    • /
    • 1972
  • In 1971 there were 5 cases of the tongue cancer in stage I & II treated concomitantly with interstitial radium implantation and Cobalt-60 irradiation at the Yonsei University Hospital Cancer Center. This is the interim report of the course of the primary site of those treated cases.

  • PDF

Endoscopic Management of Gastric Subepithelial Tumor (위상피하종양의 내시경적 진단 및 치료)

  • Hyunchul Lim
    • Journal of Digestive Cancer Research
    • /
    • v.10 no.1
    • /
    • pp.16-21
    • /
    • 2022
  • Diagnosis of gastric subepithelial tumors (SETs) is sometimes difficult with conventional endoscopy or tissue sampling with standard biopsy, so non-invasive imaging modalities such as endoscopic ultrasound (EUS) and computed tomography are used to evaluate the characteristics of SETs features (size, location, originating layer, echogenicity, shape). However imaging modalities alone is not able to distinguish among all types of SETs, so histology is the gold standard for obtaining the final diagnosis. For tissue sampling, mucosal cutting biopsy and mucosal incision-assisted biopsy and EUS-guided fine-needle aspiration or biopsy (EUS-FNA or EUS-FNB) is commonly recommended. Endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD) are used for resection of SETs involving the mucosal and superficial submucosal layers, could not treat adequately and safely the SETs involving the deep mucosa and muscularis propria. Submucosal tunneling endoscopic resection (STER) and endoscopic full-thickness resection (EFTR) is used as a therapeutic option for the treatment of SETs with the development of reliable endoscopic closure techniques and tools.

Pulmonary Sarcoidosis Diagnosed by Endobronchial Ultrasound Fine Needle Aspiration (초음파 기관지 내시경 세침흡인을 이용하여 진단한 폐 사르코이드증)

  • Kim, Won-Young;Chang, You-Jin;Lyu, Ji-Won;Park, Young-Soo;Jang, Se-Jin;Song, Jin-Woo;Oh, Yeon-Mok;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Choi, Chang-Min
    • Tuberculosis and Respiratory Diseases
    • /
    • v.68 no.5
    • /
    • pp.267-272
    • /
    • 2010
  • Background: Pulmonary sarcoidosis often involves mediastinal or hilar lymph nodes in the lung parenchyma. Mediastinoscopy is the gold standard for diagnosis, but it is invasive and expensive. Transbronchial needle aspiration using conventional bronchoscope is less invasive than mediastinoscopy, but its diagnostic accuracy is in question due to the blind approach to targeting lymph nodes. Transbronchial needle aspiration (TBNA) via endobronchial ultrasound (EBUS) has high diagnostic value due to direct visualization of lymph nodes and to its relatively safeness. The purpose of this study was to assess the usefulness of EBUS-TBNA in the diagnosis of pulmonary sarcoidosis. Methods: Twenty-five patients with symptoms of sarcoidosis were enrolled into this study. Core tissue was obtained for a definitive diagnosis. Endobronchial biopsy, transbronchial lung biopsy, and bronchoalveolar lavage were performed to verify diagnosis. For patients without a confirmed diagnosis after the above procedures were performed, the additional procedures of mediastinoscopy or video-associated thoracoscopic surgery were performed to confirm a final diagnosis. Results: A total 25 EBUS procedures were done and 50 lymph nodes were aspirated. Thirty-three (37) out of 50 lymph nodes were consistent with non-caseating granuloma, confirming sarcoidosis as the final diagnosis. Sarcoidosis was the final diagnosis for all 25 patients, and 21 required EBUS-TBNA for a final diagnosis. There were no complications associated with the procedure. Conclusion: EBUS-TBNA is already a well-known procedure for diagnosing mediastinal or hilar lymphadenopathy. We used EBUS-TBNA for the diagnosis of pulmonary sarcoidosis and our results showed 84% diagnostic accuracy and no complications related to the procedure. EBUS-TBNA is a reliable and practical diagnostic modality in the diagnosis of pulmonary sarcoidosis.

Diagnostic Accuracy, Sensitivity, Specificity and Positive Predictive Value of Fine Needle Aspiration Cytology (FNAC) in Intra Oral Tumors

  • Gillani, Munazza;Akhtar, Farhan;Ali, Zafar;Naz, Irum;Atique, Muhammad;Khadim, Muhammad Tahir
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3611-3615
    • /
    • 2012
  • Objective: The objective of this study was to establish the diagnostic accuracy, specificity and sensitivity of fine needle aspiration cytology(FNAC) for intra-oral tumors, comparing with histopathology as the gold standard. Materials and methods: Forty cases of FNA cytology from intraoral tumors was performed in AFID along with the demographic data and clinical information and then diagnosed at AFIP, Rawalpindi. Then the cytology results obtained per FNAC were compared with the histopathological biopsy results of the same lesions. The following variables were recorded for each patient: Age, gender, site of biopsy, diagnosis. The data were entered and analyzed using Open-epi version 2.0. Diagnostic accuracy, sensitivity, specificity, positive predictive value and negative predictive value were calculated. Cohen Kappa was further applied to compare the agreement between the biopsy and FNAC diagnoses. A p-value of < 0.05 was considered as statistically significant. Results: Among the total patients included in the study there were 24 males and 16 females, with a ratio of 1.5:1. Age of the patients ranged from 24 to 80 years with a mean of 52 years. A total of six sites were aspirated from the oral cavity with maximum (11) aspirates taken from alveolar ridge. The results of FNAC revealed that there were 32 malignant and 8 benign aspirates. Confirmation through histopathological analysis came for 31/32 malignant cases while one was falsely given positive for malignancy on FNAC. Among a total of 40 cases, 31(77%) cases diagnosed were found to be malignant and remaining 9(23%) were benign. The FNAC results revealed 32 malignant and 8 benign lesions. Histopathology of the subsequent surgically excised specimen showed malignant lesions in 31(77%) and benign in 9(23%) patients. As a whole, it was found that the absolute sensitivity for introral FNAC was 100% and specificity 89% with positive predictive value of 97% and negative predictive value of 100%. Conclusion: Cytological diagnosis was almost corroborative with final histopathological diagnosis in all cases, with very few exceptions, exhibiting high diagnostic accuracy.